RDC104-4_D00402_03_M_DEEN / 08.2023 13
RDC104
RDC104-4 (Switch2, IEC 62955)
Auslösefehlerstrom Idc2 .............................................................DC 6 mA
Ansprechtoleranz Idc2 ....................................................> 0,5…1 x Idc2
Wiederzuschaltwert Idc2 ..........................................................< 2,5 mA
Ansprecheigenzeit tae
DC 6 mA...................................................................................< 480 ms
DC 12 mA.................................................................................< 240 ms
DC 30 mA.................................................................................< 120 ms
DC 60 mA...................................................................................< 70 ms
DC 200 mA.................................................................................< 30 ms
DC 300 mA.................................................................................< 30 ms
Ausgänge Switch1, Switch2, Error
Ausführung ...........................................................Open Collector (NPN)
Schaltvermögen ........................................................... DC 40 V/20 mA*
Meldezeiten bei Modul- und Hardwarefehler
Error.............................................................................................≤ 1,5 s
Switch1........................................................................................≤ 1,5 s
Switch2........................................................................................≤ 1,5 s
PWM-Ausgang
Ausführung .............................................................................. PushPull
HIGH-Pegel ........................................................................3,1…3,5 V*
LOW-Pegel ............................................................................0…0,5 V*
PWM-Frequenz ......................................................................... 8000 Hz
Skalierung
RDC104-4................................................... 0…100 % = DC 0…30 mA
Maximale Strombelastbarkeit ......................................................10 mA
* Der Überspannungsschutz muss kundenseitig sichergestellt werden.
Steuereingang (TEST)
Ausführung .....................................................LOW: aktivierter Zustand
.................................................................... HIGH: deaktivierter Zustand
Schaltschwellen ........................................................HIGH: 3,1… 5,5 V
.......................................................................................LOW: 0… 0,6 V
EMV (IEC 62955)
Einschränkungen ESD: Das Gerät muss in ein den genannten Normen
entsprechendes Gehäuse eingebaut werden.
Einschränkungen leitungsgebundene Störungen:
Maximale Anschlusslänge:.........................................................100 mm
ESD-Festigkeit nach Human Body Model JESD22-A114 ............... .....
............................................................................................ ±2 kV (Luft)
...................................................................................... ±2 kV (Kontakt)
Arbeitstemperatur ............................................................. –30…80 °C
Lagertemperatur ................................................................ –40…85 °C
RDC104-4 (Switch2, IEC 62955)
Rated residual operating current Idc2.........................................DC 6 mA
Response tolerance Idc2 .................................................> 0.5…1 x Idc2
Restart value Idc2 .....................................................................< 2.5 mA
Operating time tae
DC 6 mA...................................................................................< 480 ms
DC 12 mA.................................................................................< 240 ms
DC 30 mA.................................................................................< 120 ms
DC 60 mA...................................................................................< 70 ms
DC 200 mA.................................................................................< 30 ms
DC 300 mA.................................................................................< 30 ms
Outputs Switch1, Switch2, Error
Type ......................................................................Open Collector (NPN)
Switching capacity ....................................................... DC 40 V/20 mA*
Signalling times in the event of module and hardware errors
Error.............................................................................................≤ 1.5 s
Switch1........................................................................................≤ 1.5 s
Switch2........................................................................................≤ 1.5 s
PMW output
Type ......................................................................................... PushPull
HIGH level ..........................................................................3.1…3.5 V*
LOW level ..............................................................................0…0.5 V*
PWM frequency ......................................................................... 8000 Hz
Scaling
RDC104-4................................................... 0…100 % = DC 0…30 mA
Maximum current-carrying ability ...............................................10 mA
* The overvoltage protection must be ensured by the customer.
Control input (TEST)
Type ..................................................................... LOW: activated state
...........................................................................HIGH: deactivated state
Switching thresholds ................................................ HIGH: 3.1… 5.5 V
.......................................................................................LOW: 0… 0.6 V
EMV (IEC 62955)
ESD restrictions: The device must be mounted in an enclosure that
complies with the mentioned standards.
Restrictions line-conducted interferences:
Maximum connection length:....................................................100 mm
ESD immunity acc. to Human Body Model JESD22-A114 ..................
...............................................................................................±2 kV (air)
.......................................................................................±2 kV (contact)
Operating temperature ...................................................... –30…80 °C
Storage temperature .......................................................... –40…85 °C