#852 • AR-7E Rotisserie Operation & Care Manual • 6
I N S TA L L AT I O N
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “OFF” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
After wiring and power connection has been
completed, turn the main power switch to the “ON”
position. The main power switch can be left “ON”
for daily use, but should be turned “OFF” when
cleaning or performing maintenance or repairs to
the rotisserie.
REGARDING INTERNATIONAL
STANDARD UNITS:
If the unit is not equipped with flexible cord
with plug, an all-pole country approved
disconnection device which has a contact
separation of at least 3mm in all poles must be
incorporated in the fixed wiring for disconnection.
When using a cord without a plug, the
green/yellow conductor shall be connected to the
terminal which is marked with the ground symbol.
If a plug is used, the socket outlet must be easily
accessible. If the power cord needs replacement,
use a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock
hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts to
provide sufficient protection against potential
difference. The terminal is marked with the
following symbol.
E L E C T R I C A L C O N N E C T I O N
ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS k
208 1 50/60 33.0 8.3
230 1 35.0 9.0 NO PLUG
240 1 32.0 8.8
208/220 3 50/60 40.0/ph 8.3
230 3 42.0/ph 9.0 NO PLUG
240 3 38.0/ph 8.8
380/415 3 22.0/ph 8.8 NO CORD
AX NO PLUG
THE ROTISSERIE CAN BE HARD WIRED.
PER ANENT WIRING FOR ALL OVENS UST BE
INSTALLED BY A LICENSED ELECTRICIAN IN
ACCORDANCE WITH APPLICABLE, LOCAL
ELECTRICAL CODES.
230V ROTIS SERIES FOR H ARD WIRING
UST BE EQUIPPED WITH AN EXTERNAL
AIN SWITCH WHICH DISCONNECTS ALL
POLES WITH A CONTACT SE PARATIO N O F
AT LEAST 3mm FOR ALL POLES.
“WARNING” RISK OF FIRE!
Use a UL Listed grounding type plug rated 250 Volts, 50
Amperes, 1 Phase, 3 wire for single phase units and 250 V,
30 A, 3 Phase, 4 wire for three phase units. Plug to be
selected and installed only by qualified service personnel.
Individual conductors are marked L1, L2, L3when
applicable, N when applicable, and G.