MULTITASKER™
17
Cause 2: The card is not recognized.
Solution: Reset the card cage by sending the
[RES] command, or turning the
system power off and then on again.
Send the [C] command to see if
there is communication with the
card. If there is no feedback, see
Cause 3.
Cause 3: Card is not plugged in all the way.
Solution: Push the card in all the way. Reset
the system and send the [C]
command. If the card is still not
recognized and the LED is not on,
see Cause 4.
Cause 4: Card cage slot has a problem.
Solution 1: Test the card in other slots of the
card cage. If the slot was damaged,
the card may work in other slots. If
other slots work and the card is
recognized, the problem is the card
cage slot. The card cage may
require service. Call ALTINEX at
(714) 990-2300. If the other slots do
not work, see Solution 2.
Solution 2: Take any other known good card
and verify that the slot used is good
by seeing if the other car is
recognized in that slot. If it is, then
the original card may be the source
of the problem. Call ALTINEX at
(714) 990-2300.
8.2 LED IS NOT GREEN (VGA)
Cause 1: There is no power.
Solution: Disconnect the video input from the
MT103-122 and verify the LED is
ON and RED indicating power is
present. Reconnect the computer's
video output. If the LED is still not
GREEN see Cause 2.
Cause 2: There is no Sync signal.
Solution: Verify the computer output is
operating correctly by connecting it
directly to the local monitor. If the
display is good, call ALTINEX at
(714) 990-2300.
8.3 NO DISPLAY
Cause 1: The source has a problem.
Solution: Check the source and make sure
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no display, see Cause 2.
Cause 2: Cable connections are incorrect.
Solution: Make sure that cables are properly
connected. Also, make sure that the
continuity and wiring are good. If
there is still no display present, see
Cause 3.
Cause 3: There is no input signal.
Solution: Verify the card is receiving a valid
signal at the input using the Signal
Detect command, [SIG]. See
RS-232 accessible commands in
Section 7. If no signal is detected,
see Solution 2. If a signal is
detected, see Cause 4.
Cause 4: Equalization is set too high.
Solution: Make sure the equalization is set to
minimum to start. If controlling the
equalization using the built-in
potentiometer, verify the EQ switch
on the board is set to HW. See
DIAGRAM 4for details.
Cause 5: The display has a problem.
Solution: Make sure that the display has
power and is turned ON. If there is
still no display, call ALTINEX at
(714) 990-2300.