AURATON 2100 TX User manual

AURATON 2100 TX
Advanced Remote Control
Programmable Thermostat
ARATON 2100 TX 1

I. INTRODUCTION
This thermostat can replace most common
residential thermostat and is designed to be used
with electric, gas or oil heating control system or
cooling system.
Unlike those ordinary single unit design thermostat,
AURATON 2100 TX is a new type of thermostat
separating the thermostat function into two units.
The Receiver serves for wiring connections and
heat/cool on/off control. The Control Center serves
as user interface and temperature sensing /
control. The two units are linked by RF.
The advantage is that user can put the Control
Center nearby and can read / control the
temperature of really the living area.
1.1) Outlook of Control Center
1. Conf/Econ button
2. Up button
3. Set Time button
4. Reset button
5. Down button
6. Back-light button
7. Set temperature button
8. Set program button
2ARATON 2100 TX
1
2
3
4
5
6
8
7

1.2) LCD
1. Heat / Cooler on icon
2. Comf. icon
3. Econ. icon
4. Program number
5. Manual Override Icon
6. Day Indicator
7. Clock
8. Anti-freezing icon
9. Battery low icon
10. Temperature
11. Control profile bar
ARATON 2100 TX 3
1
2
3
4
5
7
6
8
9
10
11

1.3) Outlook of Receiver
1.4) Features
Several useful function and operating modes have
been incorporated to adapt a variety of customer
needs besides all the features associated with the
state of the art programmable thermostat.
1.5) Control Center
- Can be placed at user living area to detect and
control the temperature of the area where user
really take activates. Not limited by power control
wiring locations.
4ARATON 2100 TX
LED Indicators
Front View
Front Cover
Power switch
Connect to
Heating /Cooling
Device
Connect to Live
Connect to
Neutral

- Link with the Receiver via RF. Control distance
100M open site
- LCD shows the "need to know" information only,
which is more easy to understand
- Real time clock with day of the week display
- Room temperature display
- Control profile display
- Simplified temperature adjustment
- Simplified programming procedure
- 6 pre-defined control profiles, 3 user
programmable control profile
- A protection against freezing
- Temporary override set-temperature
- User selectable temperature span
- User selectable heater/cooler operation mode
- Battery level detection
- 2 AA size alkaline batteries (not included)
- Slim housing design
- EL backlight
1.6) Receiver
- Linked with Control Center via RF
- Power control rating up to 230VAC 16A resistive
- Powered by line voltage only. No battery required
- Two LED indicators for power and output status
ARATON 2100 TX 5

II. INSTALLATION OF RECEIVER
Caution:
1. The appliance can only be mounted on dry indoor
places
2. A suitable fuse with a rating not exceeding 20A,
should be in the power line
3. Observe the nation regulator for the wiring
4. Qualified electrician is recommended for
installation and servicing
This thermostat has been designed for simple and
quick installation requiring only a few tools. Only
the Power Control Unit need to be installed.
2.1) Required Material
Hammer
Masking tape
Screwdriver
Drill and 3/16" drill bit (if not installed on a junction
box)
2.2) RF Address Code Setting
If there is another user nearby, e.g. in the next
house, installs the same AURATON 2100 TX unit,
your receiver may be fault triggered by his/her
transmitter. You may select a different RF address
code to prevent this. Receiver can only response to
RF coding with the same address code setting as its
own address code.
1. To adjust address code of Receiver, simply push
up one or more of the 5 dip switch levers
2. To adjust address code of Control Center, open
the housing of transmitter unit. See battery
replacement section on how to open the
housing
6ARATON 2100 TX

3. Remove one or more of the jumper cap as
shown in the diagram below.
Caution :
1. Address code of Control Center must be the
same as address code of Receiver. For any
jumper cap removal of address code # in Control
Center, same address code # of Receiver must
be put to the UP position.
2. Disconnect AC power and remove batteries
before adjusting address code.
Remove one or more of
the jumper cap to adjust
RF address code.
Address code # 1 - 5,
from left to right
ARATON 2100 TX 7
DIP
12345
ON
Push up one or more of the
white levers to adjust
Receiver address code.
Address code # 1 - 5, from
left to right.

2.3) Removing your old thermostat
CAUTION: to avoid electric shock, turn off the
power of the heating/cooling system at the main
power box in your home. Read the following
instructions carefully before disconnecting the
wires.
1. Turn off your old thermostat.
2. Remove the cover from the old thermostat
You may have to pull extra hard.
3. Unscrew the old thermostat from the wall plate.
4. Now find the screws attaching the wall plate to
the wall, and remove them. You should now be
able to pull the wall plate a small distance from
the wall. Do not disconnect any wire yet,simply
locate the wires.
WARNING:
After removing the wall plate, if you find
that it is mounted on a junction box (e.g. a box
similar to one behind a light switch or electric
outlet), high voltage circuit may be present and
there is a danger of electric shock. Please consult a
qualified electrician.
2.4) Wire Labeling
1. Disconnect and identify each wire.
2. You may wish to tape the wires to the wall to
keep them from slipping through the hole in the
wall. If the hole in the wall is larger than
necessary, fill it in order to prevent hot or cold
air to penetrate the thermostat. In this manner,
the thermostat will behave perfectly.
8ARATON 2100 TX

Choosing a Location
Note: for a new installation, choose a mounting
location about five feet (1.5 meter) above the floor
in an area with good air circulation and away from.
1. Drafts of dead air sports.
2. Air ducts.
3. Radiant heat from the sun or appliances.
4. Concealed pipes and chimneys.
2.5) Mounting the Receiver onto the
wall/junction box:
1. Remove the front cover of the Receiver. (jump to
step 4 if installed on a junction box).
2. Mark the holes position.
3. Drill two holes and insert the plastic anchors
carefully into the holes until they are flush with
the wall.
4. Connect the wires.
5. Push on the wires in the wall.
6. Fasten securely the Receiver to the wall with the
two screws.
7. Cover up the unit with the front cover and
installation is completed.
2.6) Mounting the Receiver onto the optional
wall box :
1. Remove the front cover of the Receiver.
2. Mark the holes position for the wall box.
3. Drill two holes and insert the plastic anchors
carefully into the holes until they are flush with
the wall.
4. Pull the wires into the wall box and fasten the
wall box onto the wall.
5. Connect the wires.
6. Push on the wires in the wall box.
7. Fasten securely the Receiver to the wall box with
the two screws.
8. Cover up the unit with the front cover and
installation is completed.
ARATON 2100 TX 9

2.7) Wiring Diagram
The AURATON 2100 TX thermostat can be used with
any single stage heating or cooling system.
Wire connection is as follows :
III. SETTING OF CONTROL CENTER
3.1) Heater/Cooler Selection
Before making any selection in the control center,
its back housing must be removed as follows:
10 ARATON 2100 TX
Neutral
Output
Input Remove
the front
housing
Push and hold
internal lock by
a screw driver

Inside the Control Center after back housing is
removed, you can find the DIP switch. These three
switches are used to control the span and heat/cool
system. Set the DIP switch (position 3) according
to your selection of heater system or cooler system
as the following diagram.
Set the DIP switch (position 3)
3.2) Temperature Span Selection
Span is the temperature difference between the
turn on temperature and turn off temperature. For
example, in heating system, if you set temperature
to 20°C and span to 1°C, the heater will operate
when the room temperature drops to 19.5°C and
turns off when the temperature rises to 20.5°C. Set
the DIP switch (position 1 & 2) according to your
selection of temperature span as the following
diagram.
ARATON 2100 TX 11
On: Heater
Off: Cooler
1 2
ON
SPAN
1°C
2°C
3°C
4°C
ONON
112233
ON
ON
ON
OFF
OFF
OFF
OFF

3.3) Battery Installation
Your thermostat is using two (2)
"AA" size batteries to operate.
To power-up the unit, insert two
"AA" batteries into the battery
compartment of the front housing.
When power is applied for the first
time, the display must show time
and the day as well as the room
temperature (for example 28.5°C).
If the display is different, press the
RESET button. Use a fine probe such
as straightened paper clip to gently
push the RESET button.
After installation of the batteries,
put back the back housing to the
control center and then the stand.
Before turning on the main switch
of the system, press the reset button
once .The thermostat is ready for use.
3.4) Setting Clock
1. Press the button to clear all digits except the
day indicator and the time display. The Day
indicator is flashing.
2. While Day indicator is flashing, press or
button to adjust.
3. Press the button again, hour digits are
flashing instead of day indicator. Press or
button to adjust. Press and hold the or
button will speed up the adjustment rate.
4. Press the button again, minute digits are
flashing instead of hour digit. Press or
button to adjust. Press and hold the or
button will speed up the adjustment rate.
5. Press the button again to return to normal
operation mode.
6. The unit will return to normal operation mode if
no key is pressed for 10 seconds.
12 ARATON 2100 TX

3.5) Setting Control Temperature
1. Press the SET TEMPERATURE ( ) button to
display the pre-defined set temperature.
2. Press the CONF/ECON ( ) button to toggle
between the setting of economic mode and
comfortable mode.
3. Press the or button to increase / decrease
the set temperature by 0.5°C.
4. Press the button again to save the set
temperature.
5. The unit will back to normal operation mode if no
button is pressed for 10 seconds.
6. The default setting of comfortable mode is 21°C
for heater mode and 23°C for cooler mode. And
the economic mode is 18°C for heater mode and
26°C for cooler mode.
ARATON 2100 TX 13

14 ARATON 2100 TX
3.6) Setting Program
I - Select Week-Day
1. Press the SET PROGRAM ( ) button, the day
indicator shows the program day and is
flashing. Program number indicator shows the
current program for the selected day.
2. Press the or button to select the day
needed to program. You can select the whole
week, working day, weekend,or individual day
to program.
II - Select Control Profile - Pre-defined
1. Press the SET PROGRAM ( ) button again,
the day indicator stop flashing and the
program number starts flash.
2. Press the or button to select the program
profile. P1-P6 are predefined program, their
profile are shown as follows.
00 06 12 18 24
00 06 12 18 24
00 06 12 18 24
00 06 12 18 24
Program number Program profile
00 06 12 18 24
00 06 12 18 24
Program 1:
Factory preset
"Whole day comfort"
Program 2:
Factory preset
"Whole day econ"
Program 3:
Factory preset
"Holiday"
Program 4:
Factory preset
"Whole day (A)"
Program 5:
Factory preset
"Whole day (B)"
Program 6:
Factory preset
"Half"-day work"

ARATON 2100 TX 15
3. If any of these programs is selected, press the
SET PROGRAM ( ) button again to confirm this
program for the specified day and back to
normal operation mode.
4. Press the button will toggle the control
temperature setting and advance the setting
hour digit by one.
Example:
button is pressed. Hour Digit (Clock)is 2
and the 02 hour bar is flashing. icon is on
and the operation mode for hour 01 is set to
economic mode.
5. Press the button will terminate the setting
procedure and back to normal operation mode.
Example:
button is pressed. Terminate the setting
procedure and the new control profile is :
6. The setting procedure will terminate
automatically when no button is pressed for 10
seconds.

16 ARATON 2100 TX
IV. TESTING THE RF TRANSMISSION
RANGE
1. Press UP ( ) button until the setpoint
temperature is higher than room temperature by
a few degree.
2. Wait for a few seconds.
3. Check the green LED. It should be On.
4. If the LED is not On, try to locate the Control
Center closer to the Receiver. Press DOWN ( )
button to adjust the setpoint temperature to be
lower than room temperature to "turn of" the
receiver.
5. Repeat steps 1 to 3.
6. The receiving range between Control Center and
Receiver is 100M in open area. When placed
indoor, this distance may be shorter because of
blocking by concrete wall etc, but is enough for
most household application.
7. Press RESET button after receiving range testing.
V. TEMPORARY OVERRIDE
5.1) Override the Operation Mode
At the normal operation mode, press the
CONF/ECON ( ) button will toggle the current
set temperature to comfortable mode or economic
mode. If the operation mode is being override, the
HAND ( ) icon will be turned on with the current
operation mode icon.

5.2) Override the Setting Temperature
1. At the normal operation mode, the current set
temperature can be override by pressing the
or button. When override, the new set
temperature will be displayed with turning on the
HAND ( ) icon and off both the CONF ( )
and ECON ( ) icon.
2. Press other button (except the or button)
will terminate the setting procedure and back to
normal mode with the new setting.
3. The unit will back to normal operation mode
automatically when no button is pressed for 10
seconds.
VI. ANIT-FREEZING MODE
1. Pressing the and buttons simultaneously
will activate the anti-freezing mode (for heater
mode only). The ANTI-FREEZING ( ) icon and
the icon will be turned on while both the
and icon will be turned off.
2. Pressing any button will terminate the anti-
freezing mode and back to normal operation
mode.
3. The default set temperature for the anti-freezing
mode is 7°C
ARATON 2100 TX 17

VII. BACK- LIGHT
Press the BACK-LIGHT ( ) button will turn on
the backlight. The back-light will be off when no
button is pressed for 10 seconds.
VIII. BATTERY REPLACEMENT
It is recommended to replace the batteries when
the display is showing the battery-low icon. To
replace the battery,
1. Turn off the power of the Receiver first.
2. Remove the back housing and stand of the
Control Center.
3. Replace the old batteries with 2 new AA alkaline
batteries.
4. Replace the back housing and stand.
5. Press the reset button once and then turn on the
power switch of the Receiver.
IX. POWER SWITCH
There is a power switch on the Receiver. When
there is no demand to turn on the heating / cooling
device, e.g. when you go out for long vacation, it is
recommended to turn the power switch at Off
position.
X. LED INDICATOR
There are Two LED on Power Control Unit as status
indicator :
1. Red LED turns on as long as 230VAC power is
turned on. When there is no power to the unit or
when power switch underneath the front cover is
put at Off position, the red LED is Off.
2. Green LED turns on as long as the heating /
cooling device is energized.
18 ARATON 2100 TX

XI. SPECIFICATION
Physical Characteristic
Size:
Control Center 116 x 100 x 23.5 mm
Receiver 91.5 x 91.5 x 42 mm
Weight:
Control Center 126g
Receiver 176g (include wall Box)
Electrical Characteristic
Power Source:
Control Center 2 AA (LR6) batteries
Receiver 230VAC 50Hz
Switching cap:
16A for resistive load
8A for inductive load
Clock accuracy:
+/- 60 seconds/month
Temp. measurement:
0°C to 40°C in 0.5°C resolution
ARATON 2100 TX 19
Temp. accuracy:
+/- 1°C at 20°C
Temperature Control:
7°C to 30°C in step of 0.5°C
Span:
1,2,3 or 4°C
Air conditioner cycle time:
3 minutes
Operation temperature:
0°C to 40°C
Storage temperature:
-10°C to 60°C
Table of contents
Other AURATON Thermostat manuals

AURATON
AURATON Libra User manual

AURATON
AURATON 200 RTH User manual

AURATON
AURATON Libra User manual

AURATON
AURATON 2005 User manual

AURATON
AURATON R30 RT User manual

AURATON
AURATON S03 RTH User manual

AURATON
AURATON Auriga User manual

AURATON
AURATON T-1 RT User manual

AURATON
AURATON 1300 User manual

AURATON
AURATON 2005 TX User manual