ADTRAN 3192 User manual

HTU-C / 3192
CLEI: T1L4SNSC_ _
JOBAID
61245004L6-22B
0104
CIRCUIT BOARD ROTARY SWITCH - SW2
Selects the DSX-1 Line Build Out
■0..........0 - sets LBO to 0-133 feet
■1..........133 - sets LBO to 133-266 feet
■2..........266 - sets LBO to 266-399 feet
■3..........399 - sets LBO to 399-533 feet
■4..........533 - sets LBO to 533-655 feet
Note: Positions 5,6 & 7 are not used.
CIRCUIT BOARD JUMPER - P1
Selects the span powering voltage
LV (–140 Vdc)
■Used to span power circuit with 0 or 1 HRE
HV (–190 Vdc)
■Used to span power circuit with multiple HREs
CIRCUIT BOARD JUMPER - P3
Selects the framing of the HDSL circuit
UNF
■HTU-C operates in unframed mode
AUTO
■HTU-C auto detects framing
DSX EQ BANTAM JACKS
Provides an intrusive test access point to the data stream
TX
■Accesses the data stream being received from the local loop
RX
■Accesses the data stream being transmitted to the local loop
RS-232 DB-9 CONNECTOR
■Used to access performance monitoring data, perform loopbacks and provision units
via VT100 emulation software such as Hyper Terminal – Private Edition and
ProComm Plus.
■Provision terminal port as follows:
Data Rate — 19.2 kbps
Asynchronous Data Format — eight data bits, no parity (none), one stop bit
■When using a PC with terminal software, be sure to disable any power saving
programs.
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied
under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of
ADTRAN’s U.S. Carrier Networks Equipment Warranty:
(877) 457-5007, Document #414.
TX
RX
HTU-C
1245004L6
LP1
H
D
S
LLP2
DSX
ALM
LBK
EXT ALM
LBK
TM OUT
DIS
BZS
T1
DIS
EN
AMI
FT1
EN
R
S
2
3
2
C
L
O
S
AIS
LBK
CDI
HTU-C / 3192
STATUS LEDs
LP1 / LP2 ●●OFF No synchronization between the HTU-C and the next
HDSL unit (HRE or HTU-R) on loop1 / loop2
●RED Poor signal quality on loop1 / loop2
●YELLOW Marginal signal quality loop on loop1 / loop2
●GREEN Good signal quality on loop1 / loop2
✷FLASHING Error detected at HTU-C or HTU-R
DSX ●●OFF DSX-1 signal not detected
✷FLASHING BPV, Frame Error (SF), CRC Error (ESF) is detected
●GREEN DSX-1 signal is present and synchronized
ALM ●●OFF No alarm condition detected
●RED Local alarm condition detected (HTU-C), or local and
remote alarm condition detected (HTU-C and HTU-R)
●YELLOW Remote alarm condition detected (HTU-R)
LBK ●●OFF No active loopback
✷FLASHING Armed but not in loopback
●YELLOW Local loopback is active
FACEPLATE SWITCH - SW1
Selects response of HTU-R upon Customer Loss of Signal
AIS
■HTU-R generates unframed all 1s toward network upon loss of customer signal
LBK
■HTU-R generates loopback towards network upon loss of customer signal
CDI
■HTU-R generates framed all 1s toward network upon loss of customer signal
FACEPLATE SWITCH - SW3
Loopback Timeout
Enabled
■Loopback timeout is enabled
Disabled
■Loopback timeout is disabled
Manual Line Code Select
AMI
■AMI line code is selected
B8ZS
■B8ZS line code is selected
Latching Loopback
T1
■Allows only standard T1 testing
FT1
■Allows for fractional T1 testing
External Alarm
Enabled
■External alarm is enabled
Disabled
■External alarm is disabled
COMPLIANCE CODES
This product complies with UL 1459, third
edition. It is intended to be installed in an
enclosure with an Installation Code (IC) of
“B” or “E” and in Restricted Access Locations
only. Input current at maximum load is 1 A,
and maximum output at overcurrent condi-
tion is 160 mA at -188 Vdc.
Code Input Output
Installation Code (IC) A –
Telecommunication Code (TC) – X
Power Code (PC) F C
For complete Installation and Maintenance: (877) 457-5007, Document #300. Please have your fax number available.
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
INSERTION LOSS MEASUREMENTS
10000 15.00
50000 25.50
100000 30.00
150000 32.75
196000 35.00
200000 35.25
NOTE: If your TIMs is unable to transmit 200 kHz tone,
set the TIMs to one of the frequencies shown above and
compare the received signal to the maximum loss at that
frequency.
Turn-up Guide
1. Set option switches according to circuit design and local practice.
2. Install HTU-C and HTU-R.
3. See reverse side of this job aid to ensure all LEDs are correct and synchronization has occurred.
a) HTU-C will have red ALM LED if not connected to network. LP1 and LP2 should be solid
green.
b) HTU-R will have red ALM LED if no customer connected. LP1, LP2, line coding and framing
(if not UNFR) LEDs should be illuminated.
4. If all LEDs are correct:
a) Verify that the signal quality is the same on each loop. Ensure signal quality indicators do
not fluctuate.
b) Verify that the loop loss is within design limits. If there is a difference of more than 1 dB
between the two loops, a problem exists with the cable pairs.
c) If errors occur, use the Current System Status and Performance History screens to determine
where they are occurring. See Troubleshooting Guide section.
5. If everything checks out, proceed with BERT testing.
Troubleshooting Guide
The HTU-C DSX LED is Flashing, but no Errors are Indicated by the HTU-R
■A BPV, Frame Error (SF) or CRC Error (ESF) has been detected at the DSX-1 interface. Possible network
or wiring problem between the HTU-C and the DSX. This is not an indication of problems on the
HDSL loops.
The HTU-R DS1 LED is Flashing, but no Errors are Indicated by the HTU-C
■A BPV, Frame Error (SF) or CRC Error (ESF) has been detected at the DS1 interface. This indicates a
wiring problem or a B8ZS/AMI mismatch between the HTU-R and the customer equipment. This
is not an indication of problems on the HDSL loops.
Frequency Maximum
(kHz) Loss Data (dB)
The HTU-R has Power, but LP1 and LP2 LEDs are Dark. The Unit cannot Sync with the HTU-C
■Simplex power for powering the HTU-R can be passed over cable pairs that contain load coils or
that are too long for HDSL synchronization. Using a TIMs, verify the circuit is within design limits.
■The HTU-R will power up as long as there is at least one good conductor on each loop. To test,
remove the protector plug at the MDF and measure t-r resistance to the HTU-R on both loops.
The HTU-R will place a 3 ohm short between t-r on both loops. An extremely high impedance
indicates an open conductor. An extremely low reading on one loop may indicate a t-r short in
the field. In the field, measure t-t and t-r voltage with the HTU-C installed and compare to the
chart above. If these voltages are not present, open pairs or mis-wiring is indicated. As with other
circuits, standard resistance measurements between each conductor and ground should also be
used to test for a grounded conductor.
■If the HTU-C is optioned for LV and there are two HREs in the circuit, the HTU-R could fail to
power up normally. The LEDs on the HREs or HTU-R will flash at a rate of 3 times/second. Make
sure the voltage option on the HTU-C is set to HV.
■A high resistance open which degrades to the point that it causes the circuit to lose sync can
be “resealed” by reseating the HTU-C. Test the cable pairs before reseating the HTU-C.
Running Excessive Errors on the Loop
■Measure t-r resistance as described above. If the pairs are unbalanced by more than 4 ohms, or
a measurement varies a great deal, this could indicate a high resistance open or an intermittent
fault on the loop with the higher measurement. A TDR is typically required to locate this splice
for repair.
■Excessively long bridged taps can also cause errors. Check the records and/or use a TDR to verify the
location and length of bridged taps.
■Using ADTRAN’s “Performance History” screen, it is often possible to see that many more errors
are being received on a particular loop or at a particular unit. The fault will typically be very close
to the unit receiving the most errors.
No Power at the HTU-R
■This could be caused by a loop with two open conductors. Measure t-r resistance from the MDF
to the HTU-R or use the voltage chart to see which pair is open.
■Check the HV/LV option on the HTU-C and re-option if necessary.
HTU-C VMDF HRE 1 HRE2 HTU-R
AB CD EF
t-t Voltage t-t Voltage t-t Voltage t-t Voltage t-t Voltage t-t Voltage
Open at Frame HV 185 - 190 N/A N/A N/A N/A N/A
Open at Frame LV 145 - 150 N/A N/A N/A N/A N/A
HTU-C LV / HTU-R 145 - 150 145 - 150 130 - 145 N/A N/A 125 - 130
HTU-C LV / HRE1 / HTU-R 130 - 135 110 - 135 110 - 135 N/A N/A 100 - 135
HTU-C HV / HRE 2 / HTU-R 185 - 190 160 - 185 160 - 185 140 - 185 140 - 185 130 - 185
NOTE: All measurements taken with HTU-C installed. With the HTU-C unseated or with protector removed at VMDF, t-r resistance will be cable resistance plus 3 ohms
(for either HRE or HTU-R).
TURN-UP & TROUBLESHOOTING GUIDE
Pricing and Availability 800.827.0807
Tech Support 800.726.8663
Return for Repair 256.963.8722
www.adtran.com
61245004L6-22B

Other manuals for 3192

3

This manual suits for next models

1

Other ADTRAN Network Hardware manuals

ADTRAN HTU Nx64 User manual

ADTRAN

ADTRAN HTU Nx64 User manual

ADTRAN FXS+ Dual User manual

ADTRAN

ADTRAN FXS+ Dual User manual

ADTRAN Octal IDSL DSLAM Octal IDSL User manual

ADTRAN

ADTRAN Octal IDSL DSLAM Octal IDSL User manual

ADTRAN OSU 300 User manual

ADTRAN

ADTRAN OSU 300 User manual

ADTRAN Total Access 5006 User manual

ADTRAN

ADTRAN Total Access 5006 User manual

ADTRAN Total Access 832 User manual

ADTRAN

ADTRAN Total Access 832 User manual

ADTRAN jobAid NETVANTA User manual

ADTRAN

ADTRAN jobAid NETVANTA User manual

ADTRAN U-BR1TE User manual

ADTRAN

ADTRAN U-BR1TE User manual

ADTRAN IQ 310 User manual

ADTRAN

ADTRAN IQ 310 User manual

ADTRAN E1 Instruction Manual

ADTRAN

ADTRAN E1 Instruction Manual

ADTRAN DDS-DP Product manual

ADTRAN

ADTRAN DDS-DP Product manual

ADTRAN jobAid+ 1200482G1 User manual

ADTRAN

ADTRAN jobAid+ 1200482G1 User manual

ADTRAN NetVanta 8044M User manual

ADTRAN

ADTRAN NetVanta 8044M User manual

ADTRAN GPON 452 User manual

ADTRAN

ADTRAN GPON 452 User manual

ADTRAN Total Access Octal ADSL User manual

ADTRAN

ADTRAN Total Access Octal ADSL User manual

ADTRAN NetVanta 1700801G1 User manual

ADTRAN

ADTRAN NetVanta 1700801G1 User manual

ADTRAN SFP+ User manual

ADTRAN

ADTRAN SFP+ User manual

ADTRAN ENHANCED PSD 239 H2R User manual

ADTRAN

ADTRAN ENHANCED PSD 239 H2R User manual

ADTRAN FNID Manual

ADTRAN

ADTRAN FNID Manual

ADTRAN Total Access 351 User manual

ADTRAN

ADTRAN Total Access 351 User manual

ADTRAN NetVanta E1/FE1 + G.703 Network Interface... User manual

ADTRAN

ADTRAN NetVanta E1/FE1 + G.703 Network Interface... User manual

ADTRAN Total Access 850 User manual

ADTRAN

ADTRAN Total Access 850 User manual

ADTRAN 500 Series User manual

ADTRAN

ADTRAN 500 Series User manual

ADTRAN NetVanta 7000 Series User manual

ADTRAN

ADTRAN NetVanta 7000 Series User manual

Popular Network Hardware manuals by other brands

Trend Micro Cloud Edge 100 G2 quick start guide

Trend Micro

Trend Micro Cloud Edge 100 G2 quick start guide

FireBrick FB2700 user manual

FireBrick

FireBrick FB2700 user manual

Cabletron Systems WPIM T1 user guide

Cabletron Systems

Cabletron Systems WPIM T1 user guide

Hypercom IEN 500 Technical specifications

Hypercom

Hypercom IEN 500 Technical specifications

Philips Dynalite DDPB22RJ12 instruction manual

Philips

Philips Dynalite DDPB22RJ12 instruction manual

Adeunis RF COMFORT LwM2M user guide

Adeunis RF

Adeunis RF COMFORT LwM2M user guide

Devolo Giga Bridge manual

Devolo

Devolo Giga Bridge manual

Interlogix TruVision NVR 50 quick start guide

Interlogix

Interlogix TruVision NVR 50 quick start guide

D-Link DIR-615 - Wireless N Router Installation

D-Link

D-Link DIR-615 - Wireless N Router Installation

D-Link DNS-321 - Network Storage Enclosure Hard Drive... Quick install guide

D-Link

D-Link DNS-321 - Network Storage Enclosure Hard Drive... Quick install guide

Balluff Easy Tool-ID BSG TID-05-T30-00-005 Installation and operation

Balluff

Balluff Easy Tool-ID BSG TID-05-T30-00-005 Installation and operation

Cradlepoint COR IBR900 Series quick start guide

Cradlepoint

Cradlepoint COR IBR900 Series quick start guide

Dahua NVR41 series user manual

Dahua

Dahua NVR41 series user manual

UeeVii CPE452 user manual

UeeVii

UeeVii CPE452 user manual

Cisco AIR-BR1410A-A-K9 - Aironet 1410 Wireless... Deployment guide

Cisco

Cisco AIR-BR1410A-A-K9 - Aironet 1410 Wireless... Deployment guide

Foxconn RAID user guide

Foxconn

Foxconn RAID user guide

Unitech MR055 Specifications

Unitech

Unitech MR055 Specifications

Compaq 312134-B21 - Intel Pentium II Xeon Processor... White paper

Compaq

Compaq 312134-B21 - Intel Pentium II Xeon Processor... White paper

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.