Total active energy(kWh)
Display format:0000.00
Import active energy(kWh)
Display format: 0000.00
Export active energy(kWh)
Display format: 0000.00
Voltage (V)
Current (A)
Active power (W)
Frequency (F)
Power factor (PF)
Modbus Address or Primary address
Default: 001Baudrate Default : 9600bps
Parity
Even/Odd/None are optional
Primary current 1A-9999A
Default: 5 (sample shows 100A)
CT 2
Secondary current 5A
Software version
1. Introduction
This document provides operating, maintenance and installation instructions
of A-45 series. The unit measures and displays the characteristics of single
phase two wires application. It provides voltage, current, power, frequency,
power factor and energy information. A-45 series has both direct connect types
and 5A CT operated types. The direct connect type can work with direct load
45A. Two Pulse outputs and 1 remote communication port is provided.
This series covers 3 models:
2.Specifications
2.1 General Specifications
Voltage AC (Un).........................
Voltage Range...........................
Current Input............................
Power consumption.................
Frequency.................................
AC voltage withstand...............
Impulse voltage withstand......
Overcurrent withstand............
Pulse output rate......................
Display........................................
Max reading...............................
230V
176~276V AC
0.25~5(6)A
<2W/10VA
50/60Hz (50Hz only for MID version)
4KV for 1 minute
6KV-1.2uS wavform
20Imax for 0.01s
1000imp/kWh (default)
100/10/1 imp/kWh/kVarh (configurable)
LCD with white backlit
999999 kWh
2.2 Accuracy
Voltage...................................
Current..................................
Frequency..............................
Power factor..........................
Active power..........................
Reactive power......................
Apparent power....................
Active energy.........................
.........................
Reactive energy.....................
0.5% of range maximum
0.5% of nominal
0.2% of mid-frequency
1% of Unity
1% of range maximum
1% of range maximum
1% of range maximum
Class 1 IEC62053-21
Class B EN50470-3 (MID product only)
1% of range maximum
2.3 Environment
Operating temperature...............................
Storage and transportation temperature.
Reference temperature...............................
Relative humidity..........................................
Altitude..........................................................
Warm up time...............................................
Mechanical Environment.............................
Electromagnetic environment....................
Degree of pollution......................................
-25°c to +55°c
-40°c to +70°c
23°c ±2°c
0 to 95%, non-condensing
up to 2000m
3s
M1
E2
2
2.4 Mechanics
Din rail dimensions................
Mounting.................................
Sealing.....................................
Material...................................
18x119x62 (WxHxD) DIN 43880 DIN rail
35mm
IP51 (indoor)
self-extinguishing UL94V-0
3. Display
3.1 Initialization Display
When it is powered on, the meter will initialize and do self-checking.
1
2
3
Full Screen. It will last for 3 seconds
Software version. It will last for 3 seconds
Total active energy (kWh)
After the self-checking program, the meter display will show the total active
energy (kWh)
3.2 Scroll Display Button
After the self-checking program, the meter display will show the total active
energy (kWh)
Click the button, the LCD display will scroll the
measurements.
1
1-1
1-2
2
3
4
5
6
7
8
9
10
11
12
Model
A-45P
A-45M
A-45CTM
Current Input
Direct connect 45A
Direct connect 45A
5A CT operated
Communication
Pulse output only
Pulse plus Modbus
Pulse plus Modbus
A-45 SERIES MID Approved B and D
Measures kWh, Kvarh, KW, Kvar,
KVA, PF, Hz, dmd, V, A, etc.
Bi-directional measurement IMP
& EXP
Two pulse outputs
RS485 Modbus
Din Rail one Module width (18mm)
45A direct connected
5 Amp C.T operated
Better than Class 1 accuracy
Autometers Systems Ltd. 4B Albany Road, Chorlton-cum-Hardy, Manchester M21 0AW
Email: [email protected] Phone: 00(44) 0161 861 9056 Fax: 0161 881 3745 www.autometers.co.uk
Ref. A-45Series.06.2021
Product development is continuous and Autometers Systems Limited reserves the right to make alterations and manufacture without notice. Products as
delivered may therefor differ from the descriptions and illustrations in this publication
To enter set up mode press the button for 3 seconds. The meter has four
progammable settings: CT1, Address, Baude Rate and Parity. Note: Under SET
mode if there is no operation, the display will revert to the default display.
7.1 CT1 Setting
Under this menu, long press the button for 3
seconds to enter the set up mode.
The first digit will flash. Press the button to increase
or decrease the number.
Long press the button for 4 seconds to confirm the
setting.
After setting the CT1 data will be automatically stored and
the display will return to the setting mode.
7.2 Modbus Address Setting
Under this menu, long press the button for 3 seconds
to enter the set up mode.
The first digit will flash. Press the button to increase
or decrease the number. Wait 4 seconds, the next digit will
flash. Repeat until correct value has been selected. After 4
seconds the address data will be automatically stored and
the display will return to the setting mode.
Modbus default: Baudrate 9600, parity Even
7.3 Baud Rate Setting
Under this menu, long press the button for 3 seconds
to enter the set up mode.
The digits will flash. Press the button to to choose the
Baud Rate options (from 1200 to 9600).
After 4 seconds the Baud Rate will be automatically stored
and the display will return to the setting mode.
7.4 Parity Setting
Under this menu, long press the button for 3 seconds
to enter the set up mode.
The digits will flash. Press the button to choose the
Parity option (none/even/odd)
After 4 seconds the Parity data will be automatically stored
and the display will return to the setting mode.
4. Communication
7. Dimensions
4.1 Pulse Output
The meter is equipped with 2 pulse outputs, which are fully
isolated from the inside circuit. That generates pulses in
proportion to the measured enerfy. The pulse outputs are
polarity dependent, passive transistor output requiring an
external voltage source for correct operation. For this external
voltage source, the voltage shall be 5-27V DC, and the
maximum input current shall be 27mA DC.
4.2 Pulse Output 1
The pulse output is configurable and can be set to generate pulses to represent
total import/export KwH or kvarh.
The default is 100 imp/kWh Import energy.
The pulse width is factory set at 100 ms.
4.3 Pulse Output 2
Pulse output 2, the constant (red light) is non configurable and is factory set to
1000 imp/kWh.
The pulse width is factory set at 60 ms.
4.4 RS 485 Output for Modbus
The A-45CTM is supplied with an RS 485 Modbus RTU protocol for communication.
The following parameters can only be set in the factory.
Parity : NONE / EVEN / ODD ( Default EVEN )
Stop bits: 1 / 2 (Default 1 )
Modbus Address : 1-247
Baud Rate :2400, 4800, 9600 (Default 9600 )
Please contact us for the detailed Modbus/M-Bus communication protocol.
Default: Autometers protocol v.6
Uimp
R
OUTPUT
P+ Com
ATTENTION: Pulse output must be fed as shown in the adjacent
wiring diagram. Ensure polarities and connection mode are
correct. Opto-coupler with potential-free SPST-No Contact.
Contact range: 5~27V DC
Max current input: 27mA DC
5. Safety
5.1 Safety Instructions
This manual does not contain all the safety instructions for the operation of the equipment
(module, device) beacuse special operating conditions and local code requirements or
regulations may neccesitate further mesasures. However, it does contain information which
must be read for your personal safety and to avoid material damages.
This information is highlighted by a warning triangle and is represented as follows, depending
on the degree of potential danger.
WARNING
This means that failure to observe the instruction can result in death, serious
injury, or considerable material damage.
CAUTION
This means hazard of electric shock and failure to take the necessary
precautions will result in death, serious injury or considerable material damage.
Qualified Personnel
Operation of the equipment (module, device) described in this manual may only
performed by qualified personnel. Qualified personnel, in this manual, means
persons who are authorised to commission, start up, ground and label devices,
systems and circuits according to safety and regulatory standards.
Proper Handling
The prerequisites for perfect, reliable operation of the product are proper transport,
storage installation, and assembly as well as proper operation and maintenance.
When operating electrical equipment, certain parts of this equipment automatically
carry dangerous voltages. Improper handling can therefore result in serious injuries
or material damage.
Use only insulating tools
Do not connect while circuit is live (hot)
Place the meter only in dry surroundings
Do not mount the meter in an explosive area or expose the meter to dust,
mildew and insects
Make sure the used wires are suitable for the maximum current of this meter
Make sure the AC wires are connected correctly before activating the current/-
voltage to the meter
Do not connect the meter to a 3 phase - 400VAC - network
Do not touch the meter connecting clamps directly with your bare hands, with
metal, blank wire or other material as you may get an electrical shock
Make sure the protection cover is placed after installation
Installation, maintentance and reparation should only be done by qualified
personnel
Never break the seals and open the front cover as this might influence the
functionality of the meter and will voic the warranty
Do not drop or allow physical impact to the meter as there are high precision
components inside that may break
6. Installation
The A45 series is designed to fit a standard 35mm DIN Rail
8. Wiring diagram
7. Progamming the Meter
Blue circle indicates Pulse Output 1 terminals (Default 100 imp/kWh)
Red circle indicates Modbus Output terminals TX+, TX-
17.5mm
35mm
119mm
45mm
62mm
A-45P A-45CTM
A-45M
G TX TX
N
L
MAINS
LOAD
N
L
MAINS
LOAD
MAINS
G
NL
TX TX
S2 P2
S1 P1
Current Transformer
LOAD

Other Autometers Systems Measuring Instrument manuals

Autometers Systems IC 995 User manual

Autometers Systems

Autometers Systems IC 995 User manual

Autometers Systems ADP3-80C User manual

Autometers Systems

Autometers Systems ADP3-80C User manual

Autometers Systems HORIZON HT-35 User manual

Autometers Systems

Autometers Systems HORIZON HT-35 User manual

Autometers Systems A-400 Series User manual

Autometers Systems

Autometers Systems A-400 Series User manual

Autometers Systems Q-180 User manual

Autometers Systems

Autometers Systems Q-180 User manual

Autometers Systems ic9 User manual

Autometers Systems

Autometers Systems ic9 User manual

Autometers Systems HORIZON HT-400 User manual

Autometers Systems

Autometers Systems HORIZON HT-400 User manual

Autometers Systems A-35M User manual

Autometers Systems

Autometers Systems A-35M User manual

Autometers Systems HORIZON HT-35 User manual

Autometers Systems

Autometers Systems HORIZON HT-35 User manual

Autometers Systems IC 970 Installation instructions

Autometers Systems

Autometers Systems IC 970 Installation instructions

Autometers Systems HORIZON HT-1095 User manual

Autometers Systems

Autometers Systems HORIZON HT-1095 User manual

Autometers Systems HORIZON HT-1095 User manual

Autometers Systems

Autometers Systems HORIZON HT-1095 User manual

Popular Measuring Instrument manuals by other brands

PCB Piezotronics IMI SENSORS EX628F01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS EX628F01 Installation and operating manual

RIEKER Flex H6EX-A2 installation manual

RIEKER

RIEKER Flex H6EX-A2 installation manual

LOVATO ELECTRIC DMG7000 instruction manual

LOVATO ELECTRIC

LOVATO ELECTRIC DMG7000 instruction manual

X-Rite X-Rite user guide

X-Rite

X-Rite X-Rite user guide

Spirax Sarco ILVA20 Installation

Spirax Sarco

Spirax Sarco ILVA20 Installation

York Survey Supply 37135 operating instructions

York Survey Supply

York Survey Supply 37135 operating instructions

LumaSense IMPAC IN 140/5 Operation manual

LumaSense

LumaSense IMPAC IN 140/5 Operation manual

Eurotops EASY READING instruction manual

Eurotops

Eurotops EASY READING instruction manual

TQ Environmental TQ4200 installation guide

TQ Environmental

TQ Environmental TQ4200 installation guide

CYP XA-3P Operation manual

CYP

CYP XA-3P Operation manual

Spectrum Technologies FieldScout 2127W manual

Spectrum Technologies

Spectrum Technologies FieldScout 2127W manual

Siemens SENTRON 7KT PAC1200 operating instructions

Siemens

Siemens SENTRON 7KT PAC1200 operating instructions

AND MS-70 Features

AND

AND MS-70 Features

Konica Minolta JM-103 user manual

Konica Minolta

Konica Minolta JM-103 user manual

Sola METRON 30 BT operating instructions

Sola

Sola METRON 30 BT operating instructions

Third Dimension Vectro2 quick start guide

Third Dimension

Third Dimension Vectro2 quick start guide

Keysight Technologies M8131A user guide

Keysight Technologies

Keysight Technologies M8131A user guide

TESTO 316-2-EX quick start guide

TESTO

TESTO 316-2-EX quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.