Beep
31: plug Chime into a UK 3pin
socket, 220 – 240V ~ 50Hz.
2: Switch the socket on.
3: Chime will ‘Beep’ on Start
1: Push Button 5: Portable Chime
2: Melody Selector 6: Speaker
3: Bell Push Battery 7: Volume Control
4: Signal Sent LED 8: Strobe Alert
Strobe Alert:
Strobe Light will flashPress to switch the
Strobe Alert On or Off
Chime will ‘Beep’
3
™Plug-in Strobe Alert
Wire Free Chime Kit
BY202F
1:
2:
4:
:3
1: Place a small flat screwdriver
into the locking clip on the
base of the Bell Push
2: Gently twist
3: The backing plate will unclip
1
6:
7:
5:
:8
To select the Chime Volume level, press the ‘VOL’
button on the chime There are 4 selectable volume
levels, the Door Chime is pre-set to the loudest
volume setting.
Volume
Default
Functions:
6 Selectable Melodies
1: Tubular 3-Note 4: Solo
2: Big Ben 5: Tubular Score
3: Tubular 2-Note 6: Clarinet
To select a melody for the Door Chime
1: Remove the Back Plate from the Bell
Push.
2: Press the Melody Select button.
3:The chime will play the newly selected
sound.
4: Press again to select the next melody.
Note: For Front/Back door setup, select a
different melody in one of the Bell Pushes.
CR2032
4
Beep
Beep
1: Press and hold the ‘VOL’
button on the Door Chime,
until the Chime goes
‘Beep Beep’ (6 Seconds).
2: Press the Bell Push within
60 seconds to learn the
Bell Push to the chime.
3: The Chime will ring to
confirm setup.
Note: Maximum of 6 Bell
Pushes can be learnt to a
single Chime.
4
Additional Chime
To add an additional Chime unit to the Door Chime kit
1: Press and hold the ‘VOL’ button on your New Door Chime, until the
Chime goes ‘Beep Beep’ (6 Seconds)
2: Press the Bell Push within 60 seconds to learn the additional
Chime to the Bell Push.
3: Chime will ring to confirm setup, wait 60 seconds for the Chime to
exit the learn mode before repressing the bell push.
Additional Bell Push
To add an additional Bell Push to the Door
Chime kit.
1: Press and hold the ‘VOL’ button on your
Door Chime, until the Chime goes
‘Beep Beep’ (6 Seconds).
2: Press the Bell Push within 60 seconds
to learn the additional Bell Push to the
Chime.
3: Chime will ring to confirm setup, wait 60 seconds for the Chime
to exit the learn mode before repressing the bell push.
For Front/back door setup, select a different melody in one of
the Bell Pushes - See Melody Selection.
Note: Maximum of 6 Bell Pushes can be learnt to a single Chime
Adding Additional Chime/Bell Push:
Front Door
Back Door
New Chime
Beep
Beep
1: Insert CR2032 battery
(Supplied) into the battery
holder.
2: Make sure the positive side
is facing upwards.
3: Replace back plate.
2
Warning: Make sure that the batteries are
replaced correctly to avoid battery failure.
Only replace with same or equivalent type.
Installation Guide:
3
Installation Guide: Bell Push
Installation Guide: Chime
Avoid locating the Bell Push/Chime on or directly near
metallic surfaces as this may reduce the operation
range.
UPVC Door Frames:
When locating the bell push onto a UPVC door, always
check the operating performance before final
installation, internal metal frame may affect
performance.
Note: Try adjusting the location of the Bell Push to the Left/Right or
place on external wall.
Range Guide
User Hints:
In case of the door chime does not sound, please check the
followings:
a) Flat batteries in either Push Button or Door Chime.
b) Wrong battery polarity in either Push Button or Door Chime.
c) For Plug-in Door Chimes make sure the socket is switched on.
d) Bell Push and Door Chime are not paired together, see setup
guide.
e) Materials in between the Bell Push & Chime will reduce the
operating range, move the Door Chime closer to the Bell Push
f) Wire free devices can be affected by external sources e.g. wire
free home alarms or power transformers/adapter
Plug-in Door Chime: BY202F
Power: 220 - 240V 50Hz
Range: 100 Metres
Indoor Use Only
Bell Push: BYT
Power: 1 x CR2032 3V DC Battery
(Included)
IP44 Weather Resistant
Type R2 Device - device where the sound output is created by the initial operation
of the control and where the period of sound output continues for the
designed duration irrespective of condition of the control.
IMPORTANT: There are no serviceable parts, do not repair.
Specification
433.92MHz
R&TTE
APPROVED
CH Byron Electrical United Kingdom. www.chbyron.com
A
B
DK
FIN
F
D
GR
LT
IRL
I
L
NL
P
E
S
UK
BG
CZ
EST
H
IS
LV
M
N
SK
SLO
CH
PL
RO
Project Manager
Mr G Hunter
GB: CH Byron
Byron House, Sherwood Rd
Astonfields, Bromsgrove
B60 3DR
UK
[email protected]
9-5 Mon-Fri, Local call charges apply
V1.0
Tel: 0845 2301231 (UK)
www.chbyron.com
433.92MHz
R&TTE
APPROVED
CH Byron Electrical United Kingdom. www.chbyron.com
A
B
DK
FIN
F
D
GR
LT
IRL
I
L
NL
P
E
S
UK
BG
CZ
EST
H
IS
LV
M
N
SK
SLO
CH
PL
RO
Project Manager
Mr G Hunter
V1.0
Bell Push: BYT
Power: 1 x CR2032 3V DC Battery
(Included)
IP44 Weather Resistant
Type R2 Device - device where the sound output is created by the initial operation
of the control and where the period of sound output continues for the
designed duration irrespective of condition of the control.
IMPORTANT: There are no serviceable parts, do not repair.
Specification
Place the door Chime within the operating range, transmis-
sion of the wire free signal through
Walls, Doors and Ceilings etc, may reduce the operating
range. Chime unit for INDOOR use only.
Diagram for illustration purposes only
2
‘CLICK’
1: Using back plate as a
template.
2: Making sure UP arrows
points UP.
2: Mark and drill holes.
3: Insert wall plugs and attach
to wall using screws
provided.
4: Clip the Bell Push on to the
back plate making sure the
Bell Push ‘Clicks’ in to
place.
Note: The Bell Push can be
installed using a suitable
double sided adhesive tab or
tape when drilling is not
sutiable.
1
Resetting Chime:
Reset Chime unit to factory settings.
1: Press and hold the ‘VOL’ button on your Door Chime,
until the Chime goes ‘Beep Beep’ (6 Seconds)
2: Release the ‘VOL’ button
3: Re-press and hold the ‘VOL’ button on your Door Chime,
until the Chime goes ‘Beep’ (6 Seconds)
4: The Chime is now reset.
Vol
Beep
Beep
Beep
Vol
Beep
Beep
Changing Batteries:
Bell Push:
1: Remove back plate from the
Bell Push.
2: Remove old battery from the
holder.
3: Replace with new ‘CR2032’ 3V
battery.
4: Insert into holder making sure
‘+’ is facing up.
5: Test Chime Kit.
Always dispose of old batteries in an environmentally friendly way.

Other Byron Accessories manuals

Byron DB401E User manual

Byron

Byron DB401E User manual

Byron SX228 Owner's manual

Byron

Byron SX228 Owner's manual

Byron BY102 Owner's manual

Byron

Byron BY102 Owner's manual

Byron SX-86 Owner's manual

Byron

Byron SX-86 Owner's manual

Byron Home Easy HE-202 User manual

Byron

Byron Home Easy HE-202 User manual

Byron BY212 Owner's manual

Byron

Byron BY212 Owner's manual

Byron BY112 User manual

Byron

Byron BY112 User manual

Byron DB303 Owner's manual

Byron

Byron DB303 Owner's manual

Byron TX-2 User manual

Byron

Byron TX-2 User manual

Byron Home Easy HE-413 User manual

Byron

Byron Home Easy HE-413 User manual

Byron SX-245 Owner's manual

Byron

Byron SX-245 Owner's manual

Byron DB300 Owner's manual

Byron

Byron DB300 Owner's manual

Byron 1200 User manual

Byron

Byron 1200 User manual

Byron DB302 Owner's manual

Byron

Byron DB302 Owner's manual

Byron B314 Owner's manual

Byron

Byron B314 Owner's manual

Byron B322 Owner's manual

Byron

Byron B322 Owner's manual

Byron Home Easy HE-301 User manual

Byron

Byron Home Easy HE-301 User manual

Byron DB333 Owner's manual

Byron

Byron DB333 Owner's manual

Byron SX-15i Owner's manual

Byron

Byron SX-15i Owner's manual

Byron BY103 Owner's manual

Byron

Byron BY103 Owner's manual

Byron TX-414 User manual

Byron

Byron TX-414 User manual

Byron SX-15 User manual

Byron

Byron SX-15 User manual

Byron 776 User manual

Byron

Byron 776 User manual

Byron Home Easy HE-304 User manual

Byron

Byron Home Easy HE-304 User manual

Popular Accessories manuals by other brands

IFM Efector 160 LR70 operating instructions

IFM

IFM Efector 160 LR70 operating instructions

PASCO PS-3208 Replacement instructions

PASCO

PASCO PS-3208 Replacement instructions

Omron E3X-NA - datasheet

Omron

Omron E3X-NA - datasheet

Aeon Labs MultiSensor 6 user manual

Aeon Labs

Aeon Labs MultiSensor 6 user manual

Leuze electronic MSI-SR-2H21 Series Original operating instructions

Leuze electronic

Leuze electronic MSI-SR-2H21 Series Original operating instructions

hager BODYGUARD-T Installation instructions manual

hager

hager BODYGUARD-T Installation instructions manual

Arenti 14T user manual

Arenti

Arenti 14T user manual

New England Arbors Lenox Assembly guide

New England Arbors

New England Arbors Lenox Assembly guide

TUV RF-MDWS quick start guide

TUV

TUV RF-MDWS quick start guide

HONGYUV HY-WDS2E operating manual

HONGYUV

HONGYUV HY-WDS2E operating manual

Masimo RD SET E1 Directions for use

Masimo

Masimo RD SET E1 Directions for use

HME Clear-Com FreeSpeak Edge user guide

HME

HME Clear-Com FreeSpeak Edge user guide

Gamko Gastro Series user manual

Gamko

Gamko Gastro Series user manual

Takegawa Super cool oil cooler kit instruction manual

Takegawa

Takegawa Super cool oil cooler kit instruction manual

Klarstein 10024005 manual

Klarstein

Klarstein 10024005 manual

Cool Collection Keynote user manual

Cool Collection

Cool Collection Keynote user manual

COMSOL SP150DP user manual

COMSOL

COMSOL SP150DP user manual

Siedle Novotechnik RFC-4800 user manual

Siedle

Siedle Novotechnik RFC-4800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.