PrimeTec B / PrimeScan B
Cable
–
+
–
+
–
+
3 m
–
+
1 2 1 2
1 21 2 1 2
LCD 1 2 1
Radar AIR
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com 1 / 2
PrimeTec B
PrimeScan B
Short guide
ENGLISH
299140D
01/19
PrimeScan B
PrimeTec B
Please mind the original manual!
Electrical connections
Conguration using programming buttons (Operator buttons)
Presetting
Automatic Cong. mode Choose Choose Funct./Parameter Back to choice Back to autom.
Operator buttons
red (Function)
black (Value)
A: Automatic mode
t: Test active
Radar
output on
 AIR
output on
Press shortly both
buttons
simultaneously
Red button:
switch
between Radar, AIR
and general
Black button:
choose
Red button:
Choose
parameter
Black button:
Choose value of the
parameter
Press both
buttons
Press both
buttons
Switches to automatic
mode (A) automatically
after 1 min
General
Radar functions (PrimeTec) OPERATION OF THE BUTTONS1DESCRIPTION
LCD
Field size 1 1 – 5
1
 = Smallest radar eld, ......., * = Medium radar eld, ......,  = Largest radar eld
Direction recognition 2 1 – 2
1 = both directions
* = forward
Cross Trac Optimisation CTO
(Cross Trafc Optimisation) 4 1 – 2
1* = Off
 = On (recommended only at narrow eld)
Door lter 6 1 – 2
1* = Filter off
 = Door and interference lter on (EMV ows, e.g. uorescence tube)
Radar output 7 1 – 2
1* = active
= passive
The Slow Motion Detection (SMD) is a factory setting. The SMD recognises slow motions after the detecor has been activated.
AIR functions
(PrimeTec / PrimeScan) OPERATION OF THE BUTTONS1DESCRIPTION
Function Value LCD
Set sensitivity 1 1 – 5
2 = high sensitivity (acc. to EN 16005 ≤ 3m, only indoors)
 = medium sensitivity (acc. to EN 16005 ≤ 3m)  = low sensitivity (acc. to EN 16005 ≤ 2.3m)
* = normal sensitivity (acc. to EN 16005 ≤ 2.6m)  = very low sensitivity
Set teach-in time 2 1 – 5
2= 10 s * = 30 s (acc. to EN 16005)  = 60 s (acc. to DIN 18650 + AS 5007)
 = 180 s = 15 min
AIR output contact logic 31 – 4
2 = active (NO)
no detection
contact open
* = passiv (NC)
no detection
contact closed
Series connection
Settings
Master  ➔ Slave 
Master  ➔ Slave 
Wiring: See series connection diagram:
reglomat.bircher.com/en/
products-technologies/primefamily-b
AIR output 4 1 – 2
2* = On
= Off (AIR is going to be reactivated automatically after 15 minutes)
General functions
(PrimeTec / PrimeScan)   OPERATION OF THE BUTTONS1DESCRIPTION
Function Value LCD
Reset
+
Press both buttons 8
seconds Initialisaiton and teaching of the background
Presetting (After presetting and leaving
cong. a reset will be done automatically) 1
1 – 8
Press value for
1 second
to change the
presetting
12= Standard, = footpath, = home for the aged, = wind screen,
= high door, = narrow door, = wide door,
= factory settings
For all values set,
parameter 0 is displayed
Combined outputs
activated / not activated 2 1 – 2
12= activated (radar and AIR actuate the radar output)
* = not activated
AIR-frequency (In the case of
overlapping AIR elds consider the
addressing order: ➔odd nr. 1 ➔even nr. 2
➔ odd nr. 3)
31 – 6
2
1* = Frequency 1  = Frequency 3 = Frequency 5
 = Frequency 2 = Frequency 4 = Frequency 6
In the case of overlapping AIR elds consider the frequency order: ➔odd number ➔even number ➔odd number 
1 Press both buttons shortly for conguration mode / * Factory setting
Standard Foot path Home for the aged Wind screen High door Narrow door Wide door Factory settings
Radar eld size 33324253
Field geometry2wide narrow wide wide wide narrow wide wide
Cross Trac Optimisation 12111111
2Field geometry has to be set manually
Power Supply
1 white white
2 brown brown
3 green green
4 yellow
6 pink pink
5 grey grey
yellow
7 blue blue
8 red red
Radar output
Test
11.5 – 32 VDC
Controller
Radar
Test
AIR
AIR output
0°
+ 1 … + 7°
– 1 … – 5°
–
+
5-10 cm
–
+
–
+
–
–
+
–
+
– +
1m
2m
3m
1m
2m
0m
0m
1m
2m
3m
4m
2.2 m


90°
1m
2m
3m
1m
2m
0m
0m
1m
2m
3m
4m
2.2 m
1.
2.
*
A B C DA B C DA B C D A B C DA B C D
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com 2 / 2
Initialisation
Remove all objects that do not form part of the usual door system environment from the
door area BEFORE switching on the power supply. Ensure that no people are in the door
area, otherwise correct startup will not be possible.
The alternate ashing shows the initialisation (teaching) of the detector. (Duration 20 - 25 seconds).
During startup, the rmware version FXXX is displayed.
Following initialisation, the red/green LED only illuminates when a detection has occurred.
The door system is now operational at this point. If any further settings are required, proceed as described in the following sections.
red LED green LED
Mechanical ne tuning
AIR eld (PrimeTec / PrimeScan)
Settings of the inclination angle on the
adjustment screw:
Inclination:
– 5° ... +7° continuously adjustable
Radar eld (PrimeTec)
Manual settings of the
inclination angle
0° ... +90° in 5° steps
Manual settings of the
pivot angle
– 20° ... +20° in 5° steps
Wide radar eld turn 90° Narrow radar eld
Inclination angle: 35° Inclination angle: 35°
min. = 0.5 m x 0.25 m (WxD)
max. = 4 m x 2 m (WxD)
min. = 0.16 m x 0.8 m (WxD)
max. = 2 m x 4 m (WxD)
Setting the AIR eld width (PrimeTec / PrimeScan)
A, D covered A, C, D covered C, D covered A, B, D covered A, B covered
Field width: 1 x 0.2 m
Field width: 0.5 x 0.2 m
Field width: 1.2 x 0.2 m
Field width: 0.5 x 0.2 m
Field width: 1.2 x 0.2 m
The width of the AIR eld can be set using the click-in plastic cover in front of the detector’s lens.
1. Slide
2. Push & click!
Possible settings (Dimensions at 2.2 m mounting hight):
Detector without cover:
All light beams are active
Field width:
2.3 m x 0.2 m
at 2.2 m

This manual suits for next models

1

Other Bircher Security Sensor manuals

Bircher Herkules 2 User manual

Bircher

Bircher Herkules 2 User manual

Bircher TopScan G3 User manual

Bircher

Bircher TopScan G3 User manual

Bircher PrimeMotion C User manual

Bircher

Bircher PrimeMotion C User manual

Bircher PIR 20 User manual

Bircher

Bircher PIR 20 User manual

Bircher Merkur 2 ES.SM Series User manual

Bircher

Bircher Merkur 2 ES.SM Series User manual

Popular Security Sensor manuals by other brands

B.E.G. LUXOMAT PD4-BMS Mounting instructions

B.E.G.

B.E.G. LUXOMAT PD4-BMS Mounting instructions

Potter PAD300-4DB quick start guide

Potter

Potter PAD300-4DB quick start guide

Pepperl+Fuchs OBT300-R100-2EP-IO-L manual

Pepperl+Fuchs

Pepperl+Fuchs OBT300-R100-2EP-IO-L manual

Thermo Scientific RadEye SPRD quick start guide

Thermo Scientific

Thermo Scientific RadEye SPRD quick start guide

Alarmtech MC 470 instruction manual

Alarmtech

Alarmtech MC 470 instruction manual

CS Instruments LD 450 instruction manual

CS Instruments

CS Instruments LD 450 instruction manual

Berker 7524 10 04 installation instructions

Berker

Berker 7524 10 04 installation instructions

General Monitors FL3112 manual

General Monitors

General Monitors FL3112 manual

Optex Boundary Gard BX-80NR installation instructions

Optex

Optex Boundary Gard BX-80NR installation instructions

Orno OR-GB-431 Operating and installation instructions

Orno

Orno OR-GB-431 Operating and installation instructions

REV Ritter LED TRIANGLE SENSOR Assembly and operating instructions

REV Ritter

REV Ritter LED TRIANGLE SENSOR Assembly and operating instructions

hyfire Taurus Series quick start guide

hyfire

hyfire Taurus Series quick start guide

Philips LCN3110/05 installation instructions

Philips

Philips LCN3110/05 installation instructions

TELECO AUTOMATION TVTXS868A02 instruction manual

TELECO AUTOMATION

TELECO AUTOMATION TVTXS868A02 instruction manual

Gewiss GW 90787 Technical manual

Gewiss

Gewiss GW 90787 Technical manual

mySmart MWS6-PRM Product guide

mySmart

mySmart MWS6-PRM Product guide

Potter PAD300-CD quick start guide

Potter

Potter PAD300-CD quick start guide

Monacor PIR-100D manual

Monacor

Monacor PIR-100D manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.