English | 27
Bosch Power Tools 2 609 141 026 | (1.7.13)
If the “digital vial” function is activated in the basic settings,
the grade value is also displayed in the other measuring func-
tions in line dof display 1.
Timer Function
The timer function is helpful, when, for example, movements
of the measuring tool during measuring are to be prevented.
To activate the timer function, press and hold button 6until
the indicator appears in the display.
The time period from the actuation until the measurement
takesplaceisdisplayed inthe measured-valuelinea.Thetime
period canbe adjusted between 1 s and 60 s by pressing the
plus button 11 or the minus button5.
The measurement takes place automati-
cally after the set time period has
elapsed.
The timer function can also be used for
distance measurements within other
measuring modes (e.g. area/surface
measurement). Adding and subtracting measuring results as
well as continuous measurements are not possible.
List of the last Measuring Values
The measuring tool stores the last 50 measuring values and
their calculations, and displays them in reverse order (last
measured value first).
To recall the storedmeasurements, press
button 7. The result of the last measure-
ment is indicated on the display, along
with the indicator for the measured-value
list eand the memory location of the dis-
played measurements.
When no further measurements are stored after pressing but-
ton 7again, the measuring tool switches back to the last
measuring function. To exit the measured-value list,press
one of the measuring-mode buttons.
To continuously save the currently displayed length measure-
ment value as a constant, press and hold the measured-value
list button 7until “CST” is indicated on the display. A meas-
ured-value list entry cannot be subsequently saved as a con-
stant.
Tousealengthmeasurement valuein ameasuringmode(e. g.
area/surface measurement), press the measured-value list
button7, selectthe desiredentryandconfirmbypressingthe
result button 6.
Deleting Measured Values
Brieflypressingbutton4deletesthelast individualmeasuring
value determined in any measuring function. Briefly pressing
thebuttonrepeatedlydeletesthe individualmeasuringvalues
in reverse order.
To delete the currently displayed measured-value list entry,
briefly press button 4. To delete the complete measured-val-
ue list and the constant “CST”, press and hold the measured-
valuelist button 7and at the same time briefly press button 4.
In wall surface measurement mode, briefly pressing button 4
the first time deletes the last individually measured value;
pressing the button a second time deletes all lengths BX, and
pressing the button a third time deletes the room height A.
Adding Measured Values
Toaddmeasuredvalues,firstlycarryout anymeasurementor
select an entry from the measured-value list. Then press the
plusbutton 11. For confirmation,“+” appears on the display.
Thencarryout a secondmeasurementor select another entry
from the measured-value list.
Tocall up the sum of bothmeasurements,
press the result button 6. The calculation
isindicated inthemeasured-valuelinesa,
and the sum in the result line c.
After calculation of the sum, further
measured values or measured-value list
entries can be added to this result when
pressing the plus button 11 prior to each measurement.
Pressing the result button 6ends the addition.
Notes on the addition:
– Mixed length, area and volume values cannot be added to-
gether. For example, when alength and area value are add-
ed, “ERROR” briefly appears on the display after pressing
the result button 6. Afterwards,the measuring tool switch-
es back to the last active measuring mode.
– For each calculation, the result of one measurement is
added (e.g. the volume value); for continuous measure-
ments, this would be the displayed measured value in re-
sult linec.Theadditionofindividual measured values from
the measured-value lines ais not possible.
Subtracting Measured Values
To subtract measuring values, press mi-
nus button 5; For confirmation, “–” is in-
dicated on the display. The further proce-
dure is analog to “Adding Measured
Values”.
Data Transmission to other Devices
The measuring tool is equipped with a Bluetooth® module,
which enables data transmission via radio technology to cer-
tain mobile terminals/devices with a Bluetooth® interface
(e.g., smartphones, tablets).
For information on the necessary system requirements for a
Bluetooth® connection, please refer to the Bosch website at
www.bosch-pt.de.
For data transmission via Bluetooth®, time delays between
mobile terminal/device and measuring tool may occur. This
can be possible due to the distance between both devices or
the object being measured.
Datatransmissionto certain otherdevices with USB interface
is possible via the measuring tool’s micro USB port (e.g. to
computers, notebooks). In USB operation, the charging dura-
tion ncan be significantly prolonged during data transmis-
sion.
OBJ_BUCH-1956-002.book Page 27 Monday, July 1, 2013 11:28 AM