BIOS Diagnostics PrecisionTemp1 240DI User manual

1 SECOND
EAR THERMOMETER
with
Instruction Manual
Model: 240DI
10.31.2019

240DI
PrecisionTemp 1 Second Ear Thermometer
with Bluetooth®
Instruction Manual
Table of Contents
1 Features
2 Important Safety Instructions
3 Product Diagram
4 How this Thermometer Measures Temperature
5 Setting Date and Time
6 Directions for Use
7 Setting the Beeper
8 Fever Alarm
9 Changing Between Celsius and Fahrenheit
10 Memory Storage
11 Measuring Surface Temperatures
12 Bluetooth®& PrecisionTemp APP
13 Care and Cleaning
14 Battery Replacement
15 Error Messages
16 Technical Specifications
17 5 Year Warranty

PrecisionTemp 1 Second Ear Thermometer
Thank you for purchasing the BIOS Diagnostics PrecisionTemp 1 Second Ear
Thermometer. This is a high quality product incorporating the latest technology
and tested in accordance with international standards. With its unique
technology, this thermometer can provide safe, accurate and reliable readings
with each measurement on people over 2 years of age.
1. Features
Multiple Uses (Wide Range Measurement)
This thermometer offers a wide measurement range feature from 0°C to 100.0°C
(32.0°F to 212.0°F), meaning the unit can be used as an ear thermometer to
measure body temperature or it can be used to measure surface temperature of
the following:
• Milk surface temperature in a baby’s bottle
• Surface temperature of a baby’s bath
• Ambient temperature
Measurement in 1 Second
The innovative infrared technology allows measurement of ear temperature in
only 1 second.
Multiple Reading Recall
Users will be able to recall the last 30 readings when entering the recall mode,
enabling efficient tracking of temperature variations.
Fever Alarm
10 short beeps and a red LCD backlight alerts the patient that he/she may have
a temperature above 37.5°C / 99.5°F.
Illuminated Probe
This thermometer includes a probe LED light which enables the user to find the
correct ear position in the dark. The probe will illuminate for approximately 10
seconds when the thermometer is turned ON.
“Clean Me” Technology
After each temperature measurement “clean me” will flash on the LCD to remind
users to clean the probe. See Care and Cleaning section.
Accurate and Reliable
The unique probe assembly construction incorporates an advanced infrared
sensor, ensuring that each measurement is accurate and reliable.

Free PrecisionTemp App
This thermometer accurately tracks each family member’s temperature and
connects via Bluetooth®to the FREE PrecisionTemp App. The App warns parents
when a fever is rising and when to consult with a medical professional.
Includes normal temperature ranges, measurement techniques and symptoms
parents should watch for.
Please read these instructions carefully before using this thermometer
and keep both in a safe place.
2. Important Safety Instructions
This thermometer may only be used for the purposes described in this booklet.
The manufacturer cannot be held liable for damage caused by incorrect
application.
Never immerse this instrument in water or other liquids. For cleaning
please follow the instructions in the «Care and Cleaning» section.
• Do not use the thermometer if there are any signs of damage. Do not
attempt to repair the thermometer.
• Earwax in the ear canal may cause a lower temperature reading, therefore it
is important to ensure the patient’s ear canal is clean.
• If the measurement result is not consistent with the patient’s finding or
suspiciously low, repeat the measurement every 15 minutes or double check
the result by another core body temperature measurement.
• This thermometer consists of high quality precision parts. Do not drop this
instrument. Protect it from severe impact and shock.
• Keep the thermometer away from direct exposure to the sun and keep it in a
dust-free dry area.
• If the thermometer is not going to be used for a prolonged period the battery
should be removed.
• Battery cover should be installed correctly before use to avoid potential risk
of electric shock.
WARNING:
• Use of this thermometer is not intended as a substitute for consultation with
your physician.
• Ensure that children do not use the instrument unsupervised; some parts are
small enough to be swallowed.
• It is not recommended to use infrared thermometers on children under 2
years of age.
• Infrared thermometers should not be used to manage important health
concerns, and therefore parents should not rely solely on temperature
readings to evaluate the status of your child’s health. If you have any
concerns, consult with your doctor.

Using the unit in the immediate vicinity of mobile phones, microwave appliances
or other devices with strong electromagnetic fields may result in impaired
functioning.
Do not use this device close to strong electromagnetic fields, such as mobile
telephones or radio installations. Keep a distance from such devices when using
this unit.
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
3. Product Diagram
Measuring
sensor
Battery compartment cover
M-button (memory)
Power button
Display
START
button

4. How This Thermometer Measures
Temperature
This thermometer measures infrared energy radiated from the eardrum and the
surrounding tissue. This energy is collected through the lens and converted to
a temperature value. The measured reading obtained directly from the eardrum
(Tympanic Membrane) ensures the most accurate ear temperature.
Measurements taken from the surrounding tissue of the ear canal generate
lower readings and may result in misdiagnosis of fever.
5. Setting The Date And Time
1. When using the Ear Thermometer for the first time please remove the plastic
strip located in the battery compartment.
2. Once the Ear Thermometer is powered up, the year digits will flash on the screen.
Or by pressing and holding the M-button for 3 seconds the year digits will flash.
Press the START button to set the year digits. Press the M-button to confirm.
3. Next the month and day will appear on the screen. Press the START button
to set the month digits. Press the M-button to confirm.
4. Follow the same process to set the day, 12/24 hour mode, hours and minutes.
5. Once you have set the minutes and pressed the M-button the date and time
are set and the time is displayed.
- If no button is pressed for 20 seconds, the thermometer automatically
switches to the measuring screen and you are ready to take a reading.
- To cancel time setup, press the button during time setup. The LCD
will show Date / Time icons with “--:--”. Press the button to start
the measurement. If no further action is taken within 60 seconds, the
thermometer will automatically turn OFF.
6. Directions For Use
PLEASE NOTE: When you turn the thermometer on by
pressing the button, all segments of the screen will be
shown for 1 second and one beep is heard. (Figure 1)
1. When the thermometer is ready to take a reading the °C
or °F icon will be flashing, and you will see -- - on the screen.
2. Straighten the ear canal by gently pulling the middle of the ear back and up.
Figure 1

3. Place the probe firmly into the ear canal, press the START button and keep
the probe in the ear until the thermometer beeps to signal the completion of
the measurement. The probe LED light will turn OFF once the START button
is pressed to take the measurement.
NOTE:
• Always insert the thermometer in the same ear with the same direction and depth.
• Always clean the probe accordingly before and after each use. (See Care and
Cleaning section).
• It is recommended that you measure the temperature 3 times in the same ear.
If the 3 measurements are different, select the highest one. Allow 30 seconds
between each measurement.
• Before measurements, remain in a stable environment and avoid exercise and
bathing for 30 minutes.
• Readings from different measuring sites should not be compared as the
normal body temperature varies by measuring site and time of day, being
highest in the evening and lowest about one hour before waking up.
Normal body temperature ranges:
- Ear: 35.4 – 37.4°C / 95.7 – 99.3°F
- Axillary / Underarm: 34.7 – 37.3°C / 94.5 – 99.1°F
- Oral: 35.5 – 37.5°C / 95.9 – 99.5°F
- Rectal: 36.6 – 38.0°C / 97.9 – 100.4°F
7. Setting The Beeper
1. When the thermometer is OFF, press and hold the button
for 5 seconds to set the beeper.
2. Press the button again to either turn the beeper ON or
OFF. The beeper is activated when the beeper icon is not
crossed out. (Figure 2)
NOTE: If no button is pressed for 5 seconds, the thermometer
automatically switches to measuring mode.
8. Fever Alarm
If the thermometer detects a body temperature greater than 37.5°C / 99.5°F, it
will make 10 short beeping sounds and the LCD will light up RED, indicating a
potential fever.
Figure 2

9. Changing Between Celsius And Fahrenheit
1. To switch the display between °C and °F, simply turn OFF
the unit, press and hold the START button for 5 seconds;
after 5 seconds, the current measurement scale (°C or °F
icon) will flash on the display (Figure 3).
2. Change the measurement scale between °C and °F by
pressing the START button. When the measurement scale
has been chosen, wait for 5 seconds and the unit will
automatically enter the ready for measuring mode.
10 . Memory Storage
This thermometer recalls the last 30 readings.
• Recall mode: Press the M-button to enter Recall
mode when the power is OFF. The memory icon << M
>> will flash. (Figure 4)
• Reading 1 - the last reading: Press and release the
M-button to recall the last reading. Number 1 and a
flashing M are displayed. (Figure 5)
• The last reading displays the date and time of reading
and the temperature taken. (Figure 6)
• Reading 30 - readings in succession: Press and
release the M-button consecutively to recall the last
30 readings in succession. Pressing and releasing the
M-button after the last 30 readings have been recalled
will resume the above sequence from reading 1.
11. Measuring Surface Temperatures
1. Press the button. After one beep sounds, the thermometer is ready for use.
2. Aim the thermometer probe at the desired surface and press the START button.
12. Bluetooth®And PrecisionTemp App
The App will work with the following operating systems:
iOS Support: iPhone 5, iPhone 5s, iPhone 6, iPhone 6p, 6s, 6sP, iOS 7, 7.1, and
up, Bluetooth®4.0
Android: System 4.3 and up, Bluetooth®4.0
This ear thermometer and PrecisionTemp App can work independently of each
other. You do not need to have the App running when you take a measurement
with the ear thermometer. The measurements can be uploaded after you have
taken a temperature.
Figure 4
Figure 5
Figure 6
Figure 3

1. To begin using the free PrecisionTemp App, download and install onto your
smartphone or tablet.
PrecisionTemp
2. Open the PrecisionTemp App. You will need to select what you are using this
App for, Fever or Ovulation temperature monitoring. Select fever.
3. Once selected you will need to register a username and password. The
App will ask you to create an account with an email and password of your
choosing. Once this information is confirmed you can log into the App.
Note: If you have another BIOS Diagnostics Bluetooth®
product and App, you have to create a different username and
password
4. Once in the App, you will be in the “Create a new Profile”
screen. Here is where you can create all your profiles for your
family members. You can enter a profile picture, gender, date
of birth, medical history, medications, and doctor information.
Once you have saved this information it will take you to the
home screen. For your initial set up of the App you have
to complete one profile set up before you can log out of
the App.
5. On the home screen at the top you will see
PrecisionTemp Status: Pull down to pair. Slide your
finger down the screen and the App will start to locate your ear thermometer.
Turn on the ear thermometer; you will now see connecting at the bottom of
the home screen on the App. Once connected, pull down to unpair will now
be on the screen.
6. You can now proceed to take an ear temperature reading. Once you are
finished, the App will update the information under the profile of the person
you are currently in. Here you can also include any symptoms or medications
that you would like to record.
Important: If the time and date are not set on the ear thermometer, when
you take a temperature reading and then download that
reading to the App, the reading will not appear in the History
Measurement screen.
Please Note: When you are taking a measurement, the Bluetooth®signal
will disconnect and then reconnect once finished taking a
measurement and will update to the App.
For more information on the App and how to use it, visit our website
www.biosmedical.com or call our BIOS Medical Hotline: 1-866-536-2289

13. Care And Cleaning
Use an alcohol swab or cotton tissue moistened with alcohol (70% Isopropyl)
to clean and disinfect the thermometer casing and the measuring probe.
Ensure that no liquid enters the interior of the thermometer. Never use abrasive
cleaning agents, thinners or benzene for cleaning and never immerse the
instrument in water or other cleaning liquids. Take care not to scratch the
surface of the probe lens and the display.
14. Battery Replacement
This thermometer is supplied with one lithium battery type, CR2032.
1. The battery needs replacing when only the icon is shown
on the display. (Figure 7)
2. Remove the battery cover by loosening the screw with a
screwdriver and then removing the battery cover by sliding it in the direction
shown. Remove the battery and replace with a new one.
NOTE: Battery cover should be installed correctly before use to avoid potential
risk of electric shock.
15. Error Messages
Display Error
Measured temperature too high:
Displays “ ” when measured temperature is
higher than 100°C / 212°F
Measured temperature too low:
Displays “ ” when measured temperature is
lower than 0°C / 32°F
Ambient temperature too high:
Display “ ” when ambient temperature is higher
than 40.0°C / 104.0°F.
Figure 7

Ambient temperature too low:
Displays “ ” when ambient temperature is lower
than 10.0°C / 50.0°F.
Error function display:
The system has a malfunction
Make sure the probe (sensor) is clean and doesn’t
have any ear wax buildup.
Allow 30 minutes for the thermometer to
acclimate to the environment temperature where
the thermometer is being used before starting
measurements
Blank display:
Check if the battery has been loaded correctly.
Also check polarity of the battery.
Flat battery indication:
If only the “ ” icon is shown on the display, the
battery should be replaced immediately.
16. Technical Specifications
Type PrecisionTemp 1 Second Ear Thermometer with
Bluetooth®240DI
Measurement Range 0°C to 100.0°C/32°F to 212.0°F
Resolution 0.1°C/°F
Measurement
Accuracy
Body mode:
±0.2°C, 35.0 - 42.0°C / ±0.4°F, 95.0 - 107.6°F
±0.3°C, 32.0 - 34.9°C and 42.1 - 43.0°C /
±0.5°F, 89.6 - 94.8°F and 107.8 - 109.4°F
Object mode:
±1.0°C, 0 - 100.0°C / ±2°F, 32.0 - 212°F
Display Liquid Crystal Display, 4 digits plus special icons

Acoustic
• The unit is turned ON and ready for the
measurement: 1 short beep
• Complete the measurement:
1 long beep (1 second) if the reading is less
than 37.5°C/99.5°F, 10 short beeps sound,
if the reading is equal to or greater than
37.5°C/99.5°F
• System error or malfunction: 3 short beep
sounds
Memory • Auto-Display the last measured temperature
• 30 readings recall in the Memory Mode
Backlight
• The display light will be GREEN for 1 second,
when the unit is turned ON.
• The display light will be GREEN for 5 seconds,
when a measurement is completed with a
reading less than 37.5°C/99.5°F
• The display light will be RED for 5 seconds,
when a measurement is completed with a
reading equal to or higher than 37.5°C/99.3°F
Operating
Temperature
10°C to 40°C/50°F to 104°F 15% - 95% relative
maximum humidity
Storage Temperature -25°C to 55°C/-13°F to 131°F
15% - 95% relative maximum humidity
Automatic Switch-
Off
Approximately 1 minute after last measurement
has been taken.
Battery CR2032 Battery 3V - at least 700 measurements
Expected Service
Life 5 years
Dimensions 139 (L) x 39 (W) x 42 (H) mm
Weight 54.5 g (with battery), 51 g (without battery)
Reference to
Standards
EN 12470-5; ASTM E1965; IEC 60601-1; IEC 60601-
1-2 (EMC), IEC 60601-1-11 This device complies
with the requirements of the Medical Device
Directive 93/42/EEC.

Follow Instructions for Use. This document provides important product
operation and safety information. Please read this document thoroughly
before using the device and keep for future reference.
Type BF Applied part
Batteries and electronic devices must be disposed of in accordance with
the locally Applicable regulations, not with domestic waste.
IP22: Protected against solid foreign objects of 12.5 mm diameter and greater.
Protected against vertically falling water drops when the device is tilted up to 15°.
17. 5 Year Warranty
PrecisionTemp 1 Second Ear Thermometer has a 5 year warranty to be free of
manufacturing defects for the life of the original owner. The warranty does not
cover damage from misuse or tampering.
100% Satisfaction Guarantee
If at any time, you are not completely satisfied with the performance of this
device, call our BIOS Medical Hotline and speak with a customer service
representative, who will make arrangements to have the device repaired or
replaced to your full satisfaction.
If you have questions regarding the operation of your thermometer call the
BIOS Medical Hotline: 1-866-536-2289
Should repair be necessary, return the unit with all component pieces. Enclose
proof of purchase and $5.00 for return shipping and insurance. Ship the unit
prepaid and insured (at owners option) to:
Thermor Ltd.
Repair Department
16975 Leslie Street
Newmarket, ON L3Y 9A1
www.biosmedical.com
Email: [email protected]
Please include your name, return address, phone number, and email address.
Thermor will repair or replace (at Thermor’s option) free of charge any parts
necessary to correct the defect in material or workmanship.
Please allow 10 days for repair and return shipping.
Table of contents
Other BIOS Diagnostics Thermometer manuals

BIOS Diagnostics
BIOS Diagnostics 127DU User manual

BIOS Diagnostics
BIOS Diagnostics 194DI User manual

BIOS Diagnostics
BIOS Diagnostics 33302 User manual

BIOS Diagnostics
BIOS Diagnostics BD802 User manual

BIOS Diagnostics
BIOS Diagnostics 240DI User manual

BIOS Diagnostics
BIOS Diagnostics 120DC User manual

BIOS Diagnostics
BIOS Diagnostics 100DC User manual

BIOS Diagnostics
BIOS Diagnostics TH4620 User manual

BIOS Diagnostics
BIOS Diagnostics 282DI User manual

BIOS Diagnostics
BIOS Diagnostics 192DC User manual