Airspan AirHarmony-4400 User manual

AirHarmony-4400 Installation Guide
External Cavity Filters
Part Number: UGD-D01186
System Release: 15.0
Revision: A
Published: December 2016

© Copyright by Airspan Networks Ltd., 2016-2016. All rights reserved worldwide.
Legal Notices
The information contained within this document is proprietary, privileged and intended only for the recipient. As such, the
information is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any
specific agreements protecting Airspan Networks Ltd. rights in the aforesaid information. Neither this document nor the
information contained herein may be published, reproduced, transmitted or disclosed to third parties, in whole or in part,
without the express, prior, written permission of Airspan Networks Ltd. In addition, any use of this document or the
information contained herein for the purposes other than those for which it is disclosed is strictly forbidden.
Airspan Networks Ltd. reserves the right, without prior notice or liability, to make changes in equipment design or
specifications.
Information supplied by Airspan Networks Ltd. is believed in good faith to be accurate and reliable, while every care has
been taken in preparing these documents. However, Airspan Networks Ltd. does not make any representations and gives
no warranties of whatever nature in respect of these documents, including without limitation, the accuracy or
completeness of any information, facts and/or opinions contained therein. No responsibility is assumed by Airspan
Networks Ltd. for the use of the documents nor for the rights of third parties which may be effected in any way by the use
thereof. The provision of these documents (and the documents themselves) does not constitute professional advice of any
kind. Any representation(s) in these documents concerning performance of Airspan Networks Ltd. product(s) are for
informational purposes only and are not warranties of future performance, either expressed or implied. Airspan Networks
Ltd., its affiliates, directors, employees and agents shall not be held liable for any damages or losses, of any nature
whatsoever, arising from any use of and/or reliance on the documents.
These documents may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in
relation thereto unless specifically undertaken in Airspan Networks Ltd. sales contract or order confirmation. Information
contained herein is periodically updated and changes will be incorporated into subsequent editions. If you have
encountered an error, please notify Airspan Networks Ltd.
Product performance figures quoted within this document are indicative and for information purposes only.
UK WEEE Registration number: WEEE/AB0207WZ. For more information, see WEEE Information for Airspan
Customers and Recyclers.
Acknowledgements
© Intel Corporation http://www.intel.com/
© Microsoft Corporation http://www.microsoft.com

UGD-D01186 Airspan Commercial and Internal Use i
Table of Contents
Document Information ......................................................................................2
Abstract .................................................................................................................................2
Revision History.....................................................................................................................2
Warnings and Cautions ......................................................................................3
Human Exposure to Radio Frequencies ................................................................................3
Radio Interference ................................................................................................................3
Modifications ........................................................................................................................3
General..................................................................................................................................3
Général..................................................................................................................................3
Important Safety Instructions .........................................................................................4
Safety.....................................................................................................................................4
Securite..................................................................................................................................5
Warning of Hazardous Voltages............................................................................................5
Attention aux Voltages Hasardeux........................................................................................5
Adherence to European Directive 1999/5/EC.......................................................................6
Warning Symbols ..................................................................................................................6
Service Information...............................................................................................................6
UL Information ......................................................................................................................7
Lightning Protection..............................................................................................................7
Outdoor Ethernet Cabling .....................................................................................................8
DECLARATION OF CONFORMITY ...........................................................................................8
GPS Compliance ....................................................................................................................9
Maximum Output TX Total Power......................................................................9
Power Consumption............................................................................................................10
Antenna System ..................................................................................................................10
Long Switched Beam Antenna ............................................................................................10
External Antenna.................................................................................................................11

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use ii
About This Document ......................................................................................12
Purpose ...............................................................................................................................12
Intended Audience..............................................................................................................12
Document Conventions.......................................................................................................12
Document Organization ......................................................................................................13
Related Reading ..................................................................................................................13
Customer Care Help Desk ................................................................................14
Airspan Encourages Comments ..........................................................................................14
1Introduction.................................................................................................15
1.1AirHarmony-4400 ........................................................................................................15
1.2 Deployment .................................................................................................................15
2Getting Started ............................................................................................17
2.1 Workflow of Installation ..............................................................................................17
2.2 AirHarmony-4400 Installation Checklist......................................................................18
3Verifying Prerequisites.................................................................................18
3.1 Verifying Site Requirements ........................................................................................18
3.2 Verify Installation Requirements.................................................................................18
3.2.1 Verify the Tools ...........................................................................................................18
3.2.2 Verify the Parts and Kits.............................................................................................. 19
3.2.3 Power Supply and Current .......................................................................................... 21
3.2.4 Panels ..........................................................................................................................22
3.2.5 Physical Dimensions ....................................................................................................23
3.2.6 Environmental.............................................................................................................24
4Installing AirHarmony-4400 .........................................................................25
4.1 Rear External Filter Set Assembly................................................................................25
4.2 Front External Filter Set Assembly ..............................................................................28
4.3 Connecting the GPS Antenna ......................................................................................33
4.4 Pole/Wall Mount Assembly .........................................................................................35
4.4.1 Mounting on a Wooden Pole ......................................................................................35

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use iii
4.4.2 Mounting on a Non-Wooden Pole .............................................................................. 37
4.4.3 Mounting on a Wall..................................................................................................... 38
4.5 Securing AirHarmony-4400 to the Mounting Plate.....................................................40
5AirHarmony-4400 Connections ....................................................................44
5.1 Grounding ....................................................................................................................44
5.2 Remote Antenna Assembly .........................................................................................44
5.2.1 Connecting RF Jumper Cables to External Antenna.................................................... 44
5.2.2 Weather-proofing the Antenna Connections ............................................................. 45
5.3 Cable Connections .......................................................................................................46
5.3.1 Copper Ethernet Cable Assembly................................................................................46
Assembly Instructions.............................................................................................................46
5.4 Fiber Ethernet (SFP) Cable Installation........................................................................47
5.4.1 SFP Cable Connection..................................................................................................47
5.5 Connecting the AC Power Cable to AirHarmony-4400................................................49
5.5.1 Power Cable Preparation ............................................................................................49
5.5.2 Securing Connector Clamp.......................................................................................... 53
AJob Sheet .....................................................................................................54
BAbbreviations...............................................................................................55
Figures
Figure 1: AirHarmony-4400 with external cavity filters & cover ..........................................................11
Figure 2: AirHarmony-4400 with Front & Rear Filter Sets & cover ......................................................16
Figure 3: Workflow................................................................................................................................17
Figure 4: AirHarmony-4400 Unit, Bottom panel...................................................................................22
Figure 5: AirHarmony-4400 Unit, Top panel.........................................................................................23
Figure 6: AIrHarmony-4400 - in Horizontal Position prior to Rear External Filters Set Assembly........25
Figure 7: Rear External Filters' Set........................................................................................................26
Figure 8: Mounting Rear External Filters' set ....................................................................................... 26
Figure 9: Back Bracket Assembly ..........................................................................................................27
Figure 10: Fitting RF Connector ............................................................................................................ 27
Figure 11. Tighten the Filter Screws ..................................................................................................... 27
Figure 12: Tighten Hex Head Bolts........................................................................................................28
Figure 13: AIrHarmony-4400 in Prone Position Prior to Front External Filter Assembly......................28
Figure 14: External Filters' Set .............................................................................................................. 29

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use iv
Figure 15: External Filters' Set slots & fastenings................................................................................. 29
Figure 16: Mounting External Filters' set on Sun-shield .......................................................................30
Figure 17: Opening cover...................................................................................................................... 30
Figure 18. Cover opened.......................................................................................................................31
Figure 19: Align and fit filter to connector............................................................................................ 31
Figure 20: Tighten screws on filter........................................................................................................32
Figure 21: Align and fit second filter to connector ...............................................................................32
Figure 22: Tighten filter bridge screws on Sun-Shield .......................................................................... 33
Figure 23: Tighten screws on cover ...................................................................................................... 33
Figure 24: Attaching GPS antenna to unit............................................................................................. 34
Figure 25: Pole/Wall mounting plate....................................................................................................35
Figure 26: Mounting plate on pole .......................................................................................................36
Figure 27: Through-bolt & Mounting plate........................................................................................... 37
Figure 28: Pole/Wall mounting plate (w/o bolt)................................................................................... 37
Figure 29: Mounting plate mounted.....................................................................................................38
Figure 30: Mounting Plate on Wall .......................................................................................................39
Figure 31: Lift unit and fit the slotted holes unto studs on top of mounting plate .............................. 40
Figure 32: Align Pins..............................................................................................................................41
Figure 33: AirHarmony mounted on Wooden Pole ..............................................................................41
Figure 34: AirHarmony mounted on Concrete Pole .............................................................................42
Figure 35: AirHarmony being mounted on a Wall ................................................................................ 43
Figure 36: Grounding ............................................................................................................................44
Figure 37: DIN 4.1/9.5 connectors (external thread)............................................................................45
Figure 38: Gland connector - copper .................................................................................................... 46
Figure 39: Ethernet Cable through connector ...................................................................................... 46
Figure 40: LC duplex cable assembly ....................................................................................................47
Figure 41: Cable connector hook up to the board connector ..............................................................47
Figure 42: Slide on inner housing.......................................................................................................... 48
Figure 43: Slide over and click...............................................................................................................49
Figure 44: AC connector........................................................................................................................49
Figure 45: AC Connector disassembled ................................................................................................ 50
Figure 46: Strip wire.............................................................................................................................. 50
Figure 47: power cable assembly..........................................................................................................50
Figure 48: Connector on cable..............................................................................................................50
Figure 49: Plug pins............................................................................................................................... 51
Figure 50: Pin assignment..................................................................................................................... 51
Figure 51: Attaching wires ....................................................................................................................51
Figure 52: Connector Clamp .................................................................................................................52
Figure 53: Power cable attached to AirHarmony-4400 ........................................................................52
Figure 54: Securing the connection ...................................................................................................... 53
Tables
Table 1: AirHarmony-4400DF B41 Full Band FCC Maximum Output TX Total Power............................. 9
Table 2: AirHarmony-4400DH B41 High Band FCC Maximum Output TX Total Power ..........................9
Table 3: AirHarmony-4400DL B41 Low Band FCC Maximum Output TX Total Power..........................10
Table 4: AirHarmony-4400 ETSI Maximum Output TX Total Power .....................................................10
Table 5: Power Consumption................................................................................................................10

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use v
Table 6: Typographic Conventions........................................................................................................ 12
Table 7. Minimum Hardware Requirements ........................................................................................18
Table 8. Parts & Kits ..............................................................................................................................19
Table 9. Amperage Draw.......................................................................................................................22
Table 10: AirHarmony-4400 Physical Dimensions ................................................................................23
Table 11: AirHarmony-4400 Environment Compliance ........................................................................24
Table 12: Job Sheet ...............................................................................................................................54

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 2
Document Information
Abstract
This document details procedures for installing the Airspan’s AirHarmony-4400 EXT, a Macro-class
eNodeB variant and its place in the Airspan product suite. This document is intended for qualified
personnel with a working knowledge of LTE.
Revision History
Revision Details
Date
Summary of Changes
Rev 0.1
November 2016
Initial document –draft
Comments
Rev A
December 2016
Publish

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 3
Warnings and Cautions
Human Exposure to Radio Frequencies
The AirHarmony-4400 antennas should be operated from a minimum safe distance of 4.6m
Radio Interference
The AirHarmony generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment on and off, the technician is encouraged to try to correct the
interference by performing one or more of the following measures:
Re-orientate or relocate the unit
Increase separation between the units and/or End Devices
Connect the equipment to a circuit different from that to which the power source is
connected
Modifications
Any changes and modifications to this device that are not expressly approved by Airspan Networks
may void the user's authority to operate the equipment.
General
Only qualified personnel should be allowed to install, replace, and service the equipment.
The device cannot be sold retail, to the general public or by mail order. It must be sold to
operators.
Installation must be controlled.
Installation must be performed by licensed professionals.
Installation requires special training. The AirHarmony-4400 should be installed ONLY by
experienced installation professionals who are familiar with local building and safety codes
and, wherever applicable, are licensed by the appropriate government regulatory
authorities. Failure to do so may void Airspan's product warranty and may expose the end
user or the service provider to legal and financial liabilities. Airspan and its resellers or
distributors are not liable for injury, damage or violation of regulations associated with the
installation of outdoor units or antennas.
The device is to be installed in a Restricted Access Location.
Surge Arrestors and Transient Voltage Surge Suppressors installed external to the ITE are
required to comply with the appropriate CEC/NEC requirements.
Général
Seul le personnel qualifié peut être autorisé pour installer ou remplacer l’équipement ainsi
qu’effectuer les opérations de maintenance pour cet équipement.
L’équipement ne peut pas être vendu en grande distribution ou par commande via email à
destination du public. Il doit être vendu aux opérateurs de télécommunications.
Son installation doit être contrôlée.
Son Installation doit être effectuée par des professionnels autorises.

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 4
Son installation requiert une formation spécifique du personnel. L’AirHarmony-4400, radio
et antenne doit être installe UNIQUEMENT par des installateurs professionnels
expérimentés et ayant une connaissance des constructions locales et règles de sécurité, ainsi
que, dès que nécessaire, disposant d’un agreement des autorités gouvernementales de
régulation. Toute enfreinte a ces obligations peut annuler la garantie délivrée par Airspan
pour ces produits et peut exposer l’utilisateur final ou le fournisseur de services a des
dommages légaux et financiers.
Airspan et ses revendeurs ou ses distributeurs ne sont pas responsables des blessures,
dommages ou violations de la régulation en vigueur lies a l’installation du système extérieur
ou des antennes.
L’Equipment doit être installe dans une zone a accès réduit et contrôle.
Parafoudres et Protections contre les surtensions transitoires doivent etre installés a
l’exterieur de l’équipement ITE sont tenus de se conformer aux exigences relatives aux
normes CEC/NEC concernées
Important Safety Instructions
Read and Save these instructions
This Installation Guide contains instructions and warnings that should be followed during
installation, and operation.
Failure to follow these instructions could cause bodily injury and/or product failure
Safety
1. Read this guide and follow all operating and safety instructions.
2. Static sensitive components inside - do not remove the lid or base: No user serviceable
parts inside.
3. The ground connection should be made before connecting to supply connections.
4. Position the power cord to avoid possible damage; do not overload circuits.
5. Do not place this product on or near a direct heat source, and avoid placing objects on
the terminal.
6. To avoid electrical shock do not install this device during adverse conditions such as rain
or inclement weather.
7. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the
power before cleaning.
8. The units should not be located too near power lines or other electrical power circuits,
where it can come into contact with such power lines or circuits.
9. The radio transceiver must be properly grounded to protect against power surges and
accumulated static electricity. It is the user’s responsibility to install this device in
accordance with the local electrical codes.
10. Installation of the AirHarmony-4400 must be contracted to a professional installer.
11. The circuit breaker should be easily accessible in case you have to disconnect the device.
12. When installed in the final configuration, the product must comply with the applicable
Safety Standards and regulatory requirements of the country in which it is installed. If
necessary, consult with the appropriate regulatory agencies and inspection authorities
to ensure compliance.

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 5
Securite
1. Lire attentivement ce guide et suivre les instructions d’utilisation et de sécurité.
2. Des composants sensibles a électricité statique sont utilisés à l’intérieur. Ne pas retirer le
coffre ou la base. Aucune pièce a l’intérieur est d’utilité pour l’utilisateur.
3. La connexion "terre" doit être effectuée en priorité et avant d'effectuer les connexions à
la source d'alimentation (phase et neutre).
4. Positionner le cordon d’alimentation de façon à éviter des dommages potentiels. Ne pas
surcharger les circuits.
5. Ne pas placer ce produit sur ou à proximité d’une source directe de chaleur et éviter de
placer des objets sur le terminal.
6. Afin d’éviter des problèmes électriques, ne pas installer cet équipement au cours
d’évènements climatiques difficiles comme averses ou météo non clémente.
7. Utiliser uniquement chiffon de coton pour nettoyage. Ne pas utiliser de produits liquides
ou d’aérosols. Déconnecter le produit de la source d’alimentation avant nettoyage.
8. L’unité ne doit pas être située trop près de lignes électriques ou autres circuits de
puissance, avec lesquels il pourrait entrer en contact.
9. L’émetteur radio doit être correctement relie a la terre afin de le protéger contre les
surtensions ou accumulation d’électricité statique. L’utilisateur est tenu responsable de
l’installation du produit conformément aux règles électrique en vigueur localement.
10. L’installation de AirHarmony-4400 doit être contractualisée avec un installateur
professionnel.
11. L’interrupteur de circuit électrique doit être facilement accessible afin de pouvoir
déconnecter l’équipement.
12. Lors de l’installation de la configuration finale, le produit doit être conforme aux
Standards de Sécurité en vigueur ainsi qu’aux exigences réglementaires du pays dans
lequel il est installé. Si nécessaire, consulter les agences règlementaires appropriées,
ainsi que les autorités chargées de l’inspection afin de garantir la conformité.
Warning of Hazardous Voltages
On AC installations, hazardous voltages exist. Use caution when verifying or working with AC power.
Remove metal jewelry that could come into contact with AC power.
On DC sections, short-circuiting the low voltage, low impedance circuits can cause severe arcing that
may result in burns or eye damage. Remove rings, watches etc. to avoid shorting DC circuits.
Note: Airspan products do not contain hazardous substances (as defined in UK Control of
Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations
1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to
ensure that the product is disposed of in conformance with the relevant regulatory requirements.
Attention aux Voltages Hasardeux
Sur les installations de réseau électrique de type courant alternatif (CA), des voltages hasardeux
peuvent survenir. Garder une Attention particulière lors d’une vérification ou de travaux sur réseau
électrique CA. Retirer tous bijoux en métal qui pourraient entrer en contact avec l’alimentation ou le
réseau CA.

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 6
Sur les portions de réseau électrique de type courant continu (CC), un circuit basse impédance peut
causer de sérieux arcs électriques qui pourraient bruler ou endommager les yeux. Retirer bagues,
anneaux, montres etc… afin d’éviter les court-circuit sur le réseau CC.
Adherence to European Directive 1999/5/EC
European Council Recommendation 1999/5/EC details basic restrictions and reference levels on
human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these
recommended restrictions and reference levels should provide a high level of protection as regards
the established health effects that may result from exposure to electromagnetic fields.
Airspan equipment is compliant with CE and R&TTE regulations and can be operated in all EU
(European Union) locations listed below:
Country Code
BE
EL
LT
PT
BG
ES
LU
RO
CZ
FR
HU
SI
DK
HR
MT
SK
DE
IT
NL
FI
EE
CY
AT
SE
IE
LV
PL
UK
Warning Symbols
The following symbols may be encountered during installation or troubleshooting. These warning
symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in
working with electrical equipment and radio transmitters. Familiarize yourself with standard safety
practices before continuing.
Caution, hot surface
Caution
Electro-Magnetic
Radiation
High Voltage
Service Information
Refer all repairs to qualified service personnel. Do not modify any part of this device, as this will void
the warranty.
Disconnect the power to this product and return it for service if the following conditions apply:

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 7
a. The terminal does not function after following the operating instructions outlined in this
manual.
b. The product has been dropped or the housing is damaged.
Locate the serial number of the terminal and record this on your registration card for future
reference. Also record the MAC address, located on the product sticker.
UL Information
- The equipment must be properly grounded according with NEC and other local safety code
requirements.
- Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides
guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected
to the grounding system of the building, as close to the point of cable entry as is practical.
- AirHarmony-4400 is designed to operate in environmental conditions complying with IP66 and
relevant standards.
Lightning Protection
WARNING: The following notes are general recommendations for the system. The wireless
equipment should be installed by a qualified professional installer and must follow local and national
codes for electrical grounding and safety. Failure to meet safety requirements and/or use of non-
standard practices and procedures could result in personal injury and damage to equipment. A direct
lightning strike may cause serious damage even if these guidelines are followed.
All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced
current from a near strike. Lightning protection and grounding practices in local and national
electrical codes serve to minimize equipment damage, service outages, and serious injury. Reasons
for lightning damage are summarized as:
- Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment.
- Lack of properly installed lightning protection equipment that can cause equipment failures from
lightning induced currents.
A lighting protection system provides a means by which the energy may enter earth without passing
through and damaging parts of a structure. A lightning protection system does not prevent lightning
from striking; it provides a means for controlling it and preventing damage by providing a low
resistance path for the discharge of energy to travel safely to ground. Improperly grounded
connections are also a source of noise that can cause sensitive equipment to malfunction.
A good tower grounding system disperses most of the surge energy from a tower strike away from
the building and equipment.
To limit the equipment damage due to a lightning strike, the following practices are recommended
for the wireless system:
- Provide direct grounding from the antenna mounting bracket, the radio and antenna and the
lightning/surge protectors to the same ground point at the base of the tower or a ground bus on the
building. Use the grounding screws on the antenna bracket and the radio and antenna for
terminating the ground wires.

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 8
- The AC wall outlet ground must be connected to the same grounding system as the eNodeB.
Outdoor Ethernet Cabling
- Ethernet cable connected to should be outdoor grade with UV protection.
- Use shielded out CAT5e (minimum) cabled terminated with metallic RJ45 connectors.
- In order to protect the indoor unit, install surge protection circuits on all copper cables on their
entrance to the building.
- Surge protection circuit must use a minimum 16AWG grounding cable.
DECLARATION OF CONFORMITY
European Community, Switzerland, Norway, Iceland, and Liechtenstein
Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC
English:
This equipment is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC.
Deutsch:
Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der
Richtlinie 1999/5/EU.
Dansk:
Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv
1999/5/EF.
Español:
Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC.
Greek:
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ
ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.
Français:
Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive
1999/5/EC.
Íslenska:
Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB.
Italiano:
Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC.
Nederlands:
Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC.
Norsk:
Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv
1999/5/EC.
Português:
Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 9
Suomalainen:
Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen
mukainen.
Svenska:
Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i
Direktiv 1999/5/EC.
Român:
Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei
1999/5/CE.
The Declaration of Conformity related to this product can be obtained from PLM@Airspan.com.
GPS Compliance
The GPS is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC."
The GPS complies with the following EMC Common Regulatory Testing standards:
EN55022: Radiated and Conducted Emissions
CISPR 22: Class B
EN 50081-1: Generic Emissions Class B
EN 50082-1: Generic Immunity Class B
EN 61000-4-2: Electrostatic Discharge Immunity
EN 61000-4-3: Radiated RF EM Field Immunity Test
EN 61000-4-4: Electrical Fast Transient/Burst Test
EN 61000-4-6: Conducted Immunity
EN 61000-4-8: Magnetic Field Immunity
Note: A GPS is recommended for synchronizing between LTE sectors.
Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS
antenna in a remote location for lightning prone deployments.
Maximum Output TX Total Power
Table 1: AirHarmony-4400DF B41 Full Band FCC Maximum Output TX Total Power
Frequency Band
FCC
TX EIRP
Antenna Gain
2496 –2690 MHz
46.20 dBm
64.20 dBm
18dBi
Table 2: AirHarmony-4400DH B41 High Band FCC Maximum Output TX Total Power
Frequency Band
FCC
TX EIRP
Antenna Gain
2618 –2690 MHz
46.20 dBm
64.20 dBm
18dBi

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 10
Table 3: AirHarmony-4400DL B41 Low Band FCC Maximum Output TX Total Power
Frequency Band
FCC
TX EIRP
Antenna Gain
2496 –2568 MHz
46.20 dBm
64.20 dBm
18dBi
Table 4: AirHarmony-4400 ETSI Maximum Output TX Total Power
Frequency Band
ETSI
TX EIRP
Antenna Gain
2496 –2690 MHz
46 dBm
64 dBm
18dBi
Caution: Do not set maximum output TX power to higher than local regulations.
Power Consumption
AirHarmony-4400 power consumption is described in the following table:
Table 5: Power Consumption
Duplex
Tx Power at RF Port (dBm)
Nominal Power Consumption (W)
TDD- FC1
2 x 43
265
FDD
2 x 43
340
Antenna System
AirHarmony-4400 comes in a range of frequency variants that can be mounted with different
antenna options and formats. A typical installation will have a cross-polar sector or dual slant
antenna connected to the approprate Cavity filter of the AirHarmony-4400 variant unit. Various
antennas are designed specifically for AirHarmony-4400 deployments; specifications are available
from Airspan separately.
Long Switched Beam Antenna
Long Switched Beam antenna variant includes a steerable antenna mounted on the unit with the
following specification. The antenna is a multi-element cross polarized (dual slant) design which can
be used in directional or Omni modes of operation.
Scenario #1 - The long switched beam antenna is mounted directly on the unit and connected via its
two RF ports and the control port. The GPS antenna is either mounted on the top of the unit (if
conditions allow) or mounted separately with approved lightning protection.
Scenario #2 - The long switched beam antenna is mounted on the pole above the unit connected via
its two RF ports and the control port.

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 11
External Antenna
The externally mounted antenna should be a dual slant or cross polarized fixed antenna which are
connected via two (2) DIN connectors located on the top panel or to the external Cavity filter. The
antenna should be mounted to its appropriate mounting facility.
Note: When utilized in conjunction with iRelay as backhaul maintain a vertical separation of at least
2 ft. (0.6 m).
Figure 1: AirHarmony-4400 with external cavity filters & cover

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 12
About This Document
Purpose
This guide provides the workflow and step-by-step procedures for installing the Airspan’s
AirHarmony-4400 Macro-class eNodeB variant. These procedures include:
Verify prerequisites
Assemble Front Filter set
Assemble Rear Filter set
Mount GPS
Install Mounting bracket
Install the AirHarmony-4400
Mount Antenna (either LSBA or external antenna)
Mount iRelay (if applicable)
Connect to External Antenna (if applicable)
Connect and manage cables
Intended Audience
This guide is intended for persons who are responsible for installing the AirHarmony-4400.
These persons should have a working knowledge of the equipment.
AirHarmony can be tightly integrated with Airspan’s iBridge and iRelay transport solutions.
AirHarmony-4400 supports an integrated PoE interface which powers and connects either iBridge,
iRelay, or a third party WiFi Access Point. This configuration creates a single piece installation that
supports full end to end IPv6 plug and play deployment by just adding power. For more details
please refer to the iBridge and iRelay product specifications.
Document Conventions
This document uses the following typographic conventions.
Table 6: Typographic Conventions
Convention
Element
Blue underlined text
Cross-reference links.
Bold text
Keyboard buttons and GUI elements.
Command
Command names or phrases.
Computer output
Text displayed by the computer.
Hyperlinks
Website and e-mail addresses.
Danger
Signifies a hazardous situation—if not avoided—will cause
death or serious injury. Describes how to avoid it.
Warning
Signifies a hazardous situation—if not avoided—can cause
death or serious personal injury. Describes how to avoid it.

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 13
Convention
Element
Caution
Signifies a hazardous situation—if not avoided—can void
the product warranty, and cause property damage.
Describes how to avoid it.
Important
Provides necessary information to explain a task.
Note
Provides additional information.
Tip
Provides helpful hints.
Document Organization
Chapter
Contents
Introduction
Provides a comprehensive overview of AirHarmony-4400 and its
installation.
Getting Started
Provides workflows for initial install and workflow.
Verifying Prerequisites
Lists the hardware, software, and client requirements for
installation.
AirHarmony-4400 Installation
Describes how to install AirHarmony-4400.
GPS Installation
Describes how to install the GPS antenna.
Connect and Manage Cables
Describes how to connect the cables.
Job Sheet
Provides information that aids users in performing the installation.
Abbreviations
Lists the abbreviations used in this document and their expansions.
Related Reading
The following documents contain related information:
AirHarmony-4400 Hardware Product Specification
Airspan LTE Commissioning Manual

AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186 Airspan Commercial and Internal Use 14
Customer Care Help Desk
Airspan’s Customer Care Help Desk offers prompt and efficient customer support services.
Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must
have a valid support contract. To register, click here and fill the Registration form.
To create and update issue logs, send e-mails to Customer Care Help Desk. Once you submit your
issue, the system generates a new issue and sends an issue number for your reference. The system
uses this issue number to categorize and store e-mails under the appropriate issue.
To help Customer Care Help Desk identify your issue, include the issue number and your Customer
Care Helpdesk account details in all further communications.
Main Operations
Airspan Communications Ltd.
Capital Point
33 Bath Road
Slough, Berkshire
SL1 3UF, United Kingdom
Tel: +44-1895-467-100
Worldwide Headquarters
Airspan Networks Inc.
777, Yamato Road, Suite 105
Boca Raton, FL 3341-4408, USA
Tel: +1 561 893 8670
Airspan Encourages Comments
Airspan welcomes any feedback and suggestions that help to improve the quality of the
Table of contents
Other Airspan Network Hardware manuals

Airspan
Airspan Sprint Magic Box User manual

Airspan
Airspan AS MAX EasyST 4.9 Manual

Airspan
Airspan AirHarmony-4000 User manual

Airspan
Airspan AirSpeed 1000A User manual

Airspan
Airspan AirSpeed 1030 B48 User manual

Airspan
Airspan AirSpeed 1050 B3 User manual

Airspan
Airspan AIRSTAR 1900 User manual

Airspan
Airspan AS4000 Guide

Airspan
Airspan AirSynergy3 User manual

Airspan
Airspan AS3010 Manual
Popular Network Hardware manuals by other brands

Garland
Garland EdgeSafe M40G1AC user guide

WIN Enterprises
WIN Enterprises PL-10590 user manual

Renesas
Renesas YCONNECT-IT-RZN2L user manual

SMC Networks
SMC Networks ElliteConnect 2.4GHz/5GHz owner's manual

Nokia
Nokia XS-2426G-B Product guide

ZyXEL Communications
ZyXEL Communications Prestige 2602R Series user guide