Airspan AirHarmony-4000 User manual

AirHarmony-4000 Installation Guide
External Filters
Part Number: UGD-D01019
System Release: 14.5
Revision: 1.0
Published: January 2016

© Copyright by Airspan Networks Inc., 2016. All rights reserved worldwide.
Legal Notices
The information contained within this document is proprietary and is subject to all relevant copyright, patent and other laws
protecting intellectual property, as well as any specific agreements protecting Airspan Networks Inc. rights in the aforesaid
information. Neither this document nor the information contained herein may be published, reproduced or disclosed to third
parties, in whole or in part, without the express, prior, written permission of Airspan Networks Inc. In addition, any use of this
document or the information contained herein for the purposes other than those for which it is disclosed is strictly forbidden.
Airspan Networks Inc. reserves the right, without prior notice or liability, to make changes in equipment design or specifications.
Information supplied by Airspan Networks Inc. is believed to be accurate and reliable. However, no responsibility is assumed by
Airspan Networks Inc. for the use thereof nor for the rights of third parties which may be effected in any way by the use of
thereof.
Any representation(s) in this document concerning performance of Airspan Networks Inc. product(s) are for informational
purposes only and are not warranties of future performance, either expressed or implied. Airspan Networks Inc. standard
limited warranty, stated in its sales contract or order confirmation form, is the only warranty offered by Airspan Networks Inc. in
relation thereto.
This document may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in relation
thereto unless specifically undertaken in Airspan Networks Inc. sales contract or order confirmation. Information contained
herein is periodically updated and changes will be incorporated into subsequent editions. If you have encountered an error,
please notify Airspan Networks Inc. All specifications are subject to change without prior notice.
Product performance figures quoted within this document are indicative and for information purposes only.
Acknowledgements
© Intel Corporation http://www.intel.com/
© Microsoft Corporation http://www.microsoft.com

UGD-D01019 Airspan Commercial and Internal Use i
Table of Contents
Document Information ......................................................................................1
Abstract .................................................................................................................................1
Revision History.....................................................................................................................1
Warnings and Cautions ......................................................................................2
Human Exposure to Radio Frequencies ................................................................................2
Radio Interference ................................................................................................................2
Modifications ........................................................................................................................2
General..................................................................................................................................2
Safety.....................................................................................................................................3
Warning of Hazardous Voltages............................................................................................3
Adherence to European Directive 1999/519/EC ..................................................................3
Warning Symbols ..................................................................................................................4
Service Information...............................................................................................................4
UL Information ......................................................................................................................4
Lightning Protection..............................................................................................................4
DECLARATION OF CONFORMITY ...........................................................................................5
GPS Compliance ....................................................................................................................6
Maximum Output TX Power ..............................................................................7
Power Consumption..............................................................................................................7
Antenna System ....................................................................................................................8
Long Switched Beam Antenna ..............................................................................................8
External Antenna...................................................................................................................8
About This Document ........................................................................................9
Purpose .................................................................................................................................9
Intended Audience................................................................................................................9
Document Conventions.........................................................................................................9
Document Organization ......................................................................................................10
Related Reading ..................................................................................................................10

AirHarmony-4000 (External Cavity Filter) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use ii
Customer Care Help Desk ................................................................................11
Airspan Encourages Comments ..........................................................................................11
1Introduction.................................................................................................12
1.1 AirHarmony-4000 ........................................................................................................12
1.2 Deployment .................................................................................................................12
2Getting Started ............................................................................................14
2.1 Workflow of Installation ..............................................................................................14
2.2 AirHarmony-4000 Installation Checklist......................................................................15
3Verifying Prerequisites.................................................................................15
3.1 Verifying Site Requirements ........................................................................................15
3.2 Verify Installation Requirements.................................................................................15
3.2.1 Verify the Tools ........................................................................................................... 15
3.2.2 Verify the Parts and Kits..............................................................................................16
3.2.3 Power Supply and Current ..........................................................................................18
3.2.4 Panels ..........................................................................................................................19
3.2.5 Physical Dimensions ....................................................................................................20
3.2.6 Environmental.............................................................................................................21
4Installing AirHarmony-4000 .........................................................................22
4.1 External Filter Assembly ..............................................................................................22
4.2 Connecting the GPS Antenna ......................................................................................28
4.3 Pole/Wall Mount Assembly .........................................................................................29
4.3.1 Mounting on a Wooden Pole ......................................................................................29
4.3.2 Mounting on a Non-Wooden Pole ..............................................................................31
4.3.3 Mounting on a Wall.....................................................................................................32
4.4 Securing AirHarmony-4000 to the Mounting Plate.....................................................34
5AirHarmony-4000 Connections ....................................................................38
5.1 Grounding ....................................................................................................................38
5.2 Remote Antenna Assembly .........................................................................................38
5.2.1 Connecting RF Jumper Cables to External Antenna....................................................38

AirHarmony-4000 (External Cavity Filter) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use iii
5.2.2 Weather-proofing the Antenna Connections ............................................................. 39
5.3 Cable Connections .......................................................................................................39
5.3.1 Copper Ethernet Cable Assembly................................................................................39
Hardware Requirements ........................................................................................................39
Assembly Instructions.............................................................................................................40
5.4 Fiber Ethernet (SFP) Cable Installation........................................................................41
5.4.1 SFP Cable Connection..................................................................................................41
5.5 Connecting the AC Power Cable to AirHarmony-4000................................................43
5.5.1 Power Cable Preparation ............................................................................................43
6Additional Installations ................................................................................47
6.1 Changing or Replacing the External Filters Set............................................................47
6.1.1 Removal of Existing External Filters Set ......................................................................47
6.1.2 Replacing the Cavity Filters .........................................................................................48
AJob Sheet .....................................................................................................51
BAbbreviations...............................................................................................52
Figures
Figure 1: AirHarmony-4000 with external cavity filters & cover ............................................................ 8
Figure 2: AirHarmony-4000 with External Filters & cover....................................................................13
Figure 3: Workflow................................................................................................................................14
Figure 4: AirHarmony-4000 Unit, Bottom panel...................................................................................19
Figure 5: AirHarmony-4000 Unit, Top panel.........................................................................................20
Figure 6: AIrHarmony-4000 with Sun Shield without external filters...................................................22
Figure 7: AIrHarmony-4000 in prone position prior to external filters assembly ................................23
Figure 8: External Filters' Set ................................................................................................................23
Figure 9: External Filters' Set slots & fastenings ...................................................................................24
Figure 10: Mounting External Filters' set on Sun-shield .......................................................................24
Figure 11: Opening cover......................................................................................................................25
Figure 12. Cover opened....................................................................................................................... 25
Figure 13: Align and fit filter to connector............................................................................................ 26
Figure 14: Tighten screws on filter........................................................................................................26
Figure 15: Align and fit second filter to connector ...............................................................................27
Figure 16: Tighten filter bridge screws on Sun-Shield ..........................................................................27
Figure 17: Tighten screws on cover ......................................................................................................28
Figure 18: Attaching GPS antenna to unit............................................................................................. 28
Figure 19: Pole/Wall mounting plate....................................................................................................29

AirHarmony-4000 (External Cavity Filter) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use iv
Figure 20: Mounting plate on pole .......................................................................................................30
Figure 21: Through-bolt & Mounting plate...........................................................................................31
Figure 22: Pole/Wall mounting plate (w/o bolt)................................................................................... 31
Figure 23: Mounting plate mounted.....................................................................................................32
Figure 24: Mounting Plate on Wall .......................................................................................................33
Figure 25: Lift unit and fit the slotted holes unto studs on top of mounting plate.............................. 34
Figure 26: Align Pins..............................................................................................................................35
Figure 27: AirHarmony mounted on Wooden Pole ..............................................................................35
Figure 28: AirHarmony mounted on Concrete Pole .............................................................................36
Figure 29: AirHarmony being mounted on a Wall ................................................................................37
Figure 30: Grounding ............................................................................................................................38
Figure 31: Gland connector - copper ....................................................................................................40
Figure 32: Ethernet Cable through connector ...................................................................................... 40
Figure 33: LC duplex cable assembly ....................................................................................................41
Figure 34: Cable connector hook up to the board connector ..............................................................41
Figure 35: Slide on inner housing..........................................................................................................42
Figure 36: Slide over and click............................................................................................................... 43
Figure 37: AC connector........................................................................................................................43
Figure 38: AC Connector disassembled ................................................................................................ 44
Figure 39: Strip wire.............................................................................................................................. 44
Figure 40: power cable assembly..........................................................................................................44
Figure 41: Connector on cable..............................................................................................................44
Figure 42: Plug pins...............................................................................................................................45
Figure 43: Pin assignment.....................................................................................................................45
Figure 44: Attaching wires ....................................................................................................................45
Figure 45: Power cable attached to AirHarmony-4000 ........................................................................46
Figure 46: External Filter’s set removal ................................................................................................ 48
Figure 47: Cavity Filter set - pre-assembled..........................................................................................48
Figure 48: External Filter’s set replacement .........................................................................................50
Tables
Table 1: AirHarmony-4000DF B41 Full Band FCC Maximum Output TX Power...................................... 7
Table 2: AirHarmony-4000DH B41 High Band FCC Maximum Output TX Power ...................................7
Table 3: AirHarmony-4000DL B41 Low Band FCC Maximum Output TX Power..................................... 7
Table 4: AirHarmony-4000 ETSI Maximum Output TX Power ................................................................ 7
Table 5: Power Consumption..................................................................................................................7
Table 6: Typographic Conventions.......................................................................................................... 9
Table 7. Minimum Hardware Requirements ........................................................................................15
Table 8. Parts & Kits ..............................................................................................................................16
Table 9. Amperage Draw.......................................................................................................................19
Table 10: AirHarmony-4000 Physical Dimensions ................................................................................20
Table 11: AirHarmony-4000 Environment Compliance ........................................................................ 21
Table 12: Cable Hardware..................................................................................................................... 39
Table 13: Job Sheet ...............................................................................................................................51

AirHarmony-4000 (External Cavity Filter) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 1
Document Information
Abstract
This document details procedures for installing the Airspan’s AirHarmony-4000 EXT, a Macro-class
eNodeB variant and its place in the Airspan product suite. This document is intended for qualified
personnel with a working knowledge of LTE.
Revision History
Revision Details
Date
Summary of Changes
Rev 0.1
December 2015
Initial document - draft
Rev 0.2
January 2016
Changes from input - draft
1.0
January 2016
Final change prior to publish

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 2
Warnings and Cautions
Human Exposure to Radio Frequencies
The AirHarmony-4000 antennas should be operated from a minimum safe distance of 4.6m
Radio Interference
The AirHarmony generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment on and off, the technician is encouraged to try to correct the
interference by performing one or more of the following measures:
Re-orientate or relocate the unit
Increase separation between the units and/or End Devices
Connect the equipment to an outlet on a circuit different from that to which the power
source is connected
Modifications
Any changes and modifications to this device that are not expressly approved by Airspan Networks
may void the user's authority to operate the equipment.
General
Only qualified personnel should be allowed to install, replace, and service the equipment.
The device cannot be sold retail, to the general public or by mail order. It must be sold to
operators.
Installation must be controlled.
Installation must be performed by licensed professionals.
Installation requires special training. The AirHarmony-4000 should be installed ONLY by
experienced installation professionals who are familiar with local building and safety codes
and, wherever applicable, are licensed by the appropriate government regulatory
authorities. Failure to do so may void Airspan's product warranty and may expose the end
user or the service provider to legal and financial liabilities. Airspan and its resellers or
distributors are not liable for injury, damage or violation of regulations associated with the
installation of outdoor units or antennas.
The device is to be installed in a Restricted Access Location.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 3
Safety
1. Read this guide and follow all operating and safety instructions.
2. Keep all product information for future reference.
3. Static sensitive components inside - do not remove the lid or base: No user serviceable
parts inside.
4. Position the power cord to avoid possible damage.
5. Do not place this product on or near a direct heat source, and avoid placing objects on
the terminal.
6. To avoid electrical shock do not install this device during adverse conditions such as rain
or inclement weather.
7. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the
power before cleaning.
8. The units should not be located too near power lines or other electrical power circuits,
where it can come into contact with such power lines or circuits.
9. The radio transceiver must be properly grounded to protect against power surges and
accumulated static electricity. It is the user’s responsibility to install this device in
accordance with the local electrical codes.
10. Installation of the AirHarmony-4000 must be contracted to a professional installer.
11. Disconnect Device. The socket outlet should be easily accessible in case you have to
disconnect the device.
12. When installed in the final configuration, the product must comply with the applicable
Safety Standards and regulatory requirements of the country in which it is installed. If
necessary, consult with the appropriate regulatory agencies and inspection authorities
to ensure compliance.
Warning of Hazardous Voltages
On AC installations, hazardous voltages exist. Use caution when verifying or working with AC power.
Remove metal jewelry that could come into contact with AC power.
On DC sections, short-circuiting the low voltage, low impedance circuits can cause severe arcing that
may result in burns or eye damage. Remove rings, watches etc. to avoid shorting DC circuits.
Note: Airspan products do not contain hazardous substances (as defined in UK Control of Substances
Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990). At the end
of any Airspan products life cycle, the customer should consult with Airspan to ensure that the
product is disposed of in conformance with the relevant regulatory requirements.
Adherence to European Directive 1999/519/EC
European Council Recommendation 1999/519/EC details basic restrictions and reference levels on
human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these
recommended restrictions and reference levels should provide a high level of protection as regards
the established health effects that may result from exposure to electromagnetic fields.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 4
Warning Symbols
The following symbols may be encountered during installation or troubleshooting. These warning
symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in
working with electrical equipment and radio transmitters. Familiarize yourself with standard safety
practices before continuing.
Electro-Magnetic Radiation
High Voltage
Service Information
Refer all repairs to qualified service personnel. Do not modify any part of this device, as this will void
the warranty.
Disconnect the power to this product and return it for service if the following conditions apply:
a. The terminal does not function after following the operating instructions outlined in this
manual.
b. The product has been dropped or the housing is damaged.
Locate the serial number of the terminal and record this on your registration card for future
reference. Also record the MAC address, located on the product sticker.
UL Information
- The equipment must be properly grounded according with NEC and other local safety code
requirements.
- Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides
guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected
to the grounding system of the building, as close to the point of cable entry as is practical.
- AirHarmony-4000 is designed to operate in environmental conditions complying with IP66 and
relevant standards.
Lightning Protection
WARNING: The following notes are general recommendations for the system. The wireless
equipment should be installed by a qualified professional installer and must follow local and national
codes for electrical grounding and safety. Failure to meet safety requirements and/or use of non-
standard practices and procedures could result in personal injury and damage to equipment. A direct
lightning strike may cause serious damage even if these guidelines are followed.
All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced
current from a near strike. Lightning protection and grounding practices in local and national
electrical codes serve to minimize equipment damage, service outages, and serious injury. Reasons
for lightning damage are summarized as:
- Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 5
- Lack of properly installed lightning protection equipment that can cause equipment failures from
lightning induced currents.
A lighting protection system provides a means by which the energy may enter earth without passing
through and damaging parts of a structure. A lightning protection system does not prevent lightning
from striking; it provides a means for controlling it and preventing damage by providing a low
resistance path for the discharge of energy to travel safely to ground. Improperly grounded
connections are also a source of noise that can cause sensitive equipment to malfunction.
A good tower grounding system disperses most of the surge energy from a tower strike away from
the building and equipment.
To limit the equipment damage due to a lightning strike, the following practices are recommended
for the wireless system:
- Provide direct grounding from the antenna mounting bracket, the radio and antenna and the
lightning/surge protectors to the same ground point at the base of the tower or a ground bus on the
building. Use the grounding screws on the antenna bracket and the radio and antenna for
terminating the ground wires.
- The AC wall outlet ground must be connected to the same grounding system as the eNodeB.
DECLARATION OF CONFORMITY
European Community, Switzerland, Norway, Iceland, and Liechtenstein
Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC
English:
This equipment is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC.
Deutsch:
Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der
Richtlinie 1999/5/EU.
Dansk:
Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv
1999/5/EF.
Español:
Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC.
Greek:
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ
ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.
Français:
Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive
1999/5/EC.
Íslenska:
Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 6
Italiano:
Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC.
Nederlands:
Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC.
Norsk:
Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv
1999/5/EC.
Português:
Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.
Suomalainen:
Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen
mukainen.
Svenska:
Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i
Direktiv 1999/5/EC.
Român:
Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei
1999/5/CE.
GPS Compliance
The GPS is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC."
The GPS complies with the following EMC Common Regulatory Testing standards:
EN55022: Radiated and Conducted Emissions
CISPR 22: Class B
EN 50081-1: Generic Emissions Class B
EN 50082-1: Generic Immunity Class B
EN 61000-4-2: Electrostatic Discharge Immunity
EN 61000-4-3: Radiated RF EM Field Immunity Test
EN 61000-4-4: Electrical Fast Transient/Burst Test
EN 61000-4-6: Conducted Immunity
EN 61000-4-8: Magnetic Field Immunity
Note: A GPS is recommended for synchronizing between LTE sectors.
Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS
antenna in a remote location for lightning prone deployments.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 7
Maximum Output TX Power
Table 1: AirHarmony-4000DF B41 Full Band FCC Maximum Output TX Power
Frequency Band
FCC
TX EIRP
Antenna Gain
2496 –2690 MHz
46.19 dBm
64.19 dBm
18 dBi
Table 2: AirHarmony-4000DH B41 High Band FCC Maximum Output TX Power
Frequency Band
FCC
TX EIRP
Antenna Gain
2618 –2690 MHz
46.19 dBm
64.19 dBm
18 dBi
Table 3: AirHarmony-4000DL B41 Low Band FCC Maximum Output TX Power
Frequency Band
FCC
TX EIRP
Antenna Gain
2496 –2568 MHz
46.19 dBm
64.19 dBm
18 dBi
Table 4: AirHarmony-4000 ETSI Maximum Output TX Power
Frequency Band
ETSI
TX EIRP
Antenna Gain
2496 –2690 MHz
43dBm
TBDdBm
2/2 43dBi with External Duplexers
Caution: Do not set maximum output TX power to higher than local regulations.
Power Consumption
AirHarmony-4000 has a maximum nominal power consumption of 130W. AirHarmony-4000 power
consumption is described in the following table:
Table 5: Power Consumption
Duplex
Tx Power at RF Port
(dBm)
Nominal Power Consumption (W)
TDD- FC1
2 x 43
265
FDD
2 x 43
340

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 8
Antenna System
AirHarmony-4000 comes in a range of frequency variants that can be mounted with different
antenna options and formats. A typical installation will have a cross-polar sector or dual slant
antenna connected to the approprate Cavity filter of the AirHarmony-4000 variant unit. Various
antennas are designed specifically for AirHarmony-4000 deployments; specifications are available
from Airspan separately.
Long Switched Beam Antenna
Long Switched Beam antenna variant includes a steerable antenna mounted on the unit with the
following specification. The antenna is a multi-element cross polarized (dual slant) design which can
be used in directional or Omni modes of operation.
Scenario #1 - The long switched beam antenna is mounted directly on the unit and connected via its
two RF ports and the control port. The GPS antenna is either mounted on the top of the unit (if
conditions allow) or mounted separately with approved lightning protection.
Scenario #2 - The long switched beam antenna is mounted on the pole above the unit connected via
its two RF ports and the control port.
External Antenna
The externally mounted antenna should be a dual slant or cross polarized fixed antenna which are
connected via two (2) DIN connectors located on the top panel or to the external Cavity filter. The
antenna should be mounted to its appropriate mounting facility.
Note: When utilized in conjunction with iRelay as backhaul maintain a vertical separation of at least
1 meter.
Figure 1: AirHarmony-4000 with external cavity filters & cover

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 9
About This Document
Purpose
This guide provides the workflow and step-by-step procedures for installing the Airspan’s
AirHarmony-4000 Micro / Pico eNodeB variant. These procedures include:
Verify prerequisites
Assemble External Filters (Band 41)
Mount GPS
Install Mounting bracket
Install the AirHarmony-4000
Mount Antenna (either LSBA or external antenna)
Mount iRelay (if applicable)
Connect to External Antenna (if applicable)
Connect and manage cables
Field Replacement of Filter Set (when required)
Intended Audience
This guide is intended for persons who are responsible for installing the AirHarmony-4000.
These persons should have a working knowledge of the equipment.
AirHarmony can be tightly integrated with Airspan’s iBridge and iRelay transport solutions.
AirHarmony-4000 supports an integrated PoE interface which powers and connects either iBridge,
iRelay, or a third party WiFi Access Point. This configuration creates a single piece installation that
supports full end to end IPv6 plug and play deployment by just adding power. For more details
please refer to the iBridge and iRelay product specifications.
Document Conventions
This document uses the following typographic conventions.
Table 6: Typographic Conventions
Convention
Element
Blue underlined text
Cross-reference links.
Bold text
Keyboard buttons and GUI elements.
Command
Command names or phrases.
Computer output
Text displayed by the computer.
Hyperlinks
Website and e-mail addresses.
Danger
Signifies a hazardous situation—if not avoided—will cause
death or serious injury. Describes how to avoid it.
Warning
Signifies a hazardous situation—if not avoided—can cause
death or serious personal injury. Describes how to avoid it.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 10
Convention
Element
Caution
Signifies a hazardous situation—if not avoided—can void
the product warranty, and cause property damage.
Describes how to avoid it.
Important
Provides necessary information to explain a task.
Note
Provides additional information.
Tip
Provides helpful hints.
Document Organization
Chapter
Contents
Introduction
Provides a comprehensive overview of AirHarmony-4000 and its
installation.
Getting Started
Provides workflows for initial install and workflow.
Verifying Prerequisites
Lists the hardware, software, and client requirements for
installation.
AirHarmony-4000 Installation
Describes how to install AirHarmony-4000.
GPS Installation
Describes how to install the GPS antenna.
Connect and Manage Cables
Describes how to connect the cables.
Job Sheet
Provides information that aids users in performing the installation.
Abbreviations
Lists the abbreviations used in this document and their expansions.
Related Reading
The following documents contain related information:
AirHarmony-4000 Hardware Product Specification
Airspan LTE Commissioning Manual

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 11
Customer Care Help Desk
Airspan’s Customer Care Help Desk offers prompt and efficient customer support services.
Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must
have a valid support contract. To register, click here and fill the Registration form.
To create and update issue logs, send e-mails to Customer Care Help Desk. Once you submit your
issue, the system generates a new issue and sends an issue number for your reference. The system
uses this issue number to categorize and store e-mails under the appropriate issue.
To help Customer Care Help Desk identify your issue, include the issue number and your Customer
Care Helpdesk account details in all further communications.
Main Operations
Airspan Communications Ltd.
Capital Point
33 Bath Road
Slough, Berkshire
SL1 3UF, United Kingdom
Tel: +44-1895-467-100
Worldwide Headquarters
Airspan Networks Inc.
777, Yamato Road, Suite 105
Boca Raton, FL 3341-4408, USA
Tel: +1 561 893 8670
Airspan Encourages Comments
Airspan welcomes any feedback and suggestions that help to improve the quality of the

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 12
1Introduction
This section provides a descriptive overview of the Airspan’s AirHarmony-4000 with external cavity
filters a Macro-class eNodeB variant and its place in the Airspan product suite.
This document is intended for readers with LTE working knowledge.
All information in this document is for general information only, and is subject for change without
notice.
1.1 AirHarmony-4000
AirHarmony-4000 is part of Airspan’s carrier-class LTE Advanced small cell eNodeB family.
AirHarmony-4000 is a Macro-class product that supports 3GPP’s Long Term Evolution (LTE) eNodeB
specifications, providing high-speed data, mobility, Voice over LTE, and broadcast/multicast services
in order to meet the demands of the LTE Mobile Carriers.
AirHarmony-4000 is a compact, easy to install Macro-class eNodeB, allowing an operator to deploy
LTE broadband services using existing infrastructure or Street Furniture (e.g. street lamps, power
poles, building rooftop or sides etc…)
AirHarmony-4000 employs Software Defined Radio (SDR) technology, together with two transmit
and receive paths for each sector and a GPS antenna and receiver –all in a highly integrated,
physically small and light, All-Outdoor package, targeted to blend seamlessly into the urban
environment. This compact outdoor product minimizes physical footprint, power consumption and
operator OPEX.
AirHarmony-4000 is a 2T2R solution that enables a flexible deployment scenarios, but can achieve
higher coverage and throughput by combing multiple eNodeBs enabling the support of 4T4R, 4T8R,
and 8T8R.
AirHarmony-4000 implements 2 x 20W transmitters (2 x 43 dBm) and fully supports the standard LTE
(Uu/S1/X2) interfaces.
All Airspan eNodeB products, including AirHarmony-4000, are interoperable with a rich portfolio of
3rd party end user devices, including many handsets, indoor UEs, outdoor UEs and USB dongles from
several ODMs, using various chipsets. For an updated of interoperability list, please contact your
nearest Airspan Sales Representative.
Additionally, AirHarmony can be tightly integrated with Airspan’s iBridge and iRelay transport
solutions. AirHarmony-4000 supports an integrated PoE interface which powers and connects either
iBridge, iRelay, or a third party Wi-Fi Access Point. This configuration creates a single installation that
fully supports end to end IPv6 plug and play deployment by just adding power. For more details
please refer to the iBridge and iRelay product specifications.
Note: For management please refer to the Airspan LTE Commissioning Manual as well as Netspan.
1.2 Deployment
A highly flexible and scalable 4G Base Station, the AirHarmony-4000 is capable of supporting LTE
profiles across multiple frequency bands.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 13
Note: AirHarmony-4000 must be properly grounded according with NEC and other local safety code
requirements.
Figure 2: AirHarmony-4000 with External Filters & cover
Note: External Filters set are sold separately and are installed on site by the customer.

AirHarmony-4000 (External Cavity Filters) Installation Guide
UGD-D01019 Airspan Commercial and Internal Use 14
2Getting Started
2.1 Workflow of Installation
The Workflow to install the AirHarmony-4000 is displayed in the following diagram:
Figure 3: Workflow
Caution: Antennas and External filters must be connected and attached before AirHarmony-4000 is
powered on.
Table of contents
Other Airspan Network Hardware manuals

Airspan
Airspan AirSpeed 1000A User manual

Airspan
Airspan AirHarmony-1000 User manual

Airspan
Airspan AS MAX EasyST 4.9 Manual

Airspan
Airspan AIRSTAR 1900 User manual

Airspan
Airspan AirSpeed 1030 B48 User manual

Airspan
Airspan AirSynergy3 User manual

Airspan
Airspan AirSpeed 1050 B3 User manual

Airspan
Airspan AirHarmony-4400 User manual

Airspan
Airspan Sprint Magic Box User manual

Airspan
Airspan AirSpeed-1200 eNB Operating and maintenance instructions