AURATON 2005 User manual

2005 TX RX Plus
2005
user manual en

I
0
AURATON 2005
AURATON
2005 TX Plus
Communication code of AURATON 2005 TX Plus
can be manually set by user.
The factory set communication code is "085".
If there are troubles with communication between
AURATON 2005 TX Plus and RX Plus the code can
be changed (Manual, page 41).
AURATON
2005 RX Plus
29 EN

1. Installation instructions
AURATON 2005
Caution: Switch off the electric source before
installing the thermostat. We recommend that the
installation should be performed by a trained
personnel.
1.1 Select a suitable location for the AURATON
2005.
The location of the thermostat can greatly affect its
performance. If it is located at where circulate air
cannot reach, or exposed to direct sun light, it will
not adjust the room temperature properly.
To ensure proper operation, the thermostat should
be installed at an inside wall with freely circulating
air. Find a place where your family usually
occupied.
.
Avoid close to some heat generating appliance (e.g.
TV, heater, refrigerator) or exposed to direct sun
light. Do not install near a door where the
thermostat will suffer from vibration.
150cm
właściwe usytuowanie sterownika
PROPERLY INSTALLED THERMOSTAT
AURATON 2005
AURATON 2005 - Installation 30
EN

1.2 Wiring AURATON 2005
Wiring terminals are at the back of the thermostat.
Press down the terminal cover, you can find three
terminals which labelled COM, NO and NC. It is a
typical single-pole, double throw (SPDT) contact. In
most COM and NO are used.
1.3 Mounting the thermostat AURATON 2005
Use the template provided, drill two Ø6mm holes on
the wall. Insert the wall anchors and tighten the left
screw with 3mm clearance.
NO
COM
NC
NO
COM
NC
Fix the thermostat by putting it over the screwhead
and slide it rightward (note the keyhole like opening
at the back of the thermostat). Tighten the remain
screw to lock it in place.
Note:
If the wall is made of wood, there is no need to use the
wall anchors. Drill two Ø2.7mm holes instead of
Ø6mm.
AURATON 2005 - Installation
31 EN

2. Familiar with your
AURATON 2005
AURATON 2005 TX Plus
2.1 Appearance
There is a sliding front cover at the right of the
thermostat. If you open the cover, you can see
some buttons. This cover is removable for the
replacement of batteries. To rise up the sliding
cover, you can see the dip switch.
PROG
0612 18 24
0
c
dnm
Temp.
Prog.
Prog.#
OK Reset
-
-
+
+
ON
123
AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON 32
2.2 Temperature mode
You can see "A" and "B" on both the buttons
and the LCD. "A" indicates comfort temperature
and "B" indicates economy temperature. These two
temperatures are user changeable. Furthermore,
O
there is a fixed defrost temperature (7 C) indicated
by "d" on the LCD. Throughout the operation of
the thermostat we will refer them as comfort,
economy or defrost temperature instead of numeric
values.
2.3 Dip switches
ON
123
DELAY 5 MIN.
COOLING
HEATING
NO DELAY
O
SPAN TEMP = 1 C
SPAN TEMP
O
= 0,5 C
EN

If you remove the front cover, you can find three
small switches (dip switches). These three switches
are used to control the span, output-on delay and
O
heat/cool system. Span is the temperature (1 C or
O
0,5 C) difference between the turn on temperature
and turn off temperature.
2.4 Program
AURATON 2005 or AURATON 2005 TX Plus is a
programmable thermostat. It can automatically
adjust the room temperature to a comfortable level
when you are at home, and lower it to save energy
when you go out or sleep. What you have to do is
to program the thermostat so that it knows when to
raise the temperature. There are altogether nine
programs contained in the memory of the
thermostat. Six of them are preset in the factory and
the remaining three are user changeable.
2.5 LCD
1 - Day of the week Indicator
2 - Time
3 - Temperature
4 - Program Number
5 - Program Profile Indicator
6 - Manual Override Indicator
7 - Output-On Indicator and temperature Mode
Indicator
8 - Low Battery Indicator
0
c
PROG
0612 18 24
1
2
8
5
4
6
7
3
AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON
33 EN

Note:
A. The output-on indicator will be displayed if the
output is on. It will disappear if the output is off.
B. The low battery indicator will be displayed if the
voltage of the batteries drop to a certain level.
Please change the batteries as soon as
possible.
2.6 Start
The thermostat is operated by two LR6 alkaline
batteries. Please remove the front cover and install
two new batteries. When the batteries are installed,
the thermostat should be operating and you can
see the LCD active. If the thermostat does not work
properly, please check the batteries for wrong
polarities and press the reset button by a ball-point
pen.
The LCD after start or reset.
Note:
O
A. Temperature may not be 22.25 C as the
diagram shown and the Output-On indicator
may active after a few seconds, depend on
different situations.
B. Do not use a pencil to push the reset button.
The graphite residue of a pencil can cause
short circuit and damage the thermostat.
34
AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON
0
c
PROG
0612 18 24
..
EN

2.7 Set day/time
To set day, press "d" button. Similarly, press "h"
button to set hour and "m" button to set minute.
Example: When start or after reset, the time is
00:00, Sunday. To set the clock to current time (e.g.,
11:23, Tuesday), press "d" 2 times, "h" 11 times and
"m" 23 times.
Note: When you press and hold the keys for 2
seconds the day/time will change rapidly. Release
when the desired setting comes.
2.8 View/Change temperature
Press Temp, the thermostat enter View/Change
temperature mode. The LCD will show the setting of
the current temperature mode ( A, B or d ) which
will be flashing. Press button "A" or "B" button to
review or change the temperature. Press OK will
directly return to normal operation mode.
Note:
O
A. The temperature setting range is 5 to 30 C.
B. To lower the setting, enter View/Change
temperature mode and press "A" or "B" until it
O
reaches 30 C and then the setting will return to
O
5 C. Continue to press until the desired setting
comes.
C. Press and hold the keys, the setting will change
rapidly.
D. Please note the temperature mode indicator. A
"A" means the comfort temperature is being
viewed or changed.
A "B" indicates economy temperature. If "d" is
shown, it is defrost temperature. Defrost
O
temperature is always at 7 C and is not
changeable.
E. It is not always necessary to use OK key to
return to normal operation mode. After 15
seconds of no key pressed it will automatically
return to normal mode.
AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON
35 EN

2.9 View/Change programs
Press "Prog" button, the program of the current day
is ready to be changed.
Press "Prog" button again can advance to the next
day and the program of that day will be shown.
Press "Prog#" button to change the program.
Programs 6, 7 and 8 are user-define programs. You
can use "A" or "B" to change the distribution of
comfort or economy temperature and h to review
the setting. Press OK can return to normal
operation mode.
There are altogether nine programs available, as
the diagram shown: Program 0 is a special program. It will set the whole
O
day to defrost temperature (7 C). (If cooling mode is
selected, it will turn off the system). Programs 1,2,
and 3 are some typical schedule of a day. You can
select them if you found them suitable. Program 4
set the whole day to comfort temperature while
program 5 set it to economy. Programs 6, 7 and 8
are user-define programs. They can be modified to
suit your need.
36
0612 18 24
0612 18 24
0612 18 24
PROG
PROG
PROG
AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON
0612 18 24
0612 18 24
0612 18 24
0612 18 24
0612 18 24
PROG
PROG
PROG
PROG
PROG
PROG
0612 18 24
EN

Example:
A. Assume you want to assign program 6 to
Saturday and want to set the whole day to
economy temperature except 13:00 to 18:00.
Press "Prog". The thermostat enters program
mode and the program of the current day (e.g.,
Tuesday) is ready to be programmed. The
display shows the program for Tuesday is
program 1, the temperature for 00:00 is
O
economy temperature and is 15 C. (The
flashing cursor is the time to be edited)
B. Press "Prog" 4 times. The day indicator will
point to Saturday:
C. Press "Prog#" 5 times to change the program
from program 1 to program 6
D. Now you can set the time shown to economy
temperature by pressing "B" or press "A" to set
it to comfort temperature. Or you can use "h"
key to pass through the time without changing
the setting.
Since we want to set 13:00 to 18:00 to comfort
temperature and the remains to economy
temperature, press 13 times. 00:00 to 12:00 will
be programmed to economy temperature
Press "h" or "A" 6 times to move the flashing
point to 19:00:
E. Finally, press "B" 5 times to set the remains of
the day to economy temperature:
0
c
0612 18 24
..
0612 18 24
..
AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON
37 EN

F. Press OK or leaving no key pressed for 15
seconds, the thermostat will return to normal
operation mod.
Note: Programs 0, 1, 2, 3, 4, 5 are preset
programs. "A" and "B" cannot be used to edit them.
But "h" key is still active.
2.10 Manual Override
Method no. 1:
Press "A" to select comfort temperature. Press "B"
to select economy temperature. The current
temperature mode will be overrode until the next set
point of the program comes. Press OK to clear
override.
Method no. 2:
Press "A" or "B" and hold for 2 seconds. "01" will
apear on the LCD. It means that manual override
will be forced for one hour. The number of hours
(from 1 to 24) can be set by pressing/holding the
button.
PROG
0612 18 24
0
c
Ni Po Wt Śr Cz Pt So
heating device
AURATON
2005 RX Plus
AURATON
2005 TX Plus
reciver radio signal temperature controller
transmitter
AURATON 2005 TX RX Plus - Installation 38
3. Installation instructions
AURATON 2005 TX RX Plus
Programmable Temperature Controller AURATON
2005 TX Plus is almost the same product as
AURATON 2005. The only difference is way of
transmitting on/off signal. AURATON 2005 TX Plus
uses radio waves. That eliminates wires between
AURATON 2005 TX Plus and controlled device.
Receiver of radio waves is module called AURATON
2005 RX Plus. Range of AURATON 2005 TX Plus
is very high but depends on materials that house is
made of. AURATON 2005 TX Plus with AURATON
2005 RX Plus module is capable to hold range of
over 100mtrs outdoor and up to 30mtrs indoor.
EN

4. Appearance of
AURATON 2005 RX Plus
NC NO COM
front back
2
1
3
4
5
6
AURATON 2005 RX Plus - Appearance
3.1 Connecting AURATON 2005 RX Plus
to a heating device
Warning:
Unplug heating device from power supply before
mounting receiver.
Find connectors on the back of AURATON 2005 RX
Plus under the plastic cover.
In most cases connect heating device to NO and
COM connectors.
NO
COM
NC
NO
COM
NC
39 EN

5. Turning on AURATON 2005 TX RX
Plus for the first time
1. Insert new ALKALINE batteries in AURATON
2005 TX Plus
2. Plug in AURATON 2005 RX Plus and wait 10
minutes to achive full range by transmitter
3. Yellow LED indicates that transmitter is within
receivers range . LED blinks once a minute.
The transmitter is out of range (or batteries of
AURATON 2005 TX Plus are low) if LED blinks
every second or does not blink. The factory set
communication code is „085”. If there are
troubles with communication code can be
changed – see chapter no. 6.
4. Red LED indicates that receiver AURATON
2005 RX Plus is supplied with 230VAC.
5. Green LED indicates that heating device is on.
AURATON 2005 TX RX Plus - Turning on for the first time 40
1. Antenna for communication with AURATON
2005 TX Plus.
2. green LED – indicates operating status of
heating device
red LED – indicates power supply status of
AURATON 2005 RX Plus
yellow LED – indicates communication
status with AURATON 2005 TX Plus
3. Additional electric socket switch
4. Additional electric socket – can be used to
supply any 230VAC device (MAX.5A).
5. Plastic connectors cover
6. 230VAC plug
EN

AURATON 2005 TX RX Plus - Setting communication code
4. Press and hold "PROG#" again to set new
communication code (range between 001 to
255).
5. Plug in receiver AURATON 2005 RX Plus to
230VAC and press OK button on the transmitter
AURATON 2005 TX Plus (after 10 seconds
LCD will return to normal mode).
6. AURATON 2005 RX Plus will confirm
programming new code by blinking yellow diode
for 3 seconds.
7. Plastic holder for
Auraton 2005 TX plus
There is a plastic holder for AURATON 2005 TX
Plus in the box.
Notes:
If AURATON 2005 RX Plus will not receive ON/OFF
signal from AURATON 2005 TX Plus for 5 minutes
(cycles) the heating device will be turned off.
System will return to its normal operation after
interfere disapear. AURATON 2005 TX Plus sends
digital signals that is why many other devices can
work within its range without interfere.
6. Setting communication code
There is a factory set communication codet - „085”.
In case of interfere with other device (e.g. another
AURATON 2005 TX Plus) preset code can be
changed:
1. Unplug receiver AURATON 2005 RX Plus from
230VAC.
2. Slide transmitters AURATON 2005 TX Plus
cover.
3. Press and hold "PROG#" for 2 seconds,
communication code will be displayed on LCD
(factory set code is 085).
41 EN

8. How to connect AURATON 2005
8.1 How to connect AURATON 2005 directly to
a heating device.
AURATON 2005
AURATON 2005 - How to connect 42
NO
COM
NC
HEATING
DEVICE
EN

8.2 How to connect AURATON 2005 to single-
phase heating device with working load
exceeding 5A thought magnetoelectric
relay.
AURATON 2005
NO
COM
NC
POWER
SUPPLY
max ~220V
HEATING
DEVICE
MAGNETOELECTRIC
RELAY
AURATON 2005 - How to connect
43 EN

8.3 How to connect AURATON 2005 to three-
phase heating device through three-phase
contactor.
44
AURATON 2005
NO
COM
NC
THREE PHASE
CONNECTOR
max ~220V
RST
HEATING
DEVICE
AURATON 2005 - How to connect EN

8.4 How to connect AURATON 2005 directly to
gas water heating device powered by
~220V and equipped with circulating
pump.
NO
COM
NC
AURATON-2005
GAS
WATER
DEVICE
~220V
max ~220V 5A
CIRCULATING PUMP
AURATON 2005 - How to connect
45 EN

NO
COM
NC
1
PROG
0612 18 24
0
c
Ni Po Wt Śr Cz Pt So
2
HEATING
DEVICE
1. AURATON 2005 RX Plus (receiver)
2. AURATON 2005 TX Plus
AURATON 2005 TX RX Plus - How to connect 46
8.5 How to connect AURATON 2005 TX RX Plus
with a heating device
EN

9. Specification
1. Temperature measurement range
O O
0-34.75 C (0,25 C step)
2. Temperature control range
O O
5-30 C (0,25 C step)
3. Temperature accuracy
O
+/- 1 C
4. Clock accuracy
+/- 70 seconds/month
5. Program
6 preset, 3 user-define
6. Switching span
O O
0,5 C or 1 C
7. Control mode
Heating or Cooling system
8. Minimum air-con. cycle time
5 minutes
9. Switching
230VAC 50Hz 5A resistive
10. Dimensions
154 x 80 x 30 (mm) (W x H x D)
11. Operation temperature
O
0 - 45 C
12. Storage temperature
O
-20 - 60 C
13. Operating humidity
5 - 90% non-condensing
AURATON 2005, AURATON 2005 TX RX Plus - Specification
47 EN
This manual suits for next models
2
Table of contents
Other AURATON Thermostat manuals

AURATON
AURATON Tucana User manual

AURATON
AURATON R30 RT User manual

AURATON
AURATON Auriga User manual

AURATON
AURATON 1300 User manual

AURATON
AURATON Tucana User manual

AURATON
AURATON Libra User manual

AURATON
AURATON Libra User manual

AURATON
AURATON S03 RTH User manual

AURATON
AURATON 200 RTH User manual

AURATON
AURATON 2020 User manual