Page 2- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Function of buttons
Press this button to activate and deactivate communication.
To send a PANIC SIGNAL to the porter (where present), press and hold the button for
more than 2 seconds.
The white LED will light up to confirm that the PANIC SIGNAL has been received by
the porter.
☞
The white LED stays on until the porter calls the user back.
The PANIC SIGNAL takes priority over all other types of call.
LED key
Flashing: call in progress
On: PANIC SIGNAL in progress (no receiver communication)
General precautions
• Read the instructions carefully before beginning the installation and carry out
the procedures as specified by the manufacturer. • The product must be installed,
programmed, commissioned and serviced by qualified technicians, correctly trained
with regard to respecting the regulations in force, including implementing accident-
prevention measures. • Before carrying out any cleaning or maintenance operation,
disconnect the power supply. • The equipment must only be used for the purpose for
which it was designed. • The manufacturer declines all liability for any damage as a
result of improper, incorrect or unreasonable use.
•
The product, in its original packaging
supplied by the manufacturer, must only be transported in a closed environment (railway
carriage, containers, closed vehicles).
•
If the product malfunctions, stop using it and
contact customer services at https://www.came.com/global/en/contact-us or via the
telephone number on the website.
The manufacture date is provided in the production batch printed on the product
label. If necessary, contact us at https://www.came.com/global/en/contact-us.
The general conditions of sale are given in the ocial CAME price lists.

Page 3- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Press this button to adjust the ringtone volume: LOW, MEDIUM, HIGH, OFF.
LED key red
On: the volume is o.
☞
Press the button during a conversation to adjust the audio volume.
Auxiliary 2 / Porter call.
This signals a request to be called back by the porter.
This button sends a DOOR RELEASE or GATE RELEASE command. To send a GATE
RELEASE command to the porter (where the function is enabled), press and hold the
button for more than 3 seconds.
LED key
Flashing: calling
On: gate/door open, if correctly configured.
The door status function is active by default. The GATE RELEASE function must
be correctly configured.
The function of this button depends on the configuration set during installation.
If the button is configured as an INTERCOM, it will serve as INTERCOM 1.
If the SECOND FUNCTION is also activated using button 4, it will serve as
INTERCOM 4.
If the button is configured as an AUX, it will serve as AUX 1.
The function of this button depends on the configuration set during installation.
If the button is configured as an INTERCOM, it will serve as INTERCOM 2.
If the SECOND FUNCTION is also activated using button 4, it will serve as
INTERCOM 5.
If the button is configured as an AUX, it will serve as AUX 3.
The function of this button depends on the configuration set during installation.
If the button is configured as an INTERCOM, it will serve as INTERCOM 3.
If the SECOND FUNCTION is also activated using button 4, it will serve as
INTERCOM 6.
If the button is configured as an AUX, it will serve as AUX 4.

Page 4- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Standard functions
Call in progress. Answer a call.
Communication activated.
Open the door for the calling entry panel.
End the call.
The function of this button depends on the configuration set during installation.
If the button is configured as an INTERCOM, it will temporarily enable the
SECOND FUNCTION, allowing INTERCOM calls 4 to 6 to be activated.
☞When the second function is active, the white LEDs on the buttons 1,2,3,4
will flash. The function remains active for approximately 10 seconds and can be
disabled by pressing the button again.
If the button is configured as an AUX, it will serve as AUX 5.
To enable and disable the AUTOMATIC DOOR RELEASE function, press and hold
the button for more than 3 seconds.
☞This function is available only when the line is free.
LED key
On: AUTOMATIC DOOR RELEASE function enabled.
O: AUTOMATIC DOOR RELEASE function disabled.

Page 5- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Intercommunication
Press the button to select the desired
internal receiver.
The calling receiver will sound to indicate
that the line is free.
The called receiver will ring with the
chosen ringtone.
Press this button on the called receiver to
activate audio communication.
☞During a conversation between internal receivers, a call from an entry panel is signalled
on the internal receivers by a beep that repeats every 5 seconds.
☞When trying to make an intercom call, 3 consecutive beeps indicate that the line is busy
and the call cannot be made.

12
Page 6- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Call forwarding
With a call active, select the internal receiver to which you want to transfer the call.
Auxiliary controls
Press the AUX button to activate the desired
auxiliary command.
Example switching on a light or opening
the gate.
☞Accessory devices may be required for
these commands to work properly.

12
12
12
Page 7- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
To activate audio communication between two internal receivers, press this button on the
called receiver.
The entry panel will be put on hold.
To allow internal receiver 2 to communicate with the entry panel, press this button on
internal receiver 1.
Int. 1 Int.2
Internal receiver 2 will be able to communicate with the entry panel.
☞The internal receiver with the incoming call can transfer it.

CONTACT ME
CONTACT ME
Contact me
Page 8- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Porter functions
These functions are only available if the system has a porter desk.
Call notification from the porter
When this button LED lights up, this means
the porter would like to be called back.
☞The LED turns o when communication
with the porter starts.
Request to be called back by the porter
Press this button to send a call request
signal to the porter.
☞ The system must be correctly
configured.

PANIC!
ALARM!
Page 9- Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Alarm signal
If an alarm contact connected to the
relevant receiver entrance is activated,
a signal is sent to the porter and an
intermittent acoustic signal sounds on the
receiver.
Sending a panic signal to the porter
Press and hold this button for 2 seconds to
send a PANIC signal to the porter.
The white LED indicates that the signal has
been received by the porter.

Page 10 - Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Automatic door-release function
Door status function
The LED next to this button indicates the
current door status.
☞The system must be correctly set up.
☞The function is active during the steps
that involve communicating with the entry
panel and the signal refers to the entrance
associated with the entry panel.
This function allows you to automatically
open the entrance when you press the call
button on the entry panel.
This function is useful for professional
practices.
Press and hold this button for more than
3 seconds to enable/disable the function.
☞The LED switches on to indicate that the
function has been enabled.
☞The call ends automatically.
Open-gate function/status
Press and hold the button for a prolonged
period to send an open/close command to
an operator. The LED indicates the status
of the operator.
☞ The system must be correctly set up
and configured.
☞The function must be activated on the
receiver when the call is being associated
during system programming.

3 sec
... beep!
Page 11 - Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Configuring melodies
☞Perform each of the following configuration steps, in succession:
Entering configuration mode
Press and hold the button for 3 seconds.
A short buzzing sound and a red flashing
LED confirm that you have entered
configuration mode.
Configuration the melody associated
with a call from the entry panel
Press this button to listen to the melodies
in sequence.

Page 12 - Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Configuration the melody associated
with a call from the landing.
Press this button to listen to the melodies
in sequence.
Press this button to select the melody and
exit configuration.
Press this button to select the melody and
continue configuration.
☞ You will hear two short beeps to
confirm that you have entered landing-call
configuration mode

Page 13 - Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Press this button to select the melody and
exit configuration.
Press this button to select the melody and
continue configuration.
☞ You will hear three short beeps
to confirm that you have entered
configuration mode for the number of
rings per call.
Configuration the number of rings per
call.
Press this button as many times as the
number of rings you want (from 1 to 12
rings).
Three seconds after the key was last
pressed, the selected call is played back
with the chosen number of rings.

Page 14 - Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Press this button to exit configuration.
Technical data
Type PLX A
Power supply from BUS (V DC) 15 to 20
Consumption in stand-by mode (mA) <1
Maximum consumption (mA) 30
Single LED consumption (mA) 1
Storage temperature (°C)* -25 to +70
Operating temperature (°C) +5 to +40
IP Rating IP 30
Average life (hours)** 150,000
(*) Before installing the product, keep it at room temperature where it has previously been
stored or transported at a very high or very low temperature.
(**) The average product life is a purely indicative estimate. It applies to compliant usage,
installation and maintenance conditions. It is also influenced by other factors, such as
climatic and environmental conditions.

Page 15 - Manual FA01624-EN - 03/2022 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Dismantling and disposal. Dispose of the packaging and the device responsibly at the end
of its life cycle, in compliance with the laws in force in the country where the product is used.
The recyclable components are marked with a symbol and the material ID marker.
THESE INSTRUCTIONS MUST BE SUPPLIED WITH THE DEVICE. THE DATA AND INFORMATION CONTAINED IN THEM ARE TO BE
CONSIDERED AS SUBJECT TO CHANGE AT ANY TIME AND WITHOUT THE NEED FOR ANY ADVANCE WARNING.
Legislative references
This product complies with the applicable standards in force at the time of manufacturing.
FCC - This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference / (2) this device must accept any
interference received, including interference that may cause undesired operation.
Cleaning the device
To clean the device, use a soft, slightly damp cloth only. Wet the cloth with water or an ammonia
solution. Alternatively, use an oil-based soap (e.g. Marseille soap) or a gentle makeup remover (e.g.
a cleanser or micellar water).
Always wipe the surface with a damp cloth (wet with just water) after cleaning. Never use
alcohol-based solutions or solutions containing surfactants.

CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 16 - Manual FA01624-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Table of contents
Other CAME Intercom System manuals

CAME
CAME AGT V User manual

CAME
CAME 001DC02ENIGMA User manual

CAME
CAME Wi-Fi PLX V Specification sheet

CAME
CAME PLACO-VC User manual

CAME
CAME STLCDFN User manual

CAME
CAME XTS 7IP WH WIFI User manual

CAME
CAME AGT V Specification sheet

CAME
CAME Bpt TARGHA GSM VR1 User manual

CAME
CAME 001DC00EGMA11 User manual

CAME
CAME BPT PEC User manual

CAME
CAME XTS 7 WH WIFI Manual

CAME
CAME QBESetUp Owner's manual

CAME
CAME PLACO-VC User manual

CAME
CAME LVC/01 Owner's manual

CAME
CAME XVP S User manual

CAME
CAME XTS 7IP BK WIFI Manual

CAME
CAME KIT AGT V + LITHOS User manual

CAME
CAME XTS 7 WH WIFI User manual

CAME
CAME BPT KIT FREE DVC Series User manual

CAME
CAME VK01 User manual