6) O.P.B
ELEORI(Al',"STAlLAnON
Synchronizing of rebated doors
Synchronizing
The conlrol un,:> "'ust be Slrapped to each other between the
terminals 8, 9, 10, 11, and 12
(see
page 421. The controi unitl
operator lor the "active" door leal IS called "master" and for the
"passive" door lear "slave". The openmg at the "passive" door leaf
IS
deiayed
02
seconds to guarantee ior a correct opening order
without jamming.
Programme selector. opening impulses and presence impulses
These deVices are to be connected 10 the "master" oniy.
"'Push and go"
"'Push and
go"
in the setting
"ON"
guarantees (or a correct
clOSing
order. If one
01
the door leaves's stopped dUring the clOSing move.
ment, both door leaves will
revert
to the open
pOSition
and close
aiter the hold open time set.
Hold open time
The hold open time is controlled by the "master" and must be set to
"0" on the "slave".
Electro-mechanical locking device
Th" device's to be connected to the "master" oniy.
.
...,
Presence detection
The IFD on Ihe "active" door leal ISto be connected to the "mastor"
and the IFD on the "passive" door leal to the "s'ave". (Note :I ,h.
IFD connection ;s made
as
ior a single door, the rebated doors mav
close in the wrong order.) Strap also between the term,nals No, 5 on
Ihe control units, set FS.6 'n "OFF" pOSition and place the IFD
prQgramm~ jumper in pOSItion
"S".
,"
Stop impulses
The stop ,mpuises are to be connected to both control uMits.
Opening speeds. closing speeds and balance force
These functions are ~o be adjus~cd separately ('or both control
unIts.
To make sure that the "passive" door ieai wili close iirst. the clOSing
speed
for
thiS lea; must be ~etfa5ter than Torthe .'.3dlve" door leaf,
Power supply
The
power suppiv for actIvation unll.s.
j
8 V DC on terminals
1
il18
and :or IFD, 24 VDC on te'mlnals 19'20. con be used ;'om both
controi un1t5.