BIOS Diagnostics 120DC User manual

BIOS
Diagnostics
™
COMPACT EAR
ThERMOMETER
InsTRuCTIOn
MAnuAl


Table of Contents
1 Important Safety Instructions
2 Product Diagram
3 Directions for Use - Inserting the Battery
4 Ear Mode
5 Fever Alarm
6 Memory Storage
7 Measuring Temperature - Scan Mode
8 Measuring the Room Temperature
9 Changing from Celsius to Fahrenheit
10 Care and Cleaning
11 Battery Replacement
12 Specifications
13 Troubleshooting
14 Two Year Warranty
120DC Compact Ear Thermometer
Instruction Manual
BIOS
Diagnostics
»

Compact Ear Thermometer
120DC
Thank you for purchasing the BIOS Diagnostics™ Compact Ear Thermometer.
The BIOS Diagnostics™ Compact Ear Thermometer is a high quality product
incorporating the latest technology, and tested in accordance with international
standards.
With its unique technology, this thermometer can provide safe, accurate and
reliable readings with each measurement, on people over 2 years of age.
Features:
• Fever alarm
• Probe cover free
• °C/°F switchable
• Fast one second measurement
• Memory recalls last 25 readings
• Storage cover included
• 2 year guarantee
Please read these instructions carefully before using this thermometer and keep
in a safe place.
BIOS
Diagnostics
»

1. IMPORTANT SAFETY INSTRUCTIONS
• Never use the thermometer for purposes other than those for which it
is intended. Please follow the general safety precautions when using
on children.
• Never immerse the BIOS Diagnostics™ Compact Ear Thermometer into
water or other liquids (not waterproof). For cleaning and disinfecting
please follow the instructions in the ‘Care and Cleaning’ section.
• Keep the thermometer away from direct exposure to the sun and keep it
in a dust-free, dry area between -20°C to 50°C (-4°F to 122°F).
• Do not use the thermometer if there are any signs of damage on the
measuring tip or the instrument itself. If damaged, do not attempt to
repair the instrument.
• This BIOS Diagnostics™ Compact Ear Thermometer consists of high
quality precision parts. Do not drop this instrument. Protect it from
severe impact and shock.
WARNING
• Use of this BIOS Diagnostics™ Compact Ear Thermometer is not
intended as a substitute for consultation with your physician.
• Keep the protective storage cover out of the reach of children. Small
pieces may be ingested and present a choking hazard.
• It is not recommended to use infrared thermometers on children under 2
years of age.
• Infrared thermometers should not be used to manage important health

concerns, and therefore, parents should not rely solely on temperature
readings to evaluate the status of your child’s health. If you have any
concerns, consult with your doctor.

2. PRODUCT DIAGRAM

3. DIRECTIONS FOR USE - INSERTING THE BATTERY
1. Slide and remove the battery cover located on the back of the
thermometer.
2. Insert the battery (included) under the metal hook on the top and press
the battery down until you hear a click. Insert the battery with the “+”
side facing up.
3. Once the battery has been inserted, the thermometer will turn on and
beep twice.
4. Replace the battery cover.
4. EAR MODE
1. If the thermometer is not turned on, press the
ON/MEM button. The thermometer is ready for
use after hearing two beeping sounds and the
icon appears on the screen. The unit is now ready
for measuring ear temperature.
2. Gently pull the ear back to straighten the ear canal and carefully insert
the probe snuggly into the ear canal facing the direction of the eardrum
(see “How to Measure Ear Temperature Accurately” below).
R

3. Press and hold the SCAN button until you hear a beeping sound.
Remove the probe from ear and the temperature measurement is
displayed on the screen.
The thermometer will beep two more times for final confirmation of the
measurement. It is now ready to take another measurement.
4. To turn the thermometer off, press and hold the ON/
MEM button for 5 seconds until “OFF” is displayed
on the screen.
Note: If thermometer is left idle for more than 1
minute it will continuously display the room
temperature.
How to Measure Ear Temperature Accurately
• The key to an accurate reading is “straightening” the ear canal to
reach the target (tympanic membrane), as the ear canal is normally
curved.
NOT ACCURATE ACCURATE
OFF
R

How to Straighten the Ear Canal?
• For ages 2 years to adult: Gently pull the
outer ear “up and back” to straighten the
canal. Fully insert the thermometer gently
into the ear.
•It is recommended that you measure the
temperature 3 times in the same ear. If the
3 measurements are different, select the
highest temperature.
•Always insert the thermometer in the same ear with the same
direction and depth.
•Before measurements, remain in a stable environment and avoid
exercise and bathing for 30 minutes prior.
•Always clean the probe accordingly (see Care and Cleaning) after
each use.
5. FEVER ALARM
If the thermometer detects a body temperature greater than 37.5°C / 99.5°F
in the Ear Mode it will make a long beeping sound followed by 3 short beeps,
indicating a potential fever.
Ages 2 years to adult

6. MEMORY STORAGE
When in “ear mode” press ON/MEM to view the stored temperatures. The
stored temperatures are indicated with the . Keep pressing ON/MEM to
scroll through each stored temperature. The thermometer stores 25 sets of
temperatures for ear measurements.
7. MEASURING TEMPERATURE - SCAN MODE
The scan mode allows you to scan surface temperature or room temperature.
This mode shows the actual, unadjusted surface temperatures, which are
different from the body temperature.
1. Power on: Press the ON/MEM button.
2. After the power is on, press and hold the ON/MEM
button and then at the same time press the SCAN
button once for the to appear on the display.
3. Hold the thermometer against the desired surface
to be measured and press the SCAN button to
obtain the real time temperature. If you press and
hold the SCAN button the temperature will be
continuously updated.
R

8. MEASURING THE ROOM TEMPERATURE
The room temperature is continuously displayed when the
unit has been left idle for more than 1 minute. It is shown on
the display screen with the icon.
The temperature will be updated every 15 minutes.
For a more accurate room temperature reading, the
thermometer should be placed on a table and away from direct sunlight or air
conditioner flow.
9. CHANGING FROM CELSIUS TO FAHRENHEIT
1. In ‘Room Temperature’ mode (The LCD only shows the room
temperature and battery icon). Press and hold the SCAN button, then
immediately press and release the ON/MEM button. After 3 seconds
the °C icon will be replaced with the °F icon.
2. Repeat steps to switch back and forth between Celsius and Fahrenheit.

10. CARE AND CLEANING
• After each use, use an alcohol swab or cotton swab moistened
with alcohol (70% Isopropyl) to clean and disinfect the probes and
thermometer casing.
• Keep the unit dry and away from any liquids and direct sunlight.
• Storage temperature range -20°C to 50°C (-4°F to 122°F).
11. BATTERY REPLACEMENT
1. Slide and remove the battery cover located on the back of the
thermometer.
2. Hold the device and insert a small screwdriver or pen to remove the
existing battery.
3. Insert the new battery under the metal hook on the left side and press
the battery down until you hear a click.
4. Replace the battery cover.

12. SPECIFICATIONS
Temperature Measurement Range:
• Ear Mode: 34°C to 42.2°C (93.2°F to 108°F)
• Scan Mode: -22°C to 80°C (-7.6°F to 176°F)
Operating Temperature Range:
• 10°C to 40°C (50°F to 104°F)
Storage Temperature Range:
• -20°C to 50 °C (-4°F to 122°F), RH ≤85 %
• Transportation temperature shall be less than 70 °C, RH ≤95 %
Compliance with the following standards:
• ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part 5:
Performance of infrared ear thermometers (with maximum device).
IEC60601-1-2 (EMC), EN60601-1 (Safety) standards.
Accuracy:
1. For Ear Mode:
• +/- 0.2°C (0.4°F) during 35.5°C to 42°C (95.9°F to 107.6°F)
• +/- 0.3°C (0.5°F) for other range
2. For Scan Mode:
• +/- 0.3°C (0.5°F) during 22°C to 42.2°C (71.6°F to 108°F),
others +/- 4% or +/- 2°C (4°F) whichever is greater.

13. TROUBLESHOOTING
Error Message Problem Solution
Error 5-9, the system is not
functioning properly.
Unload the battery, wait
for 1 minute and repower
it.
Measurement before
device stabilization.
Wait until all the icons
stop flashing.
The device showing a
rapid ambient temperature
change.
Allow the thermometer
to rest in a room for at
least 30 minutes at room
temperature: 10°C and
40°C (50°F and 104°F).
The ambient temperature
is not within the range
between 10°C and 40°C
(50°F and 104°F).

(1) In Ear: Temperature
taken is higher than
42.2°C (108°F).
(2) In Scan Mode:
Temperature taken
is higher than 80°C
(176°F).
Please select the
appropriate mode for
temperature type required.
(1) In Ear: Temperature
taken is lower than 34°C
(93.2°F).
(2) In Scan Mode:
Temperature taken
is lower than - 22°C
(-7.6°F).
R
Device cannot be powered
on to the ready stage.
Change with a new
battery.

TH1015_120DC_BD_IB
090909 ENG
14. TWO YEAR WARRANTY
If this product proves to be defective in material or workmanship within two
years of purchase, it will be repaired or replaced without charge upon receipt of
the unit prepaid with $5.00 to cover handling, packaging and return postage to
the address below. Please include your full name, address and daytime phone
number or email address.
If you have any questions regarding the operation of your thermometer please
call the bilingual Help Line: 1-866-536-2289.
Thermor Ltd.
Repair Department
16975 Leslie Street
Newmarket, ON L3Y 9A1
www.biosexactly.com
Table of contents
Other BIOS Diagnostics Thermometer manuals

BIOS Diagnostics
BIOS Diagnostics 192DC User manual

BIOS Diagnostics
BIOS Diagnostics 100DC User manual

BIOS Diagnostics
BIOS Diagnostics 240DI User manual

BIOS Diagnostics
BIOS Diagnostics PrecisionTemp1 240DI User manual

BIOS Diagnostics
BIOS Diagnostics 194DI User manual

BIOS Diagnostics
BIOS Diagnostics 33302 User manual

BIOS Diagnostics
BIOS Diagnostics TH4620 User manual

BIOS Diagnostics
BIOS Diagnostics BD802 User manual

BIOS Diagnostics
BIOS Diagnostics 282DI User manual

BIOS Diagnostics
BIOS Diagnostics 127DU User manual