manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AP&T
  6. •
  7. Power Supply
  8. •
  9. AP&T AP-AY450 Series Specification sheet

AP&T AP-AY450 Series Specification sheet

AP-AY450X/850X
Product Instruction Manual
Power frequency AC high voltage power supply
Shangh ai Anping Static Technology Co., Ltd.
Website : www.ap-static.com
Address : 3/F,Building 27,No.69,Guiqing Road,Shanghai,China
Tel : +86-21-64517676
Fax : +86-21-64517673
1. With energy storage components to ensure stable output power.
2. The fan can dissipate heat and ozone in real time to extend the service life of the power supply.
3. Work under high voltage and low current.
4. Multiple high-voltage output ports which can carry multiple eliminators simultaneously.
5. Pluggable interface which is easy to operate and install.
Dimensions
Model AP-AY4507/8507 AP-AY4505/8505
Input voltage AC220V/50Hz Or AC110V/60Hz
Output voltage AC7000V(No load)AC5600V(No load)
Power < 20W/40W
Power status
indication
Green light on——normal work
Green light off——abnormal work
- 10℃—+ 50℃
<75%RH
Net weight 4250g 7450g
Dimensions
L*W*H
AP-AY450X:140*240*170
AP-AY850X:140*240*300
170
240
140 Ground stud
High voltage output
Power-on
indicator
Fan
Three-in-one power switch
300
240
140
Three-in-one power switch
Fan
Power-on
indicator
Ground stud
High
voltage
output
AP-AY450X structure size diagram
AP-AY850X structure size diagram
Product Features
Product Description
Specifications
AP-AY450X/850X power frequency AC high voltage power supply is one of the high-voltage power supply series products for electrostatic
eliminator produced by Anping Company (AP&T) which is designed for controlling the static electricity on the surface of the target to achieve the
purpose of electrostatic safety protection for the discharged object. It is a power frequency AC high-voltage power supply with multiple high-voltage
output ports which is a dedicated configuration power supply for Anping's AC ion bar products.
Working temperature
Working humidity
1. Insert the national standard power cord plug into the mains socket.
2. Insert the high-voltage connector of the static elimination device into the high-voltage output socket of the power supply and connect its
ground terminal to the ground stud of the high-voltage power supply.
3. The switch indicator and status indicator light on(Green light on when working normally) indicates the power supply working normally when
turn on the power switch.
4. The panel description is shown in the following figure:
AP-AY450X Panel description diagram
AP-AY850X Panel description diagram
Installation Guide
Power-on indicator
Ground stud
Ground stud Ground stud
Ground stud
High voltage output
Ground stud
Ground stud
Ground stud
Ground stud
Ground stud
Ground stud
High voltage output
High voltage output
Power-on indicator
Three-in-one power switch
Three-in-one power switch
Ground stud
Ground stud
Ground stud
Ground stud
High voltage output
NO.
1
2
No power supply from power supply or high voltage transformer
6KRUWFLUFXLWRISRZHUVXSSO\FDXVHGE\GDPDJHofKLJKYROWDJH
WUDQVIRUPHUfuse burnt out
3
Maintenance
It should be stopped and repaired by professional maintenance personnel when the red switch work indicator on the back panel of the high voltage
power supply is off, or the status indicator on the front panel is red or off, or the display is abnormal. It can be used only after the electrical
performance indicators are normal.
Problems Reasons Solutions
The switch indicator on the
back panel is off
Poor contact of the power cable Check whether the power cable is in good condition and
securely connected
No power supply Check the on-site power supply lines
The status indicator on the
front panel is off
The product is smoky or burnt
Return to factory for maintenance
Return to factory for maintenance
Return to factory for maintenance
The high-voltage transformer or high-voltage components or the
insulation of the KLJKvoltage output socket is damaged
Safety warning Warning
1. Please read the instruction manual carefully before installing and using this equipment.
2. The working input power of the power box must be reliably connected to the grounding wire of the electrical power supply cable and the
grounding resistance should be less than 4 ohm; Otherwise, it is easy to cause abnormal or even damage of ion bar and high voltage power supply.
3. Do not use this equipment in environment where humidity is > 70%.
4. It is strictly forbidden to use this equipment in flammable and explosive environments.
5. Unauthorized disassembly of the product is strictly prohibited, internal maintenance and repair must be performed by professionals.
6. It is strictly forbidden to touch liquid during use, otherwise an abnormality may occur and cause electric shock or fire.
7. Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.
8. The product is specially designed for eliminating static electricity. It is strictly forbidden to use it for other purposes. Any abnormal use may cause
machine failure, electric shock, fire and other accidents.
9. Please check the input voltage before powering on the product. Any power supply that does not meet the specifications will cause damage to the
product.
10.Please check the product power cord regularly and replace it immediately if it is damaged. Otherwise it is easy to cause problems such as electric
leakage and abnormal operation.
After-sales service
Packaging accessories
1. High voltage power supply has undergone rigorous testing and aging treatment before ex-work. Its performance has completely reached the
relevant indicators marked in the usage instruction.
2. AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge within one
year from the date of purchase. However, this commitment does not apply to:
a. The device is incorrectly used or installed.
b. Damage caused by negligence or accident during use.
c. Modified, disassembled or repaired by other service departments not authorized by Anping Company.
3. AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.
1、Manual
2、Certificate of conformity
3、National standard power cord
4、Mounting brackets

This manual suits for next models

5

Other AP&T Power Supply manuals

AP&T AP-AY1504 User manual

AP&T

AP&T AP-AY1504 User manual

AP&T AP-AY1505 User manual

AP&T

AP&T AP-AY1505 User manual

AP&T AP-AB1216 User manual

AP&T

AP&T AP-AB1216 User manual

AP&T AP-AC2455 Series User manual

AP&T

AP&T AP-AC2455 Series User manual

AP&T AP-AY1502 User manual

AP&T

AP&T AP-AY1502 User manual

AP&T AP-AB1208 User manual

AP&T

AP&T AP-AB1208 User manual

AP&T AP-DY7221 Specification sheet

AP&T

AP&T AP-DY7221 Specification sheet

AP&T AP-AY151X Specification sheet

AP&T

AP&T AP-AY151X Specification sheet

AP&T AP-AB1208 User manual

AP&T

AP&T AP-AB1208 User manual

AP&T AP-AY1506 User manual

AP&T

AP&T AP-AY1506 User manual

AP&T AP-AB1602A User manual

AP&T

AP&T AP-AB1602A User manual

AP&T AP-DC7201 User manual

AP&T

AP&T AP-DC7201 User manual

AP&T AP-AY1503 User manual

AP&T

AP&T AP-AY1503 User manual

AP&T AP-DY6702 User manual

AP&T

AP&T AP-DY6702 User manual

AP&T AP-AB1216 User manual

AP&T

AP&T AP-AB1216 User manual

Popular Power Supply manuals by other brands

Preen AFV-P Series user manual

Preen

Preen AFV-P Series user manual

FOSSIBOT F800 user manual

FOSSIBOT

FOSSIBOT F800 user manual

Cobalt Digital Inc 8310(-C) user manual

Cobalt Digital Inc

Cobalt Digital Inc 8310(-C) user manual

Pulsar GREEN POWER HPSB 2512B Instruction

Pulsar

Pulsar GREEN POWER HPSB 2512B Instruction

Advanced Energy Pinnacle Plus+ user manual

Advanced Energy

Advanced Energy Pinnacle Plus+ user manual

TAKASAGO HX-S-G2 Series instruction manual

TAKASAGO

TAKASAGO HX-S-G2 Series instruction manual

TDK-Lambda ZWX Series manual

TDK-Lambda

TDK-Lambda ZWX Series manual

LiteOn PF-2223-1 user guide

LiteOn

LiteOn PF-2223-1 user guide

BASE Electronics XP10 quick start guide

BASE Electronics

BASE Electronics XP10 quick start guide

SamplexPower SAM Series owner's manual

SamplexPower

SamplexPower SAM Series owner's manual

Pro-Ject Audio Systems Power Box II Instructions for use

Pro-Ject Audio Systems

Pro-Ject Audio Systems Power Box II Instructions for use

PowerBridge cPCIS-6235R Series user guide

PowerBridge

PowerBridge cPCIS-6235R Series user guide

Puls QT40.241 installation manual

Puls

Puls QT40.241 installation manual

Conrad 752227 operating instructions

Conrad

Conrad 752227 operating instructions

Akyga AK-TB-16 user manual

Akyga

Akyga AK-TB-16 user manual

gefran SM32 instruction manual

gefran

gefran SM32 instruction manual

NewMar PM-12-40A PM Series Installation and operation manual

NewMar

NewMar PM-12-40A PM Series Installation and operation manual

TDK-Lambda GENESYS GH1.5kW in 1U Half-Rack 0-600V /... manual

TDK-Lambda

TDK-Lambda GENESYS GH1.5kW in 1U Half-Rack 0-600V /... manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.