manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BEA
  6. •
  7. Security Sensor
  8. •
  9. BEA ACTIV8 ONE ON User manual

BEA ACTIV8 ONE ON User manual

BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA.BE
2
1
4
5
1
2
1
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
1
1
1
2
1
2
1
2
3
1
2
©
BEA
|
O
ri
g
ina
l
instructions
|
42
.7114
/
V
3
- 11.1
0
BEA hereby declares that the ACTIV8 ONE ON is in conformity with the basic requirements and the other
relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/EC.
Notified Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, November 2010 Jean-Pierre Valkenberg, Authorized representative
The complete declaration of conformity is available on our website: www.bea.be
LED-SIGNALS
The ORANGE LED
flashes 1 x.
The ORANGE LED
flashes 2 x.
The ORANGE LED
flashes 4 x.
The ORANGE LED
flashes 5 x.
The ORANGE LED
flashes every second.
The ORANGE LED
is on.
The RED LED flashes
quickly after an
assisted setup.
The RED LED
lights up
sporadically.
The GREEN LED
lights up
sporadically.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
The sensor goes into
security mode.
The sensor signals
an internal fault.
Irregularities in the
power supply
The sensor receives
not enough IR-energy.
The sensor receives
too much IR-energy.
The sensor encounters
a memory problem.
The sensor vibrates.
The sensor sees the door
during the assisted setup.
The sensor sees the door.
The sensor is disturbed by
lamps or another sensor.
The sensor is disturbed
by the rain.
The sensor is disturbed by
rain and/or leaves.
The sensor vibrates.
Ghosting
The sensor sees the door
or other moving objects.
Check power supply.
Check wiring.
Use the 1 m prism if possible.
Check the angle of the IR-curtains.
Cut and restore power supply.
Cut and restore power supply.
If orange LED lights up again, replace sensor.
Check the angle of the IR-curtains.
Launch a new assisted setup.
Attention: Do not stand in the detection field!
Check output configuration setting.
Switch value 1 (A-P) to 4 (A-A) or 4 to 1 by
remote control.
Use a low energy prism if possible.
Check the angle of the IR-curtains.
Check if the sensor is fastened firmly.
Check position of prism and cover.
Choose a different frequency by remote control.
Increase the IR-immunity filter to value 2 or 3.
Select presetting 2 or 3 by push button.
Select presetting 2 or 3 by push button.
Increase radar-immunity filter by remote control.
Change radar antenna angle.
Check if the sensor is fastened firmly.
Check position of cable and cover.
Change radar antenna.
Change radar field size (sensitivity).
Remove the objects if possible.
Launch an assisted setup and adjust the IR angle.
Cut and restore power supply.
If orange LED flashes again, replace sensor.
*excludes DIN18650-conformity of the door system
Check connections to test output.
If your door controller is not able to test the sensor,
connect the red and blue cable to power supply.*
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
Only trained and qualified personnel may install and setup the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
ACTIV8 ONE ON
3
2
4
1
5
6
7
E
R
L
A
U
B
T
Z
E
R
T
I
F
I
Z
I
E
R
U
N
G
N
A
C
H
DIN 18650
E
N
A
B
L
E
S
A
C
C
O
R
D
A
N
C
E
W
I
T
H
TECHNICAL SPECIFICATIONS
1. IR-prism (2 m)
2. radar antenna (wide field)
3. radar antenna (narrow field)
4. cover
DESCRIPTION
Presence
Typical response time: <128 ms (max. 500 ms)
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24 or 12 by curtain
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
Solid-state-relay
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable)
Typical: < 15 ms (max. 25 ms)
ENGLISH
Opening & safety sensor
for automatic sliding doors
5. push buttons
6. IR-curtain ajustment screw
7. main connector
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10% (to be operated from SELV compatible power supplies only)
< 3 W
1.8 m to 4 m (< 3 m to enable DIN 18650-conformity)
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
5 years
R&TTE 1999/5/EC; EMC 2004/108/EC; MD 2006/42/EC; EN 12978
EN ISO 13849-1:2008 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Expected lifetime:
Norm conformity:
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm2
From 15 ° to 50 ° vertical (adjustable)
Relay (free of potential)
Max. contact voltage: 42 V AC/DC
Max. contact current: 1 A (resistive)
Max. switching power: 30 W (DC)/60 VA (AC)
0.5 s to 9 s (adjustable)
Detection mode:
Technology:
Angle:
Output:
Hold time output signal:
Response time on test request:
GREEN
LED
RED
LED
For product version 0600 and more
S
peci
fi
cations are subject to changes without prior notice.
All values measured in optimal conditions.
Other use of the device is outside the permitted purpose
and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect
installations or inappropriate adjustments of the sensor.
Please keep for further use
Designed for colour printing
1
2
3
0
1
2
12
0
1
2
33
3
9
1
0
1
2
12
0
1
2
33
0
1
2
12
0
1
2
33
0
1
0
1
2
«click»
max.
5 cm
max 5 cm
12-24 V
AC-DC
*
*
ACTIV8 ONE ON
0
1
2
12
0
1
2
33
3
9
1
H
W
H
W
2 m 1 m
MOUNTING & WIRING
RADAR FIELD - OPENING IMPULSE
INFRARED FIELD - SAFETY
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED**
BLUE**
POWER SUPPLY
OPENING INPUT
OPENS DOOR
SAFETY INPUT
KEEPS DOOR OPEN
TEST
OUTPUT
2.2 m
WIDTH
ANGLE
4 m x 2 m 2 m x 2.5 m
Check position of
IR-curtains with
Spotfinder and
adjust if necessary.
WIDTHANGLE
TIP: Launch an ASSISTED SETUP to verify wiring, position of the curtains and correct functioning of the sensor.
It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
DOOR
ORANGE
GREEN
LED
RED
LED
* Output status when sensor is operational
** For compliance with DIN 18650, connection
to door controller test output is required.
2.2 m
Max. mounting height: 3 m
Max. mounting height: 4 m
(>3 m excludes DIN18650-conformity)
CLOSER
CLOSER
AWAY
AWAY
2.2 m
The door control unit and the door cover profile must be correctly earthed.
SENSOR
Detection field width indicated according to conditions defined in DIN 18650 and including dimension of test body CA.
HW
2.20 m 2.35 m
2.50 m 2.50 m
3.00 m 2.70 m
The width of the radar field varies according to the mounting height of the sensor.
HW
2.20 m 1.35 m
2.50 m 1.50 m
3.00 m 1.70 m
>>>>>
12
4
P-AP-P
A-PA-A
0
1
2
1
2
0
1
2
33
3
+
0
1
2
1
2
0
1
2
33
3
-
XXS XS S > > > > L XL XXL
XXS, XS, S ... ... L, XL, XXL
>
ACTIV8 ONE ON
>
1
5
>
+
>>>>
SETTINGS (by push buttons and/or remote control)
SHORT PUSH RIGHT:
+ 1 VALUE
SHORT PUSH LEFT:
- 1 VALUE
STANDARD
CRITICAL ENVIRONMENT
SHOPPING STREET
PUSH LEFT
(KEEP PUSHED)
RELEASE AFTER
FLASH OF DESIRED
SETTING
PRESETTING
SELECTED
RADAR FIELD SIZE
(SENSITIVITY)
PRESETTINGS
OFF
3x GREEN LED
excludes DIN18650-conformity of the door system
FIELD SIZE (SENSITIVITY)
IMMUNITY FILTER
DETECTION MODE
HOLD TIME
OUTPUT SIGNAL
NUMBER OF
CURTAINS
IMMUNITY FILTER*
MAX. PRESENCE
TIME
PULSE FREQUENCY
TEST (MONITORING)
OUTPUT
CONFIGURATION
service mode = no detection is active during 15 minutes (maintenance).
dynamic mode = 2nd curtain is only active during motion detection.
auto = the sensor will automatically adapt to the door controller:
when the door controller monitors the sensor > on
when the door controller does not monitor the sensor > off (excludes DIN18650-conformity)
L= 3.20 m x 1.40 m
(at 2.2 m)
A = active output (NO-contact)
P = passive output (NC-contact)
bi uni uni
AWAY
dynamic
mode
service
mode
on auto
off
FACTORY VALUES
low
30 s1 min 2 min 5 min 10 min 20 min 60 min
freq A freq A+ freq B+
normal
0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
RED-GREEN
highnormal
Opening
Safety
motion
OUTPUT
REDIRECTION
motion
or
presence
motion
and
presence
opening output is active in case of: 0 motion detection
1 motion or presence detection
2 motion and presence detection
OR
RED-GREEN
PUSH
LEFT + RIGHT
bi = two-way detection; uni = one-way detection towards sensor;
uni PRM = for persons with reduced mobility; uni AWAY = away from sensor
uni
PRM
QUICK SETUP = ASSISTED SETUP =
SETUP (step out of the detection field during setup)
PUSH RIGHT UNTIL
OPEN+CLOSE RED-GREEN OFF
RED-GREEN
FLASHES
OR
RESETTING TO
FACTORY VALUES
RED-GREEN OFF
IMPORTANT: Test the good functioning of the installation before leaving the premises.
medium high
* In immunity 2 and 3, the standard detection capability is the same as in immunity 1 (factory setting). Environmental and installation conditions can
affect the detection capability of the sensor or can impact the availability of the door system. During harsh conditions, the sensor can temporarily
adapt the detection capability to ensure the availability of the door system.
immunity 3 is only suitable if a combined
sensor is on each side of the door
freq B

Other BEA Security Sensor manuals

BEA LZR FLATSCAN SW User manual

BEA

BEA LZR FLATSCAN SW User manual

BEA LZR- FLATSCAN REV-PZ User manual

BEA

BEA LZR- FLATSCAN REV-PZ User manual

BEA WIZARD II SMR User manual

BEA

BEA WIZARD II SMR User manual

BEA IXIO-S CAN User manual

BEA

BEA IXIO-S CAN User manual

BEA MATRIX-3 User manual

BEA

BEA MATRIX-3 User manual

BEA Matrix2-S User manual

BEA

BEA Matrix2-S User manual

BEA FAAC XV1 User manual

BEA

BEA FAAC XV1 User manual

BEA LZR-FLATSCAN 3D SW User manual

BEA

BEA LZR-FLATSCAN 3D SW User manual

BEA EAGLE X-MTF User manual

BEA

BEA EAGLE X-MTF User manual

BEA LZR-WIDESCAN User manual

BEA

BEA LZR-WIDESCAN User manual

BEA IRIS User manual

BEA

BEA IRIS User manual

BEA IXIO-DT1 User manual

BEA

BEA IXIO-DT1 User manual

BEA LZR-FLATSCAN SW User manual

BEA

BEA LZR-FLATSCAN SW User manual

BEA IXIO-DT1 User manual

BEA

BEA IXIO-DT1 User manual

BEA IXIO-DO1 I User manual

BEA

BEA IXIO-DO1 I User manual

BEA DK-12 User manual

BEA

BEA DK-12 User manual

BEA 10LZRWIDESCAN User manual

BEA

BEA 10LZRWIDESCAN User manual

BEA LZR FLATSCAN S User manual

BEA

BEA LZR FLATSCAN S User manual

BEA IXIO-ST User manual

BEA

BEA IXIO-ST User manual

BEA 10MATRIX User manual

BEA

BEA 10MATRIX User manual

BEA LZR-MICROSCAN T User manual

BEA

BEA LZR-MICROSCAN T User manual

BEA LZR-FLATSCAN W User manual

BEA

BEA LZR-FLATSCAN W User manual

BEA IXIO-ST INDUSTRIAL User manual

BEA

BEA IXIO-ST INDUSTRIAL User manual

BEA G3 User manual

BEA

BEA G3 User manual

Popular Security Sensor manuals by other brands

Bosch Photobeam 5000 Installation and operation guide

Bosch

Bosch Photobeam 5000 Installation and operation guide

Linear DXS-54/EC installation instructions

Linear

Linear DXS-54/EC installation instructions

RKI Instruments 35-3001A-13-XX Operator's manual

RKI Instruments

RKI Instruments 35-3001A-13-XX Operator's manual

GE VE1012 Series Installation sheet

GE

GE VE1012 Series Installation sheet

Campbell SurfaceVue 10 product manual

Campbell

Campbell SurfaceVue 10 product manual

netvox S31501 user manual

netvox

netvox S31501 user manual

Rokonet WatchOUT installation instructions

Rokonet

Rokonet WatchOUT installation instructions

YOKOGAWA TB830D Start-up

YOKOGAWA

YOKOGAWA TB830D Start-up

Siemens FDOOT271 Technical manual

Siemens

Siemens FDOOT271 Technical manual

Friendtrol Technologies TMS PLUS Series manual

Friendtrol Technologies

Friendtrol Technologies TMS PLUS Series manual

NA-DE 10550 quick start guide

NA-DE

NA-DE 10550 quick start guide

AUSTRIALPIN NO.MAD operating instructions

AUSTRIALPIN

AUSTRIALPIN NO.MAD operating instructions

Qiagen FLUO SENS manual

Qiagen

Qiagen FLUO SENS manual

Art ROPEGUIDE 2010 instruction manual

Art

Art ROPEGUIDE 2010 instruction manual

Sonel GUD-1 user manual

Sonel

Sonel GUD-1 user manual

BW Technologies GasAlertClip Extreme SO2 instruction sheet

BW Technologies

BW Technologies GasAlertClip Extreme SO2 instruction sheet

LEYBOLD PhoeniXL300 dry operating instructions

LEYBOLD

LEYBOLD PhoeniXL300 dry operating instructions

PCB Piezotronics ICP RHM240A01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP RHM240A01 Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.