advidia A-200 User manual

A-200 Installation Manual
1
A-200 Speed Dome
Installation Manual
V1.0.2

A-200 Installation Manual
2
Thank you for purchasing our product. If there is any question or request, please do not hesitate to
contact the dealer or tech support at (713) 621-9779
This manual is applicable to A-200.
This manual may contain several technically inaccurate points or printing errors, and the content is
subject to change without notice. The updates will be added into the new version of this manual.
We will readily improve or update the products or procedures described in the manual.
DISCLAIMER STATEMENT
“Underwriters Laboratories Inc. (“UL”) has not tested the performance or reliability of the security
or signaling aspects of this product. UL has only tested for fire, shock or casualty hazards as outlined
in UL’s Standard(s) for Safety, UL60950-1. UL Certification does not cover the performance or
reliability of the security or signaling aspects of this product. UL MAKES NO REPRESENTATIONS,
WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY
OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.”

A-200 Installation Manual
3
Regulatory Information
FCC Information
FCC compliance: This equipment has been tested and found to comply with the limits for a digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with
"CE" and comply therefore with the applicable harmonized European standards
listed under the Low Voltage Directive 2006/95/EC, the EMC Directive
2004/108/EC.
2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed
of as unsorted municipal waste in the European Union. For proper recycling, return
this product to your local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated collection points. For more information see:
www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that cannot be
disposed of as unsorted municipal waste in the European Union. See the product
documentation for specific battery information. The battery is marked with this
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the battery to your supplier or to a designated collection point.
For more information see: www.recyclethis.info.

A-200 Installation Manual
4
Safety Instruction
These instructions are intended to ensure that user can use the product correctly to avoid danger or
property loss. The precaution measure is divided into Warnings and Cautions:
Warnings: Neglecting any of the warnings may cause serious injury or death.
Cautions: Neglecting any of the cautions may cause injury or equipment damage.
Warnings:
Follow these safeguards to prevent
serious injury or death.
Cautions:
Follow these precautions to
prevent potential injury or
material damage.
Warnings
All the electronic operation should be strictly compliance with the electrical safety regulations,
fire prevention regulations and other related regulations in your local region.
Please use the power adapter, which is provided by normal company. The standard of the power
adapter is 24VAC10% or 12VDC10% (depending on models). The power consumption cannot
be less than the required value.
Do not connect several devices to one power adapter as adapter overload may cause over-heat
or fire hazard.
Please make sure that the power has been disconnected before you wire, install or dismantle
the speed dome.
When the product is installed on wall or ceiling, the device shall be firmly fixed.
If smoke, odors or noise rise from the device, turn off the power at once and unplug the power
cable, and then please contact the service center.
If the product does not work properly, please contact your dealer or the nearest service center.
Never attempt to disassemble the camera yourself. (We shall not assume any responsibility for
problems caused by unauthorized repair or maintenance.)
Cautions
Do not drop the dome or subject it to physical shock, and do not expose it to high
electromagnetism radiation. Avoid the equipment installation on vibrations surface or places
subject to shock (ignorance can cause equipment damage).
Do not place the dome in extremely hot, cold, dusty or damp locations, otherwise fire or
electrical shock will occur. The operating temperature should be -30°C ~ 65°C (outdoor speed
dome) and -10°C ~ 50°C (indoor speed dome).
The dome cover for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as heater or
radiator is forbidden (ignorance can cause fire danger).

A-200 Installation Manual
5
Do not aim the camera at the sun or extra bright places. A blooming or smear may occur
otherwise (which is not a malfunction however), and affecting the endurance of sensor at the
same time.
Please use the provided glove when open up the dome cover, avoid direct contact with the
dome cover, because the acidic sweat of the fingers may erode the surface coating of the dome
cover.
Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover, do not
use alkaline detergents.
Please keep all wrappers after unpack them for future use. In case of any failure occurred,
please return the speed dome to the factory with the original wrapper. Transportation without
the original wrapper may result in damage on the speed dome and cost additional charge.

A-200 Installation Manual
6
Table of Contents
Chapter 1 Installation............................................................................................................................................ 1
1.1 Package Contents ................................................................................................................................................. 1
1.2 Installation and Cabling........................................................................................................................................ 2
1.2.1 Installing the A-200 .......................................................................................................................................... 2
1.2.2 Connecting the Cables ..................................................................................................................................... 5
1.3DIP Switch Settings............................................................................................................................................... 6
1.3.1 DIP Switches..................................................................................................................................................... 6
1.3.2 Address Settings............................................................................................................................................... 7
1.3.3 Baudrate Settings............................................................................................................................................. 9
1.3.4 Protocol Settings ............................................................................................................................................ 10
1.3.5 Communication Mode Settings...................................................................................................................... 10
1.3.6 Terminal Resistor Settings .............................................................................................................................. 11
1.4 Alarm In/Out Connections ................................................................................................................................. 11
Chapter 2 Mount Dimension................................................................................................................................12
2.1 A-200-WM Wall Mount...................................................................................................................................... 12
2.3 A-200-Corner Mount ......................................................................................................................................... 12
2.4 A-200 Pole Mount.............................................................................................................................................. 13
2.5 Pendant Mount .................................................................................................................................................. 15
Chapter 3 Mounting Applications ........................................................................................................................16
3.1 Wall Mounting Applications ............................................................................................................................... 16
3.1.1 Mounting Components .................................................................................................................................. 16
3.1.2 Wall Mounting ............................................................................................................................................... 17
3.2 Corner Mounting Applications ........................................................................................................................... 18
3.2.1 Mounting Components .................................................................................................................................. 18
3.2.2 Corner Mounting ........................................................................................................................................... 20
3.3 Pole Mounting Applications ............................................................................................................................... 21
3.3.1 Mounting Components .................................................................................................................................. 21
3.3.2 Pole Mounting................................................................................................................................................ 23
3.4 Pendant Mounting Applications......................................................................................................................... 25
3.4.1 Mounting Components .................................................................................................................................. 25
3.4.2 Pendant Mounting ......................................................................................................................................... 26
3.6.3 Ceiling Mounting................................................................................................Error! Bookmark not defined.
Appendix .....................................................................................................................................................................28
Appendix 1 Statics, Interference Lightning and Surge Protection .................................................................................. 28
Appendix 2 Waterproof .................................................................................................................................................. 32
Appendix 3 Bubble Maintenance ................................................................................................................................... 34
Appendix 4 RS485 Bus Connection................................................................................................................................. 35
Appendix 5 24VAC Wire Gauge & Transmission Distance............................................................................................... 38
Appendix 6 Table of Wire Gauge Standards ................................................................................................................... 39

A-200 Installation Manual
1
Chapter 1 Installation
1.1 Package Contents
Please make sure that the device in the package is in good condition and all the assembly parts are
included. The main package contents are shown in Figure 1-1.
Figure 1-1 Package Contents
Note: Do not lift the speed dome with its waterproof cables as shown in Figure 1-2, otherwise the
waterproof performance is affected.
Figure 1-2 Do Not Lift by the Cables
POWER
Pendant adapter
Allen key
Safety rope
Power adapter

A-200 Installation Manual
2
1.2 Installation and Cabling
1.2.1 Installing the Speed Dome
Steps:
1. Loosen the two lock screws on both sides of the speed dome. Pull the lower dome to separate it
from the back box as shown in Figure 1-3.
Note: Please do not remove the lock screws from the dome.
2. Remove the protective foam, sticker and lens cover from the dome drive.
3. Align the slots on the lower dome with the lock screws on the back box to reinstall the lower
dome. Tighten the lock screws.
Figure 1-3 Remove the Lower Dome
4. Install the dome mount. Please refer to the related sections in Chapter 2 and Chapter 3 for
specific installation methods with different mounts.
Notes:
For cement wall, you need to use the expansion screws to fix the mount. The mounting hole of
the expansion pipe on the wall should align with the mounting hole on the mount.
For wooden wall, you can just use the self-tapping screw to fix the mount.
Please make sure that the wall is strong enough to withstand more than 8 times the weight of
the dome and the mount.
5. Configure the dome address, baud rate, protocol and other parameters through DIP switch SW1
and SW2 which you can see after removing the lower dome. Please refer to Section 1.3 DIP
Switch Settings for details.
Notes:
Lock
Screw
Back Box
Lower Dome
Sticker
Protective
Foam
Lens Cover

A-200 Installation Manual
3
You do not have to set the address, baud rate, protocol and other parameters of network speed
dome through DIP switches.
The SD card slot of network speed dome is shown in Figure 1-5.
Figure 1-4 DIP Switches
Figure 1-5 SD Card Slot for Network Dome
6. Mounting the speed dome to the A-200-WM.
Steps:
(1) Apply thread tape to the thread of the pendant adapter and rotate the pendant adapter to
the mount. Secure the pendant adapter to the mount with a set screw (supplied).
(2) Loosen the lock screws of the adapter, as shown below:
SD Card Slot

A-200 Installation Manual
4
Figure 1-6 Install the Pendant Adapter
(3) Hook the back box of the speed dome to the mount with the safety cable. Route the cables
through the mount.
(4) Align the direction label of pendant adapter with the label of the back box to install the
speed dome. Rotate the back box counterclockwise or clockwise tightly. Secure the back box
and the pendant adapter with two lock screws.
Note: Please remove the protective film on the lower dome after the installation is finished.
Figure 1-7 Align the Direction Label
①
②
①
②
Lock Screw
Labels
Lock
Screw
Pendant Adapter
Loosen the
Lock Screws
Safety Cable

A-200 Installation Manual
5
Figure 1-8 Mount the Dome
1.2.2 Connecting the Cables
Before you start:
Please make sure there is no power applied to the dome before connecting the cables.
Choose the video cable according to the transmission length. The video should meet the
following minimum requirements: 75Ω resistance; 100% copper core conducting wire; 95%
copper shield.
RS485 communication cable, please refer to Appendix 2
24V AC power cable, please refer to Appendix 3
The cable connections of the A-200 speed dome are shown in the following figures. Please refer to
the following figure for connecting the RS-485, power and video cables.
As shown in the following figures, label instructs you to connect the power cables. Labels and
instruct you to connect the RS-485 cables.
Table 1-1 Connections
Name
Description
24V AC
Alternating current power supply interface
RS485+, RS485-
Interfaces for receiving commands
IN1/2/3/4/5/6/7, GND
Alarm input interfaces
OUT1/2, COM1/2
Alarm output interfaces
VIDEO
Video output interface
AUDIO-IN, GND
Audio input interface
AUDIO-OUT, GND
Audio output interface
③

A-200 Installation Manual
6
Figure 1-9 Cables of Network Speed Dome
1.3 DIP Switch Settings
1.3.1 DIP Switches
Two DIP switches SW1 and SW2 are for setting the speed dome address, baudrate, protocol, etc.,
with value ON=1 and OFF=0, as shown in Figure 1-10. Each number of the switch represents a DIP
value, ranging from 1 to 8 for the lowest to highest. Please refer to Section 1.3.2 to 1.3.6 for detailed
settings.
RED AC24V
YELLOW/GREEN
BLACK AC24V
YELLOW R485 -
ORANGE R485 +
WHITE T485 -
GREEN T485 +
VIDEO
Black 1
Yellow&Green 2
Red 3
Yellow 1
Orange 2
White 1
Green 2
Video Output
AUDIO-IN
GND
AUDIO-OUT
OUT 2
COM 2
OUT 1
COM 1
AMP-IN 1
AMP-IN 2
GND
AMP-IN 3
AMP-IN 4
AMP-IN 5
AMP-IN6
AMP-IN7
Red&White
Green&White
Blue&White
Orange
Yellow
Brown
Red
Green
Blue
Black
Purple
Gray
White
Black&White
Brown&White
Label
Label
Label
Network

A-200 Installation Manual
7
Figure 1-10 DIP Switch Settings
Notes:
The default dome address is 0; the default baud rate is 2400; and the default value of the 120Ω
terminator is OFF.
For HD-SDI speed dome, it adopts self-adaptive PELCO-D, PELCO-P and private protocol which
cannot set by the DIP switches.
For fiber speed dome, it adopts the protocol according to different vendors, with fixed fiber
baud rate as 115200bps.
1.3.2 Address Settings
The DIP switch SW1 is used for setting the address of speed dome. You can refer to Table 1-2 and
Table 1-3 for details of setting the speed dome address to a specific number.
Table 1-2 Set the Dome Address
Dome
Address
SW1 Settings
1
2
3
4
5
6
7
8
0
ON
1 2 3 4 5 6 7 8
SW1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
1 2 3 4 5 6 7 8
SW1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
-
-
-
-
-
-
-
-
-
-
255
ON
1 2 3 4 5 6 7 8
SW1
ON
ON
ON
ON
ON
ON
ON
ON

A-200 Installation Manual
8
Table 1-3 Set the Dome Address from 0 to 71
DIP Switch SW1 Settings
Address
1
2
3
4
5
6
7
8
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
10
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
12
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
13
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
14
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
15
ON
ON
ON
ON
OFF
OFF
OFF
OFF
16
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
17
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
18
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
19
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
20
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
21
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
22
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
23
ON
ON
ON
OFF
ON
OFF
OFF
OFF
24
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
25
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
26
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
27
ON
ON
OFF
ON
ON
OFF
OFF
OFF
28
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
29
ON
OFF
ON
ON
ON
OFF
OFF
OFF
30
OFF
ON
ON
ON
ON
OFF
OFF
OFF
31
ON
ON
ON
ON
ON
OFF
OFF
OFF
32
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
33
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
34
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
35
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
36
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
37
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
38
OFF
ON
ON
OFF
OFF
ON
OFF
OFF

A-200 Installation Manual
9
DIP Switch SW1 Settings
39
ON
ON
ON
OFF
OFF
ON
OFF
OFF
40
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
41
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
42
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
43
ON
ON
OFF
ON
OFF
ON
OFF
OFF
44
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
45
ON
OFF
ON
ON
OFF
ON
OFF
OFF
46
OFF
ON
ON
ON
OFF
ON
OFF
OFF
47
ON
ON
ON
ON
OFF
ON
OFF
OFF
48
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
49
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
50
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
51
ON
ON
OFF
OFF
ON
ON
OFF
OFF
52
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
53
ON
OFF
ON
OFF
ON
ON
OFF
OFF
54
OFF
ON
ON
OFF
ON
ON
OFF
OFF
55
ON
ON
ON
OFF
ON
ON
OFF
OFF
56
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
57
ON
OFF
OFF
ON
ON
ON
OFF
OFF
58
OFF
ON
OFF
ON
ON
ON
OFF
OFF
59
ON
ON
OFF
ON
ON
ON
OFF
OFF
60
OFF
OFF
ON
ON
ON
ON
OFF
OFF
61
ON
OFF
ON
ON
ON
ON
OFF
OFF
62
OFF
ON
ON
ON
ON
ON
OFF
OFF
63
ON
ON
ON
ON
ON
ON
OFF
OFF
64
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
65
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
66
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
67
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
68
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
69
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
70
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
71
ON
ON
ON
OFF
OFF
OFF
ON
OFF
1.3.3 Baud rate Settings
Positions 1, 2 and 3 of DIP switch SW2 are for setting the baud rate of the speed dome, and stand
for 2400bps, 4800bps, 9600bps, 19200bps and 38400bps respectively. The baud rate will be set as
2400bps by default if it is out of this range. Refer to the following table:

A-200 Installation Manual
10
Table 1-4 Set the Baud rate of the Dome
DIP Switch SW2-Baud Rate Settings
Baud Rate
Positions1-3
Settings
1
2
3
2400
ON
1 2 3 4 5 6 7 8
SW2
ON
OFF
OFF
4800
ON
1 2 3 4 5 6 7 8
SW2
OFF
ON
OFF
9600
ON
1 2 3 4 5 6 7 8
SW2
ON
ON
OFF
19200
ON
1 2 3 4 5 6 7 8
SW2
OFF
OFF
ON
38400
ON
1 2 3 4 5 6 7 8
SW2
ON
OFF
ON
1.3.4 Protocol Settings
Positions 4, 5 and 6 of DIP switch SW2 are for setting the communication protocols of the dome.
Refer to the following table:
Table 1-5 Set the Protocol of the Dome
DIP Switch SW2-Protocol Settings
Protocol
Positions 4-6
Settings
4
5
6
Bosch
Manchester
O
N
12345678
SW
2
OFF
ON
ON
AD Manchester
O
N
12345678
SW
2
ON
ON
ON
Self-adaptive
Others
Note: The A-200 does not support Manchester Code protocol.
1.3.5 Communication Mode Settings
Position 7 of DIP switch SW2 is for setting the RS485 communication mode of the dome to simplex
or half-duplex.
Table 1-6 Set Communication Mode of the Dome
DIP Switch SW2-Simplex/Half-duplex
Settings
Description
Position 7
Setting
7
Simplex
ON
1 2 3 4 5 6 7 8
SW2
OFF
Half-duplex
ON
1 2 3 4 5 6 78
SW2
ON

A-200 Installation Manual
11
1.3.6 Terminal Resistor Settings
Open the bubble of the dome and you will find the 120Ωterminal resistor on the side of the dome
as shown below.
Figure 1-11 Termination Resistor
In half-duplex mode, you can switch the position 2 to ON to enable the resistor;
In full-duplex mode, switch position 2 to ON to enable the resistor of the receiving end, and
switch position 1 to ON to enable the resistor of the sending end.
Note: The factory default setting for the speed dome is half-duplex.
1.4 Alarm In/Out Connections
The network speed dome can be connected with alarm inputs (0~5VDC) and alarm outputs. Refer to
the following diagrams for alarm output:
JQC-3FG
Relay
30VDC
GND OUT
L N
~220V AC
Relay Output
Dome
(10 A 250VAC)
Diagram (left) Diagram(right)
1A
OUT(n)
OUT(n)
+
-
DC
DC Load
Relay Output
Dome OUT(n)
OUT(n)
Figure 1-12 Alarm Out Connections
The alarm provides the relay output (no voltage), and the external power supply is required when it
connects to the alarm device.
For DC power supply (left diagram), the input voltage must be no more than 30VDC, 1A.
For AC power supply, the external relay must be used (right diagram) to prevent damages to the
speed dome and avoid risk of electric shock.
ON
2
1
ON
2
1

A-200 Installation Manual
12
Chapter 2 Mount Dimension
2.1 A-200-WM
Figure 2-1 Long-arm Wall Mount
2.2 A-200-CornerMount
Please use the wall mount with corner adapter according to your requirements.

A-200 Installation Manual
13
Figure 2-2 Corner Mount
2.3 A-200-PoleMount
Please use the wall mount with pole adapter according to your needs.

A-200 Installation Manual
14
Figure 2-3 Pole Mount
Other manuals for A-200
2
Table of contents
Other advidia Security Camera manuals

advidia
advidia A-44 User manual

advidia
advidia A-18 User manual

advidia
advidia M-26-FW User manual

advidia
advidia A-28-F User manual

advidia
advidia A-45 User manual

advidia
advidia A-28-Z User manual

advidia
advidia A-15 User manual

advidia
advidia B-210 User manual

advidia
advidia M-45-FW-V2 User manual

advidia
advidia P-24 User manual

advidia
advidia M-49-FW User manual

advidia
advidia P-240 User manual

advidia
advidia "A" Series User manual

advidia
advidia M-44-V-T-V2 User manual

advidia
advidia A64 User manual

advidia
advidia "A" Series User manual

advidia
advidia M-49-FW User manual

advidia
advidia M-46-FW-V2 User manual

advidia
advidia A-17 User manual

advidia
advidia M-46-FW User manual