berlinger Fridge-tag 2 L User manual

Fridge-tag®2 L
with internal sensor
OPERATION MANUAL
ENGLISH PAGE 1-34
GEBRAUCHSANWEISUNG
DEUTSCH SEITE 35-68

Content
1) Display explanations
2) State of delivery / Sleep Mode
3) Quality check prior to activation
4.3) Setting the calendar format
4.5) Setting the date
4.6) Setting the time
4.7) Setting the alarm limits (not standard)
4.4) Use of READ and SET
5) Placing the sensor of the Fridge-tag® 2 L
6) Read and change settings /
How to correct setting mistakes
7) Display indication during measurement
9) Reading the History
9.1) Option 1:
Read out day-per-day (30 day history)
9.2) Option 2:
Read out alarms (Alarm-Super-Jump function)
Read out audio Alarm
9.3) Option 3: Read out history via computer
9.4) Temperature record duration
10) Explanation of terms
11) Expiry code explanation
12) Technical specications
13) Important Information
4) Activation process
4.2) Activation
4.1) Overview sequences of activation
6.2) Menu entry
6.1) Overview menu
Page
4
13
18
32
32
33
22
11
17
32
7
4
21
25
27
23
3
7
9
30
6
6
18
19
8) Warning symbol 22
8
9.5)Verycationprocess
27
31
2

English
1) Display explanations
!
1-888
8808 2888
8888
min.
max. °F
°C
Int.SensorSensor
Ext.
1
2
4
3
5
6
7
89
10
11
1
2
3
6
4
7
5
8
9
10
11
OK ( ) or ALARM (X) indicator
Battery power
This icon indicates the remaining capacity of the battery
Temperature display
Daily HIGH / LOW alarm indicator
(showing history of the last 30 days)
Date and text indicator
Additional warning symbol
Indicator of the temperature measurement unit (°F / °C)
Power on indicator (double point is ashing)
Indicator of measured minimum/maximum temperature
Time, duration and text indicator
Indicator of activated sensor:
Int. = internal sensor (inside the Fridge-tag®2 L)
Ext. = external sensor (cable with temperature sensor)
3

2) State of delivery / Sleep Mode
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag®2 L is shipped in its so-called „Sleep
Mode“.
The display (LCD) is blank.
3) Quality check prior to activation
(in Sleep Mode)
The following chart shows which information will be indicated on
the LCD screen upon successive READ button pressing while in
Sleep Mode.
After approx. 60 seconds without any button pressing the Fridge-
tag®2 L goes back into Sleep Mode; the display is blank again.
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Press conti-
nuously READ
to readout
information
4

English
Indication of date and production test
result: 16. September 2015 / PASS
Pressing the READ-button Displayed Information
Display test:
all segments activated
Indication of the current temperature
and which sensor is activated (--.-°C if
is not connected)
Indication of upper alarm settings.
Example shows duration and tempe-
rature limits: 10 hours, >+8°C, high
Indication of con guration ID number
(e.g. 1234)
Indication lower alarm settings: ex-
ample shows duration and temperture
limits: 60 min., <-0.5°C, low
The display is blank again.
*(only indicated if factory preset, otherwise skipped)
5101 2096
P SS4n
80
1H
d r
u
1 000
°C
-05
0L
d r
u
0 001
°C
1st press of READ:
258
°C
Int.Sensor
C1d
0000 0 0
1 342
!
1-888
8808 2888
8888
min.
max.
°F
°C
Int.SensorSensor
Ext.
Battery power:
3 bar = full (>70%)
2 bar = half-full (30-70%)
1 bar* = low (0-30%)
*Device should be replaced.
2nd press of READ:
3rd press of READ:
4th press of READ:
5th press of READ*:
6th press of READ*:
7th press of READ:
8th press of READ:
9th press of READ:
10th press of READ:
0484 13
0051
PCb
0500 00
3491
S
Serial number of the device
PCb number
(manufacturer information only)
CP
4
n
100.0
5

4) Activation process
4.1) Overview sequences of activation
NOTE:
If the activation process has not been completed - after approx.
60 seconds without any button operation - the device will go back
into sleep mode. The activation starts from the beginning.
If you want to read or change settings (e.g. change
°F to °C) after the activation has been comple-
ted, proceed as described in chapter „Read and
Change settings / How to correct setting mistakes“
State of delivery
4.5) Setting the date
4.2) Activation
4.6) Setting the time
4.7) Setting the alarm limits
(only if factory preset otherwise skipped)
4.3) Setting the calendar
format
6

English
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E
110500000010
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
To activate the device press the SET and the READ button
simultaneously for more than 3 seconds.
4.2) Activation
4.3) Setting the calendar format
Option 1:Setting the date format to: dd.mm.yyyy
Press SET to save the
calendar format
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E
110500000010
yyyd y__d
yyyd y__d
Successful activation is visible when the following will appear on
the screen:
7

1
2
Option 2:Setting the date format to: mm.dd.yyyy
Then press SET to
save the calendar
format
Press READ
to change
the calendar
format
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E 110500000010
yyy_ ydd_
After setting the caldendar format, the rst digit of
the date will start fl ashing.
4.4) Instruction for the use of the
READ and the SET button
The SET button is used to save the number. After pressing the
SET button the next digit will start ashing.
The READ button is used to adjust the number. Each time you
press the READ button, the number in the ashing digit will increa-
se by 1. If you press READ more than necessary continue pressing
the READ button until you obtain the desired number.
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Fridge-tag 2 L
Time / Alarm duration
SET
Temperature (min/max)
Alarm state
=OK
=ALARM
READ
®
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E 110500000010
5101 2011
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Fridge-tag 2 L
Time / Alarm duration
SET
Temperature (min/max)
Alarm state
=OK
=ALARM
READ
®
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E 110500000010
5101 2011
Press READ
to adjust the
number
Press SET to con rm
Note: If SET is pressed mistakenly, continue with the set up. In-
structions for changing the mistake are described in chapter „Read
and change settings / How to correct setting mistakes„
8

English
The following example shows how to set the date
to: 16th Sep. 2015 (16.09.2015) in Europe format
1
1
2
2
Press SET
to save
Press SET
to save
Press READ
until „1“
appears as the
rst digit
The rst digit is
ashing:
The second digit
is ashing:
Press READ
until „6“
appears as the
second digit
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Fridge-tag 2 L
Time / Alarm duration
SET
Temperature (min/max)
Alarm state
=OK
=ALARM
READ
®
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E
110500000010
5101 2011
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E
110500000010
5101 2016
4.5) Setting the date
9

Press READ
until „0“
appears as the
third digit
Press READ
until. „9“
appears as the
fourth digit
Press READ
until „1“
appears as the
seventh digit
The fourth digit
is ashing:
The seventh
digit is ashing:
The third digit is
ashing:
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E
110500000010
5101 2096
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E
110500000010
5101 2096
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E
110500000010
5101 2016
1
1
1
2
2
2
Press SET
to save
Press SET
to save
Press SET
to save
Note: The fth and sixth digit is set automatically.
10

English
The date is now set to: 16.09.2015
Press READ
until „2“
appears as the
eighth digit
The eighth digit
is ashing:
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E
110500000010
5101 2096
1
2Press SET
to save
After setting the date, the rst digit of the time will
start fl ashing.
4.6) Setting the time
This example shows how to set the time to: 13:47
Note: The clock function operates as a 24 hour clock
(e.g. 1:47 pm = 13:47).
Press READ
until „1“
appears as the
rst digit
The rst digit is
ashing:
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
5101 2096
1 000
1
2Press SET
to save
11

Press READ
until „3“
appears as the
second digit
The second digit
is ashing:
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
5101 2096
1 003
1
2Press SET
to save
The time is now set to: 13:47
Press READ
until „4“
appears as the
third digit
Press READ
until „7“
appears as the
fourth digit
The third digit is
ashing:
The fourth digit
is ashing:
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
5101 2096
1034
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
5101 2096
1 473
1
1
2
2
Press SET
to save
Press SET
to save
If you want to read or change settings (e.g. change °F to °C) after
the activation has been completed, proceed as described in chapter
„Read and Change settings / How to correct setting mistakes“
12

English
If not, the activation is now completed. Please con-
tinue with chapter 5 Placing the Fridge-tag 2 L.
Note: During max. 1 minute after activation no temperature is
displayed on the screen.
If the device is con gured with self-programmable
alarm limits proceed with the following chapter.
4.7) Setting the alarm limits
(Not standard, only by special order)
The rst digit is ashing:
Press READ to
adjust the number.
Press SET to
con rm the number
1) and 3) Setting the HI & LO alarm duration, they
are completed in the same manner
This adjustment is done in 4 steps:
1) Setting the duration of the upper alarm limit
2) Setting the temperature of the upper alarm limit
3) Setting the duration to the lower alarm limit
4) Setting the temperature of the lower alarm limit
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
1H
d r
u
0 001
1
2
The second digit is ashing:
Press READ to
adjust the number.
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
1H
d r
u
0 002
1
2Press SET to
con rm the number
13

The third digit is ashing:
Press READ to
adjust the number.
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
1H
d r
u
0 002
1
2Press SET to
con rm the number
2) and 4) Setting the HI & LO alarm duration, they
are completed in the same manner
The fourth digit is ashing:
Press READ to
adjust the number.
The duration of the alarm limit is now set.
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
1H
d r
u
0 002
1
2Press SET to
con rm the number
Note: Alarm temperature limits must be no lower than -20 °C
(-4 °F) and no higher than +50 °C (+122 °F).
Note: The temperature measurement unit (°C / °F) can only be
changed after the device is activated in the menu. Go to chapter
„Read and change settings / How to correct setting mistakes“.
First you have to choose the range of the desired temperature limit.
You have the choice between negative and positive temperatures.
In case of a positive limit in Fahrenheit scale you may further choo-
se if the limit shall be equal or above +100 °F. This choice is done
by repetitively pressing READ until the desired range is indicated.
14

English
Instruction for setting a positive temperature limit
between 0 °C / 0 °F and +50 °C / +122 °F
Press SET to adjust the
limit between 0 °C / 0 °F
and +50 °C / +122 °F
Press READ until the
display shows
no fl ashing sign:
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
80
1H
°C
1
2
The next digit can now be set. Press READ until you reach the
desired number. Then press SET to con rm it. Then the next digit
will start ashing. Continue until all digits of the alarm temperature
are set.
Press READ until a
ashing leading „1“
is indicated on the
display:
Press SET to adjust
the limit equal or above
+100 °F
Instruction for setting a positive Fahrenheit tempe-
rature limit equal or above +100 °F
The next digit of the temperature starts ashing. Set the number
and continue until all digits of the alarm temperature are set.
(Important: the maximum Celsius temperature is +50 °C.
This Option is only for temperatures in Fahrenheit)
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
11 80 0
1H
°F
1
2
15

Setting a negative temperature limit below
0 °C / 0°F
Press READ until the
ashing „-“sign is
indicated on the screen:
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
SET
Alarm state
=OK
=ALARM
READ
®
Fridge-tag 2 L
Temperature (min/max)
<2°C
(15min)
>8°C
(30min)
225-0208-001-00E 110500000010
-80
1H
°C
Press SET to set
the limit below
0 °C / 0 °F
1
2
The next digit can now be set. Press READ until you reach the
desired number. Then press SET to con rm it. Then the next digit
will start ashing. Continue until all digits of the alarm temperature
are set.
As soon as the last digit of the lower alarm limit is
con rmed, the activation is completed.
NOTE:
In case the desired temperature limit cannot be con rmed, check
if the temperature is set within the allowed operating temperature
range.
As soon as the parameters of the upper alarm limit
are set, the rst digit of the duration of the lower
alarm limit will start fl ashing. Proceed the same
way as you did with the upper alarm limit.
16

English
5) Placing the Fridge-tag® 2 L
Note: For the right positioning of the Fridge-tag®2 L within the
fridge, please follow the instructions of WHO, CDC or any other
governmental requirements of your country. (For more information
visit www.berlinger.com)
Fridge-tag®2 L with an internal sensor
The activated Fridge-tag®2 L must be placed immediately in its
predetermined location. It is recommended and important to place
the device as close to the supervised goods as possible to ensure
a perfect temperature observation.
Please do not place the device into a Freezer as the screen will
freeze and the battery will lose power prematurely.
17

6.1) Overview menu
6) Read and change settings /
How to correct setting mistakes
6.2) Menu entry
Device activated
6.2.1) Menu: SET DATE
(Change date and / or time)
6.2.2) Menu: READ CONF
(Read alarm congurations)
6.2.4) Menu: SET CONF
(only if factory preset otherwise skipped)
6.2.3) Menu: CELS FAHR
(change alarm congurations)
NOTE:
If you scroll through the menu and you reach the display of the
measuring mode again you need to restart from the begining by
accessing the menu.
In order to adjust more than one setting (e.g. time & Celsius to
Fahrenheit) you must complete each change and return to menu
mode for the 2nd change.
18

English
To change the date format, the date, the time, the temperature
measurement unit or the alarm settings or to read the pre-set alarm
limits please proceed as follows:
The display shows „SET DATE“. Press SET to access the menu
to adjust the date format, date or time settings. Then follow the
steps as described in chapter „Setting the date and time”.
Use the READ button to scroll through the menu.
Use the SET button to access the corresponding menu.
„SET DATE“ is now displayed on the screen.
You have now entered change mode and you may
choose which item you want to change
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Fridge-tag 2 L
Time / Alarm duration
SET
Temperature (min/max)
Alarm state
=OK
=ALARM
READ
®
<2°C
(15min)
>+8°C
(30min)
225-0208-001-00E 110500000010
5101 2011
...then press
READ shortly
...then release both
buttons simultaneously
Press and continue to
hold SET...
6.2.1) Access the menu „SET DATE“
You can access the following 4 menus:
1) SET DATE - change date and/or time settings
2) READ CONF - read the alarm settings
3) CELS FAHR - change to Celsius or Fahrenheit
4) SET CONF - change the alarm settings
(only if factory pre-set)
12
3
Information:
• Time and date adjustments have no effect on the alarm
records.
• Once the device is activated, it cannot be stopped anymore.
6.2) Menu entry to read and change
settings
19

The display shows the menu „SET DATE“. Press READ until
the display shows „READ CONF“. Then Press SET to access
the menu to read the current alarm congurations. First the display
check appears. Then continuously press READ to scroll through
the pre-set alarm parameters.
*Changes of the alarm limits are only possible for devices which
are programmed with this feature.
The display shows the menu „SET DATE“. Press READ until
the display shows „CELS FAHR“. Then Press SET to access the
menu to change the temperature measurement unit. To change the
measurement unit (Celsius / Fahrenheit) press READ until the
display shows the desired sign (°C/°F). Press SET to conrm
the mesurement unit.
The display shows the menu „SET DATE“. Press READ until
the display shows „SET CONF“. Press SET to access the menu
to change the alarm congurations. To change the alarm limits
(duration or temperature) please proceed as described in chapter
„Setting the alarm limits“.
• The number of time adjustments during the same day is un-
limited. Note: After the adjustment has been done, the Fridge-
tag®2 L will be locked for 24 hours after the clock passes
midnight and through the entire next day. (e.g. changes on the
15th Sep., device locked from 00:01 am on the 16th until 00.01
am on the 17th). This is for security reasons.
NOTE: If you experience this problem please wait for the time
on the device to cross over midnight and try again.
6.2.2) Access the menu „READ CONF“
6.2.3) Access the menu „CELS FAHR“
6.2.4)* Access the menu „SET CONF“
20
Other manuals for Fridge-tag 2 L
4
Table of contents
Other berlinger Data Logger manuals

berlinger
berlinger Fridge tag User manual

berlinger
berlinger Q-tag CLm doc User manual

berlinger
berlinger Fridge-tag 2 User manual

berlinger
berlinger Fridge-tag Ultra Low User manual

berlinger
berlinger SmartSystem SHIP L User manual

berlinger
berlinger Fridge-tag 2 L Specification sheet

berlinger
berlinger Fridge-tag 3 User manual

berlinger
berlinger Fridge-tag 2 L Manual

berlinger
berlinger SmartSystem SITE L User manual

berlinger
berlinger Fridge-tag Ultra Low User manual