OVERVIEW OF SETTINGS
Back
More
AIR: WIDTH
AIR: NUMBER
AIR: PRESTIME
AIR: OUTPUT
REDIRECTION
FACTORYRST
More
Back
Back
More
PRESETTINGS
AIR: IMMUNITY*
AIR: FREQ
More
Back
ZIP all parameter settings in zipped format
ID # unique ID-number
ERROR LOG the last 10 errors
AIR: SPOTVIEW view of spot(s) that trigger detection
AIR: C1 ENERG signal amplitude received on curtain 1
AIR: C2 ENERG signal amplitude received on curtain 2
POWERSUPPLY supply voltage at power connector
OPERATINGTIME power duration since first startup
RESET LOG delete all saved errors
RC PASSWORD password for remotre control login
LANGUAGE language of LCD-menu
ADMIN enter code to access admin mode
low normal
> 2.8 m
high
> 2.8 m
standard critical
env.
shopping
street
normal
< 2.8 m
high
< 2.8 m
For conformity to EN 16005 and DIN 18650 at a mounting height
of 2.8 m or more, values 2 and 3 are not allowed.
Sensors mounted close to each other should have a different
frequency.
increased immunity
increased immunitiy + 1 curtain
factory values
service
mode
motion 15 s 30 s 1 min 2 min 5 min 10 min
safety safety
+
opening
0 presence detection on safety input
1 presence detection on safety and opening input
20 min 60 min infinite
service mode = no IR detection during 15 minutes (maintenance).
This value excludes conformity of the door system to EN 16005 and DIN 18650.
restore to factory values
min. value for DIN18650: 1 min
min. value for EN16005: 30 s
BASICADVANCED
DIAGNOSTICS
Always additionally adjust
the arrow position on the
sensor with a screwdriver.
* For conformity to BS 7036 at a mounting height of 2.2 m or more,
values 2 and 3 are not allowed.