manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bosch
  6. •
  7. Security Sensor
  8. •
  9. Bosch Photobeam 3000 ISC-FPB1-W30DS User manual

Bosch Photobeam 3000 ISC-FPB1-W30DS User manual

© 2014 Bosch Security Systems, Inc. F.01U.282.674 | 05 | 2014.10 | 1
en Installation Guide
CAUTION!
Ensure that the pole mount installation is secure and stable. Failure to do so may result
in personal injury, or damage the device.
Figure 3.1: Terminal strip overview and wiring example.
Figure 1.2 Transmitter/receiver dimensions
Figure 2.1: Fastening the mounting plate and removing the cover.
Callout - Description
1 - Cover 7 - Optical Alignment scope
2 - Wiring terminals 8 - Mounting plate
3 - LED indicators 9 - Wire entry
4 - Tamper switch 10 - Cover securing screws
5 - Vertical adjustment screw 11 - Device securing screws
6 - Twin lens
Figure 1.1 Transmitter and receiver overview
The ISC-FPB1-W30DS, ISC-FPB1-W60DS, and ISC-FPB1-W90DS are
dual-beam photoelectric detectors designed for indoor and outdoor
applications. Consisting of a separate transmitter and receiver, they
are designed to activate an alarm when an intruder passes within the
direct line of sight between the transmitter and receiver.
1 Overview
2 Installation
2.1 Wall mount installation
1. Remove the cover and the mounting plate. Refer to Figure 2.1.
2. Fasten the mounting plate by drilling holes, and then installing the screws, and fastening the
mounting plate onto the wall.
1.2.
3.4.
3. Route the wire through by inserting the wire between the foam sealing block. Verify the foam
seals against the wires to prevent insects from entering the device. Refer to Figure 2.2.
4. Attach the sensor to the mounting plate, and then fasten the screws.
Figure 2.2: Inserting the wire and fastening the mounting plate to the sensor.
5. Close the sensor by fastening the device xing screws, and then close the cover.
2.2 Pole mount installation
1. Route the wire through the wire hole of the pole.
2. Attach the bracket to the pole with the pole mount clamp.
1.2.
Figure 2.3: Routing the wire through the pole and attaching the bracket to the pole holder.
3 Wiring
3.1 Terminal strip overview
1
2
3
4
5
6
1111 11
7
4
2
9
9
7
8
9
10
1.1 Coverage range:
Model Outdoor Indoor
ISC-FPB1-W30DS 30 m/100 ft 60 m/200 ft
ISC-FPB1-W60DS 60 m/200 ft 120 m/400 ft
ISC-FPB1-W90DS 90 m/300 ft 180 m/600 ft
1.2 Accessories:
Accessories
BH12T 10.5V-28VDC Heater
MP1 Metal pole, 1 m (3 ft)
MP2 Metal pole, 1.2 m (4 ft)
MP3 L-curved metal pole
Callout - Description
1 - Knockout 4 - Pole mount bracket
2 - Center of the upper beam 5 - Pole mount clamp
3 - Center of the lower beam 6 - Pole diameter between 38-42.7 mm/1.49-1.68 in
Callout - Description
1 - Transmitter 4 - Alarm contacts
2 - Receiver 5 - Power (non-polarized)
3 - Tamper (normally closed) 6 - FREE (unused)
12
3
4
5
36
5
66.7 mm (2.62 in)
83.5 mm (3.28 in)
Photobeam 3000
ISC-FPB1-W30DS, ISC-FPB1-W60DS,
ISC-FPB1-W90DS
© 2014 Bosch Security Systems, Inc. F.01U.282.674 | 05 | 2014.10 | C
Region Certication
US UL 639 Listed - Intrusion Detection Units and Systems
10 Certications
6 Optical axis alignment
You can align an optical axis two ways: with a level LED and/or with a
tester.
3.2 Wiring lengths
Each value in the table below represents the maximum wiring distance (one way) when using
DC12V or DC24V power source. When installing 2 or more sets on one wire, obtain the maxi-
mum length by dividing the maximum wire length listed below by the number of sets installed.
When using a thicker wire gauge (19 AWG or 0.9 mm wire), use relays for connection. It is not
possible to connect directly to the terminal inside of the detector.
Figure 6.1: Level LED adjustment
6.1 Using an optical alignment
6.1.1 Coarse adjustment
Use the horizontal adjustment turntable and the vertical adjustment screw to
aim the optics at the detector scope view nder.
CAUTION!
Ensure that proper safety precautions such as powering off the device, and/
or protecting the wire from outdoor elements is adhered to. Failure to do so
may result in personal injury, or damage to the device.
8 Maintenance
Inspect the device regularly for proper functionality. Check the following:
– Tester voltage level is above 1.9V.
– Power input voltage is between DC 10.5V and 28V.
– Alarm and tamper outputs are functional.
Table 3.2: Wire lengths
5 Sensitivity adjustment
Figure 5.1: Sensitivity adjustments
7 Operational check
Perform the following to test the operation of the detector.
7.1 Alarm operation
1. To check the alarm operation, walk along the assumed intrusion path near
the transmitter and receiver, in a “zig-zag” pattern to disrupt the beam
signal.
2. Check that the alarm LED lights up and the control panel receives the
alarm signal when the beam is interrupted.
7.2 Tamper operation
1. Check that the control panel receives a tamper alarm when either of the
transmitter and/or receiver covers are open.
6.2 Using a tester
6.1.2 Fine adjustment
Insert the volt meter tips into the test terminals of the receiver to check the
voltage. If the value is 1.9V or more, the adjustment is completed. If it is less
than 1.9V, adjust the transmitter and receiver until 1.9V or more voltage is
obtained. A voltage level of 2.2V or above is ideal.
Figure 6.2: Using the test terminals
9 Troubleshooting
Problem Cause Solution
False
alarms
Obstacle in the line of sight. Remove obstacle.
Optical alignment is incomplete. Perform optical alignment to obtain 1.9V or higher.
Unstable installation. Stabilize the installation condition.
Distance between transmitter and receiver
exceeds maximum range.
Adjust the installation distances to meet specied re-
quirements.
Interference from another transmitter. Take proper measurement to avoid interference.
Electrical noise nearby Change the location of the devices.
Sunlight penetrates receiver within +/- 3°. Swap the location of the transmitter and receiver.
No
alarm
A reective surface is parallel with the
beam.
Adjust horizontal axis to avoid beam reection, or adjust
unit distance from reective surface.
Reective oor surface. Adjust vertical axis to avoid beam reection, or adjust
unit distance from reective surface.
Interference from another transmitter. Take proper measurements to avoid beam interference.
4 Beam spread
The optical path forms as the beam spreads when it is reected against an adjacent reec-
tive surface such as a wall. Reection of this beam may prevent a true alarm condition even if
the beam from the transmitter to the receiver is interrupted. The beam from another detector
may affect and cause malfunction when a multiple number of detectors are installed.The beam
spread angle of this unit is about ±1°. Refer to the gure and table below to determine the
installation position and distance to be used when installing a multiple number of units.
Figure 4.1: Beam spread distances
Callout - Description
1 - Fast running at full speed 3 - Normal walking
2 - Walking with quick steps 4-5 - Slow motion
Wire Gauge Maximum wiring distance
ISC-FPB1-W30DS ISC-FPB1-W60DS ISC-FPB1-W90DS
AWG Ø mm 12V 24V 12V 24V 12V 24V
22 0.65 270m/885ft 1980m/6500ft 210m/670ft 1890m/6200ft 170m/560ft 1530m/5020ft
19 0.90 530m/1738ft 4770m/15650ft 410m/1350ft 3690m/12105ft 340m/1115ft 3060m/10040ft
16 1.20 970m/3182ft 8730m/28701ft 750m/2460ft 6750m/22150ft 620m/2035ft 5580m/18310ft
Distance and (approximate) beam spread
Distance (A) Beam spread width (B) Distance (A) Beam spread width (B)
15m/49 ft 0.5m/1.6 ft 90m/295 ft 3.0m/9.8 ft
30m/98 ft 1.0m/3.3 ft 120m/394 ft 4.0m/13.1 ft
60m/197 ft 2.0m/6.6 ft 180m/591 ft 6.0m/19.7 ft
Callout - Description
1 - Turntable 3 - Scope view nder
2 - Verticle adjustment screw
Callout - Description
1 - Test terminals
Product Name Photoelectric Detector
Model ISC-FPB1-W30DS ISC-FPB1-W60DS ISC-FPB1-W90DS
Max. outdoor range 30 m (100 ft) 60 m (200 ft) 90 m (300 ft)
Max. indoor range 60 m (200 ft) 120 m (400 ft) 180 m (600 ft)
Transmitter current draw at 25°C (77°F) 6 mA 10 mA 15 mA
Receiver current draw at 25°C (77°F) 24 mA
Power DC10.5V - 28VDC
Sensitivity 50 ms - 700ms (Selectable)
Horizontal adjustability +/- 90°
Vertical adjustability +/-5°
Alarm output Form C relay (DC30V, 0.1A)
Tamper output Form B relay (DC30V, 0.1A)
Operating Temperature (Relative humidity) -25°C - +55°C (-13° F - +131° F (96% or less RH)
Storage Temp/Humd -30°C - +60°C (-22° F - 140° F (95% or less)
IP rating (indoor/outdoor) IP55
Weight (transmitter and receiver each) 380 g (0.84 lbs)
Dimensions 77 x 177 x 83 mm (3 x 7 x 3.27 in)
11 Specications
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. Web site at: http://www.
boschsecurity.com/datecodes/.
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany

This manual suits for next models

2

Other Bosch Security Sensor manuals

Bosch MX934i User manual

Bosch

Bosch MX934i User manual

Bosch ISC-BDL2-WP6 User manual

Bosch

Bosch ISC-BDL2-WP6 User manual

Bosch PAVIRO Series User manual

Bosch

Bosch PAVIRO Series User manual

Bosch ISW-EN1262 User manual

Bosch

Bosch ISW-EN1262 User manual

Bosch AVENAR detector4000 User manual

Bosch

Bosch AVENAR detector4000 User manual

Bosch FMC-210-SM-G-R User manual

Bosch

Bosch FMC-210-SM-G-R User manual

Bosch Door/window contact II Operator's manual

Bosch

Bosch Door/window contact II Operator's manual

Bosch FCP-320 Series User manual

Bosch

Bosch FCP-320 Series User manual

Bosch DS940P User manual

Bosch

Bosch DS940P User manual

Bosch ISC-PDL1-W18G User manual

Bosch

Bosch ISC-PDL1-W18G User manual

Bosch DS9370E User manual

Bosch

Bosch DS9370E User manual

Bosch ISN-AP1 User manual

Bosch

Bosch ISN-AP1 User manual

Bosch DS150I User manual

Bosch

Bosch DS150I User manual

Bosch ISA-WM-869 User manual

Bosch

Bosch ISA-WM-869 User manual

Bosch Blue Line P1 User manual

Bosch

Bosch Blue Line P1 User manual

Bosch DS935Z User manual

Bosch

Bosch DS935Z User manual

Bosch DS940Q User manual

Bosch

Bosch DS940Q User manual

Bosch DS 935 LSN User manual

Bosch

Bosch DS 935 LSN User manual

Bosch DM-TP-50(80) User manual

Bosch

Bosch DM-TP-50(80) User manual

Bosch ISC-CDL1-W15G User manual

Bosch

Bosch ISC-CDL1-W15G User manual

Bosch ISN-SM-50 User manual

Bosch

Bosch ISN-SM-50 User manual

Bosch DS935LSN User manual

Bosch

Bosch DS935LSN User manual

Bosch Motion Detector User manual

Bosch

Bosch Motion Detector User manual

Bosch DS9360 TriTech User manual

Bosch

Bosch DS9360 TriTech User manual

Popular Security Sensor manuals by other brands

Dräger Bio-Check Formaldehyde Instructions for use

Dräger

Dräger Bio-Check Formaldehyde Instructions for use

CMC ROCO Cobra manual

CMC

CMC ROCO Cobra manual

SPX Sensory Trainers General instructions

SPX

SPX Sensory Trainers General instructions

Orbis NEOMAT quick start guide

Orbis

Orbis NEOMAT quick start guide

AJAX DoorProtect user manual

AJAX

AJAX DoorProtect user manual

Honeywell C7061A Product data

Honeywell

Honeywell C7061A Product data

LEGRAND ECONOMY EXIT SIGN ER2 installation instructions

LEGRAND

LEGRAND ECONOMY EXIT SIGN ER2 installation instructions

Campbell TempVue 20 SDI-12 product manual

Campbell

Campbell TempVue 20 SDI-12 product manual

Megger VF5 quick start guide

Megger

Megger VF5 quick start guide

Orno OR-CR-209 operating manual

Orno

Orno OR-CR-209 operating manual

Johnson Controls HTD-432 PG2 quick start guide

Johnson Controls

Johnson Controls HTD-432 PG2 quick start guide

Carrier DET-TRONICS Dual Spectrum PM-5MPX instructions

Carrier

Carrier DET-TRONICS Dual Spectrum PM-5MPX instructions

ActSafe ACX user manual

ActSafe

ActSafe ACX user manual

Infinite L-COM SRCN-C412-2 user guide

Infinite

Infinite L-COM SRCN-C412-2 user guide

Polymer Laboratories PL-ELS 2100 Service manual

Polymer Laboratories

Polymer Laboratories PL-ELS 2100 Service manual

Besantek BST-CL01 instruction manual

Besantek

Besantek BST-CL01 instruction manual

Paradox DG457 user manual

Paradox

Paradox DG457 user manual

foc.us MC-735 installation manual

foc.us

foc.us MC-735 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.