7
4
4
2
1
Turn flow handle to ‘on’
position, letting temperature
stablise.
Turn cartridge spindle clockwise
to decrease the temperature.
Turn cartridge spindle
anti-clockwise to increase the
temperature.
3
5
2
Using the wall
mount, isolate
both shower inlets
before carrying out
any maintenance.
Unscrew the
cartridge using a
socket or box spanner.
Troubleshooting
To reduce the build up of
limescale and to ensure this
shower works to its maximum
performance we recommend
this shower is serviced every
6-12 months depending on the
hardness of your water.
To replace any spare parts for
your shower why not scan the
below QR Code and search for
your product.
Spare Parts
Servicing Intervals
Temperature Setting
Maintenance - Cartridge Cleaning
3
1
6
Symptom Cause Remedy
No flow or
low flow rate
partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on and o
as flow rate or pressure is too low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.
2 meters minimum required.
Hot or cold water being drawn o elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply
pipework.
Flush through pipework to ensure removal of debris and
any airlocks.
Water
dripping
from shower
This is normal for a short time after using the
shower.
This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip,
possibly due to the cartridge
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Shower does
not turn on
Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
REMEMBER
To service
your
product!
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer solid guarantees on
all our products, eective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors
will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
34
5
Remove
temperature and
flow handles
Remove O-rings
and soak all
components in
de-scaler and wash o in clean
water. Examine all seals and
replace if needed. Use WRAS
approved silicon based grease
on all seals.
Reverse steps 5-2 to
reinstall the valve,
cartridge and handles.
Turn the water
supply to the
shower back on.
Remove cartridge
retainer and
cartridge
Remove
temperature
handle
Replace
temperature
handle
4
1
56
Riser Installation 23
Attach handset and fixed head.
To adjust the riser pull the top cap up and
use a hexagonal spanner to loosen the nut.
Pull rail to desired position then tighten the
nut and pull cap back down.
Attach shroud and
secure riser to bracket by
tightening grub screws.
Secure bracket to wall
using screws and plugs
provided.
Disassemble bracket, align on
the wall in the correct position
and mark location of holes to
be drilled.
Using a spirit level
to ensure the riser is
positioned correctly,
use the assembled
riser to mark the
desired position of the
brackets.
Push the riser rail
into the bracket and
screw to tighten.