CAMDEN CX-WEC Series User manual

Page 1 of 4
CX-WEC10BK2
Emergency Control Kit
INSTALLATION INSTRUCTIONS
Electrified Locks, Relays and Timers
THIS PACKAGE INCLUDES:
1. DESCRIPTION
The CX-WEC10BK2 Emergency Control Kit allows an individual to
push the “PRESS FOR EMERGENCY ASSISTANCE” button to signal
for help by illuminating the “Assistance Required” annunciator
on the outside, and the “Assistance Requested” annunciator on
the inside of the location. At the same time the sounders built
into both annunciators will activate. The kit includes signage
that states in the event of an emergency to press the button
and an audible and visual signal will activate.
The CX-WEC10BK2 kit comes with the inside activation and
annunciator built onto a double gang combination plate making
installations quicker since one back box install is needed rather
that two single gang boxes. The CM-AF142SO offers different
color options (Red, Green, Blue and White), an adjustable ash
rate and variable volume control.
Note: CX-WEC10BK2 Emergency Call System is OBC Regulation
368/13, Section 3.8.3.12 compliant.
2. OPERATION AT A GLANCE
When the “PRESS FOR EMERGENCY ASSISTANCE” button on
the CM-AF540SO is pushed in it will change its normally open
contact to a closed contact and activate the outside light and
sounder (CM-AF142S0) to signal for help. The inside lights
and sounder (CM-AF540SO) will also be activated giving the
individual inside conrmation that the action has taken place.
Once the emergency has been attended to the red mushroom
button on the CM-AF540SO can be pulled out to silence and
reset the system. The ash rate can be adjusted at the top right
of the circuit board after removing the front dome cover. The
volume can be increased or decreased by using the adjustment
screw on the back of the CM-AF142SO.
Power
Both the CM-AF540SO and the CM-AF142SO can be powered
with either 12/24 VAC/VDC.
Note: When the CX-WEC10BK2 is integrated with a Camden
Restroom Control Kit, VDC power must be used to prevent
the door strike from buzzing.
Wiring the CX-WEC10BK2 Emergency Control Kit
The inside and outside annunciators are wired in parallel to
make them work at the same time when triggered.
1- CM-AF540SO 1- CM-AF142SO 1- CM-SE21A
Take one of the black wires from the CM-AF540SO and the black
wire from the CM-AF142SO and tie them to the power supply's
VDC ground (-). Take the remaining black wire from the
CM-AF540SO and one of the Red, Blue or Green wires from the
CM-AF142SO (or take all colored wires from the CM-AF142SO to
make White) and wire it to the red mushroom buttons, normally
open contact marked with as terminal “3”. Next, wire the
terminal marked as “4” to the positive (+) terminal of the
VDC power supply.
Note: Some Door Operators provide excessive voltage levels
above their posted values. Always measure voltages provided
on both the VDC & VAC scales rst before applying power to
any part of the Emergency Control Kit.
3. INSTALLATION
CM-AF540SO
Supplied with a stainless steel
faceplate that can be easily
mounted to a double gang
electrical box.
Volume Adjust
Turn the volume adjust
clockwise to increase the
volume and counter
clockwise to decrease the
volume. Turn the volume
adjust all the way counter
clockwise to turn the
sounder completely off.
PRESS FOR
EMERGENCY
ASSISTANCE
Volume
Adjust
3
4
1
2

Page 2 of 4
CX-WEC10BK2 Emergency Door Control Kit
INSTALLATION INSTRUCTIONS
CM-AF142SO Mounts to a standard single gang electrical box.
Step 1
Place the gasket (supplied) between the base unit and the
electrical box. Use the 6-32 screws to fasten the base to the
electrical box.
Gasket
1
Base
FLASH RATE:
Increase or decrease
the flash rate by
gently turning the
potentiometer with
a small screwdriver.
2
O Ring
3
Lens
4
Locking Screws
A
S
S
I
S
T
A
N
C
E
R
E
Q
U
I
R
E
D
5
Labels
Labels
Step 2
Insert the O ring gasket into the small channel in front of the base.
The O ring does not completely close around the base.
You must leave a small opening at the bottom of the base.
Step 3
Install the lens by inserting the large bottom tab rst.
The top tabs will snap in place with little effort.
Step 4
Install the Phillips locking screw into the bottom of the base.
Step 5
Apply the labels as required to the lens.
12-24
AC/DC
Power
CM-AF142SO
Volume Adjustment
-+
- Black wire = Common
- Red wire = Red color
- Green wire = Green color
- Blue wire = Blue color
- Blue, Green & Red = White
Sound Volume Adjust
Using a small Phillips screwdriver, gently turn the volume
adjustment counter clock wise to reduce the volume and
clockwise to increase the volume.
Note: The ash rate can be
adjusted at the top right of the
circuit board after removing the
front dome cover. The volume
can be increased or decreased
by using the adjustment screw
on the back of the CM-AF142SO.

Page 3 of 4
CX-WEC10BK2 Emergency Door Control Kit
INSTALLATION INSTRUCTIONS
5. WIRING DIAGRAM
4
3
Filename:C X-W EC 10BK2-W iring.ai
DRAWING No: CX-WEC-10BK2
WEC-10BK2 Restroom Assistance Required Wiring Diagram
SCALE: NONE DRAWN BY: JML REVISED:DATE:
Camden Door Controls
5502 Timberlea Blvd
Mississauga, Ontario
L4W 2T7
Part #: 40-82B243
CM-AF540SO
CM-SE21A
12/24
VDC/VAC
Power Supply
-V +V
N/O N/C
1
2
Mar 8/17
CM-AF142SO
BLACK
RED/GREEN/BLUE
1. Select the color of wire
for the desired color of LED.
Red, green or blue.
2. Tie all 3 wires (red,green and blue)
together to create a white light.
Feb 10, 2020
CORRIDOR RESTROOM
4. DOUBLE GANG CM-AF540SO MOUNTING
CM-AF540SO
Flush Mount
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
A.OLISA MAR-20 Double Gang
CM-AF540SO mounting
Exploded
CM-AF540SO
Wall

Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
Opening New Doors to
Innovation, Quality and Support!
Page 4 of 4
CX-WEC10BK2 Emergency Door Control Kit
INSTALLATION INSTRUCTIONS
File: CX-WEC10BK2 Manual.indd
Rev.: May 20, 2020
Part No.: 40-82A014
ORDERING INFORMATION FOR REPLACEMENT PARTS
Item Part Number Description
1CM-SE21A English Solid white WEC Sign 6’’ x 10-5/8’’
CM-AF142SO
260-31A081 Red Green Blue LED PCB Board 18-30 VAC/VDC
360-42K003 Single Gang Dress Plate
460-42C027-A Plastic-Dome Lens with English Label ‘’Assistance Required’’
560-42C027F-A Plastic-Dome Lens with French Label
660-42C027FE-A Plastic-Dome Lens With French & English Labels
760-81A010-BK 6"x 2" Clear Lexan .010 Print Black English Label
860-81A012 6"x 2" Clear Lexan .010 Print Red English Label
960-81A005 6"x 2" Clear Lexan .010 Print Red French Label
10 60-81A004 6"x 2" Clear Lexan .010 Print Red Bilingual Label
CM-AF142SO Parts Kit
11 60-34B089
6-32 x 3/4 Flat Head Phillips Zinc Plated Screw (2 pcs)
#6 x 3/4" Steel Pan Head Phillips Zinc Screw (2 pcs)
5/16’’ Phillips Rounded Head Screws (1 piece)
Yellow/Grey Plastic Anchors 3/16" (2 pcs)
Expanded Green PVC Anchors 10-24 Screw (2 pcs)
Grey Plastic Wire Nut c/w Spring (4 pcs)
Cut Cord (EPDM Durometer Cord CM-AF141SO) (1 piece)
CM-AF540SO
12 60-66C000 Normally Open Contact Block
13 60-66C001 Normally Close Contact Block
14 60-66C002 Normally Open & Normally Close Contact Block
CM-AF540SO Parts Kit
15 60-34B083
6-32 x 3/4 Phillips Oval Head Stainless Steel Screw (4 pcs)
Snake Eye Tamper Proof Screw 6-32 x 3/4" (4 pcs)
Key for Tamper Proof Screws (Snake Eye) (1 pc)
Grey Plastic Wire Nut C/W Spring (2 pcs)
This manual suits for next models
5
Other CAMDEN Security System manuals
Popular Security System manuals by other brands

Honeywell
Honeywell LYNXR-I Series Programming guide

Assa Abloy
Assa Abloy MSL mFlipLock check Assembly and operating instructions

Pyle
Pyle PLCMTR74 user manual

Optimus
Optimus Compact Installation and operating instructions

Lightinthebox
Lightinthebox GS-G90E instruction manual

DSC
DSC PC 4010 instruction manual

Swann
Swann PRO-580 Specifications

Direct Supply
Direct Supply Attendant owner's manual

Guardian Safety Pendants
Guardian Safety Pendants ProTec Quick start user guide

American Dynamics
American Dynamics MegaPower 3200 installation guide

Whelen Engineering Company
Whelen Engineering Company SCSS85 installation guide

Linear
Linear Security DUAL 824 installation instructions