Front and rear view
Read carefully before use and keep for future reference
Touching the units with wet hands is forbidden
Using liquid cleaners or aerosols is forbidden
Blocking the ventilation openings is forbidden
Modifying the devices is forbidden
Removing protective parts from the devices is forbidden
Installing the units near liquids and powders is forbidden
Installing the units near heat sources is forbidden
Installing the units near harmful gases, metal dusts or similar is forbidden
Fastening the units on unsuitable surfaces is forbidden
Danger of electrical shock
Risk of devices falling because the surface on which they are installed collapses or inappropriate installation
Switch the power supply OFF before any work on the system
Caution: Installation, conguration, starting-up and maintenance must be performed exclusively by
qualied personnel.
Check that the wall installation has been carried out correctly
Lay out the wires respecting the standards in force
Connect the power supply wires as indicated
Use only the items indicated in the technical specications for any system expansions
Remote operation may cause damage to people or property.
Warnings and consumer rights
Hereby,BTicinoS.p.A., declares that the radioequipmenttypeEntrancepanelfull 10" - 374000/Entrancepanel10" - 3740002 isincompliancewith Directive 2014/53/EU.The full text oftheEU declaration of conformity isavailableatthefollowinginternetaddress: www.bticino.it/red
Configuration
The device must be congured by software. For software download, installation device documentation and for any
other information, refer to the website.
www.homesystems-legrandgroup.com
1. Microphone
2. LED for the shooting eld lighting
3. Camera
4. Light sensor
5. Display 10" (touch screen)
6. Badge reader for door lock opening
7. Loudspeaker
8. Finger print reader (only 374000)
9. Locking screws
10. USB Connector (not used)
11. RJ45 Connector (*)
12. Not used
13. Tamper switch
14. SD card
15. Connection clamp
16. Reset to the factory settings push button
17. Not used
18. Mounting bracket
(*)
This device does not support standard POE power supplies, but
only POE power supplies identied with item no. 375002.
Connect the cat5/5e/6 FTP or cat5/5e/6 UTP cable with
ferrite supplied to the connector
Technical data
Voltage 24 Vdc
Maximum consumption 0.65 A
C NC NO contact output 125 Vac/0.5A, 30Vdc/2A
Max. cable section for clamps 0.8 mm²
Operating temperature (- 40) – (+ 70) °C
IP degree of protection 54
IK degree of protection 07
Camera resolution 1080 p
Camera viewing eld angle H= 80°; V= 53°
Face recognition distance during daytime (374001 only) 30-80 cm
Face Recognition Distance at Night (374001 only) 30-50 cm
Badge reader Frequency 13.56 MHz
Badge reader transmission power < 42 dBuA/m @ 10m
31
5
2 2 4
6
77
8
9
13
14
15
11
15
16
17
12
10
18
GND
Fire Linkage
Door Open
Connection clamp
LOCK+ electric door lock connection and control
(12V - 4A impulsive on 3 Ohm maximum)
Door OPEN – GND local door lock release pushbutton connection
LOCK- FIRE Linkage – GND local door lock release pushbutton connection
for realarm system
SENSE door lock status signal input (dry contact) NO
interlocked contact
GND system common ground terminal for third party connection C
OPEN third party access control signal input for door lock
opening (+12Vdc pulse) NC
GND access control devices power supply DC24V additional power supply clamps (not polarized)
+12V RS485A
Lift Control
terminal A
RS485B terminal B
GND system common ground terminal for
RS485 connection