manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BEA
  6. •
  7. Security Sensor
  8. •
  9. BEA LZR-FLATSCAN SW User manual

BEA LZR-FLATSCAN SW User manual

Other manuals for LZR-FLATSCAN SW

1

This manual suits for next models

10

Other BEA Security Sensor manuals

BEA IXIO-ST INDUSTRIAL User manual

BEA

BEA IXIO-ST INDUSTRIAL User manual

BEA LZR-FLATSCAN 3D SW User manual

BEA

BEA LZR-FLATSCAN 3D SW User manual

BEA LZR FLATSCAN SW User manual

BEA

BEA LZR FLATSCAN SW User manual

BEA G3 User manual

BEA

BEA G3 User manual

BEA LZR-WIDESCAN User manual

BEA

BEA LZR-WIDESCAN User manual

BEA IXIO-ST INDUSTRIAL User manual

BEA

BEA IXIO-ST INDUSTRIAL User manual

BEA IXIO-S CAN User manual

BEA

BEA IXIO-S CAN User manual

BEA LZR- FLATSCAN REV-PZ User manual

BEA

BEA LZR- FLATSCAN REV-PZ User manual

BEA Matrix2-S User manual

BEA

BEA Matrix2-S User manual

BEA DK-12 User manual

BEA

BEA DK-12 User manual

BEA IXIO-SO1 I User manual

BEA

BEA IXIO-SO1 I User manual

BEA FLY User manual

BEA

BEA FLY User manual

BEA LZR-MICROSCAN T User manual

BEA

BEA LZR-MICROSCAN T User manual

BEA FAAC XV1 User manual

BEA

BEA FAAC XV1 User manual

BEA LZR-FLATSCAN SW User manual

BEA

BEA LZR-FLATSCAN SW User manual

BEA IXIO-DT1 User manual

BEA

BEA IXIO-DT1 User manual

BEA IXIO-DT1 User manual

BEA

BEA IXIO-DT1 User manual

BEA WIZARD SMR User manual

BEA

BEA WIZARD SMR User manual

BEA IXIO-ST User manual

BEA

BEA IXIO-ST User manual

BEA EAGLE X-MTF User manual

BEA

BEA EAGLE X-MTF User manual

BEA IXIO-DO1 I User manual

BEA

BEA IXIO-DO1 I User manual

BEA FOCUS 2 User manual

BEA

BEA FOCUS 2 User manual

BEA LZR-MICROSCAN T User manual

BEA

BEA LZR-MICROSCAN T User manual

BEA IXIO-ST User manual

BEA

BEA IXIO-ST User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

75.5959.03 LZR-FLATSCAN SW QG 20200612 Page 1 of 475.5959.03 LZR-FLATSCAN SW QG 20200612 Page 1 of 4
LZR®-FLATSCAN SW
1
!!
ENGLISH
Safety sensor for full- and low-energy automatic swing doors
(US version)
Only trained and
qualified personnel are
recommended to install
and set up the sensor.
Always test for proper
operation before leaving
the premises.
The door control unit
and the header cover
profile must be correctly
grounded.
Visit www.BEAinc.com
for full User’s Guide.
Do not remove the laser
window protection during
construction.
READ BEFORE BEGINNING INSTALLATION & SET-UP
THIS SENSOR IS POWERED BY DC VOLTAGE ONLY.
SEE NEXT PAGE FOR INFORMATION REGARDING USE OF A RECTIFIER.
QUICK GUIDE
MOUNTING
Position mounting base on door
frame and mark and drill holes.
Remove cover, pass cable
through, and secure sensor to
mounting base.
Connect black plug to black
connector.
Tighten lock screw.
Secure mounting base to door
frame.
Drill pass-thru hole in mounting
base and route primary/
secondary cable.
If installing only one sensor (low-energy, approach side), disregard steps associated with the pass-thru cable.
For applications requiring a spacer, first mount spacer to door, and then mount mounting base to spacer.
Page 2 of 4 75.5959.03 LZR-FLATSCAN SW QG 20200612Page 2 of 4 75.5959.03 LZR-FLATSCAN SW QG 20200612
2
3
ON
1 2 3 4
ON
1 2 3 4
X
WIRING
LZR-FLATSCAN SW
+
-
RED
BLACK
BLUE
BROWN
GREEN
WHITE
PURPLE
PURPLE
** Output status when sensor is operational (can be NO or NC)
* If only VAC power is available, a 12V transformer paired with a rectifier must be used.
Do not use a 24V transformer and rectifier as this will cause damage to the product.
POWER SUPPLY
TEST
STOP IMPULSE
Opening side of the door
REOPENING IMPULSE
Closing side of the door
RELAY 1
RELAY 2
**
**
12-24 VDC*
COM
NO/NC
COM
NO/NC
Cut the power cable to the right length, strip the 8 wires,
and connect all wires as indicated above.
DIP SWITCHES
RELAY 1: STOP-impulse on swing side of door RELAY 2: REOPENING-impulse on approach side of door
ON (switch )OFF (switch )
ON OFF
DIP 2 ENVIRONMENT standard critical
Switch to CRITICAL when external disturbances are likely
to cause unwanted detections (min. obj size, immunity and
uncovered zone are increased).
DIP 3 OUTPUT
CONFIGURATION N.O./N.O.1N.C./N.C.1Settings for this DIP switch must be set on the primary sensor
(i.e. the sensor connected to the door control).
DIP 4 PINCH ZONE on off Switch to OFF when the hinge area does not need to be
secured and objects can cause unwanted detections.
After changing a DIP-switch, the orange LED flashes.
A LONG push on the push button confirms the settings.
Afterwards, a number of green flashes (x) indicates the
number of connected sensors (x).
NOTES:
1. RELAY 1 / RELAY 2
ORANGE OFFGREEN
> 3 sec.
Install door loop.
75.5959.03 LZR-FLATSCAN SW QG 20200612 Page 3 of 475.5959.03 LZR-FLATSCAN SW QG 20200612 Page 3 of 4
1. 2. 4.
3.
4
5
B
A
B
A
TEACH-IN
Before launching a teach-in, ensure the following:
• door is closed (use Service Mode if needed − see page 4)
• both relays are connected to door control and primary/secondary cable is connected between sensors
• detection field is free of environmental obstructions, objects, and people
• laser window protector is removed
1. Press the Primary sensor push-button briefly. The LED will begin quickly flashing red/green. When installing the
sensor on a pair of doors, repeat this on the second Primary sensor.
2. When both sensors flash green, position yourself in front of the door and stretch out your arm in front of you.
Make an up-and-down motion at the leading-edge to mark the limit of the detection zones. The LED will flash
red while calculating the width of the door leaves.
3. When the sensors flash green again, remove yourself from the detection field and cycle the door open to allow
the sensors to learn the environment. The sensors will flash red during the closing of the door.
4. Once the door is completely closed again and the LED is off, the teach-in is complete.
NOTE: A teach-in on the primary configures both the primary and the secondary. A teach-in on the secondary only
configures the secondary. In case the primary and secondary sensor are not aligned, first launch a teach-in on
the primary and then on the secondary.
< 1 sec.
Primary
TESTING / ADJUSTING
Check the correct positioning of the
safety fields by walk-testing according
to ANSI 156.10 standards.
If necessary, adjust the tilt angle of the laser curtain by turning the tilt
angle adjustment screw (from 2° to 10°).
Always launch a teach-in and test the correct positioning of the detection fields after making adjustments to
the angle, sensor position, or environment.
Page 4 of 4 75.5959.03 LZR-FLATSCAN SW QG 20200612Page 4 of 4 75.5959.03 LZR-FLATSCAN SW QG 20200612
!
6
Service Mode deactivates all detection fields for 15 minutes and can
be useful during an installation, a mechanical teach-in of the door, or
maintenance work.
• To enter Service Mode, push and hold the button for at least 3
seconds. The LED will turn off.
• To exit Service Mode, push and hold again for at least 3 seconds.
Service Mode is deactivated automatically when a teach-in is launched.
CLOSE SENSOR
Apply cover.
SERVICE MODE
Tech Support & Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore,
BEA, Inc. does not guarantee any use of the sensor outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
©BEA | Original Instructions | PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOR PRINTING