Brähler Systems CDSVAN User manual

CDSVAN Digital Conference Management System
MSI8V B IV Digital Transmitter for band IV
Operating instructions
Rev 1.3

Printed in Germany
If you have questions about this manual please contact:
Brähler ICS Konferenztechnik
International Congress Service AG
P.O. Box 32 64
D-53627 Königswinter
Wahlfelder Mühle 3
D-53639 Königswinter
T +49 (0)2244 930-0
You will find further information about our products on the internet at:
www.braehler.com
© 2010
BRÄHLER ICS AG, Königswinter
All rights reserved, especially (also partly) the translation, reprint, reproduction through copying or other
similar methods.
BRÄHLER ICS reserves the right to make changes without notice.
INFRACOM® and DIGIMIC® are registered trademarks
Operating instructions CDSVAN, BGE-MSI8V-BIV (1.x).doc

CDSVAN MSI8V BIV
Copyright by Brähler ICS 3
Safety instructions
CAUTION
DANGER OF ELECTRIC SHOCK
DO NOT OPEN DEVICES
Do not open housing with mains cable connected.
Maintenance operations may only be executed by
qualified personnel.
Our equipment and installations have been built and tested according to the latest state of the art. Under
normal conditions, they do not require any special maintenance.
However, please be aware of the following:
secure and stable position of the installation
sufficient ventilation - never operate equipment near heat sources such as heating radiators etc.
power connection - install all power cables to avoid damaging
connecting cables - avoid trip-traps
liquids - avoid penetration of liquids into the housing
exclusively operate equipment via wall sockets that are connected to ground according to the relevant
specifications and regulations
Warning: Never expose equipment to rain or humidity
Please be also aware of the fact that rough handling of the equipment, such as strong bumps or vibrations,
may result in damages. Inappropriate handling and storage, i.e. handling and storage not in conformity with
the operating instructions, may as well lead to equipment damages.

MSI8V BIV CDSVAN
Copyright by Brähler ICS
4

CDSVAN MSI8V BIV
Copyright by Brähler ICS 5
Content
Safety instructions ............................................................................................................3
About this manual .............................................................................................................6
Symbols...............................................................................................................................6
Important remarks.............................................................................................................7
Important information...........................................................................................................8
Overview.............................................................................................................................9
System function ...................................................................................................................9
Use......................................................................................................................................9
Compact transmitter MSI8V BAND IV................................................................................10
Controls on the front site................................................................................................11
Power Switch.....................................................................................................................11
Infrared test diodes............................................................................................................11
LED AF/ON........................................................................................................................12
Frequency band setting......................................................................................................12
Rotary channel selector switch...........................................................................................12
Controls on the rear panel..............................................................................................13
Termination LINK...............................................................................................................13
Connecting the VAN-IN socket...........................................................................................13
Connecting the VAN-LINK socket ......................................................................................13
Connecting LINE-OUT sockets..........................................................................................14
Connecting RF-LINK socket...............................................................................................14
Connecting radiator sockets...............................................................................................14
Connecting mains power....................................................................................................14
Starting up........................................................................................................................15
Applications.....................................................................................................................16
Appendix..........................................................................................................................19
Technical Data MSI8V Band IV..........................................................................................19
Optional accessories..........................................................................................................19
Block diagram....................................................................................................................20
System Components..........................................................................................................20
Troubleshooting.................................................................................................................21
SERVICE FORM................................................................................................................23
Adresses............................................................................................................................25

MSI8V BIV CDSVAN
Copyright by Brähler ICS
6
About this manual
Symbols
The following symbols and fonts are used in this manual:
Indicates an important note, which has to be followed to guarantee that the functions of the unit, the
security of any data or your health are not put at risk
Indicates additional information, remarks and tips
Describes activities that must be performed in the shown order
Words in bold letters require your special attention.

CDSVAN MSI8V BIV
Copyright by Brähler ICS 7
Important remarks
For customers in the EU and in the USA
Our equipment has been tested and complies with the requirement of the CE test. This guarantees the
protection against harmful interferences, when the equipment is operating in a commercial environment. If
the unit is not proper installed to this user manual it may causes radio interferences. Any changes or
modifications not explicit approved in this manual could void your authority to operate this equipment.
For customers in the United Kingdom
The wires in the main lead are colored in accordance to the following codes:
Green-and-yellow: Earth
Blue: Neutral
Brown Live
If the colors of the wires in the mains lead of this unit are not corresponding with the colored markings of the
terminals in your plug, so please proceed as follows:
The green-and-yellow wire must be connected to the plug terminal marked with the letter E, with the safety
earth symbol or with green-and-yellow colour. The blue wire must be connected to the terminal marked with
the letter N or with black colour. The brown wire must be connected to the terminal marked with the letter L
or with red colour.
The equipment must be connected to earth!
Safety
Check that the operating voltage of the unit is identical with the voltage of your local mains power. If a
voltage conversion is required, consult your BRÄHLER ICS dealer or qualified personnel.
Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified
personnel before it will be used again. Unplug the unit from the wall outlet or set the Main Power switch to
OFF if it is not used for several days. To disconnect the cord, pull it out holding the plug. Never pull the cord
itself.
Installation
Allow adequate air circulation to prevent internal heat accumulation. Do not place the unit on a surface (rugs,
blankets, etc.) that may block the ventilation holes.
Do not install the unit in locations near heat sources such as radiators or air ducts, nor in places exposed to
direct sunlight, excessive dust or humidity, mechanical vibration or shock.
To avoid condensation do not install the unit where the temperature may increase rapidly.
Cleaning
To keep the surface of the housing in a proper condition, periodically clean it with a soft cloth. Large staining
may be removed with a cloth lightly dampened with a mild detergent. Never use organic solvents such as
thinners or abrasive cleaners since these might damage the surface.
Repacking
Save the original shipping box and packing material. For maximum protection, re-pack the unit as originally
packed from the factory.
If not supplied with the equipment, a complete transportation and storage box system is available from
BRÄHLER ICS. We recommend using this system for long-term protection and care.
General
Please keep this manual together with the CDSVAN Compact Transmitter MSI8V Band IV. If you hand on
the units to third parties, please include this manual.

MSI8V BIV CDSVAN
Copyright by Brähler ICS
8
Please read the manual carefully, taking special care when you see this symbol as it indicates
important information!
This product is conforming to the rules of the following European directive:
2004/108/EG
Council directive to the alignment of the rules of rights of all member states about the electromagnetic
compatibility, modified through RL 91/263/EWG, 92/31/EWG and 93/68/EWG of the council. Further
information is available on request.
The warranty will expire, if you cause defectives through inappropriate use or handling of the unit.
Important information
The unit should not be used at the maximum volume setting. Adjust the volume to a more suitable
level.
High sound pressure levels will damage your hearing!

CDSVAN MSI8V BIV
Copyright by Brähler ICS 9
Overview
The Compact Transmitter MSI8V BAND IV is used within the CDSVAN Conference System for transmission
of 8 audio channels by infrared light.
System function
The audio signals are converted into frequency modulated infrared light and then transmitted by means of
INFRACOM Radiators IRad, which are directly connected to the MSI8V BAND IV. The original (OR) and up
to 7 other languages can be simultaneously transmitted on different carrier frequencies by narrowband
frequency modulation.
Infrared radiators transmit the information carried by the audio channels in the form of frequency-modulated
infrared light. The transmitted signals are received by the INFRACOM Receiver IRX BAND II/IV and can be
monitored by headphones. Receivers can be moved at will anywhere within the area that is fully illuminated
by the radiators. They can be switched to receive up to 32 channels.
With miniature-switches on the front panel the frequency band can be chosen and the channels can be
switched ON or OFF. With a rotating switch it is possible to assign up to 32 transmission channels.
3 infrared transmitter diodes on the front panel allow monitoring for the technician without radiators.
LEDs on the front panel are indicating the operation mode: channel ON (red) and audio signal
available (green).
Use
In combination with the digital conference management system CDSVAN, the system can provide the best
possible communication facilities for organized events that need to use several languages.
Each and every participant (a term often used is "delegate") can use the microphone system to speak, and
what he or she says will be translated simultaneously so that other delegates will be able to listen to it in one
of the several languages. This technique permits direct communication in several languages even at very
large scale events.
It is a simple matter to set up the INFRACOM system in such a way that it is protected against eaves-
dropping from outside. Since all information is transmitted in the form of light waves, it is possible to use
opaque material as necessary to limit the area to which it is to be transmitted. Dark curtains drawn across
windows, for instance, are enough to shield a room reliably from the outside world.
Although the CDSVAN system is most commonly used in combination with an INFRACOM interpretation
system and microphone-management system it is also possible to use it for other purposes.
During organized events, for instance, it is possible to use infrared light to transmit information to individual
participants wearing receivers without disturbing anyone else present.
Another example might be museums applications. There it is possible to provide information on individual
exhibits by means of infrared light radiated only to a limited area in front of the particular exhibit. Visitors
listen to the information with receivers and headphones.

MSI8V BIV CDSVAN
Copyright by Brähler ICS
10
Compact transmitter MSI8V BAND IV
Front View
The front of the MSI8V compact transmitter is equipped with:
power switch with green Einschaltkontrollleuchte
8 green LEDs (AF) to display "Audio available"
8 red LEDs (ON) to indicate "channel on"
8 DIP switches for setting the frequency band
8 rotary switches for channel selection
3 emitting diodes for test mode (allowing the technician listening without radiator)
Rear View
The Compact Transmitter MSI8V B IV has the following sockets on the rear side:
VAN-IN (RJ45 socket) for connecting to the CDSVAN PC (Computer)
VAN-LINK (RJ45 socket) for cascading (Audio) with a second MSI8V B IV
LINE-OUT: eight sockets for audio recording
RF-LINK: socket for cascading (RF) with further MSI8V BAND IV
RADIATORS / IR-LINE: 2 x BNC sockets for connecting distribution SV/BNC-IV.
Mains power connector.
Wiring the radiators in band IV you must be aware of the following: Due to the higher carrier
frequencies the BNC cables to the radiators must have the same length. Using two radiators in a
row, the highest distance should not be greater than a meter. Otherwise, there will be overlaps or
extermination.

CDSVAN MSI8V BIV
Copyright by Brähler ICS 11
Controls on the front site
The Compact Transmitter has an ex-works mains voltage setting of 90 - 250 Volts by 50 –60 Hz. If
there is another voltage range you must not connect this equipment.
In connecting the system, special attention is to be paid to ensure that all cables are installed in
cable ducts or that they are fixed by cable clamps or adhesive tape in such a way that there is no
danger of somebody tripping over them.
Power Switch
Turn on or off the device with the power switch. The switch has a green light showing widely
visible the status.
Infrared test diodes
Three transmitting test diodes allow testing the receivers at a maximum
distance of 3 meters between the test-LEDs and the receiver.
Power switch
3 Test diodes
Channel
selection
DIP-switch setting
channel range
ON LED
AF indicator
LED

MSI8V BIV CDSVAN
Copyright by Brähler ICS
12
LED AF/ON
AF: This LED indicates a signal on this output (for example line 1).
ON: This LED represents the ON-status of the corresponding output channel.
Remark: Not used channels should be switch off to increase the IR power.
ON- and OFF-status is set with the left DIP-switch.
Frequency band setting
DIP switch for setting the frequency band.
With the DIP switches 3 +4 you can enter the desired frequency band,
see chapter starting up
Rotary channel selector switch
Switch for channel selection.
Depending on the chosen frequency band (DIP switch 3 +4) you can set the
channel, see chapter starting up

CDSVAN MSI8V BIV
Copyright by Brähler ICS 13
Controls on the rear panel
Termination LINK
Termination of the LINK socket via DIP switch:
ON: LINK socket not used (open)
OFF: LINK socket connected with another Compact Transmitter MSI8V BAND IV
Connecting the VAN-IN socket
RJ45 for the connection to the CDSVAN-PC (transmission of the channels)
Connecting the VAN-LINK socket
Within a 16 channel system (1+15) the LINK socket can be used to transmit the
channels 8 –15 to the next MSI8V BAND IV.
In this case the RF-Link socket (next page) also should be connected between the 2
MSI8V BAND IV.
VAN-IN
VAN-LINK
LINE OUT,
channel 1-8
Mains Power
Link connector
BNC
Radiator
connectors via
SV/BNC-IV
Termination LINK

MSI8V BIV CDSVAN
Copyright by Brähler ICS
14
Connecting LINE-OUT sockets
Eight XLR LINE-OUT connectors
(male):
All eight channels fed into the
MSI8V B IV from the CDSVAN
system via CAT5 are available at
these connectors, e.g. for audio
distribution or recording purposes.
Connecting RF-LINK socket
BNC socket for cascading further Compact Transmitter MSI8V / BAND IV. To manage more
Outputs you can extend the system to more outputs.
Connecting radiator sockets
IR-LINE 1 and 2: BNC sockets for connecting INFRACOM® video
distributors SV/BNC-IV.
Wiring the radiators in band IV you must be aware of the following: Due to the higher carrier
frequencies the BNC cables to the radiators must have the same length. Using two radiators in a
row, the highest distance should not be greater than a meter. Otherwise, there will be overlaps or
extermination.
If there are more radiators needed we recommend the use of an active distributor SV/BNC. Our planning
department will be glad to help you.
Connecting mains power
Connect the delivered cable with this socket to
ensure the proper working of the Compact
Transmitter.

CDSVAN MSI8V BIV
Copyright by Brähler ICS 15
Starting up
The power supply is turned on via the power switch on the front side of the Compact Transmitter
MSI8V B IV.
Using the Compact Transmitter the first time it is necessary to adjust the provided channels. This
procedure will allocate the transmitter frequencies to the respective channels.
For adjusting this allocation refer to the following figure. The scheme is enclosed with the Compact
Transmitter as a separate sticker which may be adhering to the front panel.
OFF
ON
Ch16 - Ch31
OFF
ON
ChOR-Ch15
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
1
6
1
7
1
8
OR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
The setting for the floor channel to channel 15 is shown on the left figure above. The allocated channel
setting is done with the rotary switch.
The setting for channel 16 to channel 31 is shown on the right figure above.
The left DIP-switch will activate the corresponding channel. Left DIP switch to ON means channel is active.
Once the CDSVAN system has been properly started up and checked, there is usually no need for any
further intervention from the operator.
All levels are set and stored within the CDSVAN software environment.
Most of the work involved with audio distribution should have been completed during the preselection of
channels and system start-up
Examples:
Channel 2
Channel 24
Channel 30
Setting for floor
channel to
channel 15
Setting for
channel 16 to
channel 31

MSI8V BIV CDSVAN
Copyright by Brähler ICS
16
Applications
In the following you see some examples in form of a block diagram:
Application 1
This diagram shows a complete wiring for a 16 channel (OR + 15) interpreter system. Monitoring part is the
Receiver IRX (Band II/IV) together with the IR-Radiator IRad.
CDSVAN System Components
CDSVAN PC: Including CDSVAN Software and DSP Hardware
MSI8V B IV: BAND IV Compact Transmitter
IRad: High Power Radiator
IRX: BAND II/IV receiver for up to 32 channels
Please note that the lines of the radiators MUST NOT differ in length (length A =
length A; length B = length B, etc.)
Please note also that all open lines of the distributor SV/BNC have to be terminated (50
Ohm resistor). The radiators have a switch for line termination.
MSI8V-Band IV
Link
IN
OR - 7
8 - 15
SV/BNC-IV
Radiators
SV/BNC-IV
SV/BNC-IV
SV/BNC-IV
SV/BNC-IV
SV/BNC-IV
IRad
IRad
IRad
IRad
1
4
7
10
IRad
IRad
IRad
IRad
2
5
8
11
IRad
IRad
IRad
IRad
3
6
9
12
IN
MSI8V-Band IV
length A
length A
length B
length B
length B
length B
length C
length C
IR Link
IR Link
Wiring diagram for 12 radiators

CDSVAN MSI8V BIV
Copyright by Brähler ICS 17
The next diagram (Application 2) shows the wiring for an 8 radiator system:
Application 2
Two Compact Transmitters MSI8V B IV are linked to one system (16 channels). The monitoring part consists
of the Receiver IRX / BAND IV together with the IR-Radiator IRad.
CDSVAN System Components
CDSVAN PC: including CDSVAN Software and DSP Hardware
MSI8V B IV: BAND IV Compact Transmitter
IRad: High Power Radiator
IRX: BAND II/IV receiver for up to 32 channels
Please note that the lines of the radiators MUST NOT differ in length.
Please note also that all open lines of the distributor SV/BNC-IV have to be terminated
with 50 Ohm resistor. The radiators have a switch for line termination.
CDSVAN IN
Wiring diagram for 8 radiators
MSI8V-Band IV
Link
VAN IN
OR - 7
8 - 15
SV/BNC-IV
SV/BNC-IV
IRad
IRad
IRad
1
4
7
IRad
IRad
IRad
2
5
8
IRad
IRad
3
6
length A
length A
length B
length B
MSI8V-Band IV
length B
length B
length B
length B
length B
length B
Radiators
Radiators
Terminator
Terminator
IR Link
IR Link

MSI8V BIV CDSVAN
Copyright by Brähler ICS
18
The next diagram (Application 3) shows the wiring for 6 radiators:
Application 3
This diagram shows a wiring application for a 7 (OR + 6) channel system. Monitoring part is the Receiver
IRX II/IV together with the IR-Radiator IRad.
CDSVAN System Components
CDSVAN PC: including CDSVAN Software and DSP Hardware
MSI8V B IV: Compact Transmitter for band IV
IRad: High Power Radiator
IRX: BAND II/IV receiver for up to 32 channels
Please note that the lines of the radiators MUST NOT differ in length.
Please note also, that all open lines of the distributor SV/BNC-IV have to be terminated
with 50 Ohm resistor. The radiators have a switch for line termination.
Wiring diagram for 6 radiators
Link
OR - 7
SV/BNC-IV
SV/BNC-IV
IRad
IRad
1
6
IRad
IRad
2
4
IRad
IRad
3
5
length A
length A
length B
length B
MSI8V-Band IV
length B
length B
length B
length B
Radiators
Terminator
Terminator
CDSVAN IN

CDSVAN MSI8V BIV
Copyright by Brähler ICS 19
Appendix
Technical Data MSI8V Band IV
The unit is complying with the international standard IEC914.
Connections
VAN-IN (1 x RJ45-socket) for connection to the CDSVAN-PC
VAN-LINK (1 x RJ45-socket) for cascading (Audio) with a second MSI8V / BAND IV
LINE-OUT (8 x XLR-plug) AF outputs for audio recording
IR-LINE (2 x BNC-socket)
1: Connection for up to 2 INFRACOM radiators IRad respectively distributor SV/BNC for more
radiators
2: Connection for up to 2 INFRACOM radiators IRad respectively distributor SV/BNC for more
radiators
IR-LINK (1 x BNC-socket) for cascading (RF) with further MSI8V / Band IV
Features
Green lighted mains switch for power ON indication
Red LEDs for channel switched ON
Green LEDs for Audio available (AF)
Transmission frequency
1935kHz - 3175kHz (channel 31) in 40kHz steps
Intermediate frequency: 455 kHz
Measurements
Distortion: < 0.2%
Signal-to-noise ratio: > 70dB
Channel separation: > 60dB
Power Supply
Mains power: (90 ... 250)VAC, (50 ... 60)Hz
Power consumption: 40VA max
Housing
19”, 2 HE, Aluminum, “silver” anodized
W x H x D: (433 x 88 x 305)mm
Weight
4.6kg
Optional accessories
(not included in delivery)
INFRACOM Radiator IRad
INFRACOM Receiver IRX BAND II/IV
CAT5 cable, shielded, different length available, according to Brähler specification
BNC cable (50 Ohm) different length available
Mounting brackets for rack assembly

MSI8V BIV CDSVAN
Copyright by Brähler ICS
20
Block diagram
General overview of CDSVAN devices
AB
CD
EF
GH
MIDI IN/OUT
analog in analog out
PA System
CDSVAN Computer
Remote Systems
DSP6 PCI-Card
Camera Control
MotorMixer
Remote Level Control
PSU04 Power Supply Unit
MSI8V Compact Transmitter
RSP8V Digital
Distribution Amplifier EWD216 Channel Selector
IRad (INFRACOM®) High Power Radiator IRX (INFRACOM®) Receiver
To PA system
DV9 Digital Delegate Unit
DDV9 Dual Digital Delegate Unit
DOLV Digital Interpreter Console
B8 AD/DA Interface
System Components
CDSVAN pro Audio processing software
DSP6/15 RJ45 DSP Card with 6 or 15 digital sound processors and EDAT I/O plate
DOLV Interpreter Console for up to 32 channels
DV9 Delegates´ Unit
DDV9 Delegates´ Unit for two delegates
PSU04 Power Supply Unit, up to 4 branches for interpreter consoles/ delegate units
PSU01MA/SL Additional Power Supply for interpreter consoles/ delegate units
B8 AD/DA Interface 8 channels
MotorMixer Remote Mixer with 8 motorized faders
RSP8V Digital Distribution Amplifier
MSI8V INFRACOM Infrared Transmitter (Band II)
IRad INFRACOM Infrared Radiator
IRX INFRACOM Infrared Receiver for band II and IV
Cables CAT5, different length, according to Brähler specification
Other manuals for CDSVAN
1
This manual suits for next models
1
Table of contents
Other Brähler Systems Conference System manuals

Brähler Systems
Brähler Systems DIGIMIC SMic133D User manual

Brähler Systems
Brähler Systems DIGIMIC CMic ID User manual

Brähler Systems
Brähler Systems DIGIMIC DCen MkII User manual

Brähler Systems
Brähler Systems DIGIMIC CMic ONE User manual

Brähler Systems
Brähler Systems DIGIMIC Series User manual

Brähler Systems
Brähler Systems DIGIMIC DLine32 User manual

Brähler Systems
Brähler Systems DIGIMIC DCen mini User manual