ActivePure TRANSIT GUARDIAN B101A User manual

TRANSIT GUARDIAN
COMMERCIAL VEHICLE
AIR PURIFICATION SYSTEM
READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION.

2
PRODUCT OVERVIEW
Congratulations on your purchase! Your new ActivePure®Transit Guardian utilizes tested
ActivePure Technology to reduce odors and contamination on surfaces. It is designed to be
installed inside the ductwork of a vehicle heating and air conditioning system or inside of a
secondary/ addon air system. Be sure to read and follow all service procedures outlined in
this owner’s manual, and use only genuine ActivePurereplacement parts.
GENERAL INFORMATION
CONTENTS
Product Overview ....................... 2
Specifications ........................... 2
Storage & Disposal ...................... 2
Important Safety Instructions............ 3
For Canadian Customers Only ........... 4
Inspection............................... 5
Installing the Unit........................ 6
Changing the ActivePure Bulb............ 8
Parts View...............................10
Cleaning and Maintenance...............11
Replacement Parts & Service ............12
Warranty Information ....................12
FCC Declaration & Responsible Party ....13
STORAGE AND DISPOSAL
Do not dispose of this product as household
waste. Electrical waste and electronic
products should be appropriately recycled as
required by practices established by your
local authority.
SPECIFICATIONS
ActivePure Transit Guardian
• Model No. : B101A
• Sales No. : 00760
Technology :
• ActivePure
Electrical :
• Input Voltage : 12 Volts DC; 0.8A
• Negative Ground
• UL1995, CSA C22.2 No. 236-15
Mechanical :
• Distribution via air handler
Weight & Dimensions :
• 1.95 lbs (.88 kg)
• 14.25” L x 2.12” H x 2.5” D
(362 mm x 53.8 mm x 63.5 mm)
*Dimensions are without mounting
brackets aached. Mounting is
optional.
Operating Temperature :
• 34°F – 200°F (1.6°C – 93°C)
Recommended Max. Coverage in
a Contiguous Space :
• Every facility is unique and proper
configuration is an important as the
technology. To validate coverage
in your facility, speak to your sales
representative or call customer
service at 800-572-1446.
Warranty :
• Limited Five (5) Year Warranty
ActivePure reserves the right to change or
modify any specification without notice.
If you have any questions concerning
this, or any ActivePure product, contact
ActivePure Customer Service at
800.572.1446 M-F 9:00 am - 7:00 pm ET or
email customerservice@ActivePure.com.

3
SAVE THESE INSTRUCTIONS
Read this manual in its entirety before using your ActivePure Transit Guardian.
Keep out of reach of children.
• For commercial use only
• DO NOT insert or allow foreign objects to enter any ventilation or exhaust
opening as this may cause an electric shock or fire, or damage the air cleaner
• To prevent a possible fire, DO NOT block the air intakes or exhaust in any
manner; DO NOT use where openings may become blocked
• DO NOT use outdoors or on wet surfaces
• DO NOT aempt to repair or adjust any electrical or mechanical functions
on this unit, doing so will void your warranty
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
Hg — LAMP CONTAINS MERCURY. Manage in accordance
with local laws.
• Be sure power to the air system is o before installing
the ActivePure®Transit Guardian
• It is recommended that this unit be installed by an
appropriate, licensed installer for the type of installation
selected, to ensure to ensure proper installation and
protect your warranty
• UV Lamp in operation; DO NOT operate unless the unit is
completely and correctly assembled; failure to comply
may result in serious eye damage
• When using electrical appliances, basic precautions
should always be followed to reduce risk of fire, electric
shock, and injury to persons, including the following:
WARNING

4
ACTIVEPURE®TRANSIT GUARDIAN
Sales No. : 00760
This UV device helps reduce the spread of viruses in the air.
Keep out of the reach of children.
Please read the label and owner's manual before using: www.activepure.com/manuals
PRECAUTIONS:
WARNING: UV radiation emied from this device. Unintended use of the device, or damage
to the housing, may result in exposure to ultraviolet radiation. Ultraviolet radiation may
cause eye and skin irritation. Avoid exposing eyes and skin to ultraviolet radiation.
FIRST AID INSTRUCTIONS: Please contact your healthcare provider in the event of injury
caused by this device.
DIRECTIONS FOR USE:
Installation will require access to the vehicle air conditioning system or air ducting. Because
transit vehicles vary, installation and location of installation may vary. Please see owner's
manual for detailed instructions on using, handling, storing and disposing of the device, and
procedures to mitigate any associated risks.
The use of this device is a supplement to and not a substitute for standard infection control
practices; users must continue to follow all current infection control practices, including
those related to the cleaning and disinfection of environmental surfaces.
FOR INQUIRIES CONTACT:
AERUS CANADA, INC.
Laird Business Park
3480 Laird Road, Units 2–5
Mississauga, Ontario, Canada, L5L 5Y4
W. Parrell, Manager
(905) 569-9399
Aerus Canada, Inc. is ailiated with ActivePure Manufacturing, LLC
1300 Valley Drive, Bristol, Virginia 24201
FOR CANADIAN CUSTOMERS ONLY

5
INSPECTION
1. Remove unit from shipping carton.
2. Remove all protective materials.
3. Check for missing or broken parts due to shipping damage.
4. Read Owner’s Manual thoroughly prior to installation.
5. Determine placement location for the unit, follow installation
instructions on page 6 and 7.
Screw (3)
Safety Switch
Plug
ActivePure® Transit
Guardian unit
Fuse
w/ Fuse Cap

6
• Be sure power to the air system is o before installing
the ActivePure®Transit Guardian
• It is recommended that this unit be installed by an
appropriate, licensed installer for the type of installation
selected, to ensure to ensure proper installation and protect
your warranty
WARNING
INSTALLING THE UNIT
1. Installation will require access to the
vehicle air conditioning system or air
ducting. Because transit vehicles vary,
installation and location of installation
may vary. Location of installation is
typically in the ducting or at the coils
aer the filter. Always verify where in the
air path the unit will be placed.
3. The ActivePure Transit Guardian should
be placed in the direct air flow. Optimum
placement will allow air to pass into the
unit from one side and exit the opposite
side (see diagram).
2. Secure unit in air conditioning unit or
duct using the provided screws. Multiple
mounting holes are provide on boom
plate. Depending on where and how it’s
mounted, not all the mounting holes
may be used.
Mounting Holes
ActivePure®Matrix
(Honeycomb)

7
INSTALLING THE UNIT (CONTINUED)
4. Connect the 12 VDC power supply cable
by inserting the plug into the power
inlet. Make sure the power cable is
locked securely to the mating part.
5. Mount the safety switch in an
appropriate location that would disable
power to the unit when accessing it. The
switch can be mounted in any location.
Optimum placement would be behind
an access door, panel or cover.
6. Connect the unit to a 12 VDC negative
ground electrical power source (see
diagram). It’s recommended to connect
it to a circuit that is turned on and o
by the vehicle to prevent the unit from
being le on and running the vehicle
baery down.
ActivePure®Matrix
(Honeycomb)
TRANSIT
UNIT
FUSE
N.O. SAFETY SWITCH
12 VOLT DC CONNECT TO
APPROPRIATE
12V ON
VEHICLE
BLACK –
RED +
Plug
Safety
Switch

8
CAUTION
Disconnect power from the ActivePure Transit Guardian
before servicing.
UV Light in operation; disconnect unit from power source before
servicing; failure to follow warnings may result in severe eye
damage and electrical shock.
CHANGING THE ACTIVEPURE®BULB
WARNING
1. Remove the three (3) screws from the
cover. One on top and two on the side.
2. Remove the cover by liing away from
the base.
3. Remove the UV bulb by liing the end
away from the bulb retaining clamp.
*Two pieces of honeycomb removed for clarity.
4. Unplug the UV bulb from the power
supply.

9
CHANGING THE ACTIVEPURE®BULB (CONTINUED)
5. Replace the UV bulb by reversing steps
3 and 4. Wipe new bulb with isopropyl
alcohol to remove oils from fingerprints.
6. Return cover and replace screws.
NOTE: For optimal performance and to keep warranty in eect, it is required to replace
the ActivePure®Cell once every year, even if the UV lamp appears to be
operating normally.

10
PARTS VIEW
Screw
Cover
Honeycomb
(Side) Honeycomb (Top)
Bulb
Ballast Assembly
Bulb Plug
on Ballast
Safety Switch
Bracket
Wire Assembly
4FT Red 20 AWG
Wire Assembly
4FT Red 20 AWG
Female Connector
Hex Nuts
Plug
Assembled Base

11
CLEANING AND MAINTENANCE
1. Disconnect the power supply to the ActivePure®Transit Guardian.
2. Remove the ActivePure Transit Guardian unit.
3. Wipe the cover of the ActivePure Transit Guardian with a slightly damp cloth, not wet
cloth. Do not allow water to enter unit.
4. Use a vacuum with a hose aachment to vacuum dust from the ActivePure Matrix
(Honeycomb) on either side of the ActivePure Transit Guardian.
5. Determine placement location for the unit, follow installation instructions
on page 6 and 7.
6. Reinstall the ActivePure Transit Guardian back inside the vehicle air conditioning
system and reconnect it to the power.
NOTE: It is recommended to vacuum the ActivePure Matrix (Honeycomb)
surface as needed.
ActivePure Matrix
(Honeycomb)
CAUTION
Disconnect power from the ActivePure Transit Guardian before
cleaning and maintenance.

12
REPLACEMENT PARTS & SERVICE
REPLACEMENT PARTS QTY PART NUMBER
Safety Switch Assembly 50220
Ballast Assembly 50219
ActivePure®Cell Replacement Kit 50218
To order replacement parts, contact your sales representative or ActivePure
Customer Service for further assistance at 800.572.1446 M-F 9:00 am - 7:00 pm ET
or email customerservice@ActivePure.com.
WARRANTY INFORMATION
Limited Five (5) Year Warranty
To register your ActivePure®Transit Guardian unit, visit www.activepure.com/warranty.
To view full details on warranty coverage, visit www.activepure.com/manuals.
If you have any questions concerning this, or any ActivePure product, contact
ActivePure Customer Service at 800.572.1446 M-F 9:00 am - 7:00 pm ET
or email customerservice@ActivePure.com.

13
FCC DECLARATION OF CONFORMITY
Name: ActivePure®Transit Guardian
Model: B101A
Produced by: ActivePure Manufacturing, LLC
This device complies with Part 15
of the FCC Rules.
RESPONSIBLE PARTY
ActivePure Manufacturing, LLC
1300 Valley Drive
Bristol, VA 24201
Ph: 800.572.1446
Signature:
Printed Name: Andrew Eide
Title: Vice President of Product Development
and Manufacturing
Date: 03/21/22
FCC DECLARATION & RESPONSIBLE PARTY
This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to 15 of the FCC Rules. These
limits are designed to provide reasonable
protection against harmful interference when
the equipment is operated in a commercial
environment. This equipment may generate,
use, or could radiate radio frequency energy
and, if not installed and used in accordance
with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential
area is likely to cause harmful interference, in
which case the user will be required to correct
the interference at their own expense.

APTG_OM_65-00830_VA-01613
ActivePure Manufacturing, LLC | 1300 Valley Drive | Bristol, VA 24201 | 800.572.1446
Assembled in U.S.A. | © ActivePure Manufacturing, LLC. All Rights Reserved
For information regarding the use of this product,
please call Customer Service. 1.800.572.1446 or email at
customerser[email protected]
www.activepure.com
™
14

TRANSIT GUARDIAN
LIRE ATTENTIVEMENT LE MANUEL AFIN D’UTILISER
CORRECTEMENT L’APPAREIL ET D’ASSURER SON
FONCTIONNEMENT OPTIMAL.
SYSTÈME DE PURIFICATION DE L’AIR
POUR VÉHICULE COMMERCIAL

APERÇU DU PRODUIT
Félicitations pour votre nouvel achat! Votre nouveau ActivePure®Transit Guardian utilise
la technologie ActivePure pour réduire les odeurs et la contamination des surfaces. Ce
dispositif est conçu pour être installé à l’intérieur des conduits d’un système de chauage
et de climatisation de véhicule, ou à l’intérieur d'un système de ventilation secondaire/
supplémentaire. Assurez-vous de lire et de suivre toutes les procédures d’entretien décrites
dans ce manuel d’utilisation, et de n’installer que les pièces de rechange d’origine ActivePure.
INFORMATIONS GÉNÉRALES
SOMMAIRE
Aperçu du Produit .......................16
Spécifications ...........................16
Entreposage et Élimination ..............16
Consignes de Sécurité Importantes ......17
Pour le Canada Seulement.............. 18
Inspection.............................. 19
Installation de l’unité.................... 20
Remplacement de l’ampoule ActivePure.22
Illustration des Pièces .................. 24
Neoyage et Entretien .................. 25
Pièces de Rechange et Réparation ...... 26
Informations Relatives à la Garantie . . . . . 26
Déclaration FCC et Partie Responsable .27
SPÉCIFICATIONS
ActivePure Transit Guardian
• Numéro de Modèle : B101A
• Numéro de Commande : 00760
Technologie :
• ActivePure
Données Électriques :
• Tension d’entrée : 12 Volts CC; 0,8A
• Masse Négative
• UL1995, CSA C22.2 No. 236-15
Mécanique :
• Distribution par une unité de
traitement de l’air
Poids et Dimensions :
• 1,95 lbs (0,88 kg)
• L 14,25 po x H 2,12 po x P 2,5 po
(362 mm x 53,8 mm x 63,5 mm)
*Dimensions fournies sans les supports
de montage. Montage facultatif.
Température de Fonctionnement :
• 34 à 200 °F (1,6 à 93 °C)
Couverture maximale recommandée
dans un espace contigu :
• Chaque système étant diérent,
une configuration correcte est aussi
importante que la technologie. Pour
valider la couverture de votre
système, veuillez contacter votre
représentant commercial ou
téléphoner au service à la clientèle au
800 572-1446.
Garantie :
• Garantie limitée de cinq (5) ans
ActivePure se réserve le droit de modifier des
spécifications sans préavis.
ENTREPOSAGE ET ÉLIMINATION
Ne pas jeter ce produit avec les ordures
ménagères. Les déchets électriques et les
produits électroniques doivent être
recyclés de manière appropriée,
conformément aux pratiques établies par
les autorités locales.
Si vous avez des questions concernant cet
appareil ou un autre produit ActivePure,
contactez le service à la clientèle ActivePure
au 1-800-572-1446 M-F 9:00 am - 7:00 pm ET,
ou par courriel à l’adresse
16

17
ATTENTION
LA LAMPE — HG CONTIENT DU MERCURE. Gérer l’élimination
conformément aux lois pertinentes.
• S’assurer de couper l’alimentation électrique du système de
ventilation avant d’installer le système ActivePure®Transit
Guardian
• Il est recommandé que cet appareil soit installé par un
entrepreneur agréé pour le type d’installation choisi, afin
d’assurer la qualité du travail et de protéger votre garantie
• Lampe UV en marche; NE PAS utiliser cet appareil s’il n’est pas
complètement et correctement assemblé; des lésions
oculaires graves peuvent survenir si cee mise en garde n’est
pas respectée
• Lors de l’utilisation d’un appareil électrique, des précautions de
base doivent toujours être respectées pour réduire les risques
d’incendie, de choc électrique ou de blessure corporelle, y
compris les directives suivantes:
MISE EN
GARDE
CONSERVER CES CONSIGNES
Veuillez lire ce manuel dans son intégralité avant d’utiliser votre appareil ActivePure
Transit Guardian.
Tenir hors de portée des enfants.
• Réservé à un usage commercial
• NE PAS introduire ni laisser pénétrer d’objets étrangers dans une ouverture de
ventilation ou de sortie, au risque de provoquer un choc électrique ou un incendie,
ou d’endommager le purificateur d’air
• Pour éviter tout risque d’incendie, NE PAS bloquer les entrées ou les sorties d’air de
quelque manière que ce soit; NE PAS utiliser l’appareil à un endroit où les ouvertures
risqueraient de bloquer
• NE PAS utiliser l’appareil à l’extérieur ou sur des surfaces humides
• NE PAS essayer de réparer ou d’ajuster les fonctions électriques ou mécaniques de
cet appareil; votre garantie en serait annulée.
CONSIGNES DE SÉCURITÉ IMPORTANTES

ACTIVEPURE®TRANSIT GUARDIAN
Numéro de commande: 00760
Ce modèle à rayons UV permet de réduire la propagation des virus dans l’air.
Garder hors de la portée des enfants.
Veuillez lire l’étiquee et le guide d’utilisation avant de commencer à utiliser le produit
(en anglais seulement): www.activepure.com/manuals
PRÉCAUTIONS:
MISE EN GARDE: Cet appareil émet des rayonnements UV. L’utilisation involontaire de cet
appareil ou un boîtier endommagé peuvent entraîner l’exposition à des rayons ultraviolets.
Les rayonnements ultraviolets peuvent irriter les yeux et la peau. Évitez d’exposer vos yeux
et votre peau aux rayons ultraviolets.
INSTRUCTIONS POUR LES PREMIERS SOINS: Veuillez contacter votre professionnel de
la santé en cas de blessure causée par cet appareil.
MODE D’EMPLOI:
L’installation devra avoir accès au système d’air conditionné du véhicule ou aux conduites
d’aération. Puisque les véhicules de transport en commun ne sont pas tous pareils,
l’installation et son emplacement peuvent varier. Veuillez consulter le manuel d'utilisation
pour obtenir des instructions détaillées concernant l'utilisation, la manipulation, le
stockage et la mise au rebut de l'appareil, ainsi que les procédures à suivre pour réduire les
risques associés.
L’utilisation de cet appareil agit en complément des pratiques standards de contrôle des
infections et ne représente donc pas un moyen de substitution à celles-ci. Les utilisateurs
doivent continuer à suivre toutes les pratiques standards actuelles en matière de contrôle
des infections, y compris celles concernant le neoyage et la désinfection des surfaces
environnantes.
POUR TOUTE QUESTION, VEUILLEZ CONTACTER:
AERUS CANADA, INC.
Laird Business Park
3480 Laird Road, Unités 2–5
Mississauga, Ontario, Canada, L5L 5Y4
W. Parrell, Gestionnaire
(905) 569-9399
Aerus Canada, Inc. est ailié à ActivePure Manufacturing, LLC
1300 Valley Drive, Bristol, Virginia 24201
POUR LE CANADA SEULEMENT
18

19
INSPECTION
1. Déballer l’appareil de son carton d’expédition.
2. Retirer tous les matériaux de protection.
3. Vérifier l’absence de pièces desserrées ou brisées dues à des dommages de transport.
4. Lire aentivement le manuel d’utilisation avant l’installation.
5. Déterminer l’emplacement adéquat pour l’appareil; se référer aux instructions
d’installation à la page 22 du manuel d’utilisation.
Vis (3)
Interrupteur
de sécurité
Fiche
Appareil
ActivePure® Transit
Guardian
Fusible avec
capuchon

• S’assurer de couper l’alimentation électrique du système de
ventilation avant d’installer le système ActivePure®Transit
Guardian
• It is recommended that this unit be installed by an
appropriate, licensed installer for the type of installation
selected, to ensure to ensure proper installation and protect
your warranty
MISE EN
GARDE
INSTALLATION DE L’UNITÉ
1. Cee installation nécessite l’accès
au système de climatisation ou aux
conduits d’air du véhicule. Étant donné
les diérences entre les véhicules de
transport en commun, l’installation et
l’emplacement d’installation peuvent
varier. Cee installation s’eectue
généralement sur un conduit ou au
niveau des serpentins, en aval du filtre.
Vérifier toujours où sera placée l’unité
dans le circuit d’air.
3. L’unité ActivePure Transit Guardian
doit être placée directement dans le
flux d’air. Un positionnement optimal
permerait à l’air de pénétrer par un
côté de l’appareil et d’en ressortir par le
côté opposé (voir schéma).
2. Monter l’appareil sur l’unité de
climatisation ou sur le conduit à l’aide
des vis fournies. Plusieurs trous de
fixation sont prévus sur la plaque
inférieure. Selon l’emplacement choisi
pour l’installation, certains trous de
fixation peuvent ne pas être utilisés.
Trous de montage
Matrice ActivePure®
(nid d’abeille)
20
Table of contents
Languages:
Other ActivePure Air Cleaner manuals

ActivePure
ActivePure Surface & Air Guardian User manual

ActivePure
ActivePure Beyond Guardian User manual

ActivePure
ActivePure Transit Guardian External User manual

ActivePure
ActivePure GUARDIAN AIR User manual

ActivePure
ActivePure Surface & Air Guardian User manual

ActivePure
ActivePure Guardian Pro User manual

ActivePure
ActivePure Induct Guardian User manual

ActivePure
ActivePure INDUCT GUARDIA N II User manual

ActivePure
ActivePure Induct Guardian I User manual

ActivePure
ActivePure INDUCT GUARDIAN IV User manual