Page 2 of 12 75.0050.01 LZR-FLATSCAN W 20230908
TECHNICAL SPECIFICATIONS
Technology LASER scanner, time-of-flight measurement, background analysis
Detection mode Presence
Max. detection range 13’ (diagonal)
(e.g. @ 40’ width, max. height is 16’)
Number of curtains 1
Measurement points 400
Angular resolution 0.27°
Angular coverage 110 °
Min. object size 3⁄4" (depending on the settings and the installation)
Optical characteristics IR LASER, Class 1
wavelength: 905 nm
output power: < 0.1mW
Supply voltage 12 – 24 VDC ±15%
The equipment must be powered by a SELV limited power source ensuring double
insulation between primary voltages and the Equipment supply.
The supply current should be limited to 1.5A.
Power consumption ≤ 2 W
Typ. response time 400 ms
Peak current at power-on 0.8A (max. 20 ms @ 24 VDC)
Cable length 16.4'
Output
max. switching voltage
max. switching current
2 solid state relays (galvanic isolation - polarity free)
42 VAC/VDC
100 mA
Input
max. contact voltage
voltage threshold
1 optocoupler (galvanic isolated - polarity free)
30 V DC (over-voltage protected)
Log. H: >8 VDC
Log. L: <3 VDC
LED signals 1 tri-colored LED: detection/output status
Dimensions 5 3⁄5" (L) × 3 11⁄32" (H) × 1 1⁄3" (D)
(mounting base adds 1⁄2")
Material / Color PC, ASA / black
Tilt angles -2 – 6° (with mounting base)
2 – 10° (without mounting base)
Protection degree IP54
Temperature range -22 – 140 °F if powered
14 – 140 °F without power
Humidity 0 – 95% non-condensing
Vibrations < 2 G
Compliance IEC 60335-2-103
ISO 13849-1 (PL "d"); IEC 61508 (SIL2)
Specifications are subject to changes without prior notice.
All values measured in specific conditions.
1. Laser head initialization
2. Output relay 2 activated (safety) Output relay 1 activated (opening)
Define detection zone Errors
1. Calculation in progress
2. Exit the zone and wait
LED SIGNAL