Glossary
Term Denition
Accuracy See Measurement Uncertainty.
ADC Analog-to-digital converter.
Calibration The act of measuring a transducer’s raw response to loads and
creating data used in converting the response to forces and torques.
Calibration Certicate
A statement that says the equipment measures correctly. These
statements mean the equipment has been tested against national
standards. The statements are produced as a result of calibration or
re-calibration.
CoE CANopen over EtherCAT is the preferred embedded protocol for
conguring EtherCAT devices. Used within SDO to encode the
conguration data.
Compound Loading Any load that is not purely in one axis.
Coordinate Frame See point of origin.
DINT A 32-bit data type representing a signed integer.
DoF Degrees of freedom. See six degrees of freedom.
EtherCAT An industrial automation eldbus.
FoE File access over EtherCAT, the preferred embedded protocol for
uploading new rmware to EtherCAT devices.
Force The push or pull exerted on an object.
FS Full-Scale.
F/T Force/Torque.
F/T Transducer The device that converts force and torque into an electrical signal.
Fxy The resultant force vector comprised of components Fx and Fy.
Full-Scale Error
A measurement of sensing error. For example, if the calibrated
measurement range of a sensor is 100 Newtons and the sensor is
accurate to within 1 Newton, that sensor will have a Full-Scale Error of
1% (1% = 0.01 = 1 N / 100 N).
Hysteresis A source of measurement error caused by the residual effects of
previously applied loads.
IP60 Ingress protection rating “60” designates protection against dust.
ISR Interrupt service routine.
MAP The Mounting Adapter Plate (MAP) is the transducer plate that attaches
to the xed surface or robot arm.
MAX. Single-Axis Overload The largest amount of load in a single axis (all other axes are unloaded)
that the transducer can withstand without damage.
Measurement Uncertainty The maximum expected error in measurements, as specied on the
calibration certicate.
Moment An object that receives a torque has a moment applied to that object.
Offset Compensation Correction of errors that change the zero point of a transducer’s
readings.
Overload The condition where more load is applied to the transducer. This will
result in saturation.
PDO Process Data Object, a protocol for reading and writing real-time
process information cyclically.