logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ANTAIRA
  6. •
  7. Media Converter
  8. •
  9. ANTAIRA IMC-C1000 Series User manual

ANTAIRA IMC-C1000 Series User manual

Other manuals for IMC-C1000 Series

2

Other ANTAIRA Media Converter manuals

ANTAIRA FCS-3312WX User manual

ANTAIRA

ANTAIRA FCS-3312WX User manual

ANTAIRA IMP-C1000-SFP-bt Series User manual

ANTAIRA

ANTAIRA IMP-C1000-SFP-bt Series User manual

ANTAIRA IMC-C1000 Series User manual

ANTAIRA

ANTAIRA IMC-C1000 Series User manual

ANTAIRA IMP-C1000-SFP-bt-24 Series User manual

ANTAIRA

ANTAIRA IMP-C1000-SFP-bt-24 Series User manual

ANTAIRA IMC-C1000-SFP Series User manual

ANTAIRA

ANTAIRA IMC-C1000-SFP Series User manual

ANTAIRA FCU-1802Px User manual

ANTAIRA

ANTAIRA FCU-1802Px User manual

ANTAIRA Optolinx IMP-100A User manual

ANTAIRA

ANTAIRA Optolinx IMP-100A User manual

ANTAIRA FCU-1802P Series User manual

ANTAIRA

ANTAIRA FCU-1802P Series User manual

ANTAIRA STF-502C series User manual

ANTAIRA

ANTAIRA STF-502C series User manual

ANTAIRA IMP-C1000-SFP Series User manual

ANTAIRA

ANTAIRA IMP-C1000-SFP Series User manual

ANTAIRA FCU-280 Series User manual

ANTAIRA

ANTAIRA FCU-280 Series User manual

ANTAIRA FCN-3112 Series User manual

ANTAIRA

ANTAIRA FCN-3112 Series User manual

ANTAIRA LNP-101AG-T User manual

ANTAIRA

ANTAIRA LNP-101AG-T User manual

ANTAIRA BTS-1000A User manual

ANTAIRA

ANTAIRA BTS-1000A User manual

ANTAIRA Optolinx fcu-2805p User manual

ANTAIRA

ANTAIRA Optolinx fcu-2805p User manual

ANTAIRA IMP-C100 Series User manual

ANTAIRA

ANTAIRA IMP-C100 Series User manual

ANTAIRA STF-502C series User manual

ANTAIRA

ANTAIRA STF-502C series User manual

ANTAIRA FCU-100SX User manual

ANTAIRA

ANTAIRA FCU-100SX User manual

ANTAIRA EVC-3001 User manual

ANTAIRA

ANTAIRA EVC-3001 User manual

ANTAIRA BTS-1000A User manual

ANTAIRA

ANTAIRA BTS-1000A User manual

ANTAIRA IMC-C100 Series User manual

ANTAIRA

ANTAIRA IMC-C100 Series User manual

ANTAIRA IMC-1000A-SFP User manual

ANTAIRA

ANTAIRA IMC-1000A-SFP User manual

ANTAIRA FCU-2805P-SFP User manual

ANTAIRA

ANTAIRA FCU-2805P-SFP User manual

ANTAIRA FCM-2312WX User manual

ANTAIRA

ANTAIRA FCM-2312WX User manual

Popular Media Converter manuals by other brands

SoundTraxx Blunami BLU-2200 user guide

SoundTraxx

SoundTraxx Blunami BLU-2200 user guide

SPROLINK VA1 user manual

SPROLINK

SPROLINK VA1 user manual

Acclaim Lighting DDC-1-AC user guide

Acclaim Lighting

Acclaim Lighting DDC-1-AC user guide

Nikon AF-S TC-20E III user manual

Nikon

Nikon AF-S TC-20E III user manual

Axis AXIS Q7406 user manual

Axis

Axis AXIS Q7406 user manual

Omega TAC80B-J instruction sheet

Omega

Omega TAC80B-J instruction sheet

Zoom Thunderbolt TAC-2R Operation manual

Zoom

Zoom Thunderbolt TAC-2R Operation manual

OST iConverter 10/100M quick start guide

OST

OST iConverter 10/100M quick start guide

Vertiv Netsure user manual

Vertiv

Vertiv Netsure user manual

birddog MINI user guide

birddog

birddog MINI user guide

Roland GI-10 owner's manual

Roland

Roland GI-10 owner's manual

Wallenstein WX310 Operator's manual

Wallenstein

Wallenstein WX310 Operator's manual

Pace MSS 200-1 Service manual

Pace

Pace MSS 200-1 Service manual

Solar Converters EQ 12/24-50 manual

Solar Converters

Solar Converters EQ 12/24-50 manual

CYP EL-7400V Operation manual

CYP

CYP EL-7400V Operation manual

TIE MIDI 1i1o user manual

TIE

TIE MIDI 1i1o user manual

DCS Vivaldi Upsampler user manual

DCS

DCS Vivaldi Upsampler user manual

Westermo MCW-211 SERIES user guide

Westermo

Westermo MCW-211 SERIES user guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Antaira Technologies
IMC-C1000-XX Series
Compact Industrial Gigabit Ethernet Media Converter
10/100/1000Tx to 1000x with SC/ST Connector
Quick Installation Guide
Version 1.1
(Feb 2020)
Tel: 1-844-268-2472
Fax: 1-714-671-9944
www.antaira.com
Package Check List
The package contains the following items:
1 –Quick installation guide
1 –IMC-C1000-XX(-T)
1 –Wall mounting bracket set with screws
1 –DC cable –18 AWG & DC jack 5.5 x 2.1mm
Front Panel Layout
Top Panel View
IMC-C1000-XX series’top panel is equipped with one 4-pin
removal terminal block connector for dual DC power inputs
(12~48VDC).
Product Overview
System Interface/Performance
RJ45 port supports the auto MDI function
Embedded 1*10/100/1000Tx and 1*1000x
Store-and-forward switching architecture
Power Input & Connection
DC 12 to 48V redundant power with a 4-pin removal terminal
block
It is recommended to use a UL listed industrial power supply
Operating Temperature
Standard operating temperature model: -10°C to 70°C
Extended operating temperature model: -40°C to 80°C
Case/Installation
IP30 protection
DIN-Rail and wall mount design
LED Indicators
LED
Color
Description
PWR
Green
On
Power input 1 or 2 is active
Off
Power input 1 and 2 are inactive
LAN Port
(Upper LED)
Green
On
Connected to network at 1000Mbps
Flashing
Networking is active
Off
Not connected to network
LAN Port
(Lower LED)
Green
On
Connected to network at 10/100Mbps
Flashing
Networking is active
Off
Not connected to network
Fiber Port
Green
On
Connected to network at 1000Mbps
Flashing
Networking is active
Off
Not connected to network
DIP-Switch Setting
Illustration
DIP-Switch 1
DIP-Switch 2
Function Description
On
Off
LFP function Enable
Off
Off
LFP function Disable
Note: After any DIP switch changes have been made, it is
required to power cycle the unit for the changes to take effect.
Quick Installation
Ethernet Ports
RJ45 Ports (Auto MDI)
All RJ45 ports are auto-sensing for 10Base-T, 100Base-TX, or
1000Base-T(X) device connections. Please follow the wiring pin
assignment table below for Ethernet port installation.
Grounding Screw
4-Pin Removal Terminal Block (Power Input)
4-Pin Removal Terminal Block
(Power Input)
Fiber Port –1000x
Grounding Screw
LED for Power
DIP Switch for LFP Setting
LED for Link/Activity Status 10/100Mbps
LED for Link/Activity Status 1000Mbps
10/100/1000Tx RJ45 Port
LED for Fiber Link/Activity
Power Input Wiring
Please follow the steps below to insert the power wire:
1. Insert the positive and negative wires into the PWR1
(V1+, V1-) and PWR2 (V2+, V2-) contacts on the
terminal block connector as shown below in Figure 1.
2. Tighten the wire-clamp screws to prevent the wires from
loosening, as shown below in Figure 2.
Figure 1 Figure 2
Industrial Switch Mounting
DIN-Rail Mounting
The DIN-Rail bracket is pre-installed on the
industrial Ethernet switch from the factory.
Please refer to Figure 3 for a DIN-Rail
bracket installation reference.
Follow the steps below for installing the
industrial switch on the DIN-Rail track:
1. Insert the top of the DIN-Rail on to the
track as shown below in Figure 4.
2. Lightly pull down the bracket on to the
rail as shown below in Figure 5.
3. Check if the bracket is mounted tightly
on the rail.
4. To remove the industrial
Ethernet
switch
from the rail, do the opposite from the steps above.
Figure 4
Wall Mounting
Follow the steps below to mount the industrial Ethernet switch
using the wall mounting bracket as shown below in Figure 6.
1. Remove the DIN-Rail bracket from the industrial Ethernet
switch by loosening the screws.
2. Place the wall mounting brackets on the
top and bottom of the industrial Ethernet
switch.
3. Use the screws to screw the wall mounting
bracket onto the industrial Ethernet switch.
4. Use the hook holes at the corners of the
wall mounting bracket to hang the industrial
Ethernet switch on the wall.
5. To remove the wall mount bracket, do the
opposite from the steps above.
Field Maintenance and Service
If the device requires servicing of any kind, the user is
required to disconnect and remove it from its mounting. The
initial installation should be done in a way that makes this as
convenient as possible.
Voltage/power lines should be properly insulated as well as
other cables. Be careful when handling them so as to not trip
over.
Do not under any circumstance insert foreign objects of any
kind into the heat dissipation holes located in the different
faces of the device. This may not only harm the internal
layout, but might cause harm to user as well.
Do not under any circumstance open the device for any
reason. Please contact your dealer for any repair needed or
follow the instructions within the manual.
Warranty Policy
Warranty Conditions
Products supplied by Antaira Technologies are covered in this
warranty for sub-standard performance or defective
workmanship. The warranty is not, however, extended to goods
damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock,
earthquake
(c) Use of unqualified power supply, connectors, or
unauthorized parts/kits
(d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number
from Antaira before shipping the goods for repair or
replacement.
Within the warranty period (based on the invoice date), all
parts and labor are free of charge to the customers.
Customers are responsible for the cost of parts and labor if
the products are out of warranty.
For RMA service, customers are responsible for the shipping
expense for shipping the RMA unit(s) to Antaira. Antaira is
responsible for the shipping expense via a ground service
for the return repair/replace unit(s) back to customers.
Limited Liability
Antaira will not be held responsible for any consequential losses
from using Antaira’s product.
Warranty Period
5-Year Warranty
Antaira’s Customer Service and Support
Antaira’s Technical Service & Support Centers:
+ 844-268-2472 (Antaira US Headquarter)
+ 48-22-862-88-81 (Antaira Europe Office)
+ 886-2-2218-9733 (Antaira Asia Office)
Antaira’s Web Sites & Repair/Support Emails:
www.antaira.com / [email protected]
www.antaira.eu / i[email protected]
www.antaira.com.tw / i[email protected]
*Any changes will be announced on the Antaira website.
Figure 3
Figure 6
Figure 5