Caple WI3118WH Manual

WI3118WH
Ca
p
le
30cm
1
zone
wine
cabinet
Caple 30cm 1 zone wine cabinet
Technical information


Item Part Code Description Qty
1DG11-45 Dry filter 1
2DG2-14 Power cord 1
3DG1-72 Compressor 1
4DG13-199 Water tank 1
5DG13-272-1 PCB board cover 1
6DG6-7 Transformer 1
7DG3-98-12 PCB board 1
8DG26-133-1 Cabinet 1
9DG13-268 Decorative nail 3
10 DG13-257 Evaporator fixing nip 2
11 DG14-190-SR Top right hinge 1
12 DG12-44-2 Evaporator 1
13
DG13 158 1
Surpport pole
1
WI3118WH
- Caple 30cm 1 zone wine cabinet
13
DG13
-
158
.
1
Surpport
pole
1
14 DG20-1 Wire nip 1
15 DG7-3.1-BH Evaporator fan 1
16 DG13-158 Surpport pole 1
17 DG22-209 Air duct board 1
18 DG13-198 Senser cover 1
19 DG8-8 Sense
r
1
20 DG19-1 Fan cove
r
1
21 DG3-12-W LED light 1
22 DG22-395 Electrical box 1
23 DG13-327 Display support 1
24 DG13-1.2 Water tank 1
25a DG15-26.1 Wooden shelves A15A 1
25b DG15-25 Stainless steel edged 5
26 DG23-242-3 Doo
r
1
27 DG22-3057 Door axis 1
28 DG15-27 Wooden shelves C1 1
29 DG15-26 Wooden shelves A15A 4
30 DG20-317 Display panel 1
31 DG13-130-S Button 4
32 DG13-383 Electrical box panel 1
33 DG13-353 Sealing piece 1
34 DG14-212-SR Lower right hinge 1
35 DG22-40 Support bracket of front legs 1
36 DG13-6.11 Cabinet leg 4
37
DG22
-
39
Compressor bracket
1
37
DG22 39
Compressor
bracket
1
38 DG12-3 Condense
r
1
39 DG7-3.2-BH Condenser fan 1
40 DG19-3 Fan cove
r
1

Item Part Code Description Qty
WI3118WH
- Caple 30cm 1 zone wine cabinet
41 DG14-33 Fan fixing piece 2
42 DG12-58
A
ir-circulating pipe 1
43 M184-041 Gasket 1
44 DG22-3027 Handle 1
ADG14-190-SL Top left hinge 1
BDG14-212-BL Lower left hinge 1
CDG22-3022 Bottom grill 1
DDG22-3055-1 Bottom grill 1
EDG22-3145 Bottom grill bracket 2


WI3118WH
Ca
p
le
Sin
g
le
zone
wine
cabinet
Caple Single zone wine cabinet
Service Manual

1
SERVICEMANUAL
(One temperaturezone controlwinecoolar)
JGseriesincludesJG18 series,JG32B,JG45AJG50A,JG50A-1,JG50FA
Thecontentbelowshowsdifferentdefault mighthappenwhenthewinecoolerisworking,andalsoshowshowto
find thedefaultsandrepairthedefaults.Pleasefindthecorrespondingdefault statementandfindtherepair
informationinthecorresponding pages.
Statement:(Fig.4)shows thecorrelativediagramFig.4
( 6)shows thecorrelativepage6
WARNING:BeforeattemptinganycleaningormaintenancethisunitMustbedisconnectedformthe
electricalsupply, topreventelectricalshock.
▲Preparationbeforemaintenance
○Tools
1. Pliers
2. Phillipsheadscrewdrivers
3. Process pipe
4. ElectricalMultimeter
5.Ampmeter(5A)(calipercable type)
6. Electricalsolderingiron
7.Wirestrippers
8. Sealpliers
9/Scissors
○Equipment
1. Vacuumpump
2.Soldering ironforcopperpipes
3.Gas meter
▲Coolingsystemfault
○HowtoEvaluate thefault ... (Page 3)
○Howtorepairthefault (Page 3)
○Howtoremove theairductboard.. . (Page4)
○Diagramshowingthefrontside solderedjoints.. (Page 6)
○Diagramshowingthe rearside solderedjoints (page 7)
▲Noise problems
○Compressornoise. .. (Page 8)
○Fannoise.. .(Page 8)
○Refrigerantjetnoise... ... (Page 9)
○Capillaryvibrationnoise... ... . ... (Page 9)
○Oiljamnoise.. ... . (Page10)
▲Evaporatorfreezingproblems .(Page 10)

2
▲Unstableinternaltemperatureproblems .(Page 12)
▲Controlsystemproblems
○Faultfindingbythe self-checkmode ..(Page 12)
○Sensorfault ...(Page 12)
○LEDdisplayfault..(Page14)
○Howtoremove theelectricalbox. (Page 14)
○Thedismantlementmethod oftheelectricalboxspearpart. . (Page 14)
○Howtoreplace thelight .. (Page16)
○Howtoreplace theDecorativeframe .. (Page17)

3
△Coolingsystemfaults.
○Howtodiagnosefaults:
Itshouldtakeapproximate3hourstoreachthelowestsettingtemperatureof5℃foranemptyunit(assuming ambient
tempof32degreescentigradeandcontinuousoperation). Ifnot,checkthecompressor,coolingfans,controller, andsensors.
Ifall theseareworking normally,thereisprobablyacoolingsystem’sfault.
○Howtorepairthedefualt
1. Checkthe compressor
Turnonthe unitandcheckthere iselectricitycurrentflowingtothecompressorusinga calipertypeAmpmeter,the
currentshouldbewithin0.6to2Amps.Ifthereadingsarenotinthisrange, turnoffandcutoffthepipes (See Fig.8
showingG) andthesealpliers (See Fig.8showing E.) fromthecompressor,thenturntheunit onagain(inthiscase
onlyrun thecompressorforafewminuets,soastoavoidthecompressorabsorbmoistair)andrecheckthe
currentand ifthereispressureattheoutletpipe. Ifthecurrentreadingisstill outofrangespecifiedaboveandno
pressurefromthe compressoroutlet, replace the whole compressor.
2. Checkthecoolingsystempipe work:
Carefullycheckthecooling systemafterverifying thecompressorisworking normally.Thenfollowtheprocedure
below.
1>. Thencutoffprocess pipeandchecktherefrigerant.Ifthereisnotenoughrefrigerant,thedefualt oftherefrigerant
systemshouldbecausedbytheleaking.Ifthe refrigerantissufficient., itisprobablyjamedinthecapillary.
2>.Ifthedefault is concentratedon thecooling system,thechecking procedureis as below.
A.Cutoff theventpipeofthecompressor, andinfuse0.8-1MPnitrogenby process pipe, andpleaseputthehandclose
tothecutkerfoftheventpipe.Ifthereis alittlegas leakformtheterminal,it meansnormal, orit is jamed.
B. Makesurethecapilaryisworkingnormally,whenthedrainpipeisconnetcedagain,and infuse0.8-1MPnitrogen
thentesttheleakageifthecoolingsystemofthesoldering pointwiththesoapwater.Checkfromthethesoldering
pointarroundthecompressor(Fig.8&Fig.9、Fig.9.1),andifeverythingis ok,removetheair-ductboardand chech
thesoldering pointaround evaporator(Fig.6 &Fig.7).pleaseseetheremovemethodand theprocedureasbelow.
(Fig.1,Fig.2,Fig.3,Fig.4&Fig.5)
C.IfallthesolderingpointinB isnotleaking,therearetwopossibility, oneis leakageintheinnercondenser,another
isthedamageon theparts(suchas evaporator,condenserand soon)inthecoolingsystem.Ifitis theinnerdamage,
itcannotberepaired,andifthedamageontheparts, replace them.
3>.Makesurethatthereis notleakageinthecooling system, refilltherefrigerant.
3.Refillthe refrigerant:
1>. Using thevacuumpumpforma vacuuminthesystem,via the jointofthelow-pressureprocesspipeonthecompressor,
thehigh-pressurepipelineisontheprocess pipeofthefilter.Applythevacuumpumpforapproximately20 minutes.Until
thevacuumislowerthan100Pa.Thensolderthecompressorprocess pipeofthefilter.Keepthevacuumrunningwhile
solderingthisjoint
2>.FillCooling systemwithrefrigerantviatheprocesspipe. (TherefrigerantisR134a.Regardingrefrigerantquantity
Pleaserefertotheinstructionatbacklabelofwinecellar).Thensolderthecompressorprocess pipeafterthesystemis
chargedwithrefrigerant.
4.Running test:
Replaceall thecomponentsaftertheproceduresaboveandturntheuniton.Toverifytheeffectiveness oftherepair,
monitor

4
theunit thecompressorshouldautomaticallystopwithin-2.5degcentigradeofthesettemperatureandstartwith+2.5deg
centigradeofthe settemperaturewithinapprox3hours(assuminganambienttemperatureof32℃andtheunit isempty).
○Howtoremovethe airduct board.
1.Removetheshelvesfirstly.
a. Remove theshelves;somemodelshavePhillipsheadscrewstoholdothermodelshavenoscrews (Fig.1)
Fig.1
②. Pull theshelvestothebottom,circumvolveanysideoftherightandleft,andletthesetter
oftheshelvegooutofthechannel, andthendrawouttheshelves. (Fig.2)
Fig.2

5
③. Driveuptheshelvesmakeit abovethefixer1 (Fig.3),then takeitout according tothearrowhead
Fdirection(Fig.4)
Fig.3
Fig.4
2>.Howtoremovetheairductboard(A).(inFig.51~10arethescrewsfixingtheairductboard,in
differenttypes,thesituationsand quantityofthemaredifferent,A~Darethescrewsfixingthefan,noneed
toremove),Removethefixingscrewsofairductboard(1,2,3,4,5,6,7,8,9,10),thenpulloutairductboard(A).
See (Fig5)
Beattentiontounplugtheconnectionwirewhenremoving theair-ductboard.Youcanmoveslowlyaside
untilyou cansee thefans wire,andunplugit, andthentakeoutthewholeair-ductboard. ;
Fig.5

6
3>.ForaViewofthe internalconfigurationafterremovalofthe airductboard,see (Fig.6&Fig.7)
○Diagramshowingthefrontsidesolderedjoints(Therearetwodifferenttypesofevaporator:Finnedandpipe
evaporator,se (Fig.6&Fig.7)
A.CapillarysolderedjointsB.evaporatorsolderedjoints
Fig.6
Finnedevaporator
Fig.7
Pipe boardevaporator

7
○Diagramshowingtherearsidesolderjoints.Therearetwodifferentcondensers:built-in(Fig.8) and outboard
condenser).See (Fig.9&Fig.9.1)
B: Dryfilterprocess pipesolderedjoint C: Dryfiltersolderedjoint D: Capillarysolderedjoint
E: Process pipesolderedjoint F: Suction pipesolderedjoint G: Dischargepipesolderedjoint
H: Condenserprocesspipesolderedjoint I: Anti-Dewpipesolderedjoint
Fig.8
Built-incondenser
Fig.9

8
Fig.9.1
Outboardcondenser
▲High noiseofwinecellar
○compressornoise
1.Theworking ofmotorand pistonmotionwill causenoisewhencompressorworking.Soifnoiseis
steadyandnotexceeds42 dB,it’snormal.If noiseisnotsteadyorveryhigh,it’scompressorfault andit
shouldberepairedorreplaced.
2.If compressor’sshockabsorptionrubberishardeningordamaged,orfixingscrewofcompressoristoo
tightorloose,it willcausenoise.Thesettlementistochangenewshockabsorptionrubberoradjustfixing
screws.
○Fannoise
1>. Normalfanmotorandairflowshouldnotexceed32dB.
2>. Ifthereis noiseabove32dBorthenoiselevels fluctuate, thefanshaftis eitherdamagedorworn.
3>. Howtoreplacethefans
Fig.10

9
a. Replacingtheevaporatorfan
1>.Removetheshelfholdefixing screws, andremovetheshelves. See (Fig.1,Fig.2,Fig.3,Fig.4)
2>.Removetheairductboard.See(Fig.5)
3>.Removethefanfixingscrews(1,2,3,4), and replace thefan.See (Fig.10)
b.Replacing thecondenserfan(differentmodelmayhavedifferentfanposition,buttheprocedurefor
replacementisthe same)
1>.Removeclip(A),thentakeoff the electricalboxcoverofthe compressor.See (Fig.11)
2>.Markthetwoendsofthepowercordofthefan(thisisimportanttoensurereplacementiscorrect),and
thenremovesthe powercords(C,D), (Thefigure isasper “ZEL”compressor;differentcompressor
mayhavedifferentpowercordpositions, see (Fig.11)
3>.Removethe twoscrewsunderthefan(1,2), andremove thecondenserfan.See (Fig.11)
4>.Removethefourfansecuring screws(3,4,5,6), and replacethefan. See (Fig.11.1)
5>.Re-assembletheunit
○Refrigerantjetnoise
Ifthereiscontinuousnoiselikeawatersprayfromthecapillary,theendofcapillaryisinthewrongposition,or
thereareroughedgesontheendofthecapillary.
1>.Heatthesolderedjointofthecapillary(AofFig.8and Fig.9,Fig.9.1),thenremovethecapillaryfromthe
evaporatorandsmooththeendwithaneraser(Caution:Donotallowanyparticlesintocapillaryunit
2>.Replace thecapillaryintotheevaporator,thensolderitbackintothecorrectposition(notexceeding
15mm intheevaporator) andpackthejointwithanti vibrationcompound
3>.Rechargewithrefrigerant.See (Page7)
○Capillaryvibrationnoise
Fault: Hightfrequencyimpactnoiseincapillaryzone
Causedbyeither:
1>.Thecapillarybeinginserttoodeepinttheevaporator,sowhentherefrigerantisjetting,theendof
vibration capillarywill hittheinsideoftheevaporator.
2>.Vibrationfrom thecapillarytouchigtheinsideofthecabinetorairductboard,thenwhenrefrigeranis
jetting.
Howtorepairthis problem

10
1>.De-solderthecapillaryandre-solderinthecorrectpositionavoiding contactwiththeinsideofthe
evaporator, (Thedepthshouldbewithin15mm), thenrechargetheunitwithrefrigerantsee (7)
2>.Ifthecapillarytouchestheinsideofthecabinetorairductboard,youshouldadjustpositionof
capillaryandpackit withanti-vibration compound. (Fig.8&Fig.9、Fig.9.1)
Oiljammednoise
Fault:intermittentanddeepjetnoisecomingfrom insideofthecapillary.
Causedby:Compressoroil flowing intothecoolingsystempipeworkbecauseofwinecoolerleanduring
transportation, andthejetting oil inthecapillarycausenoise.
Solutions:
Cleanthecoolingsystempipe,and rechargewithrefrigerantsee (page7)
▲Evaporatorfreezing
○This is normallydueto
A/Poorsealbetweendooranddoorframe
B/Thedoornotclosedcorrectlyforalongperiodoftime
Thisallowsmoistairintothecabinet,whichfreezesintheevaporator,iftheiceisallowedtogettoothick,it
maydamagethefan.
1>. Ensuredoorissealedagainsttheframe,ifthereis slightdistortionoftheseal, heattheeffectedareagently
withahairdryergenrlysee (fig12) withsmoothstrokesofthehairdryer,thenwhenstillwarmpulltheeffected
area backintoitsoriginalposition,thisprocess mayhavetoberepeateduntilthesealiscompletelybacktoits
originalcondition.
Fig.12
2>.If theicehasdamagethefanit willneedtobereplacedsee. (Fig.10)
○Insomeoldermodels,theelectricalconnectorofthefanwiresisfixedundertheevaporator,andwater
from evaporatormaydripontothisjunctionbox,thismayeffecttheelectricalconnection,causingthefan
tostop.Whichinturncausessurfacefreezing.
1>.Removetheairductboardsee(Fig.1,Fig.2,Fig.3,Fig.4&Fig.5),removethecableclipsecuring
screws(A), andremovethecableclipsee (Fig.13)
2>. Cutoffthebothconnectorssee. (Fig.13.1)
3>.Striptheendsofthewiresabout12mmandre-connectthen.
Ensure thiselectricaljointissealedagainstfuturewaterdamage,and iselectricallysafe(Fig.14)

11
4>.Fixthewireinthecorrectpositionusing thecableclipwithscrew (Fig.15)
Fig.14
Fig.15
5>.Iffanis foult ,pleaserelacethewholefan.
6>.Note:theuppermethodonlyfortheconnectorfixedundertheevaporator.

12
▲Unstalbetemperatures insidethecabinet
Unstabletemperaturesinsidethecabinetismostlyduetoafault intheevaporatorfan,youcancheck
thisby:Whencompressorworks,the “RUN”indicatorlightshouldcomeonandthefanshouldspin,If
fandoesnotspincheckthefanselectricalconnectionsarefaultyandrepairthemorifthefanis
damagedreplace thewholefanunitsee (fig10).
▲Controlsystemfault.
○Usetheself-checkmodetocheckthisfault.
Thisserieswinecellarhasacomputerizedcontrollerwithbuilt inself-checkfunction.
Starttheself-checkmodeasfollows:
1>.Pressandhold “Setlower”and “Setupper”buttonwithpoweron.2beepswillsound,andthen
thecontrollerwillstarttheself-checkfunction
2>.If everythingisoperatingcorrectly:
a. Noresponsewhenpressing buttons.
b. TheLEDdisplayis: “——“
c. Thecompressorworksandthe “RUN”indicatorlightareonallthetime.
d. Thecondenserandevaporatorfans(Somemodelsdo nothaveevaporatorfan)workatfull
speed
e. Theswitchwhichcontrolsthelightfunctionsnormally
3>.If thecontrolpanelandthevariouscomponentsoftheunitdonotrespondasabove
Checkthefaultypartandrelevantconnection.If thisdoesnotcurethefaultreplacethecontrol
boardsee (Fig.18 &Fig.19)
4>.Ifyoureturnthecontrolpaneltoitsnormalworkingmode,pleasepullouttheplugandplugit
inagain
○Sensorfault
1>.NormallytheLEDtemperaturedisplayshouldtheambienttemperatureshortlyaftertheunit
ispluggedin,ifnot,disassembletheelectricalboxsee (fig18),checkifthesensorplug
marked “XI”“X10”connectedproperly,ifthesconnectionaremadecorrectlyandthefault
persistsreplacethissensoraftertheairductboard(Fig.1,Fig.2,Fig.3,Fig.4&Fig.5).
2>.If theLEDdisplays”E1””E2”,itindicatesthesensor “E1””E2,”shouldbereplacedthe
sensorontheevaporator(Fig.16,Fig.16.1)
3>.Takeoff thescrew(A)andcableclip(Fig.16);
4>.Cutoff thefaultsensor,pleasenotedthatdonotcuttoolongofwire(Fig.16.1);

13
5>. Striptheendsofthewires,cutoftheconnectofnewsensorandstriptheendsofwiresabout
12mm, re-connectthem.
Ensure thiselectricaljointissealedagainstfuturewaterdamage,and iselectricallysafe
Fixthewireinthecorrectpositionusing thecableclipwithscrew(Fig17& Fig17.1)
Fig.17
Fig.17.1
6>.If theLEDdisplays”E3””E4”,it indicatesthesensor “E3””E4,”shouldbereplacedthe
anti-frostsensorundertheevaporator(Thereplacementmethodisassameasbelow)
○Sincethelocation ofsensorontheoldmodelisdifference,checkthesensoras below:
1>.NormallytheLEDtemperaturedisplayshouldtheambienttemperatureshortlyaftertheunit
ispluggedin,ifnot, disassembletheelectricalboxsee (Fig.18&Fig.19), checkifthesensor
plugmarked “XI”connectedproperly,ifthisconnectionismadecorrectlyandthefault
persistsreplacethissensor,

14
2>.If theLEDdisplays”E1”it indicatestheinnersensorshouldbereplacedsee (Fig.18 &
Fig.19) 3>.If theLEDdisplays”E2”itindicatestheinnersensorshouldbereplacedsee (Fig.18&Fig.19)
4>.Forsomeoldermodelswitholdcomputerizedcontrolpanels,If theLEDdisplays37℃,99F
or,infinity,replacesthesensor.See(Fig.18& Fig.19)
○LEDdisplayerror
Replace theelectricaldisplayboardfault; see (Fig.18&Fig.19)
○Howtoremovetheelectricalbox.
1>.Removetheshelves;see (Fig.1,Fig.2,Fig.3,Fig.4)
2>.Removethetwoscrewsatbackofelectricalbox(2,3),thenhalf-removethetwofront
screws(1,4),thenremovetheelectricalbox;see (Fig.18)
Fig.18
3>.Removethesensorfixingscrew(1),unplugtheotherendfrom “X1”housing ofthecontrol
board,andfitanewsenor;see;(Fig19)
4>.Unplugalltheconnecters,thenpresstheheadofeachofthefourplasticscrews(4)oneby
one, thenremovethecontrolboardandreplace thecontrolboardsee (Fig.19)
5>.Removethetwotransformerfixing screwsandreplacethetransformer(6);(Fig.19)
6>.Toreplacingthedisplayboard,
Pullthefour4displaycover(8)fastenersasperarrowheaddirection,andthenremovethe
displayboardanditstwoconnectorsfrombothsides.Replace thedisplayboard.See
(Fig.19)
○Thedismantlementmethod oftheelectricalboxspearpart.
Therearetwotypeofelectricalbox,oldand divideversion.
PCBboardhas twomodes:
mode1 :PCB boardisacompleteblock,andintheelecticialboxofthesameboxwiththe
transformer;(Fig.19)
model2:PCB boarddivideinto2blocks,themainPCB boardisintheelectricalbox(Fig.22),theother
powerPCBboardisintheleftofthecompressor’s box withthetransformer. (Fig.21)
1>.Theoldstructureelectricalremovement.
Unplugall theconnectorsfromthe controlpanel, and pressthe4studs(4)onebyone, andupdrawthecontrolpanel,
Replaceit withthesamemodel’s PCB board; (Fig.19 )
2>.Thedividestructureelectricalremovement.
A.Howtoreplace themainPCB
Other Caple Wine Cooler manuals
Popular Wine Cooler manuals by other brands

Polar Electro
Polar Electro CE217 instruction manual

GE
GE Monogram ZDWI240 installation instructions

Festivo
Festivo 50 VL Instructions for installation and use

Wine Corner
Wine Corner Winemaster C50 IN Instructions for installation and use

Summit
Summit SCR321LWC2 instruction manual

Klarstein
Klarstein Bellevine deux 39 Flex manual