GAS COMBITHERM — I N S TA L L A T I O N M A N U A L #MN 28676
PG.5
COMBITHERM
10•10ESG SPECIFICATIONS
C A PA C I T Y
ULL-SIZE PANS: 20" x 12" x 2-1/2" Ten (10) Eight (8)
GN 1/1: 530 x 325 x 65mm Ten (10) Eight (8)
HAL -SIZE SHEET PANS:* 18" x 13" x 1" Ten (10) Nine (9)
ON WIRE SHE VES ON Y
120 lb (54 kg) MAXIMUM
VOLUME MAXIMUM: 75 QUARTS (95 LITERS)
WEIGHT
NET 490 lb EST. (222 kg) EST.
SHIP 530 lb EST. (240 kg) EST.
CRATE 50" X45" X40" EST.
DIMENSIONS:(1270 x 1143 x 1016mm)
E L E C T R I C A L 1 0 • 1 0 E S G 1 0 • 1 0 E S G / s k
VO TAGE PHASE CYC E/HZ AWG AMPS kW AMPS kW
110 - 120 1 50/60 2 Wire plus ground, AWG 12 5.7 .68 9.5 1.14
OTHER VOLTAGES AVAILABLE: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
21-11/16"
(550mm)
5-1/2"
(140mm)
42-1/16" (1068mm)
40-1/8"
(1018mm)
37" (939mm)
34-5/16"
(871mm)
Water Drain
(Bottom)
5" (125mm)
3-1/16"
(76mm)
37-3/8" (949mm)
43-5/8" (1108mm)
Steam
Vent
(Top)
Untreated Water
Intake (Bottom)
Electrical
Connection (Bottom)
Gas Connection
(Bottom)
2" (50mm)
47-5/16" (1201mm)
58-3/16" (1478mm)
2-3/8" (60mm)
10-5/8
"
(270mm)
19-3/8"
(492mm)
15-5/8"
(396mm)
Water Drain
(Side Back)
25"
(635mm)
7-1/2"
(191mm)
6-1/4" (159mm)
5-1/2" (140mm)
Treated Water Intake (Bottom)
11-1/2" (292mm)
3-5/8"
(92mm)
D I M E N S I O N S : H x W x D
EXTERIOR:
43-5/8" x 42-1/16" x 37" (1108mm x 1068mm x 939mm)
EXTERIOR WITH RETRACTAB E DOOR:
43-5/8" x 46-1/16" x 37" (1108mm x 1170mm x 939mm)
INTERIOR:
27-3/8" x 17-3/8" x 26-13/16" (695mm x 440mm x 680mm)
*ADDITIONAL WIRE SHELVES REQUIRED OR MAXIMUM CAPACITY
C L E A R A N C E R E Q U I R E M E N T S
EFT: 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) FR O M H E AT P R O D U C I N G E Q U I P M E N T
RIGHT: 4" (102mm) TOP: 20" (508mm) OR AIR MOVEMENT
BACK: 4" (102mm) BOTTOM: 5-1/8" (130mm) OR LEGS
COUNTER-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm)
MINIMUM CLEARANCE ROM THE COUNTER SUR ACE.
G A S R E Q U I R E M E N T S
CONNECTED ENERGY OAD:68,000 Btu/hr
HOOK-UP:3/4" NPT
MINIMUM CONNECTED PRESSURE:5.5" W.C. (Natural Gas)
9" W.C. (Propane)
MAXIMUM CONNECTED PRESSURE:14" W.C.
GAS TYPE MUST BE SPECIFIED ON ORDER.
WAT E R R E Q U I R E M E N T S
TWO (2) CO D WATER IN ETS - DRINKING QUA ITY
ONE (1) TREATED WATER IN ET:3/4" NPT*
ONE (1) UNTREATED WATER IN ET:3/4" NPT*
INE PRESSURE:30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
INSTALLATION REQUIREMENTS
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure
that incoming water supply is compliant with the specifications
listed through adequate treatment measures. Installation of the
CombiGuard™ Water iltration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements (untreated water)
ree Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm