manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN OC-12 User manual

ADTRAN OC-12 User manual

This manual suits for next models

1

Other ADTRAN Network Hardware manuals

ADTRAN ATM Mini-DSLAM User manual

ADTRAN

ADTRAN ATM Mini-DSLAM User manual

ADTRAN SDX 611 GPON SFU ONT User manual

ADTRAN

ADTRAN SDX 611 GPON SFU ONT User manual

ADTRAN 1200864L1 User manual

ADTRAN

ADTRAN 1200864L1 User manual

ADTRAN Total Access 372 Product manual

ADTRAN

ADTRAN Total Access 372 Product manual

ADTRAN TA 900 User manual

ADTRAN

ADTRAN TA 900 User manual

ADTRAN IQ 310 User manual

ADTRAN

ADTRAN IQ 310 User manual

ADTRAN NxT1 HSSI/V-35 User manual

ADTRAN

ADTRAN NxT1 HSSI/V-35 User manual

ADTRAN NetVanta 8044M User manual

ADTRAN

ADTRAN NetVanta 8044M User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Total Access 334 User manual

ADTRAN

ADTRAN Total Access 334 User manual

ADTRAN DSU III AR User manual

ADTRAN

ADTRAN DSU III AR User manual

ADTRAN 4202023L5 User manual

ADTRAN

ADTRAN 4202023L5 User manual

ADTRAN NetVanta Series User manual

ADTRAN

ADTRAN NetVanta Series User manual

ADTRAN 1442880G1 User manual

ADTRAN

ADTRAN 1442880G1 User manual

ADTRAN TRACER 4x06 Reference manual

ADTRAN

ADTRAN TRACER 4x06 Reference manual

ADTRAN Express 3100 User manual

ADTRAN

ADTRAN Express 3100 User manual

ADTRAN DDS-DP Product manual

ADTRAN

ADTRAN DDS-DP Product manual

ADTRAN DSU IQ User manual

ADTRAN

ADTRAN DSU IQ User manual

ADTRAN Dual Nx56/64 User manual

ADTRAN

ADTRAN Dual Nx56/64 User manual

ADTRAN Total Access 362R User manual

ADTRAN

ADTRAN Total Access 362R User manual

ADTRAN T1 CSU ACE User manual

ADTRAN

ADTRAN T1 CSU ACE User manual

ADTRAN Total Access 300 Instruction Manual

ADTRAN

ADTRAN Total Access 300 Instruction Manual

ADTRAN SFP+ User manual

ADTRAN

ADTRAN SFP+ User manual

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

ADTRAN

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

Popular Network Hardware manuals by other brands

socomec SNMP Card II quick start guide

socomec

socomec SNMP Card II quick start guide

NVR SYSTEMS 4-CH user manual

NVR SYSTEMS

NVR SYSTEMS 4-CH user manual

Draytek VigorSwitch G1240 quick start guide

Draytek

Draytek VigorSwitch G1240 quick start guide

Westermo TD-34 LV installation manual

Westermo

Westermo TD-34 LV installation manual

LaCie Network Space MAX Quick install guide

LaCie

LaCie Network Space MAX Quick install guide

ZoneVu ZSI-450-IP Installation guide & user manual

ZoneVu

ZoneVu ZSI-450-IP Installation guide & user manual

QNAP Turbo NAS Application notes

QNAP

QNAP Turbo NAS Application notes

OpenEye MV Series quick start guide

OpenEye

OpenEye MV Series quick start guide

Huawei SmartAX MT880a quick start guide

Huawei

Huawei SmartAX MT880a quick start guide

Proxim Tsunami QuickBridge 2454-R installation guide

Proxim

Proxim Tsunami QuickBridge 2454-R installation guide

Bay Networks CLAM quick start guide

Bay Networks

Bay Networks CLAM quick start guide

Innodisk SATADOM-SH 3SE Series manual

Innodisk

Innodisk SATADOM-SH 3SE Series manual

Cisco CGR 1000 Series Getting connected guide

Cisco

Cisco CGR 1000 Series Getting connected guide

Matrix Switch Corporation MSC-HD161DEL product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DEL product manual

National Instruments NI 653x user manual

National Instruments

National Instruments NI 653x user manual

B&B Electronics ZXT9-IO-222R2 product manual

B&B Electronics

B&B Electronics ZXT9-IO-222R2 product manual

Yudor YDS-16 user manual

Yudor

Yudor YDS-16 user manual

D-Link ShareCenter DNS-320L datasheet

D-Link

D-Link ShareCenter DNS-320L datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

jobAid
DESCRIPTION
TheOC‐12SmallForm‐FactorPluggableCWDM1611nm(SFP
OC‐12)plugsintoADTRANOC‐12equipmentdesignedtoaccept
SmallForm‐factorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC‐12providesan
OC‐12CWDMinterfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPOC‐12:
♦SONETOC‐12compatible(622.08Mb/s)1611nm,
longreach,single‐mode,2‐fiberoperation
♦80kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦OpticalSpecifications:
◊Opticaltransmitlevel:–3dBmto+5dBm
◊Opticalreceivelevel:–28dBmto–8dBm
◊Powerpenalty:–1dB
◊Opticalbudget:24(±1)dBm
◊Minimumspanattenuation:13dB
◊Opticalconnectors:LC
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+65°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
OC-12 Small Form-Factor Pluggable
CWDM 1611 nm
INSTALLATION
ToinstalltheSFPOC‐12intoanappropriatemodule,complete
thefollowingsteps:
1. InspecttheSFPOC‐12.Ifdamaged,fileaclaimwiththecar‐
rierandthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC‐12intotheSFPcageonthemodule.
Ensurethatthemanufacturer’slabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheSFPOC‐12allthewayintothereceptacleuntil
thereisanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
The SFPOC‐12 is not directly provisionable. To provision the
SFPOC‐12, access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M
provided with the host module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheSFPOC‐12isNRTLListedtotheapplicableULstandards.
TheSFPOC‐12meetsorexceedsalltheapplicablerequirements
ofNEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.
TheSFPOC‐12isintendedfordeploymentinCentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC‐12istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
CLEI: SOOTAKVJ_ _
Product P/N: 1442703PG8
Issue Date: December 2010
Document P/N: 61442703PG8-22B
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442703PG8-22B*
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
C
TheSFPOC‐12containsaClass1laserthatcomplieswiththe
LaserSafetyrequirementsofFDA21CFR1040.10and1040.11,
andEN60825‐1,and‐2.TheSFPOC‐12isNRTLListedandCB
CertifiedtoallapplicableAmericanandEuropeansafety
standards.
CAUTION
!
♦ PerGR‐1089‐CORESection9,theSFPOC‐12 does not have
an internal DC connection between battery return and
frame ground.
♦ TheADTRANsystemthattheSFPOC‐12isbeingdeployedin
isdesignedandintendedforinstallationaspartofaCommon
BondingNetwork(CBN),orIsolatedBondingnetwork(IBN).
♦ TheSFPOC‐12canbeinstalledinaDC‐I(isolated)orDC‐C
(common)configuration.Forinstallationswhereothercards
orthehostsystemhaveinternalconnectionsbetweenbattery
returnandframeground,thesystemwouldbeintendedfor
deploymentonlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPOC‐12isproperlygroundedviathe
backplaneconnector.
NOTE
♦ TheOC‐12port(s)areopticalandthereforearenotclassifiedas
anytypeofportasdefinedinAppendixBofGR‐1089‐CORE
Issue5.
♦ ThisSFPOC‐12iscompliantwithSFF‐8472“Digital
DiagnosticsMonitoringInterfaceforOpticalTransceivers,”
Revision9.3.
♦ ThisSFPOC‐12iscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ ThisproductisdesignedtobedeployedinGR‐3108‐CORE
environmentclass1or2asdefinedinGR‐3108‐COREissue2.
TheSFPOC‐12isdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Thisproducthasbeenevlauatedtointernationalsafetystandards
EN60950‐1,AS/NZS60950.1,andIEC60950‐1.Thisproduct
meetstherequirementsforCEmarkingundertheEMCDirective
andLowVoltageDirective.Standardsusedtodemonstrate
ComplianceareEN300386andEN60950.
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli‐
cableexemptions.Refertowww.adtran.comforfurtherinfor‐
mationonRoHS/WEEE.