QUICK START GUIDE
MXT-1000 10.1" Modero X®Series Tabletop Touch Panel
Overview
The MXT-1000 10.1" Modero X Series®Tabletop Touch Panel (FG5968-03)
features edge-to-edge capacitive touch glass with multi-touch capabilities. It
features advanced technology empowering users to operate AV equipment
seamlessly, while providing the ultimate in audio and video quality. The distinctive
appearance will complement even the most sophisticated meeting facilities and
homes.
Product Specifications
Note: The MXT-1000-NC (FG5968-24) No Comm touch panel does not have
camera, microphone, or NFC capability. It otherwise has all of the functionality of
the MXT-1000 panel
Connector Locations
USB peripherals (mouse, keyboard, etc.) may be connected to either of the two
USB ports on the rear of the device. Updates to the device’s firmware can also
made via the USB ports (FIG. 2).
Power via PoE
Power for the MXT-1000 is supplied via PoE (Power Over Ethernet ), utilizing an
AMX-certified, capacitive touch-compliant PoE injector such as the PS-POE-AT
High Power PoE Injector (FG423-81) or other approved AMX PoE power source
Connect the incoming Ethernet cable to the RJ45 port on the cable attached to
the device.
Ethernet Cable Installation and Modif ication
In installations where you wish to conceal the Ethernet cable, a hole at least 1.00”
(2.54 cm) in diameter is required in the surface to allow passage of the female
RJ45 connector (FIG. 3).
If using a smaller hole is unavoidable, you will need to disconnect the Ethernet
cable (ECA5968-05) from the device, to feed the male end of the cable through.
Note: The minimum diameter hole through which the Ethernet cable may pass is
0.50" (1.27 cm).
To disconnect and reconnect the MXT-1000’s Ethernet cable:
1. On a soft surface, turn the MXT-1000 face-down to access the bottom of the
device.
2. Remove the clamp holding the Ethernet cable (FIG. 3).
3. Remove the Ethernet cable connector and pull the cable out of the clamp.
4. Pass the Ethernet cable (ECA5968-05) through the hole, with the RJ45
connector on the other side of the installation surface from the device.
5. Press the Ethernet cable back into the clamp.
Do NOT tighten the clamp at this time.
6. Using a non-conductive item such as a wooden stick, reinsert the Ethernet
cable connector into the device. Ensure that the connector is properly
seated.
7. Tighten the clamp to secure the Ethernet cable.
Make sure the clamp is around the bundled black cable, not the individual
wires.
8. Connect the RJ45 connector to its incoming Ethernet cable and apply power.
FIG. 1 MXT-1000
MXT-1000 SPECIF ICATIONS
Dimensions (HWD) 6 7/8" x 9 7/8" x 4 7/8" (174mm x 252mm x 124mm)
Weight 3.0 lbs (1.36 Kg)
Power
Consumption
• Full-On: 8W
• Standby: 3.2W
• Shutdown: 1W
• Start-Up Inrush Current: Not applicable due to PoE standard
External Power
Supply Required
Optimal performance requires use of one of the following AMX
PoE power supplies (not included):
• PS-POE-AF-TC, PoE Injector, 802.3AF Compliant (FG423-83)
• NXA-ENET8-2POE, Gigabit PoE Ethernet Switch (FG2178-63)
Certifications • UL 60950-1
• FCC Part 15 Class B
• C-Tick CISPR 22 Class B
• CE EN 55022, EN 55024 and EN 60950-1
•IEC60950-1
•IC
•IEC/EN-60950
• RoHS/WEEE compliant
Environmental • Temperature (Operating): 32°F to 104°F (0°C to 40°C)
• Temperature (Storage): 4°F to 140°F (-20°C to 60°C)
• Humidity (Operating): 20% to 85% RH
• Humidity (Storage): 5% to 85% RH
• Power ("Heat") Dissipation:
On: 21.3 BTU/hr
Standby: 10.6 BTU/hr
Included
Accessories
• MXA-USB-C, USB Port Cover Kit, Modero X/S Series Touch
Panel (FG5968-18)
• 3/4" Mini-Grommet (FG570-01)
• MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16)
Sleep Button
NFC Sensor
USB Ports (2)
Sleep Button
FIG. 2 MXT-1000 - REAR VIEW
FIG. 3 BOTTOM OF THE MXT-1000
USB Ports Entry for RJ45/PoE Cable
Speaker
Sleep button
Ethernet Cable Connector
Clamp
© 2015 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are
registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks
of their respective companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
93-5968-03 REV: M
Last Revised: 6/22/2015
Powering On/Off X Series G5 Panels
Modero X Series G5 touch panels may be powered on by touching and holding the
Sleep button. To power off the panel, press and hold the Sleep button, and select
Power Off on the on-screen menu (FIG. 4):
Conf iguration and Programming
X Series G5 touch panels are equipped with a Settings menu that provides the
ability to configure various features on the panels.
To acce ss th e Settings menu, press and hold the Sleep button, and select
Settings.
Note: Information on the Settings menu, panel configuration, and programming is
provided in the Modero X Series G5 Programming Guide, available at www.amx.com.
Setting the Panel’s Device Number and Device Name
1. In the Settings menu, select NetLinx. This opens a password keypad.
2. Enter the panel password into the keypad (the default is 1988) and select
OK to access the NetLinx page.
3. Press Device Number to open the NetLinx editing window.
4. Enter a unique Device Number assignment for the panel and press OK.
5. Enter a unique Device Name assignment for the panel and press OK.
Conf iguring the Panel’s IP Address
The first step is to configure the panel’s IP address. Note that this only configures
the panel to communicate with a network; it is still necessary to connect to the
NetLinx Master (see Connecting to a NetLinx Master below).
Network Communication via DHCP
1. In the Ethernet page, press DHCP/Static field to open the DHCP/Static
window. Note that DHCP is the default setting.
2. Select Host Name, enter the new host name
3. Press OK to save changes.
Network Communication via Static Address
1. In the Ethernet page, press DHCP/Static to open the DHCP/Static window.
2. Select Static to open the Static IP window.
3. Press any field to open a keypad or keyboard (depending on the field), and
enter the appropriate network address information.
4. Press OK to save your changes and return to the Ethernet page.
Connecting to a NetLinx Master
To establish the type of connection to make between the panel and the NetLinx
Master:
1. In the NetLinx page, press Mode to choose the connection mode (URL,
Listen or Auto):
2. If password security is enabled on the target Master, enter the Username
and Password:
a. Select Username to open the NetLinx window.
b. Enter the Username and Password required by the Master.
c. Press OK to save changes and return to the NetLinx page.
Related Software and Additional Documentation (at www.amx.com)
• Programming the Modero X Series touch panels requires the use of the
latest versions of NetLinx Studio and TPDesign4, both available to download
at www.amx.com. Refer to the NetLinx Studio and TPDesign4 online help for
information.
• For additional information on the MXT-1000 panel, refer to the X-Series
Touch Panels MXD/T-1000, MXD/T-700 & MXD-430 Instruction Manual.
• For detailed information on the Settings menu as well programming
information and instructions on upgrading firmware, refer to the Modero X
Series Programming Guide.
• Detailed specifications drawings for the MXT-1000 are available to
download from www.amx.com.
FIG. 4 SLEEP BUTTON - PRESS AND HOLD TO ACCESS POWER OFF/SETTINGS OPTIONS
CONNECTION MODES
Mode Description Procedures
URL The device connects to the
target Master’s IP address
via a TCP connection.
1) Select URL in the Mode menu.
2) Enter the Master IP/URL, Master Port
Number, and Username/Password (if
required by the Master).
3) Press OK to save changes.
Listen This mode allows the panel
to “listen” for the Master’s
communication signals.
Note that in this mode, the
System Number and Master
IP/URL fields are read-only.
1) Select Listen in the Mode menu.
2) Confirm the panel’s IP address is on the
Master’s URL list (via NetLinx Studio).
3) Press OK to save changes.
Note: The Host Name (set on the Ethernet
page), can be used to locate the panel on the
Master (particularly useful for DHCP
connections where the IP address can change).
Auto Use this mode when both
the panel and the NetLinx
Master are on the same
Subnet.
1) Select Auto in the Mode menu.
2) Enter the System Number and Username
and Password (if applicable).
3) Press OK to save changes.

Other manuals for MXT-1000

1

This manual suits for next models

1

Other AMX Touch Panel manuals

AMX Modero NXT-1200V Parts list manual

AMX

AMX Modero NXT-1200V Parts list manual

AMX AXP-EL2 Quick start guide

AMX

AMX AXP-EL2 Quick start guide

AMX Modero NXD-CV5 Parts list manual

AMX

AMX Modero NXD-CV5 Parts list manual

AMX AXW-MLC Guide

AMX

AMX AXW-MLC Guide

AMX MSD-431-L User manual

AMX

AMX MSD-431-L User manual

AMX MVP-9000i User manual

AMX

AMX MVP-9000i User manual

AMX Modero NXV-300 User manual

AMX

AMX Modero NXV-300 User manual

AMX VPN-CP User manual

AMX

AMX VPN-CP User manual

AMX Modero ViewPoint MVP-5100 User manual

AMX

AMX Modero ViewPoint MVP-5100 User manual

AMX MST-1001 User manual

AMX

AMX MST-1001 User manual

AMX Modero NXT-1500VG Parts list manual

AMX

AMX Modero NXT-1500VG Parts list manual

AMX AXT-CA10 User manual

AMX

AMX AXT-CA10 User manual

AMX Modero MXT-1001 User manual

AMX

AMX Modero MXT-1001 User manual

AMX Modero NXD-1200V Parts list manual

AMX

AMX Modero NXD-1200V Parts list manual

AMX AXU-EL Plus Guide

AMX

AMX AXU-EL Plus Guide

AMX Modero ViewPoint MVP-8400 Parts list manual

AMX

AMX Modero ViewPoint MVP-8400 Parts list manual

AMX MXD-1900L-PAN Parts list manual

AMX

AMX MXD-1900L-PAN Parts list manual

AMX Modero ViewPoint MVP-8400i User manual

AMX

AMX Modero ViewPoint MVP-8400i User manual

AMX Color Active-Matrix LCD User manual

AMX

AMX Color Active-Matrix LCD User manual

AMX Modero NXD-500i User instructions

AMX

AMX Modero NXD-500i User instructions

AMX 10.4 TOUCH PANELS (G3 FIRMWARE) User manual

AMX

AMX 10.4 TOUCH PANELS (G3 FIRMWARE) User manual

AMX Modero NXD-1700VG User manual

AMX

AMX Modero NXD-1700VG User manual

AMX AXD-EL Plus User manual

AMX

AMX AXD-EL Plus User manual

AMX AXU-CA10 Quick start guide

AMX

AMX AXU-CA10 Quick start guide

Popular Touch Panel manuals by other brands

B&R Industries Power Panel 300 user manual

B&R Industries

B&R Industries Power Panel 300 user manual

Beijer Electronics X2 pro 12-B2 Hardware and installation manual

Beijer Electronics

Beijer Electronics X2 pro 12-B2 Hardware and installation manual

SGB LAE 3-8 Documentation

SGB

SGB LAE 3-8 Documentation

Extron electronics TLP Pro 1725TG Setup guide

Extron electronics

Extron electronics TLP Pro 1725TG Setup guide

Winmate P Series quick start guide

Winmate

Winmate P Series quick start guide

syslogic C Series User documentation

syslogic

syslogic C Series User documentation

Siemens SIMATIC 870 V2 quick start

Siemens

Siemens SIMATIC 870 V2 quick start

Bpt KHSO installation instructions

Bpt

Bpt KHSO installation instructions

ONESIGHT SystemView10 manual

ONESIGHT

ONESIGHT SystemView10 manual

Mitsubishi Electric AT-50A Instruction book

Mitsubishi Electric

Mitsubishi Electric AT-50A Instruction book

Graff Aqua-Sense Manual instruction

Graff

Graff Aqua-Sense Manual instruction

MBA Instruments MBA200 Operating	 instruction

MBA Instruments

MBA Instruments MBA200 Operating instruction

Terasic VEEK-MT-C5SOC user manual

Terasic

Terasic VEEK-MT-C5SOC user manual

Beckhoff CP6606-0001-0020 Installation and operating instructions

Beckhoff

Beckhoff CP6606-0001-0020 Installation and operating instructions

Winmate W10IB3S-EHH2 quick start guide

Winmate

Winmate W10IB3S-EHH2 quick start guide

ICOP Technology PPC-090T-APL-N4-4G user manual

ICOP Technology

ICOP Technology PPC-090T-APL-N4-4G user manual

Panasonic TY-TP42P8-S Service manual

Panasonic

Panasonic TY-TP42P8-S Service manual

Dometic BI01 Installation and operating manual

Dometic

Dometic BI01 Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.