Baxtran BS Series User manual

BS series
Weighing/waterproof scales
User’s guide
Manualdeusuario
Manuald'usager

BS series weighing scales user’s manual
Table of Contents
SECTION 1 INTRODUCTION…................................................................................. 1
SECTION
2
SPECIFICATIONS................................................................................ 2
SECTION
3
INSTALLATION….........................................................................................3
SECTION
4
KEY DESCRIPTIONS…....................................................................... 4
SECTION
5
DISPLAYS… .............................................................................................5
SECTION
6
OPERATION… ..................................................................................... 6
6.1
Zeroing the display… .................................................................................. 6
6.2
Taring................................................................................................................... 6
6.3
change weighing unit… ....................................................................................... 6
SECTION 7 PARAMETERS & CALIBRATE… ........................................................ 7
7.1
Enter setting mode… .................................................................................. 7
7.2
Calibrate…........................................................................................................... 7
7.3
Change division................................................................................................... 7
7.4
Check internal counts… ..................................................................................... 7
7.5
Set backlight mode… ......................................................................................... 7
7.6
Set unit… ..............................................................................................................7
7.7
Set sleep time…....................................................................................................7
7.8
change capacity… ............................................................................................... 8
7.9
reset… ..................................................................................................................8
SECTION 8 BATTERY OPERATION… ................................................................... 9
SECTION 9 ERROR CODE… ............................................................................... 10

BS series weighing scales user’s manual
- 1 -
SECTION 1 INTRODUCTION
The BS/BSIseries of weighing/waterproof scales provides an accurate, fast and
versatile series of general purpose waterproof weighing scales. There are 4 models
of scales within the range. Platform size is 190mm x 230mm, capacity range from
3kg to 15kg.
All the keypads are sealed, color coded membrane switches and the displays are
large easy to read liquid crystal type displays (LCD). The LCD’s are optional with a
backlight. The scale can have two displays(rear display is optional).
All units include tare, zero, change weighing unit.

- 2 -
BS series weighing scales user’s manual
SECTION 2 SPECIFICATIONS
BS/BSI SERIES
Model #
BS/BSI-3
BS/BSI-6
BS/BSI-15
BS/BSI-25
Maximum Capacity
3kg
6kg
15kg
25kg
Readability
1g/0.5g
2g/1g
5g/2g
10g/5g
Resolution
1/3,000 or 1/6,000
Tare range
3kg
6kg
10kg
10kg
Minimum Capacity
20g/10g
40g/20g
100g/40g
200g/100g
Platform size
190mm x 230mm
Units of Measure
Kg (g, lb, tz)
Optional function
Beeper, Backlight, stainless steel pan

- 3 -
BS series weighing scales user’s manual
SECTION 3 INSTALLATION
3. 1 GENERAL INSTALLATION
The scales should be sited in a location that will not degrade the accuracy.
Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning
vents.
Avoid unsuitable tables. The tables or floor must be rigid and not vibrate. Do not
place near vibrating machinery.
Avoid unstable power sources. Do not use near large users of electricity such as
welding equipment or large motors.
Avoid high humidity that might cause condensation. Do not immerse the scales in
water.
Avoid air movement such as from fans or opening doors. Do not place near open
windows.
Keep the scales clean.
Do not stack material on the scales when they are not in use.
3.2 INSTALLATION of BS/BSI SERIES
BS/BSIseries waterproof scales use AC adapter and rechargeable battery powered.
Please attention the power source voltage accord with the mark of the adapter.
AC adapter socket at the bottom the scale, you can overturn the scale before you
charging the battery.

- 4 -
BS series weighing scales user’s manual
SECTION 4 KEY DESCRIPTIONS
KEY
DESCRIPTION
Primary function (normal
use)
Second function (in
program)
ON/OFF
turn on / OFF the power
TARE/UNIT
-
press this key to tare
-
hold this key for 4
seconds to change
weighing unit
Enter function for accept
the active option
ZERO
make the scale zero

- 5 -
BS series weighing scales user’s manual
SECTION 5 DISPLAYS
The LCD display will show a value and some marks under the digits.
Zero indicator
Stability indicator
Tare indicator, current scales in net weight mode
Low battery indicator, charging the battery at once when this indicatoron
current weighing unit is kg
current weighing unit is second weighing unit (setting by F4 UNT)

- 6 -
BS series weighing scales user’s manual
SECTION 6 OPERATION
6.1
Zeroing The Display
You can press the ZERO key at any time to set the zero point from which all other
weighing, within 2% of power up zero. This will usually only be necessary when the
platform is empty. When the zero point is obtained the display will show the indicator
for zero.
The scale has an automatic rezeroing function to account for minor drifting or
accumulation of material on the platform. However you may need to press the ZERO
key to rezero the scale if small amounts of weight are shown when the platform is
empty.
Note: if current weight more then 20% of capacity, Zero function will disable.
6.2
Taring
Zero the scale by pressing the ZERO key if necessary. The zero indicator will be on.
Place a container on the platform, a value for its weight will be displayed.
Press the TARE/UNIT key to tare the scale. The weight that was displayed is stored
as the tare value and that value is subtracted from the display, leaving zero on the
display. The "NET" indicator will be on. As product is added only the weight of the
product will be shown. The scale could be tared a second time if another type of
product was to be added to the first one. Again only the weight that is added after
taring will be displayed.
When the container is removed a negative value will be shown. If the scale was tared
just before removing the container this value is the gross weight of the container plus
all product that was removed. The zero indicator will also be on because the platform
is back to the same condition it was when the ZERO/ENTER key was last pressed.
6.3
Change weighing unit
Hold TARE/UNIT for 4 seconds will change weighing unit, relevant weighing unit
mark turn on(kg or u2)

- 7 -
BS series weighing scales user’s manual
SECTION 7 PARAMETERS & CALIBRATION
7.1
Enter setting mode
The scale has 10 parameters that can be set by the user plus a method of entering
the calibration section.
To set parameters or calibration, hold TARE/UNIT key ,then press ON/OFF key ,untill
it shows F0 CAL .
7.2
Calibrate
After enter setting mode, the display will show the first function, "F0 CAL". press
TARE/UNIT key, display shows “UNLOAD”, empty the platter, after STABLE indicator
on, press TARE/UNIT key again, display shows the calibrate weight, you can press
ZERO key to select calibrate weight, after you select, press TARE/UNIT key, display
shows “LOAD”, put the calibrate weight on the pan , after STABLE indicator on, press
TARE key to sure, display shows “PASS”, after BS/BSI selfchecking again, and is
ready for you.
7.3
Change division
After enter setting mode, the display shows “F0 CAL”, press ZERO key, display
shows “F1 INC”, press TARE/UNIT key to enter, press ZERO key to select
division(range 0.5/1/2), press TARE/UNIT key to sure, press ZERO key and
TARE/UNIT key at the same time to escape.
7.4
Check internal counts
After enter setting mode, display shows “F0 CAL”, press ZERO key twice, display
shows “F2 INP”, press TARE/UNIT key to enter, display shows internal counts, press
TARE/UNIT key and ZERO key at the same time to escape.
7.5
Set backlight mode
After enter setting mode, display shows “F0 CAL”, press ZERO key three times,
display shows “F3 BK”, press TARE/UNIT key to enter, press ZERO key change
backlight mode(AU: automatic, OFF: off, ON: on), press TARE/UNIT key and ZERO
key at the same time to escape.
7.6
Set unit
After enter setting mode, display shows “F0 CAL”, press ZERO key four times,
display shows “F4 unt” , press ZERO key to change the second Unit.(g: gram, TL:
Taiwanese liang, lb: ounce)
7.7
Set sleep time
After enter setting mode, display shows “F0 CAL”, press ZERO key five times,
display shows “F5 OFF”, press ZERO key to change the time for sleep .(range
0,3,5,10,20 minute)

- 8 -
BS series weighing scales user’s manual
7.8
Change capacity
Before this operate, please short K4
After enter setting mode, display shows “F0 CAL”, press ZERO key six times, display
shows “F6 CAP”, press TARE key, display show “pin---“, waiting for input password,
press TARE key and ZERO key to input password (TARE key for increase value,
ZERO key for move active digit), default password is “315”, after input correct
password, display will show capacity, press TARE key to change(option: 3kg, 6kg,
15kg, 25kg), press ZERO key to sure
7.9
Auto zero range
After enter setting mode, display shows “F0 CAL”, press ZERO key seven times,
display shows “F7 Azn”, press TARE key, the parameters will set the auto zero
range.(option: 0.5d/1d/2d/4d)
7.10
Speed
After enter setting mode, display shows “F0 CAL”, press ZERO key seven times,
display shows “F8 SPD”, press TARE key, the parameters will set weighing
speed.( option: 7.5/15/30 times).
7.11
Reset
After enter setting mode, display shows “F0 CAL”, press ZERO key seven times,
display shows “F9 RST”, press TARE key, the parameters will set back to the default
value(factory mode).
7.12
Gravity
To set gravity, press TARE/UNIT and ZERO key together, when the scale in the self
test. it will show GRAV, input the gravity value, then press ZERO key to make sure.

- 9 -
BS series weighing scales user’s manual
SECTION 8 BATTERY OPERATION
The weighing indicator can be operated from the battery if desired. The battery life is
approximately 100 hours. (without backlight)
When the battery needs charging BAT LO indicator will turn on. The battery should
be charged when the symbol is on. The scale will still operate for about 10 hours after
which it will automatically switch off to protect the battery.
To charge the battery simply plug into the mains power. The scale does not need to
be turned on.
The battery should be charged for 24 hours for full capacity.
Just under the quantity display is an LED to indicate the status of battery charging.
When the scale is plugged into the mains power the internal battery will be charged.
If the LED is green the battery has a full charge. If it is Red the battery is nearly
discharged and yellow indicates the battery is being charged.
As the battery is used it may fail to hold a full charge. If the battery life becomes
unacceptable then contact your distributor or TAIWANSCALE corporation.

- 10
-
BS series weighing scales user’s manual
SECTION 9 ERROR CODES
ERROR
CODES
DESCRIPTION
RESOLUTION
- -OL -
Over range
Remove weight from the scale.
If the problem persist contact your dealer or
Taiwan scale for assistance.
Err 4
Zero Setting Error
The scale was outside the normal zero setting
range either when it was turned on or when the
ZERO key was pressed.
Remove weight from the scale and try again.
Use the TARE key to set the display to zero value.
If the problem persist contact your dealer or
Taiwan scale for assistance.
Err 6
A/D out of range
The values from the A/D converter are outside the
normal range. Remove weight from the scale if
overloaded, make sure the pan is attached.
Indicates the load cell or the electronics may be
faulty.
If the problem persist contact your dealer or
Taiwan scale for assistance.

BS series weighing scales user’s manual
- 11
-
BAXTRAN SCALE is a international supplier with more than 30 years experience in the
production and sale of electronic weighing equipment.
Products are supplied and serviced from our company locations in the CHINA, TAIWAN and
distributed through a world wide dealer network, also we make OEM/ODM products for world
wide customer.
BAXTRAN SCALE's products are predominantly designed for the laboratory, medical, business
and industrial markets.
The product range can be summarised as follows:
Counting scales for general industrial and warehouse applications
Digital weighing/check-weighing scales
High performance platform scales with extensive software facilities including parts
counting, percent weighing etc.
Digital electronic scales for medical use
Retail price computing scales
Floor scales
Truck scale
Crane scales
Weighing indicator for platform scales, floor scales and truck scales
Hand push and pull gauge
Customize auto weighing systems
BAXTRAN SCALE and their distributors offer a full range of technical services such as on site
and workshop repair, preventative maintenance and calibration facilities.
BAXTRAN SCALE operates an approved quality management system and is certified to
ISO9001:2000.
Visit our Website at: www.baxtran.com
BAXTRAN Scale reserves the right to make changes to the technology, features, specifications
and design of the equipment without notice.
All information contained within this publication was to the best of our knowledge timely, complete
and accurate when issued. However, we are not responsible for misimpressions which may
result form the reading of this material.
The latest version of this publication can be found on our Website.

MANUALDEUSUARIO
Balanzas SoloPeso
modelos BS
- 12
-
ÍNDICE
1.
INTRODUCCIÓN 13
2.
ESPECIFICACIONES
13
3.INSTALACIÓN
3.1.
INSTALACIÓN GENERAL 13
3.2.
INSTALACIÓN DE LA SERIE BS 14
4.
DESCRIPCIÓN DE LAS TECLAS 14
5.
DISPLAY 14
6.
OPERATIVA
6.1.
AUTOCERO 14
6.2.
FIJACIÓN DELA TARA 14
6.3.
CAMBIO DE LA UNIDAD DE PESO 15
7.
CONFIGURACIÓN
7.1.
ENTRADA ENELMODO DE CONFIGURACIÓN 15
7.2.
CALIBRACIÓN
15
7.3.
CAMBIO DE ESCALÓN 15
7.4.
VERIFICACIÓN DE DIVISIONES INTERNAS 15
7.5.
PROGRAMACIÓN DE RETROILUMINACIÓN
15
7.6.
SELECCIÓN DE UNIDADES 16
7.7.
PROGRAMACIÓN DE AUTOAPAGADO (SLEEP)
16
7.8.
FILTRO DE PESO 16
8.
FUNCIONAMIENTOCONBATERIA 17
9.
CÓDIGOS DE ERROR 18

MANUALDEUSUARIO
Balanzas SoloPeso
modelos BS
- 13
-
1. INTRODUCCIÓN
NOTA:Estasbalanzasnosonaptasparalosusosindicadosenelapartado2adelartículo1ºdela
Directiva 90/384/CE
Laserie BS de balanzas proporciona una serie precisa, rápida y versátil de balanzas de pesaje para
todouso.Hay3modelosdebalanzasdentrodeestagama.Eltamañodelaplataformaesde190mmx
230mm, los posibles alcances van de 3 kg a 15 kg.
Todoslos teclados están sellados, los interruptores de membrana están marcados por color y las
pantallasdevisualización sondisplaysdecristallíquido(LCD)degrantamañoyfácilesdeleer.Los
LCDs incorporan retroiluminación.
Todas las unidades incluyen tara, cero, cambio de la unidad de peso, cambio de función de división.
Laserie debalanzas BSlleva una protección contra polvo y líquidos equivalente a IP-68.
2. ESPECIFICACIONES
BS y BSI
Nº modelo
BS-BSI 3
BS-BSI 6
BS-BSI 15
Alcance
3 Kg
6 Kg
15 Kg
Escalón
1 g / 0,5 g
2 g / 1 g
5 g / 2 g
Resolución
1/3.000 o 1/6.000
Tara máxima
-3 Kg
-6 Kg
- 15 Kg
Peso mínimo
20 g / 10 g
40 g / 20 g
100 g / 40 g
Tamaño del plato
190mm x 230mm
Unidades
Kg
Opcional
Buzzer, retroiluminación, plato de acero inoxidable.
3. INSTALACIÓN
3.1.
INSTALACIÓN GENERAL
La balanza debe ser colocada sobre una superficie firme y bien nivelada.
Evite temperaturas extremas. No coloque la balanza directamente bajo la luz del sol ni cerca de
conductos de salida de aire acondicionado.
Evite las mesas inestables. Las mesas o el suelo deben ser rígidos y no vibrar. No coloque la balanza
cerca de maquinaria que vibre.
Evite las tomas de corriente inestables. No utilice la balanza cerca de equipos con mucho consumo
eléctrico como equipamiento de soldadura o grandes motores.
Evite movimientos de aire como los procedentes de ventiladores y la apertura de puertas. No coloque la
balanza cerca de ventanas abiertas.
Mantenga la balanza limpia.
Mantenga la balanza seca.
No apile material sobre la balanza cuando no está en uso.

MANUALDEUSUARIO
Balanzas SoloPeso
modelos BS
- 14
-
0
ZERO
Tare/Unit
ZERO
3.2.
INSTALACIÓN DE LA SERIE BS
Las balanzas de las series BS-BSI utilizan un adaptador de corriente alterna y funcionan asimismo con
batería recargable. Por favor, asegúrese de que el voltaje de la corriente eléctrica se corresponde con el
marcado en el adaptador.
El enchufe para el adaptador a corriente alterna está situado en la parte inferior de la balanza.
4. DESCRIPCIÓN DE LAS TECLAS
TECLA
DESCRIPCIÓN
FUNCIÓN PRIMARIA
FUNCIÓN SECUNDARIA
ON/OFF
Enciende y apaga la balanza.
Tare/Unit
Pulse esta tecla para tarar la balanza.
Mantenga pulsada esta tecla durante 4
segundos para cambiar la unidad de peso.
Permitefijarograbarlosparámetrosu
otras funciones.
ZERO
Pone a cero la balanza.
Selecciona cada uno de los parámetros y
sus respectivas opciones.
5. DISPLAY
El display LCD mostrará un valor y algunas marcas bajo los dígitos.
: indicador de cero
: indicador de estabilidad
NET : indicador de tara
Bat. Lo : Indicador de batería baja, cargue la batería una vez que el indicador esté encendido
kg : la unidad actual de peso es el kg
Lb : la unidad actual de peso es la libra
6. OPERATIVA BÁSICA
6.1.
AUTOCERO
Puede pulsar en cualquier momento para fijar el cero. Aparecerá el indicador de cero.
La balanza tiene una función de puesta a cero automática para resolver pequeños problemas de desvío
o acumulación de material sobre el plato.
6.2.
FIJACIÓN DE LA TARA
Ponga la balanza a cero pulsando la tecla si es necesario. Se activara el indicador de cero.
Coloque un envase sobre la plataforma y aparecerá un valor de peso.
Pulselatecla
para fijar la tara de la balanza. El peso que apareció en el display se almacena
comovalordetarayesevaloresdeducidodeldisplay,dejándoloencero.Se activaraelindicador
“
NET
”(NETO). A medida que se añade producto, sólo semostrará el peso del producto. Labalanza
podría ser tarada por segunda vez si se fuera a añadir otro tipo de producto al primero. Nuevamente,
sólo se mostrará el peso que se añada después de fijar la tara.
Efectúe una calibración de peso tal como se describe en el apartado 7.2 ( Calibración).

MANUALDEUSUARIO
Balanzas SoloPeso
modelos BS
- 15
-
ZERO
Tare/Unit
Tare/Unit
Tare/Unit
Tare/Unit
ZERO
Tare/Unit
Tare/Unit
ZERO
Tare/Unit
ZERO
Tare/Unit
ZERO
Tare/Unit
ZERO
ZERO
ZERO
ZERO
Tare/Unit
ZERO
Tare/Unit
Tare/Unit
Tare/Unit
Cuandose retiraelenvase,se mostraráunvalornegativo.Silabalanzafuetaradaantesde quitarel
envase,estevaloresel pesobrutodelenvasemástodoelproductoquese quitó.Elindicadordecero
también estará encendido porque la plataforma vuelve a estar en la misma situación en la que estaba
cuando se pulsolatecla
.
6.3 CAMBIO DE LA UNIDAD DE PESO
Mantenga pulsada la tecla
dedurante4segundosylaunidaddepesocambiaráyse
encenderá la unidad de peso correspondiente (kg o lb).
7. CONFIGURACIÓN
7.1.
ENTRADA EN EL MODO DE CONFIGURACIÓN
La balanza tiene 7 parámetros que pueden ser fijados por el usuario. Existe además un procedimiento
para entrar en la sección de calibración.
Para fijar los parámetros o la calibración, encienda el equipo con la tecla
pulsada y aparecerá
F0 CAL
.
7.2.
CALIBRACIÓN
Despuésdeentrar enel menúde configuración,el displaymostrarálaprimera función"CAL".Pulsela
tecla y el display mostrará “UNLOAD”(DESCARGA), vacíe el plato y cuando se active el
indicador de
ESTABLE
, pulse nuevamente la tecla .Eldisplaymostraráel pesodecalibración
solicitado, pulsando la tecla
se selecciona el peso de calibración (en kg) a utilizar (Ej. para
alcance6kg:A02, A1 4,A26).Unavezseleccionado,puede pulsarlatecla
y el display
mostrara “LOAD” (CARGA). Coloque el peso seleccionado sobre la balanza y se activará el indicador
ESTABLE. Pulsela tecla
para guardar. El display mostrará ahora “PASS”. Después la BS-BSI
hará una auto comprobación y estará lista para comenzar a trabajar.
7.3.
CAMBIO DE ESCALÓN
Despuésdeentrarenel mododeconfiguración,eldisplaymuestra“F0CAL”,pulselatecla
y
el
display mostrará "F1 INC". Pulse la tecla paraentrar,pulselatecla para
seleccionar división: (Ej. Para alcance 6kg: 1 ó 2g), pulse latecla paragrabar.Pulselatecla
y la
tecla
al mismo tiempo para salir.
7.4.
VERIFICACIÓN DE DIVISIONES INTERNAS
Despuésdeentrarenel mododeconfiguración,eldisplaymuestra“F0CAL”,pulselatecla dos
veces y el display mostrará “F2 INP”. Pulse la tecla para entrar y el display muestra las
divisiones internas. Pulse la tecla
y la tecla al mismo tiempo para salir.
7.5.
PROGRAMACIÓN DE RETROILUMINACIÓN
Despuésdeentrarenelmododeconfiguración,eldisplaymuestra“F0CAL”,pulselatecla
tres veces y el display mostrará “F3 BT”. Pulse la tecla
para entrar y pulse la tecla
para programar la retroiluminación (AU= automático, OFF:=desactivado, ON= siempre activado).
Pulselatecla ylatecla al mismo tiempo parasalir.

MANUALDEUSUARIO
Balanzas SoloPeso
modelos BS
- 16
-
Tare/Unit
ZERO
ZERO
ZERO
ZERO
Tare/Unit
ZERO
Tare/Unit
ZERO
7.6.
SELECCIÓN DE UNIDADES
Después de entrar en el modo de configuración, el display muestra “F0 CAL”, pulse la tecla
cuatroveces,yel displaymuestra“F4unt”.Pulselatecla
Tare/Unit
para entrar y después pulse la tecla
paraseleccionarlasegundaunidad.Pulselatecla
Tare/Unit
tiempo para salir.
y latecla al mismo
7.7.
PROGRAMACIÓN DE AUTOAPAGADO (SLEEP)
Unavezdentrodelmododeconfiguracióneldisplaymuestra“F0CAL”,pulselatecla
c
inco
veces, y el display muestra “F5 oFF”. Pulse la tecla para entrar y después la tecla
para cambiar el tiempo de autoapagado (opciones “oN”, 3, 5, 10 y 20 minutos). Pulse la tecla
ylatecla al mismo tiempo para salir.
7.8.
FILTRO DE PESO
Después de entrar en el modo de configuración el display muestra “F0 CAL”, pulse la tecla
seisveces,eldisplaymuestra “F6FLT”.Pulselatecla para entrar y después pulse la tecla
paracambiarelvalordelfiltrodepesoaplicado.Lasposiblesopcionesson:1,2,3,4.Amedida
quese aumentael valor,el peso será más preciso y labalanza pesará más lentamente. Pulse latecla
ylatecla al mismo tiempo para salir.
ZERO
ZERO
Tare/Unit
ZERO

MANUALDEUSUARIO
Balanzas SoloPeso
modelos BS
- 17
-
8. FUNCIONAMIENTO CON BATERÍA
Cuando la batería necesita ser recargada, se enciende el indicador Bat Low. Por favor, cargue la batería o use
un adaptador de corriente alterna cuando vea este indicador encendido.
Las balanzas pueden funcionar con baterías si se desea. La duración de la batería es de aproximadamente
100 horas.
Para cargar la batería sólo tiene que enchufarla a la red eléctrica. No es necesario encender la balanza.
La recarga debería durar 24 horas para llenar la batería a plena capacidad.
Hay un LED que indica el estado dela carga de la batería. Cuando la balanza está enchufada a la red
eléctrica, la batería interna se cargará. Si el LED es verde la batería tiene carga completa. Si es rojo, la batería
necesita carga, y el amarillo indica que la batería está en proceso de recarga.
Con el uso, la batería puede ir perdiendo capacidad de hacer cargas completas. Si la duración de la carga de
la batería se hace inaceptable, póngase en contacto con su distribuidor.
Nota: las baterías nuevas están parcialmente cargadas. Antes de poder utilizar su balanza, debe instalar y
cargar la batería siguiendo las siguientes instrucciones.
Algunas baterías tienen un mejor rendimiento después de varios ciclos completos de carga/descarga.
El rendimiento de las baterías depende de numerosos factores, incluida la configuración de la retroiluminación
y la operativa.
No utilice nunca un cargador o una batería que estén dañados.
No haga un cortocircuito en la batería. Se puede producir un cortocircuito
accidental cuando un objeto metálico (moneda, clip o bolígrafo) causa
unaconexióndirectadelos polos
+
y–delabatería(tirasmetálicas dela
batería), por ejemplo cuando lleva una batería de repuesto en el bolsillo.
Hacer un corto-circuito de los polos puede dañar la batería o el objeto que
se conecta.
No tire las baterías al fuego.
Tire las baterías siguiendo la reglamentación local (por ejemplo, reciclaje).
No tire las baterías como basura doméstica.
Evite cargar la batería en condiciones de falta de aire.
A fin de maximizar el rendimiento de su batería:
Use siempre baterías y adaptador de CA originales.. La garantía de la balanza no cubre los daños causados
como consecuencia del uso de otras baterías y/o cargadores diferentes.
Latensión desalidadeladaptador CA es de9V,peroelrangodetensión normaloscilará entrelos11Vylos
15V.
Las baterías nuevas o aquellas baterías que hayan sido almacenadas durante largos periodos de tiempo
pueden requerir un mayor tiempo de carga.
Mantenga la batería a temperatura ambiente o una temperatura próxima cuando efectúe la carga.
No exponga las baterías a temperaturas inferiores a -10°C o superiores a 45°C.
En el transcurso de periodos de tiempo largo, las baterías van perdiendo progresivamente capacidad de
carga y requieren tiempos de recarga más largos.
Esto es normal. Si usted carga la batería regularmente y observa que disminuye el periodo de funcionamiento
o que aumenta el periodo de carga, probablemente es momento de adquirir una nueva batería.

MANUALDEUSUARIO
Balanzas SoloPeso
modelos BS
- 18
-
9. CÓDIGOS DE ERROR
CÓDIGO
DE ERROR
DESCRIPCIÓN
RESOLUCIÓN
--OL-
Por encima del rango.
Quite el peso de la balanza.
Si el problema persiste contacte con su
distribuidor para asistencia.
Err 4
Error de configuración cero.
La balanza no estaba correctamente
configurada en el cero o bien fue encendida
cuando se pulsó la tecla
ZERO .
Quite el peso de la balanza y pruebe
nuevamente.
Uselatecla Tare/Unit paraponereldisplayen
valor cero.
Si el problema persiste contacte con su
distribuidor para recibir asistencia.
Err 6
A/D fuera de rango
Los valores del convertidor A/D están fuera del
rango normal. Quite el peso de la balanza si
hay un exceso de peso, asegúrese de que se
coloca el plato.
Indica quela célula de carga o laelectrónica
puede noestarfuncionandocorrectamente.
Si el problema persiste contacte con su
distribuidor.
This manual suits for next models
9
Table of contents
Other Baxtran Scale manuals

Baxtran
Baxtran BBS User manual

Baxtran
Baxtran DSN User manual

Baxtran
Baxtran BAC User manual

Baxtran
Baxtran STR User manual

Baxtran
Baxtran RTN User manual

Baxtran
Baxtran DSC30 User manual

Baxtran
Baxtran STI User manual

Baxtran
Baxtran DSC User manual

Baxtran
Baxtran SAN User manual

Baxtran
Baxtran DSN30 User manual

Baxtran
Baxtran Giropes TOUCH Series User manual

Baxtran
Baxtran TC15 User manual

Baxtran
Baxtran DSC User manual

Baxtran
Baxtran FFN3 User manual

Baxtran
Baxtran Giropes GLASSKS LCD User manual

Baxtran
Baxtran APM User manual

Baxtran
Baxtran PD User manual

Baxtran
Baxtran ABD User manual

Baxtran
Baxtran SNU User manual

Baxtran
Baxtran Super SS User manual