Bennett Read ONE 114 R User manual

MODEL 114 R
USER GUIDE
COMPLETE HOME CLEANING SYSTEM
ONE


CONGRATULATIONS ON YOUR PURCHASE
1
Thank you for purchasing a BENNETT READ ONE complete home cleaning system.
Your BENNETTT READ ONE incorporates the latest technological
advances in home cleaning systems. It imitates the most powerful forces of nature in a sleek, elegant machine
to ensure that your home is easily and properly cleaned.
Your new BENNETTT READ ONE is manufactured to a high standard of quality
and is backed up by a 24 month guarantee by Tevo.
Should you need any support from us, please visit www.tevo.co.za or call 0861 77 88 88.
PLEASE KEEP THIS USER GUIDE IN A SAFE PLACE
AND READ IT CAREFULLY BEFORE USING YOUR
BENNETTT READ ONE FOR THE FIRST TIME.

IMPORTANT SAFETY INSTRUCTIONS
2
• Your BENNETT READ ONE is for household use only
• Do not immerse any part of the system in water or any other liquids
• Do not operate the system if the appliance or any other part of the system has been dropped or damaged
• Do not disassemble or attempt to repair your BENNETT READ ONE. Return the unit for examination and repair
• Do not use the vacuum to pick up flammable or combustible liquids such as gasoline and do not use it
in areas where they may be present
• Do not use the vacuum to pick up anything that is burning or smoking such as cigarettes, matches or hot ashes
• Use extra care when cleaning on stairs
• Do not use your BENNETT READ ONE without the filters in place
• Do not leave your BENNETT READ ONE plugged in when unattended
• Unplug the electrical cord when not in use and before cleaning or servicing
• Keep loose clothing, hair and all parts of body away from openings and moving parts
• Not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge
• Keep out of reach of children
• Do not allow your BENNETT READ ONE to be used as a toy
• Extra care is necessary when using your BENNETT READ ONE near children, animals or plants
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:
BASIC SAFETY PRECAUTIONS SHOULD BE OBSERVED WHEN
USING YOUR BENNETT READ ONE, INCLUDING THE FOLLOWING:
WARNING
!

3
SAVE THESE INSTRUCTIONS FOR FUTURE USE |FOR HOUSEHOLD USE ONLY
• Do not pull the electrical cord or use the cord as a handle
• Take care to not close doors on the electrical cord and do not pull the cord around sharp edges or corners
• Do not run the machine over it’s own electrical cord
• Do not allow the cord to touch hot surfaces
• Turn off all controls before unplugging from the electrical outlet
• To unplug your BENNETT READ ONE, grasp the plug. Do not unplug by pulling on the electrical cord
• Do not handle the plug or vacuum with wet hands
• Do not operate your BENNETT READ ONE while barefoot
• Do not put any objects into the machine openings
• Do not use your BENNETT READ ONE while any opening is blocked
• Keep your BENNETT READ ONE free of dust, lint, hair or anything else which may reduce airflow
• Keep your work area well lit
• Using improper voltage may result in damage to the motor and possible injury to the user
The correct voltage is listed on the rating label. For operation on 220-240V, 50/60Hz power supply only
• Only use the accessories supplied with your BENNETT READ ONE vacuum
• Only use spare parts recommended by Tevo
• Store your BENNETT READ ONE indoors in a cool, dry area

4
1
2
3
4
6
5
7
9
11
10
30
23
24
25
8
33
12
29

1. Power Switch
2. Pump Switch
3. Spray Hose Connection
4. Flexi Hose Suction Inlet
5. Securing Clips
6. Dirt Collection Tank
7. Motor Unit
8. Detachable Cleaning Solution Tank
9. Carry Handle
10. Post-motor Filter
11. Retractable Power Cable
12. Cleaning Solution Inlet Port
13. Dust Filter Bag (Dry Vacuuming Only)
14. Pre-motor Microparticle Filter (Dry Vacuuming Only)
15. Filter Securing Lock
16. Air flow cut-off float valve
(Wet Vacuuming / Deep Cleaning)
17. Foam Filter (Wet Vacuuming/Deep Cleaning)
18. High-efficiency Multi-floor Surface Vacuum Nozzle
19. Crevice Tool
20. Dusting Brush
21. Hard Floor Wet Spill Tool
22. Adjustable Stainless Steel Extension Wand
23. Spray Hose Securing Clips X 5
24. Variable Suction Control Valve
25. Multi Directional Swivel Handle
26. Cleaning Solution Spray Pipe
27. Detachable Spray Trigger
28. Wire Reinforced Flexi Hose
29. Flexi Hose Inlet Connector
30. Dual Flexi Hose Securing Clips
31. Carpet Deep Cleaning Attachment
32. Upholstery Deep Cleaning Attachment
33. Cleaning Solution Suction Pipe Assembly
34. Cleaning Solution Spray Pipe Extension
5
PRODUCT VIEW
13
16
18
21
26
31
33
23
28
15
10 14
19
22
27
32
34
17
20

INSTALLING THE FILTERS
Open motor unit by releasing both
securing clips (5)
Insert microparticle filter (14) as shown
Secure microparticle filter by inserting and
turning securing lock clockwise (15)
Lift motor unit from dirt collection tank (6)
Replace motor unit on dirt collection tank Secure motor using the securing clips (5)
Attach dust filter bag (13):
Line up filter bag connector with housing on inside of dirt tank
Twist clockwise to lock bag in place
OPERATING INSTRUCTIONS
1
4
2
5 6
3
6

Please read these instructions carefully, failure to operate your BENNETT READ ONE according to
these instructions may cause serious damage to your machine and result in the warranty being void.
Attach flexi hose inlet connector (29) by inserting into flexi hose inlet (4)
Push until you hear both flexi hose securing clips click (30)
Extend wand to desired length by pressing extension catch and pulling free
end of wand
Insert swivel handle (25) into end of stainless steel extension wand (22)
Attach multi floor surface cleaning head (18) to free end of extension wand
until it locks in place. To remove cleaning head, press securing button and
pull attachment away from wand in a simultaneous pulling/twisting motion
IMPORTANT:
7
9
8
10
7

Grasp the plug (11) at the rear of the machine and pull power cable to its full extent (See warnings). DO NOT extend power cable beyond red warning line
on power cable. Insert Plug into the main power supply. Your BENNETT READ ONE is equipped with an automatic cord rewind function. After unplugging the
machine from the wall socket, give the power cable a short sharp tug and then let the automatic cord rewind slowly retract the power cable
Press power on button (1). If machine is on, the LED
light on the switch will be illuminated
11
8
YOU ARE NOW READY TO VACUUM YOUR HOME!
The pump switch must NOT be used in any
vacuuming mode. Use of the pump without water
will lead to PUMP FAILURE. Only switch the pump
on when using your BENNETT READ ONE
for deep cleaning purposes.
When cleaning delicate areas such as blinds or curtains,
the suction strength can be adjusted by sliding the suction
control valve (24) towards you to open it. This will reduce
the suction so that you can vacuum delicate surfaces or
fabrics in your home.
For precise cleaning tasks, remove floor nozzle and replace with desired
attachments (19, 20)
IMPORTANT:
NOTE:

9
YOU ARE NOW READY TO VACUUM YOUR HOME!
It is recommended that all filters be cleaned in an
outside area so that the dirt, dust and dust mites
remain outside in a dustbin.
TIP:
CLEANING THE FILTERS
CLEANING THE DUST FILTER BAG (13)
It is recommended that all filters be checked and cleaned after each use. Following these instructions
will ensure that the life and efficiency of the filters are extended and you will have many years of
exceptional use from your BENNETT READ ONE. Should your filters be in need of replacement,
they can be purchased from the outlet where you originally purchased the BENNETT READ ONE
alternatively, please contact Tevo directly at the numbers listed on the last page of this guide.
IMPORTANT:
Undo securing clips on side of machine (5)
Unzip dust filter bag at the bottom, while
holding over the outside dustbin
1
4
Lift motor unit from dirt collection tank (6)
2 3
5
6
7
Twist filter bag connector
anticlockwise to remove bag
Shake bag while holding the filter bag connector
For larger amounts of dirt, the bag can be shaken a little more vigorously
Once empty, re-zip the bag and return to machine as per “Installing the Filters”
section, refer to page 6, no.3

10
CLEANING THE MICROPARTICLE FILTER (14)
Twist filter securing lock (15) anticlockwise and remove Twist filter securing lock (15) anticlockwise and remove
2 3
1
4
5
6
7
8
The microparticle filter (14) is designed to trap any tiny particles that may escape the filter bag
Gently tap filter on a hard surface like the side of the dustbin
A soft brush can also be used to brush off any visible dirt / dust
For a more thorough clean, use compressed air blown through the centre of the filter
DO NOT use water or any liquid to clean the microparticle filter!
Once clean, replace filter in machine as specified in “Installing the Filters” section, refer to page 6, no.4

11
CLEANING THE POST-MOTOR FILTER (10)
Remove the filter cover (10) from the back of the machine
Replace filter cover, by lining up the bottom tabs with the
holes on the machine
1
7
1
The post-motor filter is designed to be a final trap for any particles of dirt not captured by the previous filters.
This ensures that the air that is returned into your home is as clean and healthy as possible.
2
3
4
6
8
5
Grasp the filter by the filter handle and remove
Remove the high-density foam from the plastic frame
Rinse the high-density foam under running water until clean
Once clean, replace filter assembly in machine as shown on the left
Secure the cover by pushing
until it clips into place
Allow the foam to air-dry completely and insert back into the plastic frame
Your BENNETT READ ONE will give you years and years of exceptional
service. To ensure this, you must regularly check filters, for any blockages
to the air flow in your machine. Routinely inspect the attachments, flexi hose,
extension wand for blockages that may be caused by normal household dirt
such as pet hair, dust, fabric lint, sweet wrappers, etc.
PLEASE REMEMBER:

OPERATING INSTRUCTIONS CONTINUED
12
WET SPILL VACUUMING
Your BENNETT READ ONE is designed to handle wet spills that may occur in your home. These could
include the aftermath of a rain storm, burst geysers or spilled liquids in your home. In the event of a wet
spill in your home, your BENNETT READ ONE can be used to remove liquids from surfaces, as long
as you use it in accordance with the warnings listed at the front of this guide.
Use the following steps to convert your BENNETT READ ONE from dry vacuuming to wet vacuuming.
Do not use your BENNETT READ ONE to vacuum any hazardous liquids. These include but are not limited to: flammable liquids,
boiling liquids, corrosives, acids, oil based liquids, caustic liquids, combustibles, etc.
WARNING:
Undo securing clips (5) on the sides
of the unit
Lift the motor (7) unit from the dirt
collection tank (6)
Remove the microparticle filter by turning filter securing lock (15)
anticlockwise and pulling outwards
1 2
4
3
5
Remove high-efficiency dirt filter bag (13)
by turning the connector anticlockwise
Replace the microparticle filter with the sponge filter (17)

13
Fasten foam filter in-place by inserting and tightening the filter securing lock (15) clockwise
Secure motor using the securing clips
Extend wand to desired length by pressing
extension catch and pulling the free end of wand
Attach flexi-hose inlet connector (29) by inserting
into flexi hose inlet (4). Push until you hear both
flexi hose securing clips click (30)
Attach carpet deep cleaning attachment (31) to the
free end of extension wand until it locks in place.
To remove deep cleaning attachment, press
securing button and pull attachment away from
wand in a simultaneous pulling/twisting motion
Insert swivel handle (25) into end of
stainless steel extension wand (22)
Attach the hard floor wet spill tool (21) to
the carpet deep cleaning attachment by
sliding tool onto the front of the head and
then clipping into place
6
8
11
9
12
10
13
Replace motor unit on dirt collection tank
7

14
When attaching the tool, do not press on the securing
tabs. Gently press in line with tabs on the body of the tool.
There are arrows that indicate where to press.
NOTE:
To remove the hard floor tool, unclip from
the attachment by placing your thumb
beneath the tabs and lifting
14
YOU ARE NOW READY TO SUCK UP THAT WET SPILL!
Grasp the plug (11) at the rear of the machine and pull power cable to its full extent (See warnings).
DO NOT extend power cable beyond red warning line on power cable. Insert Plug into the main power
supply. Your BENNETT READ ONE is equipped with an automatic cord rewind function. After unplugging
the machine from the wall socket, give the power cable a short sharp tug and then let the automatic cord
rewind slowly retract the power cable
Press power on button (1). If machine
is on, the LED light on the switch will
be illuminated
15
The pump switch must NOT be used in any vacuuming mode. Using the pump without water
will lead to PUMP FAILURE. Only switch the pump on when using your BENNETT READ
ONE for deep cleaning purposes.
IMPORTANT:
16
17
Pull cleaning head towards you across wet spill, making sure that the cleaning head is in a slightly raised position so as
to keep the suction head in contact with the hard floor
Removing a wet spill on a carpet follows the same procedure without attaching the hard floor tool

15
YOU ARE NOW READY TO SUCK UP THAT WET SPILL!
1
4
2
5
3
6
Undo securing clips on the sides of the unit (Refer to page 3)
Remove the microparticle filter as described earlier in the guide (Refer tp page 10)
Lift the motor unit from the dirt collection tank
Replace the microparticle filter with the sponge filter (17)
Remove high-efficiency dirt filter bag
Fasten the foam filter by tightening the filter securing lock
OPERATING INSTRUCTIONS CONTINUED
CARPET DEEP CLEANING
BEFORE DEEP CLEANING YOUR CARPETS THERE ARE A FEW PREPARATIONS THAT NEED TO BE TAKEN CARE OF.
SETTING UP YOUR BENNETT READ ONE FOR DEEP CLEANING:
Your BENNETT READ ONE is an exceptional carpet deep cleaner. Deep cleaning of your carpets is an essential
part of your home cleaning habits. Vacuuming your carpets is not enough to keep them clean and free from nasty
household allergens. We recommend that (at least once a month) you deep clean your carpets, to keep them free
from harmful allergens, in addition to removing stubborn stains. By following these recommendations you will create
a healthy home, while keeping your carpets,looking great and also extending their life.
1. Ensure that the carpet you are about to deep clean is thoroughly vacuumed with your BENNETT READ ONE in dry vacuum mode
2. Remove any furniture that may obstruct you during deep cleaning
3. It is advised that deep cleaning takes place as early in the day as possible, to allow ample time for your carpets to dry. Your BENNETT READ ONE will
remove up to 80% of the water used in the deep cleaning process. The remainder of the moisture will dry naturally according to the prevailing weather
conditions. Do not walk on the carpets until they are completely dry. Do not walk on the carpet for at least 4 hours after cleaning
4. When deciding on where to start cleaning a room, always select the corner furthest away from the door to begin and slowly work your way to the
doorway so that you can exit the room without walking on the wet carpet
3
5 6

16
Replace motor unit on dirt collection tank Secure motor using the securing clips
Insert swivel handle (25) into end of stainless
steel extension wand (22)
Extend wand to desired length by pressing
extension catch and pulling free end of wand
Attach carpet deep cleaning attachment
(31) to free end of extension wand until it
locks in place. To remove deep cleaning
attachment, press securing button and pull
attachment away from wand in a simultaneous
pulling/twisting motion
Attach cleaning solution tank (8) to the rear
of the dirt collection tank (pic 46). Ensure
that the tank is properly aligned before
sliding tank in place
Attach flexi-hose inlet connector (29) by
inserting into flexi hose inlet (4). Push until you
hear the both flexi hose securing clips click (30)
7 8
10
13
11 12
9

17
Pour 50ml of appropriate BENNETT READ ONE
cleaning formula into solution tank
Fill tank with cold tap water.
NOTE! DO NOT FILL TANK WITH
WARM OR HOT WATER
Attach cleaning solution spray trigger (27)
to multi directional swivel handle (25)
Attach loose end of cleaning solution pipe to
cleaning solution inlet port (12)
Insert Cleaning solution pipe assembly (33)
into tank (8)
Insert long end of cleaning solution pipe to
spray pipe connection (3) on front of machine
- Push end of spray pipe until you hear a click
- To remove the spray pipe, press the button on
top of connection and remove pipe
Secure spray pipe to outside surface of
flexi-hose (28) using 3 of the securing clips (23)
14
17 18
15
20
16
19
DO NOT use hot/warm water
IMPORTANT:

18
Attach cleaning solution spray pipe extension (34) to loose end of spray pipe
Secure spray pipe to outside surface
of extension wand (28) using 2 of the
securing clips (23)
Attach loose end of spray pipe extension to the carpet deep cleaning attachment (31)
- to attach pipe, insert and turn pipe clock wise 90 degrees (quarter turn)
- to release, turn anticlockwise 90 degrees and remove
21
22 23
YOU ARE NOW READY TO START DEEP CLEANING!
Grasp the plug (11) at the rear of the machine and pull power cable to its full extent (See warnings).
DO NOT extend power cable beyond red warning line on power cable. Insert Plug into the main power
supply. Your BENNETT READ ONE is equipped with an automatic cord rewind function. After unplugging
the machine from the wall socket, give the power cable a short sharp tug and then let the automatic cord
rewind slowly retract the power cable
Press power on button (1). If machine is on,
the led light on the switch will be illuminated.
Press pump on button (2). If pump is on,
the led light on the switch will be illuminated
24 25 POWER SWITCH
PUMP SWITCH
Table of contents
Other Bennett Read Vacuum Cleaner manuals

Bennett Read
Bennett Read WHISPER User manual

Bennett Read
Bennett Read STEALTH User manual

Bennett Read
Bennett Read Tough 35 User manual

Bennett Read
Bennett Read DYNAMITE User manual

Bennett Read
Bennett Read POWER UP PET CJTG00499B-120 User manual

Bennett Read
Bennett Read Power Up Pet Advanced User manual

Bennett Read
Bennett Read MULTI-FORCE User manual

Bennett Read
Bennett Read FORCE 10 User manual

Bennett Read
Bennett Read Tough 18 User manual

Bennett Read
Bennett Read HYDRO 15 User manual