manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Caple
  6. •
  7. Wine Cooler
  8. •
  9. Caple WI3118WH Manual

Caple WI3118WH Manual

Other Caple Wine Cooler manuals

Caple WF1103 User manual

Caple

Caple WF1103 User manual

Caple WI3126 User manual

Caple

Caple WI3126 User manual

Caple Wi6116 Manual

Caple

Caple Wi6116 Manual

Caple Wi6223 User manual

Caple

Caple Wi6223 User manual

Caple WI6155 User manual

Caple

Caple WI6155 User manual

Caple WI6134 User manual

Caple

Caple WI6134 User manual

Caple WI3119 User manual

Caple

Caple WI3119 User manual

Caple WI3116 Manual

Caple

Caple WI3116 Manual

Caple Wi6129 User manual

Caple

Caple Wi6129 User manual

Caple WI152 User manual

Caple

Caple WI152 User manual

Caple WI6161 User manual

Caple

Caple WI6161 User manual

Caple WI6127 Manual

Caple

Caple WI6127 Manual

Caple WI6115 Manual

Caple

Caple WI6115 Manual

Caple WF1544 User manual

Caple

Caple WF1544 User manual

Caple WI6142 User manual

Caple

Caple WI6142 User manual

Caple Wi6128 User manual

Caple

Caple Wi6128 User manual

Caple WI158 User manual

Caple

Caple WI158 User manual

Caple WC177 User manual

Caple

Caple WC177 User manual

Caple WI6119 Manual

Caple

Caple WI6119 Manual

Caple Wi6222 User manual

Caple

Caple Wi6222 User manual

Caple WI6118 User manual

Caple

Caple WI6118 User manual

Caple WF1102 User manual

Caple

Caple WF1102 User manual

Caple Wi6114 Manual

Caple

Caple Wi6114 Manual

Caple WC177 Manual

Caple

Caple WC177 Manual

Popular Wine Cooler manuals by other brands

Sub-Zero WS-30 Specification sheet

Sub-Zero

Sub-Zero WS-30 Specification sheet

Rotel U903CH1 Instructions for use

Rotel

Rotel U903CH1 Instructions for use

Esatto EWC46 quick start guide

Esatto

Esatto EWC46 quick start guide

Sub-Zero Classic Series installation guide

Sub-Zero

Sub-Zero Classic Series installation guide

U-Line Echelon Wine Captain 2075WC Features & benefits

U-Line

U-Line Echelon Wine Captain 2075WC Features & benefits

Haier WS50GA user manual

Haier

Haier WS50GA user manual

Cavist 62 instruction manual

Cavist

Cavist 62 instruction manual

Kenmore 461.99130 owner's manual

Kenmore

Kenmore 461.99130 owner's manual

Danby DWC113BLSDB owner's manual

Danby

Danby DWC113BLSDB owner's manual

Avanti WC1001 instruction manual

Avanti

Avanti WC1001 instruction manual

Frigidaire FFWC38F6LS Factory parts catalog

Frigidaire

Frigidaire FFWC38F6LS Factory parts catalog

Titan TT-W2454SZ User guide & service manual

Titan

Titan TT-W2454SZ User guide & service manual

Klarstein Botella 166 Uno manual

Klarstein

Klarstein Botella 166 Uno manual

Costway FP10130WL manual

Costway

Costway FP10130WL manual

Lemair LWC59 instruction manual

Lemair

Lemair LWC59 instruction manual

Vinvautz VZ08BHK user manual

Vinvautz

Vinvautz VZ08BHK user manual

Haier JC-125GEA user manual

Haier

Haier JC-125GEA user manual

Climadiff CLI24 use instructions

Climadiff

Climadiff CLI24 use instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

WI3118WH
Ca
p
le
30cm
1
zone
wine
cabinet
Caple 30cm 1 zone wine cabinet
Technical information
Item Part Code Description Qty
1DG11-45 Dry filter 1
2DG2-14 Power cord 1
3DG1-72 Compressor 1
4DG13-199 Water tank 1
5DG13-272-1 PCB board cover 1
6DG6-7 Transformer 1
7DG3-98-12 PCB board 1
8DG26-133-1 Cabinet 1
9DG13-268 Decorative nail 3
10 DG13-257 Evaporator fixing nip 2
11 DG14-190-SR Top right hinge 1
12 DG12-44-2 Evaporator 1
13
DG13 158 1
Surpport pole
1
WI3118WH
- Caple 30cm 1 zone wine cabinet
13
DG13
-
158
.
1
Surpport
pole
1
14 DG20-1 Wire nip 1
15 DG7-3.1-BH Evaporator fan 1
16 DG13-158 Surpport pole 1
17 DG22-209 Air duct board 1
18 DG13-198 Senser cover 1
19 DG8-8 Sense
r
1
20 DG19-1 Fan cove
r
1
21 DG3-12-W LED light 1
22 DG22-395 Electrical box 1
23 DG13-327 Display support 1
24 DG13-1.2 Water tank 1
25a DG15-26.1 Wooden shelves A15A 1
25b DG15-25 Stainless steel edged 5
26 DG23-242-3 Doo
r
1
27 DG22-3057 Door axis 1
28 DG15-27 Wooden shelves C1 1
29 DG15-26 Wooden shelves A15A 4
30 DG20-317 Display panel 1
31 DG13-130-S Button 4
32 DG13-383 Electrical box panel 1
33 DG13-353 Sealing piece 1
34 DG14-212-SR Lower right hinge 1
35 DG22-40 Support bracket of front legs 1
36 DG13-6.11 Cabinet leg 4
37
DG22
-
39
Compressor bracket
1
37
DG22 39
Compressor
bracket
1
38 DG12-3 Condense
r
1
39 DG7-3.2-BH Condenser fan 1
40 DG19-3 Fan cove
r
1
Item Part Code Description Qty
WI3118WH
- Caple 30cm 1 zone wine cabinet
41 DG14-33 Fan fixing piece 2
42 DG12-58
A
ir-circulating pipe 1
43 M184-041 Gasket 1
44 DG22-3027 Handle 1
ADG14-190-SL Top left hinge 1
BDG14-212-BL Lower left hinge 1
CDG22-3022 Bottom grill 1
DDG22-3055-1 Bottom grill 1
EDG22-3145 Bottom grill bracket 2
WI3118WH
Ca
p
le
Sin
g
le
zone
wine
cabinet
Caple Single zone wine cabinet
Service Manual
1
SERVICEMANUAL
(One temperaturezone controlwinecoolar)
JGseriesincludesJG18 series,JG32B,JG45AJG50A,JG50A-1,JG50FA
Thecontentbelowshowsdifferentdefault mighthappenwhenthewinecoolerisworking,andalsoshowshowto
find thedefaultsandrepairthedefaults.Pleasefindthecorrespondingdefault statementandfindtherepair
informationinthecorresponding pages.
Statement:(Fig.4)shows thecorrelativediagramFig.4
( 6)shows thecorrelativepage6
WARNING:BeforeattemptinganycleaningormaintenancethisunitMustbedisconnectedformthe
electricalsupply, topreventelectricalshock.
▲Preparationbeforemaintenance
○Tools
1. Pliers
2. Phillipsheadscrewdrivers
3. Process pipe
4. ElectricalMultimeter
5.Ampmeter(5A)(calipercable type)
6. Electricalsolderingiron
7.Wirestrippers
8. Sealpliers
9/Scissors
○Equipment
1. Vacuumpump
2.Soldering ironforcopperpipes
3.Gas meter
▲Coolingsystemfault
○HowtoEvaluate thefault ... (Page 3)
○Howtorepairthefault (Page 3)
○Howtoremove theairductboard.. . (Page4)
○Diagramshowingthefrontside solderedjoints.. (Page 6)
○Diagramshowingthe rearside solderedjoints (page 7)
▲Noise problems
○Compressornoise. .. (Page 8)
○Fannoise.. .(Page 8)
○Refrigerantjetnoise... ... (Page 9)
○Capillaryvibrationnoise... ... . ... (Page 9)
○Oiljamnoise.. ... . (Page10)
▲Evaporatorfreezingproblems .(Page 10)
2
▲Unstableinternaltemperatureproblems .(Page 12)
▲Controlsystemproblems
○Faultfindingbythe self-checkmode ..(Page 12)
○Sensorfault ...(Page 12)
○LEDdisplayfault..(Page14)
○Howtoremove theelectricalbox. (Page 14)
○Thedismantlementmethod oftheelectricalboxspearpart. . (Page 14)
○Howtoreplace thelight .. (Page16)
○Howtoreplace theDecorativeframe .. (Page17)
3
△Coolingsystemfaults.
○Howtodiagnosefaults:
Itshouldtakeapproximate3hourstoreachthelowestsettingtemperatureof5℃foranemptyunit(assuming ambient
tempof32degreescentigradeandcontinuousoperation). Ifnot,checkthecompressor,coolingfans,controller, andsensors.
Ifall theseareworking normally,thereisprobablyacoolingsystem’sfault.
○Howtorepairthedefualt
1. Checkthe compressor
Turnonthe unitandcheckthere iselectricitycurrentflowingtothecompressorusinga calipertypeAmpmeter,the
currentshouldbewithin0.6to2Amps.Ifthereadingsarenotinthisrange, turnoffandcutoffthepipes (See Fig.8
showingG) andthesealpliers (See Fig.8showing E.) fromthecompressor,thenturntheunit onagain(inthiscase
onlyrun thecompressorforafewminuets,soastoavoidthecompressorabsorbmoistair)andrecheckthe
currentand ifthereispressureattheoutletpipe. Ifthecurrentreadingisstill outofrangespecifiedaboveandno
pressurefromthe compressoroutlet, replace the whole compressor.
2. Checkthecoolingsystempipe work:
Carefullycheckthecooling systemafterverifying thecompressorisworking normally.Thenfollowtheprocedure
below.
1>. Thencutoffprocess pipeandchecktherefrigerant.Ifthereisnotenoughrefrigerant,thedefualt oftherefrigerant
systemshouldbecausedbytheleaking.Ifthe refrigerantissufficient., itisprobablyjamedinthecapillary.
2>.Ifthedefault is concentratedon thecooling system,thechecking procedureis as below.
A.Cutoff theventpipeofthecompressor, andinfuse0.8-1MPnitrogenby process pipe, andpleaseputthehandclose
tothecutkerfoftheventpipe.Ifthereis alittlegas leakformtheterminal,it meansnormal, orit is jamed.
B. Makesurethecapilaryisworkingnormally,whenthedrainpipeisconnetcedagain,and infuse0.8-1MPnitrogen
thentesttheleakageifthecoolingsystemofthesoldering pointwiththesoapwater.Checkfromthethesoldering
pointarroundthecompressor(Fig.8&Fig.9、Fig.9.1),andifeverythingis ok,removetheair-ductboardand chech
thesoldering pointaround evaporator(Fig.6 &Fig.7).pleaseseetheremovemethodand theprocedureasbelow.
(Fig.1,Fig.2,Fig.3,Fig.4&Fig.5)
C.IfallthesolderingpointinB isnotleaking,therearetwopossibility, oneis leakageintheinnercondenser,another
isthedamageon theparts(suchas evaporator,condenserand soon)inthecoolingsystem.Ifitis theinnerdamage,
itcannotberepaired,andifthedamageontheparts, replace them.
3>.Makesurethatthereis notleakageinthecooling system, refilltherefrigerant.
3.Refillthe refrigerant:
1>. Using thevacuumpumpforma vacuuminthesystem,via the jointofthelow-pressureprocesspipeonthecompressor,
thehigh-pressurepipelineisontheprocess pipeofthefilter.Applythevacuumpumpforapproximately20 minutes.Until
thevacuumislowerthan100Pa.Thensolderthecompressorprocess pipeofthefilter.Keepthevacuumrunningwhile
solderingthisjoint
2>.FillCooling systemwithrefrigerantviatheprocesspipe. (TherefrigerantisR134a.Regardingrefrigerantquantity
Pleaserefertotheinstructionatbacklabelofwinecellar).Thensolderthecompressorprocess pipeafterthesystemis
chargedwithrefrigerant.
4.Running test:
Replaceall thecomponentsaftertheproceduresaboveandturntheuniton.Toverifytheeffectiveness oftherepair,
monitor
4
theunit thecompressorshouldautomaticallystopwithin-2.5degcentigradeofthesettemperatureandstartwith+2.5deg
centigradeofthe settemperaturewithinapprox3hours(assuminganambienttemperatureof32℃andtheunit isempty).
○Howtoremovethe airduct board.
1.Removetheshelvesfirstly.
a. Remove theshelves;somemodelshavePhillipsheadscrewstoholdothermodelshavenoscrews (Fig.1)
Fig.1
②. Pull theshelvestothebottom,circumvolveanysideoftherightandleft,andletthesetter
oftheshelvegooutofthechannel, andthendrawouttheshelves. (Fig.2)
Fig.2