Read these instructions for use carefully and keep them for later
use, be sure to make them accessible to other users and observe
the information they contain.
WARNING
•
This device may be used by children over the age of eight and by people with
reduced physical, sensory or mental skills or a lack of experience or knowledge,
provided that they are supervised or have been instructed on how to use the
device safely, and are fully aware of the consequent risks of use.
•
Children must not play with the device.
•
Cleaning and user maintenance must not be performed by children unless
supervised.
•
Disconnect the device from the mains supply during cleaning.
•
Clean the device using only the methods specified. Under no circumstances
must liquid enter the fan unit.
•
Do not use any solvent-based cleaning products.
•
If the mains connection cable of this device is damaged, it must be disposed
of. If it cannot be removed, the device must be disposed of.
Dear customer,
Thank you for choosing one of our products. Our name stands for high-quality, thoroughly tested products
for applications in the areas of heat, gentle therapy, blood pressure/diagnosis, weight, massage, beauty, air
and babycare.
With kind regards,
Your Beurer team
Getting to know your device
Humans spend a large proportion of their time indoors. The air indoors is often polluted with dust particles,
pollen, animal hair, odours, harmful gases as well as various bacteria and viruses. The LR 200 air cleaner
cleans the ambient air using a three-layered filter system and an additional integrated ioniser.
The LR 200 air cleaner
•
Filters air with a combi filter (activated carbon filter against harmful gases and unpleasant odours,
HEPA
filter H13
against particles such as bacteria, viruses, mites, pollen and fine dust)
•
has a selectable ioniser
•
Operates quietly with three output levels
•
Has a timer function (two, four or eight hours)
•
has a sleep mode
•
Is suitable for rooms from 9 m²
1)
- 26 m²
2)
,in size,
•
Energy-saving
•
Switches o automatically when the housing cover is removed.
1)
(ANSI/AHAM AC-1 2015)
2)
(NRCC 54013-2011)
ENGLISH

3
1. Included in delivery ................................... 3
2. Signs and symbols .................................... 3
3. Warnings and safety notes ....................... 4
4. Intended use .............................................. 5
5. Device description..................................... 5
6. Initial use .................................................... 6
6.1 Removing the air cleaner....................... 6
6.2 Setting up the air cleaner ...................... 6
7. Usage.......................................................... 7
7.1 Switching on the air cleaner ................. 7
7.2 Fan speed ............................................. 7
7.3 Ioniser/Sleep mode .............................. 7
7.4 Timer function .................................... 7
7.5 Filter change........................................ 8
8. Cleaning and maintenance..................... 9
8.1 Cleaning the filter ................................ 9
8.2 Cleaning the housing........................... 9
8.3 Storage ................................................ 9
9. Accessories and replacement parts .....9
10. What if there are problems? ................. 10
11. Disposal.................................................. 10
12. Technical specifications ....................... 10
13. Warranty / Service ................................. 11
Table of contents
Principle of air cleaning
1. The air cleaner’s fan sucks in the contaminated air.
2. The pre-filter filters out larger particles such as dust, dirt and hairs.
3. Next, the activated carbon filter filters formaldehyde, benzene and other poisonous gases and unpleasant
odours out of the ambient air.
4. Lastly, the HEPA filter filters out small particles such as pollen, bacteria or viruses.
5. The ioniser releases ions into the air. These negative ions bind the smallest particles to themselves due to
the pull of the electric charge. Due to this higher concentration and the formation of larger particles, the
particles are then collected in the ioniser collector or land on the floor, where they can be vacuumed up.
6. The cleaned air is emitted via the air outlet on top of the air cleaner into the ambient air.
The HEPA H13 filter has a filter performance of 99.95%. That means that 99.95% of particles (e.g.
bacteria, viruses and fine dust) can be filtered out.
Contaminated, unfiltered air can have the following eects:
•
Infections and respiratory diseases are more likely to occur
•
Damage to health through harmful gases
1. Included in delivery
•
1x air purifier
•
1x combi filter (activated carbon/HEPA filter class H 13)
•
1x pre-filter
•
1x set of instructions for use
2. Signs and symbols
The following symbols appear in these instructions for use:
WARNING
Warning instruction indicating a risk of injury or
damage to health
Manufacturer
IMPORTANT
Safety note indicating possible damage to the
device/accessory
CE labelling
This product satisfies the requirements of the
applicable European and national directives.
Product information
Note on important information
20
PAP
Dispose of packaging in an environmentally
friendly manner

4
Read the instructions
Disposal in accordance with the Waste Elec-
trical and Electronic Equipment EC Directive
– WEEE
„Geprüfte Sicherheit“ safety mark The device has double protective insulation and
therefore complies with protection class 2.
3. Warnings and safety notes
Read the notes carefully! Non-observance of the following information may result in personal injury or material
damage.
WARNING
Keep packaging material away from children to avoid danger of suocation.
Electric shock
WARNING
As with every electrical device, use this air cleaner carefully and cautiously, in order to avoid hazards due
to electric shock.
• Therefore, observe the following instructions for use:
– do not operate the device at voltages other than those indicated on the device (the type plate is located
on the back of the device),
– never if it or its accessories show visible signs of damage
– not during a thunderstorm
•
In the event of defects or operational faults, switch the device o immediately and disconnect it from
themains socket. Do not pull on the mains cable or on the device to disconnect the plug from the socket.
Never hold or carry the device by the mains cable. Keep the cables away from hot surfaces.
•
Always switch o the device before disconnecting it from the mains.
•
Never disconnect the mains plug with wet or damp hands.
•
Keep the device away from sources of heat as the housing could melt and trigger a fire.
•
Ensure that the openings of the device and the mains cable do not come into contact with water, steam
or other liquids.
•
Do not use the device in close proximity to flammable or explosive gas mixtures.
•
Never reach for a device that has been submerged in water. Disconnect it from the mains plug immediately.
•
Do not use the device if it or its accessories are visibly damaged.
Repairs
WARNING
•
Only specialist personnel may perform repairs on electrical devices. Improper repairs may subject users to
considerable danger. For repairs, please contact Customer Services or an authorised retailer.
•
Do not open the fan unit.
Risk of fire
WARNING
There is a risk of fire if the device is used improperly or these instructions for use are ignored.
Therefore, observe the following instructions for using the air cleaner:
•
Never use underneath a cover, such as a blanket, pillow etc.
•
Never use near petrol or other highly flammable substances.

5
Handling
IMPORTANT
The device must be switched o and disconnected from the mains after every use and before cleaning.
•
Do not place any objects in device openings or in rotating parts. Ensure that the moving parts can move
freely at all times.
•
Do not place any objects on the device.
•
Do not expose the device to high temperatures.
•
Protect the device against sunlight and impacts and do not drop it.
•
Never shake the device.
•
Place the device on a firm and level surface.
4. Intended use
This air cleaner is intended exclusively for cleaning the air indoors. The device is intended for private use.
WARNING
If you suer from severe respiratory or lung disease, consult your doctor before using the air cleaner.
This device must only be used for the purpose for which it was designed and in the manner specified in the
instructions for use. Improper use can be dangerous. The manufacturer is not liable for damage resulting from
improper or careless use.
5. Device description
12
3
4
5
6
7
1. Air outlet
2.
Combi filter (activated carbon filter/
HEPA filter H 13)
Activated carbon filter: To counter
harmful gases and unpleasant smells
HEPA filter H 13: Filters particles such
as bacteria, viruses, mites, pollen and
fine dust
3. Pre-filter
Filters coarse dust and dirt, such as
hairs
4. Control panel
5. Housing cover
6. Housing
7. Air inlet

6
Display and buttons
34
21
ON/OFF FILTER RESET I II III ION SLEEP 2H 4H 8H
1 ON/OFF button
Switches the device on/o
If the light below “Filter reset” is flashing, change
the filter. After changing the filter, hold down the
on/o button to reset the filter change display.
3 Ioniser/Sleep mode
Switching the ioniser or night mode on/o..
2 FAN SPEED button
The air cleaner has three fan speeds: I (low),
II (medium) and III (high).
4 TIMER button
The air cleaner features a timer function that you
can use to determine the number of hours the
air cleaner should run for before it automatically
switches itself o. The air cleaner has three timer
periods: 2H (two hours), 4H (four hours) and 8H
(eight hours).
6. Initial use
6.1 Removing the air purifier
1. Open the cardboard packaging.
2. Remove the device from the top of the box without opening the film bag.
3. Now remove all plastic films. Remove the combi filter from the device (see “Filter change” section) and
take it out of the plastic film. Then re-insert the combi filter into the device.
4. Check the device, mains plug and cable for damage.
6.2 Setting up the air purifier
1. Place the air cleaner on a firm, level surface to prevent vibrations and noise.
IMPORTANT
If you wish to reposition the air cleaner, only carry it by the handle on the rear of the device.
2. Set up the air cleaner in such a way that there is at least 30 cm clearance on all sides.
3. Make sure that the air inlet and air outlet are never blocked.

7
7. Usage
7.1 Switching on the air cleaner
1. Always follow the instructions in chapter “5. Initial use”.
2. Insert the mains plug into the socket. Ensure that the cable does not pose a trip hazard.
3. Press the ON/OFF button ( ) to switch on the air cleaner.
Note
When starting up for the first time, all of the LEDs initially light up. The air cleaner is then set to the lowest
fan speed and the ioniser is activated.
Note
If the “Filter reset” light above the on/o button is flashing, you must replace the combi filter. To do this,
follow the instructions in the “Filter change” section.
7.2 Fan speed
The air cleaner has three fan speeds: I (low), II (medium) and III (high).
•
To switch between the individual fan speeds, press the fan speed button . The fan speed that is currently
set lights up on the control panel.
7.3 Ioniser/Sleep mode
Ioniser Sleep mode Note
1 x press ON OFF „ION“ LED illuminates
2 x press ON ON „ION“ LED illuminates
„Sleep“ LED flashes
3 x press OFF ON „ION“ LED goes out
„Sleep“ LED flashes
4 x press OFF OFF „Sleep“ LED goes out
If sleep mode is activated, all the LEDs in the operating panel automatically switch o after 10 seconds.
To deactivate sleep mode, press any button on the operating panel.
7.4 Timer function
The air cleaner features a timer function that you can use to determine the number of hours the air cleaner
should run for before it automatically switches itself o. The air cleaner has three timer periods: 2H (twohours),
4H (four hours) and 8H (eight hours).
•
To switch between the individual timer periods, press the TIMER button ( ) The TIMER period that is
currently set lights up on the control panel. The air cleaner will now automatically switch o after the set
number of hours has passed.
•
To switch o the timer, repeatedly press the TIMER button ( ), until the light above the TIMER button goes
out. The air cleaner will now clean for an unlimited period.

8
7.5 Filter change
The three-layered filter should be replaced with a new one after 4320 operating hours. After 4320 operating
hours, the red „Filter reset“ LED flashes above the on/o button. To change the filter, proceed as follows:
1
2
1.
Press the ON/OFF button to switch o the air
cleaner, and unplug it from the socket.
2. Remove the housing cover as shown (magnetic
fastening). First detach the magnetic fastening
at the top, and then at the bottom.
3.
Pull out the pre-filter. Now, to pull out the combi
filter, pull carefully on the side tabs.
4.
Insert a new combi filter. To insert the combi filter
correctly, align it with the tabs as shown. Position
the pre-filter above it.
1
2
5. Re-insert the housing cover as shown until you
see and hear it click into place (magnetic fas-
tening). First attach the magnetic fastening at the
bottom, and then at the top.
6.
Insert the mains plug into the socket. Ensure that
the cable does not pose a trip hazard. Press and
hold the on/o button ( ) for five seconds. The
operating hours counter now resets to 0.

9
If you wish to change the combi filter at specific personal intervals (e.g. every six months), there is a
sticker on the upper edge of the combi filter on which you can enter, for example, the date it was inser-
ted or changed.
8. Cleaning and maintenance
WARNING
Before cleaning, always ensure that the mains plug of the air cleaner has been properly
disconnected.
8.1 Cleaning the filter
Regular cleaning of the filter (once a month) is a prerequisite for hygienic and fault-free operation.
•
Clean the three-layered filter using the brush attachment of a vacuum cleaner. To carry out a thorough clean,
pull out the pre-filter and clean the activated carbon filter located behind it and the HEPA filter located at the
rear, also using the brush attachment from a vacuum cleaner. Then replace the pre-filter on the HEPA filter.
Activated carbon filter
HEPA filter H 13
Front Rear
IMPORTANT
The three-layered filter should be changed after 4320 operating hours (see “Filter change” section).
The three-layered filter cannot be washed.
8.2 Cleaning the housing
Clean the housing of the air cleaner with a damp cloth (water or a mild cleaning solution). When cleaning, do
not use any solvents or other aggressive or abrasive cleaning agents, as the surface may become damaged.
8.3 Storage
If you do not plan to use the device for a long period of time, we recommend that you clean it and store it in
the original packaging in a dry environment, ensuring it is not weighed down by additional items.
9. Accessories and replacement parts
Replacement parts and wearing parts are available from the corresponding service address (according to the
service address list). Please state the corresponding order number.
Designation Item number and/or order number
Pre-filter, combi filter (HEPA H 13 filter + activated carbon filter) 686.82

10
10. What if there are problems?
Problem Cause Solution
The air cleaner will not switch on
The housing cover is not cor-
rectly installed.
Ensure that the housing cover is
correctly installed.
The three-layered filter is not
correctly inserted.
Ensure that the three-layered
filter is correctly inserted.
The mains part plug is not
plugged in.
Plug the mains part plug into
asuitable socket.
Insucient passage of air The filters are dirty
Clean the filters (see “Mainte-
nance and storage” section).
The air intake/air outlet is
blocked.
Ensure that the air intake/air
outlet is not blocked.
Air cleaner is very loud There is a foreign body in the air
intake/air outlet.
Remove the foreign body from
the air intake/air outlet.
The filters are clogged. Clean the filters (see “Mainte-
nance and storage” section).
The filters are not correctly
inserted.
Insert the filters correctly.
The air cleaner is positioned on
an uneven surface.
Position the air cleaner on a
level surface.
11. Disposal
For environmental reasons, do not dispose of the device in the household waste at the end of its useful life.
Dispose of the device at a suitable local collection or recycling point. Dispose of the device
inaccordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment).
If you have any questions, please contact the local authorities responsible for waste disposal.
12. Technical specifications
Model LR 200
Mains voltage See type plate on the device
Output 60 W
Dimensions (L x W x H) 275 x 175 x 308 mm
Weight 2.9 kg
Suitable for rooms 9 m² (ANSI/AHAM AC-1 2015) - 26 m² (NRCC 54013-2011)
Permissible operating conditions +5°C to +40°C, ≤ 90% relative humidity (non-condensing)
Protection class Protection class II /
Air flow rate 100 m
3
/h

11
13. Warranty / Service
Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany (hereinafter referred to as “Beurer”) provides a war-
ranty for this product, subject to the requirements below and to the extent described as follows.
The warranty conditions below shall not aect the seller’s statutory warranty obligations which ensue
from the sales agreement with the buyer.
The warranty shall apply without prejudice to any mandatory statutory provisions on liability.
Beurer guarantees the perfect functionality and completeness of this product.
The worldwide warranty period is 3 years, commencing from the purchase of the new, unused product from
the seller.
The warranty only applies to products purchased by the buyer as a consumer and used exclusively for perso-
nal purposes in the context of domestic use.
German law shall apply.
During the warranty period, should this product prove to be incomplete or defective in functionality in accor-
dance with the following provisions, Beurer shall carry out a repair or a replacement delivery free of charge, in
accordance with these warranty conditions.
If the buyer wishes to make a warranty claim, they should approach their local retailer in the first in-
stance: see the attached “International Service” list of service addresses.
The buyer will then receive further information about the processing of the warranty claim, e.g. where they can
send the product and what documentation is required.
A warranty claim shall only be considered if the buyer can provide Beurer, or an authorised Beurer partner, with
- a copy of the invoice/purchase receipt, and
- the original product.
The following are explicitly excluded from this warranty:
- deterioration due to normal use or consumption of the product;
- accessories supplied with this product which are worn out or used up through proper use (e.g. batteries,
rechargeable batteries, cus, seals, electrodes, light sources, attachments and nebuliser accessories);
- products that are used, cleaned, stored or maintained improperly and/or contrary to the provisions of the
instructions for use, as well as products that have been opened, repaired or modified by the buyer or by a
service centre not authorised by Beurer;
- damage that arises during transport between manufacturer and customer, or between service centre and
customer;
- products purchased as seconds or as used goods;
- consequential damage arising from a fault in this product (however, in this case, claims may exist arising
from product liability or other compulsory statutory liability provisions).
Repairs or an exchange in full do not extend the warranty period under any circumstances.

12
686.81_LR200_HEPA_2019-12-27_01_IM1_FITZ Subject to errors and changes
BEURER GmbH • Söflinger Str. 218 • 89077 Ulm (Germany)
www.beurer.com • www.beurer-healthguide.com
Other manuals for LR 200
1
Table of contents
Other Beurer Air Cleaner manuals

Beurer
Beurer LR 300 User manual

Beurer
Beurer LR 401 User manual

Beurer
Beurer LR 330 User manual

Beurer
Beurer LR 400 User manual

Beurer
Beurer LR 210 User manual

Beurer
Beurer LR 330 User manual

Beurer
Beurer LR 200 User manual

Beurer
Beurer LR 220 User manual

Beurer
Beurer LR 210 User manual

Beurer
Beurer LR 330 User manual