Installation
Key Parts Identification .............................................................................. 3
Box Contains / Unpack ............................................................................. 4
Install & Assemble Processor ...................................................................... 4-5
Operation
Operator Controls .................................................................................... 5
Processing film.......................................................................................... 6-7
Maintenance
Daily ........................................................................................................ 8
Every Two Weeks....................................................................................... 8-9
Quarterly.................................................................................................. 10
Trouble Shooting ...................................................................................... 11-14
Specifications / Dimensions .................................................................... 14
Accessories................................................................................................. 15
Thank You and Congratulations on your purchase of the Peri-Pro III Intra-oral
Film Processor, manufactured and sold by Air Techniques, Inc. Using a proven roller-less
transport system, this unique processor carefully guides up to eight films at once through
the developing process without the image surface being touched. Automatically, in just
five-minutes, eight films are processed, dried with heated air, and deposited into the film
receptacle dry-to-dry and ready to read making it the choice of the dental profession.
The Peri-Pro III uses a heating pad system to maintain uniform chemistry bath temperature
ensuring the delivery of consistent film quality. Additional features include:
qNo plumbing connection required
qSlim space saving design makes it ideal for small office spaces.
qEasy operation - load eight films for processing in less than one minute
qAutomatically processes up to eight films at once in only 5 minutes
qConvenient access door facilitates easy wash water refill
qOptional Daylight Loader or Daylight/Loader Film Duplicator eliminates
the need for a dark room
Each Peri-Pro III system has been designed and manufactured to produce the most rugged
and dependable film processing system available for the continual demands of the modern
dental office. Review and follow the guidelines included in this manual to ensure that your
Peri-Pro III gives the highest level of service. By following the Maintenance procedures
detailed in this manual, you can depend on years of reliable service from your Peri-Pro III
film processor.

3
Figure 1. Exterior View
Figure 2. Interior View
FILM TRANSPORT
DRYER TRANSPORT
DEVELOPER
TANK
(BLACK)
PCB & TRANSFORMER
COVER
5 AMP FUSE
AIR HOLES
THERMISTOR
ARM
DRYER HEATING
ELEMENT
ACCESS PANEL
WASH TANK
(WHITE)
FIXER TANK
(RED)
FILM INLET GRILL
FILM INLET
SHUTTER COVER
ASSEMBLY
MAINTENANCE
LABEL
OPERATOR
CONTROLS
FILM DELIVERY
RECEPTACLE
AIR OUTLET GRILL
AIR INLET GRILL
TRASH
RECEPTACLE
TABS FOR
CARRIERS FILM PACKET
STORAGE
REFILL ACCESS
PANEL
Not shown: Grill inlet cover -
comes installed on the Film Inlet Grill
KEY PARTS IDENTIFICATION

4
INSTALLATION
Shipping Box Contents:
Peri-Pro III Processor base with cover -
Note: Grill Inlet Cover comes installed on
the Film Inlet Grill
Inside the processor:
Film transport
Chemistry tanks (Black developer tank;
red fixer tank; white water tank)
Accessory boxes (3) containing:
# 90850 -
3 ea. Pedo (#0) Film Carrier
2 ea. Bite-wing Film (#3) Carrier
# 90825 -
3 ea. Anterior Film (#1) Carrier
1 ea. Occlusal Film (#4) Carrier
# 90840 -
Film receptacle with 3 dividers
Unpack:
1. Place one hand on each side and under-
neath the processor. Lift the processor out of
the carton and place it on a flat surface.
Remove the end caps and plastic bag.
2. Remove the processor cover and set aside.
3. Remove the accessory boxes and retain for
future use. Remove the top packing foam.
4. Pull the cardboard insert out of the dryer rack
and set aside; lift the transport out (the trans-
port cannot be removed until the cardboard
insert is removed first).
5. Remove the shipping foam from the back
wall of the processor.
6. Remove the foam cleaning pads from the
chemistry tanks and set aside.
7. Do not remove the clips holding the water
drain tube to the perimeter of the base.
8. Set the base on a flat, level, stable counter.
Important: The surface must be stable so that
chemistry does not splash or spill.
Locate the thermistor arm above and to the left of the developer
(black) tank. Carefully lift the arm up, using the finger hole, until it
locks in place. See Figure 3.
Note: Empty entire contents into the water tank.
Remove all three tanks and rinse.
Install the fixer tank next to the water tank, and fill with contents of
the fixer bottle. Pour carefully to prevent splashing.
Install the developer tank on the left. Fill with the contents of the
developer bottle. Lower the thermistor arm into the tank.
If chemistry or water is accidentally spilled beneath the chemistry
tanks, remove the tanks and immediately dry the tanks, both sides
of the heater plate and the depression in the base and the area
around the heater pad. Reverse the procedure to remove.
The tanks can be installed in or removed from the base only when the film transport is out
of the processor. If you installed the transport after unpacking, remove it now.
Follow the tank installation and chemistry filling sequence below to prevent contamination
of chemistry due to accidental spilling or splashing. Fixer in the developer tank will cause
contamination.
Important: Peri-Pro chemistry should be at or below 75°F.
Install Processor
1. Fill Tanks
Figure 3.

5
Figure 4
Figure 5
INSTALLATION
OPERATION
2. Assemble Processor
Lower the film transport straight into the tanks.
The film transport must sit squarely on the cut-
outs found on the top of the vertical plates to
the left and right side of the tanks.
Note: The Transport locks the thermistor into place.
Install the film inlet grill on top of the film trans-
port. Note that it installs one way: track 1 to the
rear and track 8 to the front of the processor.
Install the processor cover onto the base with the refill access door in front.
Snap the film dividers (optional installation) into place in the film delivery receptacle. Hang
the film delivery receptacle on the cutout at the dryer end of the cover.
Plug the line cord into a 115V outlet.
3. Check Operation of Refill Access Door
Open the refill access door by firmly pinching
the two tabs, then pulling the door open. There
will be some resistance.
Close the panel by pushing it in until it latches
(snaps) shut.
Figure 7
Figure 6
AB
POWER READY WHEN LIT
PROCESS
Operating Controls
POWER SWITCH (Amber)
When the POWER switch is turned
ON it will illuminate, indicating
that there is power to the proces-
sor and the heating system is on.
Turn the POWER switch OFF at
the end of the day. See Figure
6A.
TEMPERATURE READY LIGHT
(Green)/PROCESS SWITCH.
When chemistry reaches its fac-
tory pre-set processing tempera-
ture of 75°F, the READY light
flashes, then remains steady,
indicating that chemistry is at
processing temperature.
Processing is initiated by turning
the PROCESS switch ON.
After processing, the PROCESS
switch is turned OFF. The Peri-
Pro remains ready to process film
as long as the POWER switch is
left in the ON position and the
green READY light is illuminated.
See Figure 6B
REFILL ACCESS DOOR
This door must be closed when
processing film. It is closed when it
latches, or snaps, shut. See Figures
1 and 5.
FILM INLET SHUTTER
When the shutter is slid to the right,
it latches in place. Films drop into
the transport and begin processing
automatically when the transport
arms move into position and the
shutter opens. New batches of film
can be processed every 55 seconds.
REFILL ACCESS DOOR
Open the refill access door when
changing and refilling water, and
to check chemistry levels at the
start of the day.

6
OPERATION
1. Before processing film, open the refill access door to determine whether chemistry in the
developer and fixer tanks are at the Fill Line level as indicated on the inside of the refill
access door. If not, top with water to the Fill Line. Close the refill access door.
2. Turn the POWER switch ON. The amber light illuminates, indicating that there is power to the
processor, the heating system is on and the chemistry is being heated. Chemistry heats at a rate
of about 1°F every two to three minutes. For example: chemistry initially at 65°F will reach set
point (75°F) in about 25 minutes.
3. When the chemistry is within 1°F of the pre-set processing temperature, the TEMPERATURE
READY/PROCESS light flickers. When the light remains steady, the factory pre-set temperature
has been reached and the Peri-Pro III is ready to process film. Only process film when the
TEMPERATURE READY/PROCESS light is on.
4. Turn the PROCESS switch ON. (There is no visual indication, only an audible motor sound and
warm air blowing out of the air outlet grill when processor is in the PROCESS mode.) Insert
film into the film inlet and slide the shutter to the right until it latches. Film is automatically
processed. A new batch of film can be processed every 55 seconds.
Use the handy removable trash receptacle when stripping covers off lm.
The trash receptacle is especially useful when using a Daylight Loader.
Processing #2 (Adult) Films.
#2 films can be fed directly into the processor
Duplicating lms exposed in the Peri-Pro Film Duplicator/Daylight Loader are
processed in the same manner as regular lms.
Processing Film
Note: I a lm is bent, straighten it.
c. As soon as the shutter moves back into the original closed position, the next batch of films
may be loaded into the inlet slots and the process repeated.
d. When the last films to be processed are loaded, place the inlet cover over the film inlet. The
inlet cover prevents film fogging due to light leaks. If a Daylight Loader is being used, put the
inlet cover in place before hands are removed from the cuffs.
Note: The inlet cover comes installed on the grill inlet.
e. When films have completed the processing cycle, they are delivered into the film delivery
receptacle.
a. Strip the cover off a periapical film and place it into any of the
eight slots of the inlet grill. All 8 slots can be loaded at the same
time if required. Do not put two films into the same slot.
b. Slide the shutter to the right until it latches. The films drop into
the transport and begin processing when the transport arms
automatically move into position and the shutter opens.
Figure 9
Note: With dividers in place in the lm receptacle, the four compartments
correspond to slots I & 2, 3 & 4, 5 & 6, 7 & 8 of the lm inlet grill.
The dividers separate sets of lm pairs.

7
OPERATION
b. Insert the carrier into slots 3 and 6 in the film
inlet. Make sure the edges of the film(s) clear
the side walls of the film inlet.
c. Slide the shutter to the right until it latches. The
carrier will drop into the transport and processing
begins when the shutter automatically opens.
Processing #4 (Occlusal) Films
a. Strip the cover off one #4 film and carefully
bend almost in half. Slide the film into the carrier,
making sure both edges of the film are held in
place by the guide tabs. Remove film inlet grill.
#0 and #1 films cannot be fed directly into the processor. These films fit into
corresponding # carriers (supplied with the processor), each of which carries the
film through the processing cycle. Up to six #0 or #1 films can be loaded into
corresponding carriers at one time.
Processing #0 (Pedo) or #1 (Adult Anterior) Films.
Figure 10
Figure 11
#0
#1
#3
#4
a. To load #0 or #1 film into the corresponding # carrier,
nest the carrier inside the tabs on the cover, next to the
inlet grill.
b. Strip the cover off the film(s) and slide the film(s) vertically,
one at a time, into any of the six grooves on the carrier.
Push down firmly until the film touches the cover. Repeat
until as many grooves as required are filled. The films
should be standing vertically and parallel to each other,
away from the center bar. Make sure that each film on the
carrier is in its own groove.
c. Remove the film inlet grill. (Remember to replace it when processing #2 films.) Insert the
carrier, with the film(s) standing vertically, into the film inlet.
d. Slide the shutter to the right until it latches. The carrier will drop into the transport and
begin processing when the shutter automatically opens.
Processing #3 (Bite-Wing) Films
#3 lms cannot be fed directly into the processor. Use a #3 carrier that holds two
lms at a time.
a. Strip the cover off one or two #3 film(s) and slide the film(s) horizontally, one at a time,
through both side plates of the #3 carrier. Remove film inlet grill.
b. Place the carrier onto the film inlet with the orientation arrow (on the side of the carrier)
pointing down.
c. Slide the shutter to the right until it latches. The carrier will drop into the transport and
begin processing when the shutter automatically opens.
5. When processing is completed, turn the PROCESS switch OFF. The green READY light remains
lit. At the end of the day turn the POWER switch OFF. Both the green READY light and the
amber POWER light will extinguish.
To assure complete drying of processed # 4 films, a
manual assist may be needed,if so;
1. While the fan is blowing, hold the open end of the film
in the carrier directly over the dryer grille, about 1”- 2”
elevation is sufficient, and slowly pivot the carrier to
have warm air blow on the outer surface.
2. 30-60 seconds should be enough time to adequately
dry film.
3. Unload the dried film from the carrier when done.

8
MAINTENANCE
Servicing your Peri-Pro III on a daily, two week and quarterly basis is critical to maintaining quality
processor performance. We recommend the maintenance procedure outlined below, using Formula
2000 Plus cleaner, and Peri-Pro Developer and Fixer, which are specially formulated for Peri-Pro pro-
cessors. This maintenance schedule may have to be modified if more frequent cleaning is required.
DAILY - CHANGE WATER
TOP OFF CHEMISTRY TANKS WITH WATER TO FILL LINE
Important:
Make sure not to mix the developer and xer chemistry.
Contaminating the solution will degrade image quality.
Dispose of wash water in accordance with local codes.
EVERY TWO WEEKS (or every 300 - 350 lms)
SCRUB TRANSPORT; CHANGE PERI-PRO CHEMISTRY
Caution: Cleaning and changing chemistry requires the
removal of the cover and lm transport from
the Peri-Pro III. Always turn POWER off and
unplug the line cord before removing the cover
or transport.
Scrub Transport
1. Turn POWER OFF and unplug the line cord. Remove the film receptacle, lift off the cover.
2 Lift the film transport and let the solutions drip back into the tanks before placing the transport
in a sink. (Use of optional Service Tray PN 90121 will contain any dripping chemistry.)
3. Rinse the transport thoroughly with warm water to soften residue and dried chemistry. Be sure
to rinse above the chemistry level, keeping the shutter and the film inlet on the top of the
transport dry. (Use a sink or the transport wash tub that comes with the Transport Cleaning
Kit PN 43975.)
1. Turn POWER OFF and unplug the power cord from the outlet.
2. Remove the film delivery receptacle (see figure 1) at the film dryer exit on the right side of the
cover. Remove the main cover by carefully lifting away from the unit.
Important: Do not splash chemistry or contamination may result.
3. As shown by Figure 4, carefully lift the Film Transport and hold over the tanks for a few seconds
so liquids drain back into tanks and place the transport on the service tray P/N 90121.
4. Remove the water tank (white), discard the water and rinse out the tank. If the wash tank is
particularly soiled or slimy, it must be thoroughly cleaned and rinsed.
5. Refill the clean water tank with 70° 80°F water; reinsert into base.
6. Check that the solution in the developer (black) and fixer (red) tanks are up to the Fill Lines as indi-
cated on the inside of the refill access door. If not, top off the developer and fixer tanks with water.
7. Slowly and carefully lower the Film Transport straight into the tanks. The Film Transport must
sit squarely on the cutouts found on the top of the vertical plates to the left and right side of
the tanks.
8. Align the Main cover and carefully install the Main Cover onto the unit.
9. Hang the film delivery receptacle (see figure 1) on the film dryer exit on the right side of the cover.
10. Plug the power cord into the electrical outlet and turn the POWER ON.

9
MAINTENANCE
If the wash tank is particularly soiled or slimy, it must be thoroughly cleaned and rinsed.
To do this, first remove the film transport.
If the tank was removed, clean and dry the tank drain stem receptacle in the base.
Clean and drain the drip pan.
After cleaning, reinstall the wash tank.
2. Carefully lift the thermistor arm up until it locks in place (and remove the transport if it is still
installed). Remove the developer and fixer tanks and dispose of the old chemistry in accordance
with local codes. Clean the thermistor.
3. Rinse and, using separate color-coded sponges to avoid possible contamination, clean both
tanks. Rinse again and wipe dry with a lint-free towel.
4. Reinstall the fixer (red) tank in the base. Fill with contents of the Peri-Pro fixer bottle. Pour care-
fully to prevent splashing.
5. Reinstall the developer (black) tank in the base. Fill with contents of the Peri-Pro developer
bottle. Pour carefully to prevent splashing and possible contamination. Lower the thermistor
arm into place in the developer tank.
Note: Peri- Pro chemistry should be at or below 75°F.
Reassemble the Peri-Pro III
1. Slowly and carefully lower the film transport straight into the tanks. The film transport must sit
squarely on the cutouts found on the top of the vertical plates to the left and right side of the tanks.
2. Insert the film inlet grill on top of the transport.
3. Install the cover with the refill access door in front. Hang the film delivery receptacle on the cutout
at the dryer end of the cover.
4. Plug the line cord into a 115V outlet and turn the POWER switch ON.
Figure 12
4. Scrub grooves inside the transport with a small brush,
paying close attention to the areas just above the
chemistry line, where crystallization occurs. Rinse to
remove deposits. See Figure 12.
5. Scrub and rinse the gears on the back of the transport.
6. With a dry, lint-free cloth wipe off any moisture from
the shutter and the film inlet area and grill. Impor-
tant: These areas must be dry before processing film.
7. Clean the dryer transport rollers if dry, white chemistry
residue is evident. Follow the procedure detailed
under Quarterly Maintenance #12.
CHANGE PERI-PRO CHEMISTRY
Change Developer and Fixer every two weeks or
every 300 - 350 lms, whichever comes rst.
Caution: Never operate the Peri-Pro III without
liquid in the tanks.
1. Change the water. Follow the steps for changing water
under Daily Maintenance.

10
MAINTENANCE
QUARTERLY - CLEAN WITH FORMULA 2000 Plus
Clean the Peri-Pro III Transport with Formula 2000 Plus quarterly or
whenever a black residue is evident on the transport or in the tanks.
Use the Peri-Pro Transport Cleaning Kit (PN 43975)
Each kit contains:
Cleaning
tub
Brush and cleaning sponges Twin pack of Formula 2000
Plus
CAUTION: Use cold water only.
6. Sprinkle two powder packets of Component 2 evenly across the cleaning tub. Formula 2000
Plus’s effervescent cleaning action will begin as soon as Component 2 is added. Some odor
and vapor will be evident.
7. Soak the transport for approximately 30 minutes, or until the effervescent action stops.
8. Remove the transport and, under cold running water, remove any remaining deposits with the
brush; rinse.
9. Dispose of the cleaning solution in accordance with local codes. Rinse the cleaning tub and
place the transport back in the tub. Fill with fresh water and drain. Rinse and drain at least 2
more times. (Be sure to rinse thoroughly since cleaner residue can contaminate fresh chemistry.)
10. Place the transport on a towel with the gears facing up and air dry thoroughly. Check that the
shutter area is dry before using. If not, dry with a soft, lint-free towel. See Fig. 14.
11. Change the water. Follow the steps for changing water under Daily Maintenance. If the wash
tank is particularly soiled or slimy, it must be thoroughly cleaned and rinsed. After cleaning, if
the tank was removed.
Figure 13
Figure 14
CAUTION: Use in a well ventilated area. Wear protective clothing, rubber
gloves and goggles. Review the Material Safety Data Sheet
that comes with every Formula 2000 Plus Twin Pack.
1. Turn the POWER OFF and unplug the line cord. Remove the
film receptacle; lift the cover off.
2. Remove the transport and rinse under running water.
3. Place the transport into the cleaning tub with the gears facing
up .
4. Pour two bottles of Formula 2000 Plus Component 1 into the
cleaning tub. Pour slowly. Do not splash or splatter solution -
wipe up any spills. (Use both bottles of Formula 2000 Plus in
the Twin Pack to insure adequate cleaning of the transport.)
5. Add cold water to the recessed line in the tub.
12. Clean the Dryer Transport if dry, white chemistry residue is evident on
the rollers.
Remove the screw holding the dryer front cover plate in place.
Slide the cover plate up, remove it and lift the dryer transport
straight up and out.
Use warm water and a brush to remove the residue; rinse and
completely air dry.
Reinstall the dryer transport and the cover plate.
Important: This plate is necessary for proper lm drying.
13. Change the chemistry. Follow the steps for changing chemistry under Every Two Weeks
Maintenance.
14. Reinstall the transport and reassemble the Peri-Pro III. Follow the steps for reassembly under
Every Two Weeks Maintenance.

11
TROUBLESHOOTING
Problem Possible Cause Possible Solutions
1. Film too light. a. Developer exhausted. a. Change chemistry after 300-350 film
or 2 weeks, whichever comes first.
b. Chemistry does not reach factory
set temperature.
b. Call you authorized Air Techniques
dealer for service.
c. X-ray machine is improperly set
or inconsistent.
c. Call your x-ray dealer for service
d. Developer is contaminated d. Dispose of chemistry and clean
with Formula 2000 Plus.
Replace chemistry and water.
e. Improper or outdated film. e. Check date on film box
f. Not using specially formulated
Peri-Pro chemistry.
f. Use Peri-Pro chemistry to assure
film quality and archival quality
2. Film too dark or
grainy too high
a. Developer temperature is a. Call you authorized Air Techniques
dealer for service.
b. X-ray machine is improperly set
or inconsistent.
b. Call your x-ray dealer for service
c. Film has been exposed to light c. Check for and correct light leaks in
the dark room or daylight loader.
Place the inlet cover on the film
inlet before leaving the darkroom
or before removing hands from the
daylight loader cuffs.
d. Not using specially formulated
Peri-Pro chemistry.
d. Use Peri-Pro chemistry to assure
film quality and archival quality
3. Film is cloudy or has
brownish surface.
a. Fixer is exhausted. a. Change chemistry after 300-350 film
or 2 weeks, whichever comes first.
b. Fixer temperature is too low. b. Wait until the ready light stays on
continuously, indicating that the
set-point has been reached.
c. Chemistry does not reach factory
set temperature.
c. Call you authorized Air Techniques
dealer for service.
d. Improper or outdated film. d. Check date on film box. Make sure
that the film being used is recom-
mended for automatic processing.
4. Film is not dry. a. Improper or outdated film. a. Check date on film box. Make sure
that the film being used is recom-
mended for automatic processing.
b. Depleted chemistry. b. Change chemistry after 300-350 film
or 2 weeks, whichever comes first.
c. Contaminated chemistry. c. Dispose of chemistry, clean with
Formula 2000 Plus. Replace
chemistry and water.
d. Not using specially formulated
Peri-Pro chemistry.
d. Use Peri-Pro chemistry to assure
film quality and archival quality.
e. Defective dryer heater, fan mo-
tor or thermal fuse. (If air is not
hot, heater or fuse is defective.)
e. Call your authorized Air Techniques
dealer for service.
f. Dryer air shroud or baffles are
not in place.
f. Call your authorized Air Techniques
dealer for service.

12
Problem Possible Cause Possible Solutions
5. Film has black edge at
one end.
a. Light fog. a. Check for and correct light leaks
in the dark room or daylight load-
er. Put the grill inlet cover on the
film inlet before leaving the dark-
room or before removing hands
from the daylight loader cuffs.
b. Safe light defective or too close.
Light should be a minimum of 4
feet away from the work area.
6. Film has a diagonal or
curved line through it.
a. Chemistry level is low. The en-
tire film is not being covered
by chemistry bath as it travels
down into the chemistry tanks.
a. Make sure chemistry is at the Fill
Line. If not, top off tank to the Fill
Line with water.
b. Chemistry deposits and crystalli-
zation are clogging the grooves
in the transport, preventing the
films from fully dropping into
the chemistry bath.
b. Clean grooves with a soft tooth-
brush.
c. Timing of the transport arms is
out of adjustment.
c. Call your authorized Air Tech-
niques dealer for service.
7. Developer is black, has
ammonia smell, there
are black deposits on the
bottom of the tank, black
streaks or smudges on
film, poor film density,
poor film clarity.
a. Contaminated developer. a. Tanks and transport must be
cleaned with Formula 2000 Plus.
Change chemistry.
8. Images or shadows of
other films appear n the
developed film. Light is
striking films that were
stripped and stacked on
each other before being
loaded into the film inlet.
a. Safe light in the darkroom is
defective or less than 4 feet
from film inlet.
a. Correct as required.
b. Light is leaking into the dark room. b. Correct as required.
Unit with Daylight Loader:
c. 1. Too much light is passing
through the view glass.
c.1. View glass test: Cover the view
glass, then process film.
c. 2. Light may be leaking around
the daylight loader cuffs.
c.2. Loader cuffs: Inspect for worn or
damaged cuffs, replace.
TROUBLESHOOTING

13
TROUBLESHOOTING
Problem Possible Cause Possible Solutions
9. Film not exiting. a. Chemistry deposits in transport
grooves cause film to pop out.
a. Clean grooves with a soft tooth-
brush.
b. Severely bent or jagged film. b. Straighten film before loading.
Insert with rough or burred end
facing up.
c. Film has jagged edge (burr) in
solution
c. Proper cleaning of grooves over-
comes this. Use film without jag-
ged edge.
d. Films fed incorrectly. d. Make sure transport is seated
squarely. Put only one film into a
track. Use film inlet grill for #2
film.
When using a film carrier, load the
carrier so that the film does not hit
the side of the inlet.
e. Transport arms are out of align-
ment. Films will be lost constant-
ly, not occasionally.
e. Call your authorized Air Techniques
dealer for service.
f. Defective drive motor. f. Call your authorized Air Techniques
dealer for service.
g. Films reach dryer and staythere
- broken gear teeth or defective
gears or install missing ones.
g. Call your authorized Air Techniques
dealer for service to replace missing
gear in gear train.
10. Shutter does not
catch, sticks or is
hard to move.
a. Broken spring, worn release bar,
defective shutter, shutter is off
tracks, or shutter is contaminated
with chemistry.
a. Call your authorized Air Techniques
dealer for service.
11. Processor doesn’t
operate.
a. Line cord is not plugged in. a. Plug in line cord.
b. Defective interior fuse or switch. b. Call your authorized Air Techniques
dealer for service.
12. Chemistry does not
heat or chemistry gets
too hot. Otherwise,
the Peri-Pro is func-
tioning.
a. Defective thermistor, defective PC
board or defective heater pad,
etc.
a. Call your authorized Air Techniques
dealer for service.

14
TANK CAPACITIES Developer and Fixer Tanks - 32 oz. each
Water Tank - 40 oz.
ELECTRICAL REQUIREMENTS 115 Volts, 5 Amps
WEIGHT 28 lbs. ( kg)
10 1/2"
25"
3 1/2"
8 1/2"
25"
10 ½"
3½"
15 ½"
8½"
Length Width Height
Overall 25” 9 3/4” 8 1/2”
With Daylight Loader 25” 9 3/4” 15 3/4”
With Film Duplicator/Daylight Loader 25” 12 3/4” 15 3/4”
Add 3 1/2” to length for film receptacle
MINIMUM CLEARANCE TO REMOVE COVER:
Without Daylight Loader - 14 1/2”
With Daylight Loader or Film Duplicator/Daylight Loader - 21 3/4”
DIMENSIONS/SPECIFICATIONS
DIMENSIONS:
SPECIFICATIONS:

15
Description Part Number
Peri-Pro Transport Cleaning Kit
This kit contains all items needed to
chemically clean a Peri-Pro
Transport:
1 - cleaning tub
1 - brush
1 - twin pack of Formula 2000 Plus
43975
Refill for Transport Cleaning Kit
Formula 2000 Plus Twin Pack
Contains 2 bottles of Formula 2000 Plus
2 color-coded sponges
43945
Peri-Pro Chemistry
Case contains:
3 one qt. bottles Developer
3 one qt. bottles Fixer
90800
Film Carriers
Pedo (#0) - Box of 5
Adult Anterior (#1) - Box of 5
Bite-Wing (#3) - Box of 5
Occlusal (#4) - Box of 3
90980
90985
90990
90831
Film Duplicator / Daylight Loader
92000
Daylight Loader
90090
Service Tray 90121
ACCESSORIES/OPTIONS

Peri-Pro is a registered trademark of Air Techniques Peri-Pro III patent No. 5678117
©Air Techniques, Inc. 2004 •PN 94821, Rev. P •December 2017
qDigital Imaging
• Digital Radiography
• Intraoral Camera
• Caries Detection Aid
• Intraoral X-ray
• Film Processors
qUtility Room
• Dry Vacuums
• Wet Vacuums
• Air Compressors
• Amalgam Separator
• Utility Accessories
• Utility Packages
qMerchandise
• Evacuation System Cleaner
• Imaging Accessories
• Chemistry
• Processor Accessories
For over 50 years, Air Techniques has been a leading innovator and manufacturer of dental
products. Our priority is ensuring complete satisfaction by manufacturing reliable products
and providing excellent customer and technical support. Whether the need is digital imaging,
utility room equipment or merchandise, Air Techniques can provide the solution via our network
of authorized professional dealers. Proudly designed, tested and manufactured in the U.S., our
products are helping dental professionals take their practices to the next level.
Air Techniques’ family of quality products for the dental professional include:
Corporate Headquarters
1295 Walt Whitman Road |Melville, New York 11747- 3062
Phone: 800-247-8324 |Fax: 888-247-8481
www.airtechniques.com
Other manuals for PERI-PRO III
1
Table of contents
Other Air Techniques Medical Equipment manuals

Air Techniques
Air Techniques Mojave Mobile User manual

Air Techniques
Air Techniques AirStar AS10 User manual

Air Techniques
Air Techniques ScanX Classic User manual

Air Techniques
Air Techniques MOJAVE LT3 Manual

Air Techniques
Air Techniques MOJAVE LT3M Operating manual

Air Techniques
Air Techniques Rxonly ProVecta 3D Prime User manual

Air Techniques
Air Techniques F3700T User manual

Air Techniques
Air Techniques ProVecta 3D Prime User manual

Air Techniques
Air Techniques AirStar AS10 User manual

Air Techniques
Air Techniques CamX Elara User manual