ActivePure Transit Guardian External User manual

TRANSIT GUARDIAN
EXTERNAL
™
READ MANUAL CAREFULLY FOR
PROPER USE AND OPERATION.
COMMERCIAL VEHICLE
AIR PURIFICATION SYSTEM

2
GENERAL INFORMATION
If you have any questions concerning this, or any ActivePure product,
contact ActivePure Customer Service at 800.572.1446
or email customerservice@ActivePure.com.
CONTENTS
Product Overview . . . . . . . . . . 2
Specifications. . . . . . . . . . . . 2
Storage and Disposal . . . . . . . . . 2
Important Safety Instructions. . . . . . 3
For Canadian Customers Only . . . . . 4
Inspection . . . . . . . . . . . . . 5
Parts View . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . 7
Maintenance . . . . . . . . . . . . 8
Replacement Parts & Service. . . . . . 9
Warranty Information . . . . . . . . . 10
FCC Declaration & Responsible Party . . 11
PRODUCT OVERVIEW
Congratulations on your purchase of the ActivePure®Transit Guardian – External! Your new
ActivePure Transit Guardian – External utilizes tested ActivePure®Technology to help reduce
the spread of viruses in the air. It is designed to be mounted on a wall, ceiling, or floor. Be sure
to read and follow all service procedures outlined in this owner’s manual, and use only genuine
ActivePure replacement parts.
STORAGE AND DISPOSAL
Do not dispose of this product as household
waste. Electrical waste and electronic
products should be appropriately recycled as
required by practices established by your
local authority.
SPECIFICATIONS
ActivePure Transit Guardian – External
• Model number: B101B
• Sales number: 00775
Technology:
• ActivePure
Electrical:
• Input Voltage: 12~14 VDC
• Negative Grounded System
• Current: 2.04 A
• Complies to UL 507
Mechanical:
• Airflow: 50 CFM
Sound Level:
• 67 dB(A)
Weight & Dimensions:
• 5.3 lbs (2.4 kg)
• 5” H x 13” W x 7.5” D
(12 cm x 33.02 cm x 19.05 cm)
*w/ mounting hardware
Operating Temperature:
• 34º F to 200º F (1ºC – 93ºC)
Recommended Maximum Coverage in a
Contiguous Space:
• Up to 350 sq. . (31m) depending on
occupant density and other factors.
Warranty:
• Limited Three (3) Year Warranty
ActivePure Manufacturing, LLC reserves the right to
change or modify any specification without notice.

3
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
• When using an electrical appliance, basic precautions should
always be taken
• UV Light in operation; before servicing or cleaning unit, switch
power o at service panel and lock the service disconnecting
means to prevent power from being switched on accidentally;
when the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to
the service panel
• To reduce the risk of fire, electrical shock, or injury to persons,
observe the following:
WARNING
Read this manual in its entirety before using your ActivePure®Transit Guardian – External.
Keep out of the reach of children.
• Use only in the manner intended by the manufacturer; if you have any questions, contact
ActivePure
• DO NOT aempt to repair or adjust any of the electrical or mechanical functions of this
unit
• Installation work and electrical wiring must be performed by qualified person(s) in
accordance with all applicable codes and standards, including fire-rated construction
• When drilling into a wall, DO NOT damage any electrical wiring
• DO NOT use this fan with any Solid-State Speed Control
• DO NOT use outdoors or on wet surfaces
• DO NOT allow to be used as a toy; DO NOT allow children around the unit
• DO NOT handle appliance with wet hands
• DO NOT allow foreign objects to enter the ventilation openings
• Keep hair, clothing, fingers, and all parts of body away from openings
• To reduce the risk of electrical shock, DO NOT expose to water or rain
CAUTION
Installation work and electrical wiring must be performed by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.

4
FOR CANADIAN CUSTOMERS ONLY
ACTIVEPURE®TRANSIT GUARDIAN EXTERNAL
Sales No. : 00775
This UV device helps reduce the spread of viruses in the air.
Keep out of the reach of children.
Please read the label and owner's manual before using: www.activepure.com/manuals
PRECAUTIONS:
WARNING: UV radiation emied from this device. Unintended use of the device, or damage to
the housing, may result in exposure to ultraviolet radiation. Ultraviolet radiation may cause eye
and skin irritation. Avoid exposing eyes and skin to ultraviolet radiation.
FIRST AID INSTRUCTIONS: Please contact your healthcare provider in the event of injury
caused by this device.
DIRECTIONS FOR USE:
Installation work and electrical wiring must be performed by qualified person(s) in accordance
with all applicable codes and standards, including fire-rated construction. Please see owner's
manual for detailed instructions on using, handling, storing and disposing of the device, and
procedures to mitigate any associated risks.
The use of this device is a supplement to and not a substitute for standard infection control
practices; users must continue to follow all current infection control practices, including those
related to the cleaning and disinfection of environmental surfaces.
FOR INQUIRIES CONTACT:
AERUS CANADA, INC.
Laird Business Park
3480 Laird Road, Units 2–5
Mississauga, Ontario, Canada, L5L 5Y4
W. Parrell, Manager
(905) 569-9399
Aerus Canada, Inc. is ailiated with ActivePure Manufacturing, LLC
1300 Valley Drive, Bristol, VA 24201

5
INSPECTION
1. Remove unit from shipping carton.
2. Remove all protective materials.
3. Check for missing or broken parts due to shipping damage.
4. Read Owner’s Manual thoroughly prior to installation.
5. Determine placement location for the unit, follow installation
instructions on page 7.

6
PARTS VIEW
Vent Exhaust
Opening
Fan (2)
Ballast
Assembly
ActivePure Cell
4-Pin Connector
Cover

7
The ActivePure®Transit Guardian – External is designed to be mounted onto a wall, ceiling, or
floor, as high as possible. Installer is responsible to select and use the appropriate type of
fastener to mount the unit securely.
1. Connect 12 VDC power cable to the black lead and white lead from the ActivePure
Transit Guardian – External according to local or national codes.
2. Use electrical hook up from internal unit to secure wiring connection to cover plate.
INSTALLATION
Mounting Brackets
Back View of Unit
Power Connection
2-Pin
Plug
Plug to Micro
Blue Wires
Red Wires
ActivePure Cell
Safety
Switch Fan Fan
Ballast
Wire Nut
Red Wires
Wire
Assembly
Wire Nut
Black Wires
Switch to Ballast
CAUTION
Installation work and electrical wiring must be performed by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.

8
The only maintenance the ActivePure®Transit Guardian – External requires is replacement of
the ActivePure Cell. We recommend replacing the ActivePure Cell every 12 months.
1. Disconnect power to the unit.
2. Remove four (4) screws from the cover and slide the cover away from unit. See Fig. 1
3. Unplug 4-pin connector from the ActivePure Cell (red & blue leads). See Fig. 2
4. Remove four (4) nuts from the ActivePure Cell brackets and remove the ActivePure Cell.
See Fig. 2
5. We recommend vacuuming o the vent openings to remove any dust build-up. See Fig. 3
NOTE: A face mask should be worn to prevent inhalation of any particles released into the
air during any cleaning process. Eye protection is also recommended.
• Service should only be performed by a qualified electrician
• Make sure power to the unit is disconnected at the power
source
WARNING
MAINTENANCE
Cover
Screw (4)
Fig. 1 Fig. 2
Fan (2)
Vent Exhaust
Opening

9
Fig. 3
Nuts (4)
4-Pin Connector ActivePure Cell
Fan (2)
REPLACEMENT PARTS QTY PART NUMBER
ActivePure Cell Replacement Kit 50218
To order replacement parts, contact your sales representative or
ActivePure Customer Service for further assistance at 800.572.1446
or email customerservice@ActivePure.com.
REPLACEMENT PARTS SERVICE
MAINTENANCE CONTINUED
6. Slide the new ActivePure®Cell into place. Note orientation of the ActivePure Cell in
relation to the fan. See Fig. 1 & 3
7. Reverse Steps 1 – 4 to reconfigure the unit.
NOTE: Verify the new ActivePure Cell is working by looking for a glow from the vent
exhaust opening.

10
Limited Three (3) Year Warranty
To register your ActivePure®Transit Guardian – External unit, visit www.activepure.com/warranty.
To view full details of warranty coverage, visit www.activepure.com/manuals.
WARRANTY INFORMATION
If you have any questions concerning this, or any ActivePure product,
contact ActivePure Customer Service at 800.572.1446
or email customerservice@ActivePure.com.

11
FCC Declaration of Conformity
Name: ActivePure®Transit Guardian – External
Model: B101B
Manufacturer: ActivePure Manufacturing, LLC
This device complies with Part 15 of the
FCC Rules.
Responsible Party
ActivePure Manufacturing, LLC
1300 Valley Drive
Bristol, VA 24201
Ph: 800.572.1446
Signature:
Printed Name: Andrew Eide
Title: Vice President of Product Development
and Manufacturing
Date: 01/27/22
This equipment has been tested and
found to comply with the limits for
a Class B digital device, pursuant of
part 15 of the FCC Rules. These limits
are designed to provide reasonable
protection against harmful interference
in a residential installation. This
equipment generates, uses, and can
radiate radio frequency energy, and if
not installed and used in accordance
with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does
cause harmful interference to radio or
television, which can be determined by
turning the equipment off and on, the
user is encouraged to try to correct
the interference by one or more of the
following measures:
•
Reorient or relocate the receiving
antenna.
•
Increase the separation between
the equipment and receiver.
•
Connect the equipment into an
outlet on a circuit different from that
to which the receiver is connected.
•
Consult the Independent Contractor
for help.
FCC DECLARATION RESPONSIBLE PARTY

12
For information regarding the use of this product, please call Customer Service.
1.800.572.1446 or email at customerservice@ActivePure.com
www.activepure.com
™
ActivePure Manufacturing, LLC | 1300 Valley Drive | Bristol, VA 24201 | 800.572.1446
Assembled in U.S.A. | © ActivePure Manufacturing, LLC. All Rights Reserved
ATGE_OM_65-00869_VA-01833B_ENG-FR

13
TRANSIT GUARDIAN
EXTERNAL
™
LIRE LE MANUEL ATTENTIVEMENT POUR
CONNAÎTRE LES PROCÉDURES ET LE
FONCTIONNEMENT APPROPRIÉS.
SYSTÈME DE PURIFICATION DE L’AIR
POUR VÉHICULE INDUSTRIEL

14
INFORMATIONS GÉNÉRALES
Si vous avez des questions concernant cet appareil ou un autre produit
ActivePure®, contactez le service à la clientèle ActivePure®au
1 800 572-1446 ou par courriel à l’adresse
customerservice@ActivePure.com.
TABLE DES MATIÈRES
Description du produit . . . . . . . . 14
Spécifications. . . . . . . . . . . . 14
Stockage et mise au rebut . . . . . . . 14
Consignes de sécurité importantes . . . 15
Pour les clients au Canada seulement . . 16
Inspection . . . . . . . . . . . . .17
Pièces. . . . . . . . . . . . . . . 18
Installation . . . . . . . . . . . . . 19
Entretien. . . . . . . . . . . . . .20
Pièces de rechange & service. . . . . . 21
Informations relatives à la garantie . . . .22
Déclaration à la FCC & partie responsable 23
DESCRIPTION DU PRODUIT
Félicitations pour l’achat de votre ActivePure®Transit Guardian — Externe! Votre nouvel
ActivePure®Transit Guardian — Externe emploie la technologie ActivePure®éprouvée pour aider
à réduire la propagation des virus dans l’air. Il est conçu pour être fixé sur un mur, le plafond ou le
sol. Veuillez vous assurer de lire et de suivre toutes les procédures d’entretien décrites dans ce
manuel d’utilisation, et de n’installer que les pièces de rechange d’origine ActivePure.
STOCKAGE ET MISE AU REBUT
Ne pas jeter ce produit comme déchet
ménager. Les déchets électriques et les
produits électroniques doivent être
recyclés convenablement, conformément
aux pratiques établies par votre
administration locale.
SPÉCIFICATIONS
ActivePure Transit Guardian — Externe
• Numéro de modèle : B101B
• Numéro de série: 00775
Technologie:
• ActivePure
Électrique:
• Tension d’alimentation: 12~14 VCC
• Système de mise à la terre négative
• Courant: 2,04 A
• Conforme à la norme UL 507
Mécanique:
• Débit d’air: 50 PCM
Niveau acoustique:
• 67 Db (A)
Poids & dimensions:
• 5,3 lb (2,4 kg)
• 5 po H x 13 po L x 7,5 po P
(12 cm x 33,02 cm x 19,05 cm)
*avec le matériel de fixation
Température de fonctionnement:
• 34 ºF à 200 ºF (1 ºC — 93 ºC)
Couverture maximale pour un
espace étroit:
• Jusqu’à 350 pi (31 m) selon le nombre
d’occupants et d’autres facteurs.
Garantie:
• Garantie limitée de 3 ans
ActivePure®Manufacturing, LLC se réserve le droit de
modifier des spécifications sans préavis.

15
CONSIGNES DE SÉCURITÉ IMPORTANTES
CONSERVER CES CONSIGNES
• L’utilisation d’appareils électriques nécessite des précautions
de base qu’il faut toujours prendre
• Lampe UV en marche; avant d’entretenir ou de neoyer
l’appareil, coupez l’alimentation depuis le tableau de service
et verrouillez les dispositifs de sectionnement pour éviter
que l’alimentation ne soit accidentellement allumée; s’il est
impossible de verrouiller les dispositifs de sectionnement,
fixez solidement un témoin d’avertissement, tel qu’une
étiquee, au tableau de service
• Pour réduire les risques d’incendie, de décharge électrique
ou de blessure corporelle, veuillez respecter les procédures
suivantes:
MISE EN
GARDE
Lisez entièrement ce manuel avant d’utiliser votre ActivePure®Transit Guardian – Externe.
Tenir hors de la portée des enfants.
• Utiliser seulement de la façon prévue par le fabricant. En cas de questions, veuillez
contacter ActivePure
• NE PAS essayer de réparer ou d’ajuster l’une des fonctions électriques ou mécaniques de
l’appareil
• Le travail d’installation et le filage électrique doivent être faits par une ou des personne(s)
qualifiée(s), selon tous les codes et normes applicables, incluant la construction
résistante au feu
• Lorsque vous percez un mur, N’ENDOMMAGEZ AUCUN câble électrique
• NE PAS utiliser ce ventilateur avec un réglage de vitesse à semi-conducteurs
• NE PAS utiliser l’appareil à l’extérieur ou sur des surfaces humides
• Cet appareil ne doit pas être utilisé comme un jouet; NE PAS laisser les enfants s’en
approcher
• NE PAS manipuler l’appareil avec des mains humides
• NE PAS laisser des objets étrangers entrer dans les orifices de ventilation
• Tenir les cheveux, les vêtements, les doigts et toute partie du corps à l’écart des orifices
• Pour réduire le risque de décharges électriques, NE PAS exposer cet appareil à l’eau ou
la pluie
ATTENTION
Le travail d’installation et le filage électrique doivent être faits
par une ou des personne(s) qualifiée(s), selon tous les codes et
normes applicables, incluant la construction résistante au feu.

16
POUR LES CLIENTS AU CANADA SEULEMENT
ACTIVEPURE®TRANSIT GUARDIAN EXTERNE
Numéro de série: 00775
Ce modèle à rayons UV permet de réduire la propagation des virus dans l’air.
Tenir hors de la portée des enfants.
Veuillez lire l’étiquee et le manuel d’utilisation avant de l’utiliser:
www.activepure.com/manuals
PRÉCAUTIONS:
MISE EN GARDE: Cet appareil émet des rayonnements UV. L’utilisation involontaire de cet
appareil ou un boîtier endommagé peut entraîner l’exposition à des rayons ultraviolets. Les
rayonnements ultraviolets peuvent irriter les yeux et la peau. Évitez d’exposer vos yeux et votre
peau aux rayons ultraviolets.
INSTRUCTIONS POUR LES PREMIERS SOINS: Veuillez contacter votre professionnel de la
santé en cas de blessure causée par cet appareil.
MODE D’EMPLOI:
Le travail d’installation et le filage électrique doivent être faits par une ou des personne(s)
qualifiée(s), selon tous les codes et normes applicables, incluant la construction résistante au
feu. Veuillez consulter le manuel d’utilisation pour des informations détaillées sur l’utilisation,
la manipulation, le stockage et la mise au rebut de l’appareil, et les procédures pour réduire
tout risque connexe.
L’utilisation de cet appareil agit en complément des pratiques standards de contrôle des
infections et ne représente donc pas un moyen de substitution à celles-ci. Les utilisateurs
doivent continuer à suivre toutes les pratiques standards actuelles en matière de contrôle
des infections, y compris celles concernant le neoyage et la désinfection des surfaces
environnantes.
POUR TOUTE QUESTION, VEUILLEZ CONTACTER:
AERUS CANADA, INC.
Laird Business Park
3480 Laird Road, Units 2 – 5
Mississauga (Ontario) L5L 5Y4 Canada
W. Parrell,
Responsable
(905) 569-9399
wparrell@aerusonline .com
Aerus Canada, Inc. est ailiée à ActivePure Manufacturing, LLC
1300 Valley Drive, Bristol, VA 24201

17
INSPECTION
1. Retirez l’appareil de son carton d’emballage.
2. Retirez toutes les protections.
3. Vérifiez qu’aucune pièce n’est manquante ou endommagée à cause du transport.
4. Lisez aentivement le Manuel d’utilisation avant l’installation.
5. Choisissez l’emplacement de l’appareil, en suivant les instructions
d’installation à la page 19.

18
PIÈCES
Orifice
d’aération
Ventilateur (2)
Assemblage
du ballast
Cellule ActivePure
Connecteur 4 broches
Couvercle

19
L’ActivePure®Transit Guardian — Externe est conçu pour être fixé sur un mur, un plafond
ou un sol, aussi haut que possible. L’installateur est responsable de choisir et d’utiliser le
mode de fixation qui convient pour fixer solidement l’appareil.
1. Branchez le cordon électrique 12 VCC aux fils noir et blanc de l’ActivePure Transit
Guardian - Externe conformément aux codes locaux ou nationaux.
2. Servez-vous de la prise électrique de l’appareil international pour fixer le câblage au
couvercle.
INSTALLATION
Supports de fixation
Vue arrière de l’appareil
Connexion électrique
Prise 2
broches
Brancher vers micro
Fils bleus
Fils rouges
Cellule ActivePure
Interrupteur
de sécurité Ventilateur Ventilateur
Ballast
Coinceur à
câble
Fils rouges
Assemblage
des fils
Coinceur à
câble
Fils noirs
Interrupteur vers ballast
ATTENTION
Le travail d’installation et le filage électrique doivent être faits
par une ou des personne(s) qualifiée(s), selon tous les codes et
normes applicables, incluant la construction résistante au feu.

20
Le seul entretien requis pour l’ActivePure®Transit Guardian — Externe est le remplacement
de la cellule ActivePure. Nous recommandons de remplacer la cellule ActivePure chaque
année.
1. Coupez l’alimentation électrique de l’appareil.
2. Retirez les quatre (4) vis du couvercle et éloignez-le de l’appareil en le glissant. Voir fig. 1
3. Débranchez le connecteur 4 broches de la cellule ActivePure (fils bleus et rouges).
Voir fig. 2
4. Retirez les quatre (4) boulons des supports de fixation de la cellule ActivePure et retirez
la cellule. Voir fig. 2
5. Nous recommandons de passer l’aspirateur sur les orifices d’aération pour retirer tout
amas de poussière. Voir fig. 3
REMARQUE : Il est conseillé de porter un masque pour éviter d’inhaler toute particule
relâchée dans l’air pendant cee étape. Il est également conseillé de
porter une protection pour les yeux.
• L’entretien ne devrait être eectué que par un électricien
qualifié
• Assurez-vous que l’alimentation de l’appareil est coupée
à la source
MISE EN
GARDE
ENTRETIEN
Couvercle
Vis (4)
Fig. 1 Fig. 2 Ventilateur (2)
Orifice
d’aération
This manual suits for next models
2
Table of contents
Languages:
Other ActivePure Air Cleaner manuals

ActivePure
ActivePure F159L User manual

ActivePure
ActivePure Guardian Pro User manual

ActivePure
ActivePure Induct Guardian I User manual

ActivePure
ActivePure TRANSIT GUARDIAN B101A User manual

ActivePure
ActivePure Surface & Air Guardian User manual

ActivePure
ActivePure Surface & Air Guardian User manual

ActivePure
ActivePure GUARDIAN AIR User manual

ActivePure
ActivePure INDUCT GUARDIAN IV User manual

ActivePure
ActivePure Beyond Guardian User manual

ActivePure
ActivePure INDUCT GUARDIA N II User manual