DUAL G703 Detector B044 Configuration and operation
2004 dB Broadcast Ltd 6 Version 1.0
Configuration
Each channel has a number of configuration jumper links and adjustments.
The B044 Dual G703 Detector showing jumper links
Channel A link functions and adjustments
Adjustment Main Module - Channel A jumpers
JP1 Select detected error to drive relay outputs FRM, LEV, AIS or CRC – see
next section
RV1 Adjust signal loss threshold
JP10 Fit this jumper to enable voltage spike suppression on the Channel A input
Channel B link functions and adjustments
Adjustment Main Module - Channel A jumpers
JP2 Select alarm signal to drive relay outputs FRM, LEV, AIS or CRC – see
next section
RV2 Adjust signal loss threshold
JP11 Fit this jumper to enable voltage spike suppression on the Channel B input
Mode selection – affects both channels
Adjustment Main Module - Channel A jumpers
JP3 Select Micro-controller mode CRC4_1, CRC4_2 or MF-Disable – see next
section