Bestway 58516E User manual

58516E Hmax 1.5 m
OWNER’S MANUAL
bestwaycorp.com/support
Visit Bestway YouTube channel
WE SUGGEST NOT TO RETURN
THE PRODUCT TO THE STORE
QUESTIONS? PROBLEMS?
MISSING PARTS?
For FAQ, Manuals, Videos Or
Spare Parts, Please Visit
bestwaycorp.com/support
V
i
s
i
t
w
w
w
.
b
e
s
t
w
a
y
c
o
r
p
.
c
o
m
/
s
u
p
p
o
r
t
f
o
r
h
e
l
p


SAND FILTER
OWNER’S MANUAL
SAFETY INSTRUCTIONS
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY - do not permit children to
use this product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK - Connect only to a grounding type
receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug is needed, use only identical replacement parts.
WARNING - The unit is provided with a ground-fault circuit-interrupter (GFCI).
To test the GFCI,push the test button. The GFCI should interrupt power. Push the reset
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of an electric shock. Do not use this
pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer
than 5 feet (1.5 m) from the pool.
DO NOT BURY CORD - Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING - To reduce the risk of electric shock, replace damaged cord
immediately.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION: This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being
readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such that it
cannot be readily disassembled for storage. Please examine and verify all sand filter
components are present before use. Notify Bestway at the customer service address listed
on this manual for any damaged or missing parts at the time of purchase.
• THERMALLY PROTECTED MOTOR. CSA ENCLOSURE 3
• FOR USE WITH SWIMMING POOLS ONLY.
•CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK
HAZARD,USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
•WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A
GROUNDING TYPE RECEPTACLE.
•CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO
NOT USE WITH PERMANENTLY-INSTALLED POOLS.
•CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
•CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE
ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE
WITH THE INSTALLATION INSTRUCTIONS.
•WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.
4) Do Not Touch Plug With Wet Hands.
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and
(
2
)
this device
must accept any interference received, including interference that may cause undesired
operation.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
3

SAND FILTER
OWNER’S MANUAL
SAFETY INSTRUCTIONS
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY - do not permit children to
use this product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK - Connect only to a grounding type
receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug is needed, use only identical replacement parts.
WARNING - The unit is provided with a ground-fault circuit-interrupter (GFCI).
To test the GFCI,push the test button. The GFCI should interrupt power. Push the reset
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of an electric shock. Do not use this
pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer
than 5 feet (1.5 m) from the pool.
DO NOT BURY CORD - Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING - To reduce the risk of electric shock, replace damaged cord
immediately.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION: This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being
readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such that it
cannot be readily disassembled for storage. Please examine and verify all sand filter
components are present before use. Notify Bestway at the customer service address listed
on this manual for any damaged or missing parts at the time of purchase.
• THERMALLY PROTECTED MOTOR. CSA ENCLOSURE 3
• FOR USE WITH SWIMMING POOLS ONLY.
•CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK
HAZARD,USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
•WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A
GROUNDING TYPE RECEPTACLE.
•CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO
NOT USE WITH PERMANENTLY-INSTALLED POOLS.
•CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
•CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE
ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE
WITH THE INSTALLATION INSTRUCTIONS.
•WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.
4) Do Not Touch Plug With Wet Hands.
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and
(
2
)
this device
must accept any interference received, including interference that may cause undesired
operation.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
4

5
POOL SUCTION FITTING INSTRUCTIONS
When installing and using this equipment, basic safety precautions shall always be
followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW, AND UNDERSTAND ALL
INSTRUCTIONS AND WARNINGS.
- Any modification that increases the flow rate of the circulation system shall require
re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction
Outlet Fitting Assembly (SOFA) is not exceeded.
- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA
component shall be replaced before bathers are allowed to use the pool.
- Loose cover/grates shall be reattached before bathers are allowed to use the pool.
1. Replace suction fittings every 2 years.
2. The use of adhesives or other attachment methods that prevent access to suction piping
or SOFA components requiring periodic servicing is prohibited.
3. Refer to the following diagram for each SOFA component part instructions:
4. - Any field modification made to a SOFA not authorized by the manufacturer’s installation
instructions shall void the SOFA certification.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified as new SOFA.
- Cover/grates and all other SOFA components shall
be replaced at or before the end of their service life
and that service life begins the month and year in
which a SOFA component is installed with or
without water.
5. Winterizing instructions. Dry the suction fittings
completely, and store the product in a dry room at a
storage temperature of 15
℃ ~ 40 ℃.
6. Use the screwdriver (not included) to disassemble
the suction fitting to clean or service.
- Cover/grate, including fasteners, shall be observed
for damage or tampering each operational day.
- Missing, broken, or cracked cover/grates shall be replaced before bathers are allowed
to use the pool.
- Loose cover/grates and associated components shall be reattached before bathers are
allowed to use the pool.
- SOFA components and fastener receptacles shall be clean and free of debris or
obstructions during installation of cover/grate and fasteners.
- Remember to hand-check cover/grate for snugness to the sump/ frame after
installation.
7. Before using the product, please check the integrity of the head of the suction fitting. If
the product is broken, please do not use it.
8. - All SOFAs shall be installed in accordance with the manufacturer’s installation
instructions.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified to the original SOFA.
- These SOFA-configuration specific flow ratings NOT be exceeded at any time the pool
is open to bathers.
- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the
finished surface of the pool in which the SOFA is installed
9.
Please research and download General Certificate of Conformity through
www.bestwaycorp.com
SAVE THESE INSTRUCTIONS
GFCI WARNING
WARNING: Risk of electric shock. The GFCI must be tested before each use.
WARNING: Do not use the pump if this test fails. For assistance, please visit
the support section on our website, www.bestwaycorp.com.
F4030-03
F4030-02
F4030-01

6
POOL SUCTION FITTING INSTRUCTIONS
When installing and using this equipment, basic safety precautions shall always be
followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW, AND UNDERSTAND ALL
INSTRUCTIONS AND WARNINGS.
- Any modification that increases the flow rate of the circulation system shall require
re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction
Outlet Fitting Assembly (SOFA) is not exceeded.
- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA
component shall be replaced before bathers are allowed to use the pool.
- Loose cover/grates shall be reattached before bathers are allowed to use the pool.
1. Replace suction fittings every 2 years.
2. The use of adhesives or other attachment methods that prevent access to suction piping
or SOFA components requiring periodic servicing is prohibited.
3. Refer to the following diagram for each SOFA component part instructions:
4. - Any field modification made to a SOFA not authorized by the manufacturer’s installation
instructions shall void the SOFA certification.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified as new SOFA.
- Cover/grates and all other SOFA components shall
be replaced at or before the end of their service life
and that service life begins the month and year in
which a SOFA component is installed with or
without water.
5. Winterizing instructions. Dry the suction fittings
completely, and store the product in a dry room at a
storage temperature of 15
℃ ~ 40 ℃.
6. Use the screwdriver (not included) to disassemble
the suction fitting to clean or service.
- Cover/grate, including fasteners, shall be observed
for damage or tampering each operational day.
- Missing, broken, or cracked cover/grates shall be replaced before bathers are allowed
to use the pool.
- Loose cover/grates and associated components shall be reattached before bathers are
allowed to use the pool.
- SOFA components and fastener receptacles shall be clean and free of debris or
obstructions during installation of cover/grate and fasteners.
- Remember to hand-check cover/grate for snugness to the sump/ frame after
installation.
7. Before using the product, please check the integrity of the head of the suction fitting. If
the product is broken, please do not use it.
8. - All SOFAs shall be installed in accordance with the manufacturer’s installation
instructions.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified to the original SOFA.
- These SOFA-configuration specific flow ratings NOT be exceeded at any time the pool
is open to bathers.
- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the
finished surface of the pool in which the SOFA is installed
9.
Please research and download General Certificate of Conformity through
www.bestwaycorp.com
SAVE THESE INSTRUCTIONS
GFCI WARNING
WARNING: Risk of electric shock. The GFCI must be tested before each use.
WARNING: Do not use the pump if this test fails. For assistance, please visit
the support section on our website, www.bestwaycorp.com.
Installation Information label (copy)
Manufacturers name:
GOLEADER INDUSTRIES (JINJHUA) CO., LTD.
Cover part number: F4030
Service life of the cover: 2 Years
Cover flow rating: 28 GPM
Installer need to fill in the balance of information
and give it to the pool owner, to be kept with other
important pool related documents.
Configuration and installed orientation:_________
Location:_______
Installed Date:_________

Filter Diameter
Effective Fiter Area:
Max. Operating Pressure:
Working sand filter pressure:
Max. Water Temperature:
Sand:
Sand Size:
Sand Capacity:
270 mm
0.059 m
2
(0.635 ft
2
)
0.42 Bar (6 PSI)
<0.25 Bar (3.5 PSI)
35˚C
Not included
#20 silica sand, 0.45-0.85 mm
Approximately 8.5 kg
703 mm
311 mm
270 mm
SPECIFICATIONS
PARTS REFERENCE OVERVIEW
P61138ASS16
P03822
P03830
P03823
P03825
P03829
P03824
P6005ASS16
P6124ASS16
P6132ASS16
P03828
P05886
P6614ASS16
P6029ASS16
P6149ASS16
P6660ASS16
P6661ASS16
P6662ASS16
P6663ASS16
P6664ASS16
P6665ASS16
P6019ASS16
P6680ASS16
P61318ASS16
P6783ASS16
P6362ASS16
REF.NO SPARE PART NO.
A B
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
25
24
1
1
1
2
1
3
2
7
10
3
2
1
1
3
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
1
3
2
4
4
1
2
1
1
3
1
1
1
1
1
1
1
2
0
0
1
0
7
8
9
9
9
910 10
25
23
(P61318ASS16)(P6680ASS16)
24
1
2
3
4
5
6
7
8
9
10
12
11
13
14
15
16
17
18
19 21
22
9
20 8
X3
A
BX1 X1
X2
Before assembling the sand filter, take
a few minutes to become familiar with
all the sand filter parts.

(You will need a screwdriver.)
1. Carefully remove all components from the
package and check to ensure nothing is
damaged. If equipment is damaged,
immediately notify the retailer from where the
equipment was purchased.
2. The sand filter should be placed on solid, level
ground, preferably a concrete slab. Position the
sand filter so the Ports and Control Valve are accessible for
operation, servicing and winterizing.
3. The sand filter must be vertically fixed on ground or a certain
pedestal made of wood or concrete before use to prevent the sand
filter from accidental falling. Fully assembled sand filter will exceed
18 kg. The mounting holes should be 8 mm in diameter and spaced
285 mm apart. Use two bolts and nuts with a maximum of 8 mm in
diameter to fasten the sand filter to the pedestal.
LOAD POOL-GRADE FILTER SAND/FLOWCLEAR™ POLYSPHERE.
NOTE:
Use only special pool-grade filter sand, free of all limestone or clay:
#20 Silica sand 0.45-0.85 mm, approximately one 8.5 kg bag should suffice. If you do
not use the recommended size filter sand, filtering performance will be reduced and
the sand filter may damaged, thereby voiding warranty.
NOTE:
To avoid damaging the Skimmer when adding sand, pour some
water into the Bottom Tank to submerse the Skimmer on the Collector Hub.
NOTE: Sand/
Flowclear™ Polysphere
not included.
NOTE:
Use 28 g (0.06 lbs) Flowclear™ Polysphere to replace
1 kg (2.20 lbs) sand.
8
ASSEMBLY
Ø8 mm
285 mm
#20
0.45-0.85 mm
C
C
C
C
MAX.
MIN.

9
CONNECT TO THE POOL
For 1.5 in(38 mm)
connection
A
A
BB
B
A
B
A
B
A
B
B
D
2
3
1
D
Garden hose (not
included)
For Drain, Backwash,
Rinse function
A
B
B
B
P61318ASS16
A
P6680ASS16
A
B
B
1
2
3
4

CONTROL VALVE OVERVIEW
WARNING: To prevent equipment damage and possible injury, always switch off
sand filter before changing the Control Valve function. Changing valve positions
while the pump is running can damage the Control Valve, which may cause
personal injury or property damage.
How to Use the Control Valve:
Press down on the Control Valve handle and
rotate to desired function.
CONTROL VALVE FUNCTIONS
The Control valve is used to select 6 different
filter functions: Filter, Rinse, Circulate, Backwash,
Closed and Drain.
Before switching on, please read the manual carefully.
STOP
B
Filter: This function is used to
filter pool water and should be
positioned here 99% of the time.
Water is pumped through the
sand filter, where it is cleaned
and returned to the pool.
C
C
A
B
Closed: This function stops water
flowing between the sand filter
and the pool.
C
C
A
10
GFCI TEST
OPERATION
RESET
TEST
1 2 3
RESET
TEST
4
RESET
TEST

Drain: This function drains water from
the pool; another filter by pass setting,
water is pumped and deposited out of
Port D, instead of returning it to the
pool.
D
B
C
C
A
D
Backwash: This function is used to
clean the sand bed; water is pumped
down through the Collector Hub,
upwards through the sand bed, and
deposited out of Port D.
B
C
C
A
Circulate: This function circulates
pool water by passing the sand filter;
use this function if the filter is broken
to collect debris in the Debris Screens.
D
B
C
C
A
D
Rinse: This function for initial startup,
cleaning, and sand bed leveling after
Backwash; water is pumped
downwards through the sand bed, up
through the Collector Hub and
deposited out of the valve Port D.
B
C
C
A
NOTE:
• Be sure all provisions for wastewater disposal meet applicable local, state
or national codes. Do not discharge water where it will cause flooding or
damage.
• When the Control Valve is set to the Backwash, Rinse, or Drain position,
water will discharge from Port D on the Control Valve.
• Do not switch on or operate the sand filter with the Control Valve set to the
Closed function or it will seriously damage the sand filter.
• Do not set the Control Valve between two functions, or it will lead to leaking.
• To avoid water leakage, screw the Port D Cap onto the Control Valve Port D
before operating the sand filter.
AIR RELEASE
Press down the control valve handle and wait untill the water flow from
Port D to release the air.
NOTE: It is important to repeat this operation every time you start the
pump after winterizing, maintenance and backwashing the sand bed.
11

1. Now the sand filter is ready for use. Set the
Control Valve to the Filter function.
NOTE: To prevent the risk of electrical shock
dry any excess water from yourself and the
sand filter.
2. Switch on the sand filter to run it.
NOTE: The sand filter has now started its filtering
cycle. Check that water is returning to the pool and take note of the filter
pressure on Pressure Gauge. Generally, the recommended sand filter
pressure is less than 0.25 Bar (3.5 PSI) when it is running.
CAUTION: You must ensure the sand
filter is switched off and unplugged before any
maintenance begins or severe risk of injury or death
exists. As dirt builds up in the sand filter, the pressure
reading on Pressure Gauge will increase. When the
Pressure Gauge is 0.25 Bar (3.5 PSI) or higher, or
water flow to the pool is too low, it is time to clean the
sand. To clean the sand bed, follow all instructions
outlined previously in: Backwash and Rinsing.
NOTE: Pressure gauge is for maintenance purpose only, and the
pressure gauge value is just for reference, it should not be used as a precision
instrument.
NOTE: We recommend you clean the sand bed once a month or less
regularly depending on how often the pool is used. Do not clean the sand too
frequently.
FIRST TIME USE INSTRUCTIONS
Backwash and Rinsing must be performed to prepare the pump for its first use and to wash
the sand.
CAUTION: DO NOT DRY RUN THE SAND FILTER
1. Press down on the Control Valve handle and rotate to the Backwash function.
2. Plug in and run the sand filter for 3-5 minutes, or until the water runs clear.
3. Switch off the sand filter and set the Control Valve to the Rinse function.
4. Switch on the sand filter and run the sand filter for 1 min. This circulates water backwards
through the sand filter and drains water out Port D.
5. Switch off the sand filter. Set the Control Valve to the
Closed function.
6. Top up pool water if required.
IMPORTANT: This procedure removes water
from the pool, which you’ll need to replace.
Switch off the sand filter immediately if water levels near the pool’s Inlet and Outlet valves.
Backwash Rinsing
12
SAND FILTER MAINTENANCE
1.6
0
5
10 15
20
23
1.4
1.2
1
0.8
0.6
0.4
0.2
0
psi
bar

1. Switch off the sand filter and set the Control Valve to the Closed
function.
2. Replace the Debris Screens with Stopper Plugs to prevent water from
escaping.
3. Remove the Strainer Cover by unscrewing it.
4. Take out the Strainer, remove any debris.
5. Put the Strainer back into position. Ensure the hole in the strainer is
aligned.
6. Ensure the Seal Ring is in place. Secure the Strainer Cover back.
7. Remove the Stopper Plugs and insert the Debris Screens.
NOTE: The Strainer must be emptied and cleaned periodically.
A dirty or blocked strainer will reduce the performance of the sand filter.
1. Switch off the sand filter and set Control Valve to the Drain function.
2. Detach the Hose from the pool’s Port A and sand filter Port A and
attach to Port D.
NOTE: Remember to replace the Debris Screen with Stopper
Plug to prevent water from escaping.
3. Switch on the sand filter and press the “RESET” button to run the filter
and remove the pool water.
WARNING: DO NOT DRY RUN THE SAND
FILTER.
13
CLEANING THE STRAINER
STORAGE
LOWERING OR DRAINING POOL WATER
In areas that have freezing winter temperatures, pool equipment must be
winterized to protect against damage. Allowing water to freeze will
damage the sand filter and void warranty.
1. Backwash the sand filter.
2. Drain the pool according to the pool owner’s manual.
3. Disconnect the two Hoses from the pool and the sand filter.
4. Completely pour the sand out of the tank and dry all components.
5. Store the sand filter in a dry location out of child’s reach.

Sand Filter does
not operate
Sand is flowing
to the pool
No water flow
Excessive filter
pressure
Control Valve
leaks from the
port D
Connectors
leaks
Problems Probable Causes Solutions
- GFCI broken
- Sand is too small
- Move the control valve from the
backwash to the filter function
without stop the sand filter
- The level of the sand is too high
- The skimmer was broken
- Stopper plugs were not removed
- Air was not released
- The control valve is set to
Closed
- The strainer is blocked
- Sand filter broken
- Dirty filter
- Calcified sand bed
- Insufficient backwashing
- The pressure gauge was broken
- Control Valve was set between
two functions
- The gasket was broken
- Washer of the connectors not in
place
- Washer of the connectors
broken
- O-ring on the hose connection
was broken
- Loose Hoses
- For assistance, please visit the support section on
our website, www.bestwaycorp.com.
- Recommend 0.45 mm to 0.85 mm #20 silica sand
- Stop the sand filter every time set the control valve
- Check if the level of the sand is between the
marked “MAX” and “ MIN” on the hub
- Replace the skimmer
- Remove the stopper plugs and insert the debris
screens
- Release the air
- Set to filter function
- Clean the strainer
- Call for service
- Backwash
- Inspect sand and change if necessary
- Backwash until effluent runs clear
- Replace the pressure gauge
- Set to one function
- Replace the gasket
- Reposition the washer
- Replace the washer
- Replace the o-ring
- Tighten them
14
TROUBLESHOOTING


For support please visit us at:
bestwaycorp.com/support
©2021 Bestway Inflatables & Material Corp.
All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle Rechte vorbehalten/Tutti i diritti riservati
Trademarks used in some countries under license from/
Marques utilisées dans certains pays sous la licence de/
Marcas comerciales utilizadas en algunos países bajo la licencia de/
Die Warenzeichen werden in einigen Ländern verwendet unter Lizenz der/
Marchi utilizzati in alcuni paesi concessi in licenza a
Bestway Inflatables & Material Corp., Shanghai, China
Manufactured, distributed and represented in the European Union by/
Fabriqués, distribués et représentés dans l’Union Européenne par/Fabricado, distribuido y representado en la Unión Europea por/
Hergestellt, vertrieben und in der Europäischen Union vertreten von/Prodotto, distribuito e rappresentato nell'Unione Europea da
Bestway (Europe) S.r.l., Via Resistenza, 5, 20098 San Giuliano Milanese (Milano), Italy
Distributed in North America by/Distribués en Amérique du Nord par/Distribuido en Norteamérica por
Bestway (USA) Inc., 3411 E. Harbour Drive, Phoenix, Arizona 85034, United States of America
Tel: +86 21 69135588 (For U.S. and Canada)
Distributed in Latin America by/Distribué en Amérique latine par/Distribuido en Latinoamérica por/Distribuído na América Latina por
Bestway Central & South America Ltda, Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile
Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, Unit 2/98-104 Carnarvon St Silverwater, NSW 2128, Australia
Tel: Australia: (+61) 29 0371 388; New Zealand: 0800 142 101
Distributed in United Kingdom by Bestway Corp UK Ltd. 8 Wentworth Road, Heathfield Industrial Estate, Newton Abbot, Devon, TQ12 6TL
Exported by/Exporté par/Exportado por/Exportiert von/Esportato da
Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited
Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong
www.bestwaycorp.com
303021264020
Table of contents
Other Bestway Swimming Pool Pump manuals

Bestway
Bestway 58230 User manual

Bestway
Bestway 58230 User manual

Bestway
Bestway 58647E User manual

Bestway
Bestway FlowClear 58148 User manual

Bestway
Bestway FlowClear 58145 User manual

Bestway
Bestway 58230 User manual

Bestway
Bestway FlowClear 58221 User manual

Bestway
Bestway FLOWCLEAR 58391 User manual

Bestway
Bestway FlowClear 58121 User manual

Bestway
Bestway 58511E User manual
Popular Swimming Pool Pump manuals by other brands

ThermoTec
ThermoTec LCSPI-120 Operation & installation manual

Pentair
Pentair STA-RITE DYNA-PRO Installation and user guide

Gardenic
Gardenic ZSPW400-D instruction manual

OEG
OEG 650 001 082 Installation and operating instructions

Hayward
Hayward MaxFlo VS 500 owner's manual

VERDER
VERDER VP2-HT MF Programming instructions