.3
PANEL CONTROLSCONTROLS
FX BOY USER MANUAL CONTROLS
3
2
4
5
8
9
13
18
10
14
19
11
17
20
12
15
21
16
22
6 7
1
1. CARTRIDGE SLOT: Here is where you plug the dierent cards.
Cards are hot-swappable although some pops or little glitches can
occur depending on the cartridge.
Mind cartridge orientation while plugging it. The front side (the one
with the label) should face to the left.
2. “X” CONTROL: Manual control of parameter “X” . The function
of this parameter depends on the inserted cartridge. Please refer to
the Cartridge reference for detailed information on specic cards.
3. “X” CV ATTENUATOR: Controls the amount of CV that is added
(or subtracted) to the “X” Manual control
4. “Y” CONTROL. Manual control of parameter “Y”. The function of
this parameter depends on the inserted cartridge. Please refer to
the Cartridge reference for detailed information on specic cards.
5. “Y” CV ATTENUATOR: Controls the amount of CV that is added
(or subtracted) to the “Y” Manual control
6. MODE SELECTOR: All cartridges have two modes of operation
A and B. What these modes do depends on the cartridge design.
Please refer to the Cartridge reference for detailed information on
specic cards.
7. PEEK METER: Green indicates the presence of a signal at the
module’s output. Red indicates the signal has been clipped.
8. DRY/WET CONTROL: Manual control of the proportion between
the incoming non-processed and the Processed signal.
9-10-11-12. EQ BANDS LEVEL CONTROLS: Manual control to
boost or attenuate the four dierent bands of the equaliser. Each
of the four knobs controls the LO, MID-LOW, MID-HI, and HI bands
respectively. At mid position (12:00) They do not act. Clockwise they
boost and anticlockwise they attenuate.
13-14-15-16. EQ BANDS CV INs:
Control voltage INs for the four
dierent bands of the equaliser. A range of 10 volts is expected and
these voltages are added to the manual controls:
With manual control at the centre, a 10V. bipolar voltage source
(like an LFO ranging +/-5 volt) will move from silence to maximum
volume.
With the manual control at the minimum position (knob full
anticlockwise) an unipolar 10V. the voltage source will move from
silence to maximum volume.
With the manual control knob fully clockwise -10v to 0v will be
accepted.
Other voltages are ignored and don’t represent any danger to the
module.
17. EQ POSITION SWITCH: Manual Control to select if the equalized
is placed before or after the FX Cartridge.
18. AUDIO IN: Modular level audio input. A bipolar signal of around
10 volts is expected at this IN.
19-20. “X” AND “Y” CONTROLS CV INs:
A range of 10 volts is
expected. This voltage is added to the one generated by the manual
control, allowing negative voltages in the same amount the manual
control is positive:
- With the manual DRY/WET knob anticlockwise CV can go from 0 to
10V.
- With the manual DRY/WET knob in the middle CVs go from -5v to 5v.
- With the manual DRY/WET knob fully clockwise -10v to 0v will be
accepted.
Other voltages are ignored and don’t represent any danger to the
module.
21. DRY/WET CV IN:
A range of 10 volts is expected. This voltage is
added to the one generated by the manual control, allowing negative
voltages in the same amount the manual control is positive:
- With the manual DRY/WET knob anticlockwise CV can go from 0 to
10V.
- With the manual DRY/WET knob in the middle CVs go from -5v to
5v.
- With the manual DRY/WET knob fully clockwise -10v to 0v will be
accepted.
Other voltages are ignored and don’t represent any danger to the
module.