BEYES Maxso E600B User manual

Electric Micromotor System (Built-in)
Instruction for Use
Maxso®E600B

2
Maxso E600B is designed to be built into the dentist delivery system and op-
erate as a seamlessly integrated electric motor system. The integrated motor
has an intuitive touchpad interface and is engineered to reduce complexity
and provide increased efciency for optimal treatment results.
For your safety, before operating this product for the rst time, please
read through this manual thoroughly.
1.1 Package includes
• instruction for use –this manual
• user control panel
• control board
• cable
• o-ring
• mounting rack
• screws, 2-pin terminal and 3-way air connector
• motor with seal blocker and cap
• jumper connector
1. Introduction
Content
1. Introduction................................................P2-3
2. Safety and warning....................................P3
3. Installation requirement .............................P4-6
4. Operation...................................................P6-7
5. Maintenance..............................................P8
6. Technical specication ..............................P9
7. Beyes limited warranty statement..............P10-11

3
1.2 Symbol
Following sign may appear in this manual, before or attached les. Some
signs stand for this product’s standard and conformity.
Conformity to Medical Device Directive 93/42/EEC.
Date of manufacturing
Manufacturer
Serial number
Type B
Do not trash
Consult instruction for use
Classication: Class II, Type B
2. Safety and warning
SN
This product should be used for dental operation and to be operated only by
dentist or dental related professional
Warning
• Install this product by authorized third party technician
• Follow the instruction for installation
• Clean and maintain this product following this manual
• Do not drop or crash this product.
• Do not spray oil into this motor.
• Do not use chemical disinfection on motor
• Do not trash this product. Check local available rubbish classied collection
for disposal
Safety
• Do not operate this product in environment mix with air, oxygen and nitric
oxide, ammable anesthetic.
• Do stop the motor before detaching motor or cable

4
Warning
• This module should be installed inside the dental delivery unit by autho-
rized third party technician
• This module requirement AC24V/DC36V power, water and air from the
delivery unit
3.1 Connection inside delivery unit
a. Board to air supply, control panel cable, motor cable and power
cable
3. Installation requirement
Air Control
Power in AC24V/DC36
Control pannel connect
Grey
Red
Black
Yellow
Orange

5
System connect
Unplug the cap
b. Base, air and water tubing connection
a. Control panel
b.Motor
3.2 Connection outside delivery unit
Air in from pedal
Clear: water
Blue: Cooling air
Green: spray air

6
4. Operation
Speed display
Speed rate
REV
Program 1
Lower speed Increase speed
Program 2
Keep press REV
3 seconds to
open or stop
c. Control panel mounting
• Screw panel on the holder
• Install the plastic cap in the left or right side of the delivery unit
• Adjust angle and tighten the holder and cap

7
4.1 Start Motor
• Select the gear ratio 16:1, 1:1 or 1:5 to match the handpiece
Gear ratio Speed range
16:1 100-2,500 RPM
1:1 2,000-40,000 RPM
1:5 10,000-200,000 RPM
• Press REV to select motor direction – green for clockwise, yellow for
counter clockwise
• Press +/- to adjust the speed – the higher number indicate higher speed
• Step on foot paddle to start the motor
• During motor running, light is on and speed can be adjusted
4.2 Stop Motor
To stop the motor, release the foot paddle
Warning
• Do not press REV while motor is running.
• To reverse direction, rst stop the motor.
• Shut down power before detaching motor
4.3 Program Preset
• Select the gear ratio
• Set the speed
• Press and hold P1 or P2 key 3 seconds or more until a beep
• Press P1 or P2 to restore setting when needed
Note: motor direction is not stored

8
5. Maintenance
5.1 Control Panel
Wipe control panel with ethyl alcohol
5.2 Motor
Wipe surface with ethyl alcohol
Caution
• Do not use strong oxidant water or chemical disinfectants to clean motor
• Do not dip or wash motor
• Inspect o-ring – replace if worn or broken
5.3 Sterilization
• Wipe surface with ethyl alcohol
• Put seal blocker and seal cap on the motor
Seal blocker Seal cap
• Put motor in autoclave pouch and seal
• Autoclave 20 min @121°C or 15min @ 132°C
Caution
• Must close the seal blocker and seal cap for autoclave
• Must clean the motor surface before autoclave disinfection

9
Control system: Vector control system
Motor type: DC brushless motor
Speed: 2,000-40,000rpm
Torque: 3.4Ncm
Power input: AC 24V/DC36
Motor size: φ22 x L71mm
Motor weight: 67g
Noise: < 60dB
Light source: LED (white light)
Air supply: ht) >1.5L/min (0.2MPa)
Water supply: >65mL/min (0.2MPa)
Control box size: L130 x W55 x H21mm
Total weight: 632.00g
Environment temperature: -40°C~+70°C
Humidity: 10%~100%
Air pressure: 177~216KPa (1.8~3.0 kgf/cm2)
6. Technical specication

10
7.1 Scope of Warranty
BEYES Dental Canada Inc. (‘BEYES’) warrants to the original retail purchaser
that it will be at BEYES option to repair or replace components of the dental
products manufactured by BEYES (except for components not warranted
under ‘Exclusions’) that are defective in material or workmanship under
normal use and service. BEYES’ obligation under this limited warranty is
limited to the repair or replacement of the applicable components. This limited
warranty shall only apply to defects that are reported to BEYES within the
applicable warranty period and which, upon examination by Beyes, prove
to be defective. This warranty extends only to the rst retail purchaser of a
product and is not transferable or assignable. Replacement components or
products may be used and/or refurbished components or products, provided
they are of like quality and specications as new components or products.
7.2 Applicable Warranty Period
The applicable warranty period, measured from the date of invoice to the
original user, shall be warranted for a period of 25 months.
7.3 Exclusions
This limited warranty does not cover and BEYES shall not be liable for the
following;
1) Defects, damage or other conditions caused, in whole or in part, by misuse,
abuse, negligence, alteration, accident, freight damage, negligent storage,
tampering or failure to seek and obtain repair or replacement in a timely
manner;
2) Products which are not installed, used, and properly cleaned and
maintained as required or recommended in the BEYES ‘Installation’ and/or
‘Installation/User’s Manual’ for the applicable product, including the specied
structural and operational environment conditions and electrical power
requirements;
3) Products considered to be of a consumable or sterile nature;
4) Accessories or parts not manufactured by BEYES;
5) Charges by anyone for adjustments, repairs, replacement parts, installation
or other work performed upon or in connection with such products which are
not expressly authorized in writing in advance by BEYES;
6) Costs and expenses of routine maintenance and cleaning;
7) Representations and warranties made by any person or entity other than
BEYES;
7. Beyes limited warranty statement

11
8) Matching of color, grain or texture except to commercially acceptable
standards;
9) Changes in color caused by natural or articial light;
10) Custom manufactured products;
11) Alterations or modications to the product by any person or entity other
than BEYES;
12) Products that would otherwise be covered under Sections 1 and 2 of
this limited warranty, but are acquired: (i) from a person or entity that is not
BEYES or one of its authorized dealers; or (ii) from a BEYES dealer that is
not authorized to sell the product at issue in the geographic territory where
the purchaser is located, or is not authorized to sell the product at issue within
the medical, animal health or dental market, as the case may be, in which
purchaser intends to use the product.
7.4 Exclusive Remedy; Consequential Damages Disclaimer
BEYES’ OBLIGATION UNDER THIS LIMITED WARRANTY IS THE
REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. BEYES SHALL
NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT, SPECIAL,
INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES
OR DELAYS, INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS
OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER AND
EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND
BENEFITS.
7.5 Warranty Disclaimer
THIS LIMITED WARRANTY IS BEYES' ONLY WARRANTY AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. BEYES
MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR
OR REPLACEMENT OF DEFECTIVE PARTS.

Beyes Dental Canada Inc.
23-595 Middleeld Road
Toronto, Ontario, P1V 3S2
Canada
Tel: 1-855-603-1888
Fax: 1-855-720-1228
Email: [email protected]
Web: www.beyes.ca
Lotus NL B.V.
Koningin Julianaplein 10, Ie Verd,
2595AA, The Hague,
Netherlands
Tel: 3-164-517-1879 (English)
3-162-666-9008 (Dutch)
Email: [email protected]
Web: www.beyes.ca 0197
Printed in Canada
File #: ENI025
Rev.2/01.03.21
Federal law restricts this device to sale by or on the order of a dentist, physician, or any other
practitioner licensed by the law of the states in which he or she practices to use or order the use of this
device. Beyes Dental Canada Inc. is not responsible for any typographical errors. Subjects to technical
changes without notice. *All brands are holders of their respective trademarks.
Table of contents
Other BEYES Medical Equipment manuals
Popular Medical Equipment manuals by other brands

ARJO HUNTLEIGH
ARJO HUNTLEIGH Flowtron Hydroven 3 Garments Instructions for use

Cooper Surgical
Cooper Surgical LEEP System 1000 operating manual

Hillrom
Hillrom Allen A-70801 Instructions for use

B. Braun
B. Braun Aesculap 008349 Instructions for use/Technical description

Contec Medical Systems Co.
Contec Medical Systems Co. ESA0015 user manual

B. Braun
B. Braun Aesculap S4 Instructions for use/Technical description