Installation requirements and recommendations
Recommended room size
Square footage
Minimum: 8.0' x 8.0' (240 x 240 cm)
Maximum: 30.0' x 30.0' (910 x 910 cm)
Recommended integrated microphone and speaker
bar installation height
Minimum: 7'1″(147cm)
Maximum: 10′(305cm)
Ensure there is adequate clearance below the microphones
When installing the system, ensure the integrated microphone and
speaker bar has adequate clearance between the bottom of the bar
and any objects located directly below the bar.
Do not install the microphone and speaker bar above
hardware with fans
Hanging the product above hardware with fans, such as flat panel
displays, can cause interference with the microphone pickup.
Microphone clearance requirements
The microphone array is located along the
bottom edge of the microphone and speaker
bar. Ensure the installation location meets the
following requirements and recommendations to
optimize microphone pick up.
1
2
Allow for adequate space between the outside edges of the speaker bar and the
corners of the room
Installing the integrated microphone and speaker bar against the corner of a room will impede the
microphone pickup.
3
1