manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Caple
  6. •
  7. Wine Cooler
  8. •
  9. Caple Wi6114 Manual

Caple Wi6114 Manual

Other manuals for Wi6114

1

Other Caple Wine Cooler manuals

Caple Wi3113 User manual

Caple

Caple Wi3113 User manual

Caple WC6100 User manual

Caple

Caple WC6100 User manual

Caple WI6134 User manual

Caple

Caple WI6134 User manual

Caple JLWF604 Manual

Caple

Caple JLWF604 Manual

Caple WC6111 User manual

Caple

Caple WC6111 User manual

Caple WI3150 User manual

Caple

Caple WI3150 User manual

Caple WC6115 Manual

Caple

Caple WC6115 Manual

Caple WI6135 User manual

Caple

Caple WI6135 User manual

Caple WC6217 Manual

Caple

Caple WC6217 Manual

Caple WI6143 User manual

Caple

Caple WI6143 User manual

Caple WC1800 User manual

Caple

Caple WC1800 User manual

Caple WI6120 User manual

Caple

Caple WI6120 User manual

Caple WI6127 Manual

Caple

Caple WI6127 Manual

Caple WI6150 User manual

Caple

Caple WI6150 User manual

Caple WF1544 Manual

Caple

Caple WF1544 Manual

Caple WI3118 Manual

Caple

Caple WI3118 Manual

Caple WI3119 User manual

Caple

Caple WI3119 User manual

Caple WC1792 User manual

Caple

Caple WC1792 User manual

Caple WI3150 User manual

Caple

Caple WI3150 User manual

Caple WI3150 User manual

Caple

Caple WI3150 User manual

Caple WI6135 User manual

Caple

Caple WI6135 User manual

Caple WI6133 User manual

Caple

Caple WI6133 User manual

Caple WI6225 Manual

Caple

Caple WI6225 Manual

Caple Wi3112 User manual

Caple

Caple Wi3112 User manual

Popular Wine Cooler manuals by other brands

Sub-Zero WS-30 Specification sheet

Sub-Zero

Sub-Zero WS-30 Specification sheet

Rotel U903CH1 Instructions for use

Rotel

Rotel U903CH1 Instructions for use

Esatto EWC46 quick start guide

Esatto

Esatto EWC46 quick start guide

Sub-Zero Classic Series installation guide

Sub-Zero

Sub-Zero Classic Series installation guide

U-Line Echelon Wine Captain 2075WC Features & benefits

U-Line

U-Line Echelon Wine Captain 2075WC Features & benefits

Haier WS50GA user manual

Haier

Haier WS50GA user manual

Cavist 62 instruction manual

Cavist

Cavist 62 instruction manual

Kenmore 461.99130 owner's manual

Kenmore

Kenmore 461.99130 owner's manual

Danby DWC113BLSDB owner's manual

Danby

Danby DWC113BLSDB owner's manual

Avanti WC1001 instruction manual

Avanti

Avanti WC1001 instruction manual

Frigidaire FFWC38F6LS Factory parts catalog

Frigidaire

Frigidaire FFWC38F6LS Factory parts catalog

Titan TT-W2454SZ User guide & service manual

Titan

Titan TT-W2454SZ User guide & service manual

Klarstein Botella 166 Uno manual

Klarstein

Klarstein Botella 166 Uno manual

Costway FP10130WL manual

Costway

Costway FP10130WL manual

Lemair LWC59 instruction manual

Lemair

Lemair LWC59 instruction manual

Vinvautz VZ08BHK user manual

Vinvautz

Vinvautz VZ08BHK user manual

Haier JC-125GEA user manual

Haier

Haier JC-125GEA user manual

Climadiff CLI24 use instructions

Climadiff

Climadiff CLI24 use instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

WI6114
Caple 60cm Wine Cabinet
Technical information
Item Part Code Description Quantity
1DG13-1 Water tank 1
2DG2-14 Power cord 1
3DG7-3.2-BH Condenser fan 1
4DG19-3 Fan cover 1
5DG14-56 Bracket of fan (pair) 2
DG1-77 Compressor 1
B40-120/B 1
QP2-12/B 1
7DG13-272-1 PCB board cover 1
8DG6-15 Transformer 1
9DG3-99 PCB board 1
10 DG26-135 Cabinet 1
11 DG13-268 Decorative nail 3
12 DG13-7 Shelf support 2
13 DG20-1 Wire clamp 2
14 DG8-7-W Senser 1
15 DG14-190-SR Top hinge module(Right) 1
16 DG8-7-R Senser 1
17 DG12-1 Evaporator 1
18 DG18-93 foam 2
19 DG7-3.1-BH Evaporator fan 1
20 DG19-6 Fan cover 1
21 DG22-111 Air duct board 1
22 DG3-17-W LED light 1
23 DG22-379 Electrical box 1
24 DG20-257 Display panel 1
25 DG13-1.2 Humid box 1
26 DG15-157-1 Wooden shelf A6A NEW 1
27 DG23-171 Door 1
28 DG22-3064 handle 1
29 M160-050 Gasket 1
30 DG22-3057 Door axis 1
31 DG15-33 Wooden shelf G2 1
32 DG15-157 Wooden shelves A6 NEW 4
33 DG13-130-S Button 4
WI6114 - Caple 60cm Wine Cabinet
6
Item Part Code Description Quantity
WI6114 - Caple 60cm Wine Cabinet
34 DG14-189-SR Lower hinge module(Right) 1
35 DG22-88 Support bracket of front legs 1
36 DG14-189-SL Lower hinge module(Left)
37 DG12-91 Condenser 1
38 DG13-6.11 Cabinet leg 4
39 DG12-6.1 Air-circulating pipe 1
40 DG11-4 Drie
r
1
41 DG22-331 Compressor bracket 1
DG14-190-SL Top hinge module(Left)
DG22-3059 Decorative frame
WI6114
Ca
p
le
Sin
g
le
zone
wine
cabinet
Caple Single zone wine cabinet
Service Manual
1
SERVICEMANUAL
(One temperaturezone controlwinecoolar)
JGseriesincludesJG18 series,JG32B,JG45AJG50A,JG50A-1,JG50FA
Thecontentbelowshowsdifferentdefault mighthappenwhenthewinecoolerisworking,andalsoshowshowto
find thedefaultsandrepairthedefaults.Pleasefindthecorrespondingdefault statementandfindtherepair
informationinthecorresponding pages.
Statement:(Fig.4)shows thecorrelativediagramFig.4
( 6)shows thecorrelativepage6
WARNING:BeforeattemptinganycleaningormaintenancethisunitMustbedisconnectedformthe
electricalsupply, topreventelectricalshock.
▲Preparationbeforemaintenance
○Tools
1. Pliers
2. Phillipsheadscrewdrivers
3. Process pipe
4. ElectricalMultimeter
5.Ampmeter(5A)(calipercable type)
6. Electricalsolderingiron
7.Wirestrippers
8. Sealpliers
9/Scissors
○Equipment
1. Vacuumpump
2.Soldering ironforcopperpipes
3.Gas meter
▲Coolingsystemfault
○HowtoEvaluate thefault ... (Page 3)
○Howtorepairthefault (Page 3)
○Howtoremove theairductboard.. . (Page4)
○Diagramshowingthefrontside solderedjoints.. (Page 6)
○Diagramshowingthe rearside solderedjoints (page 7)
▲Noise problems
○Compressornoise. .. (Page 8)
○Fannoise.. .(Page 8)
○Refrigerantjetnoise... ... (Page 9)
○Capillaryvibrationnoise... ... . ... (Page 9)
○Oiljamnoise.. ... . (Page10)
▲Evaporatorfreezingproblems .(Page 10)
2
▲Unstableinternaltemperatureproblems .(Page 12)
▲Controlsystemproblems
○Faultfindingbythe self-checkmode ..(Page 12)
○Sensorfault ...(Page 12)
○LEDdisplayfault..(Page14)
○Howtoremove theelectricalbox. (Page 14)
○Thedismantlementmethod oftheelectricalboxspearpart. . (Page 14)
○Howtoreplace thelight .. (Page16)
○Howtoreplace theDecorativeframe .. (Page17)
3
△Coolingsystemfaults.
○Howtodiagnosefaults:
Itshouldtakeapproximate3hourstoreachthelowestsettingtemperatureof5℃foranemptyunit(assuming ambient
tempof32degreescentigradeandcontinuousoperation). Ifnot,checkthecompressor,coolingfans,controller, andsensors.
Ifall theseareworking normally,thereisprobablyacoolingsystem’sfault.
○Howtorepairthedefualt
1. Checkthe compressor
Turnonthe unitandcheckthere iselectricitycurrentflowingtothecompressorusinga calipertypeAmpmeter,the
currentshouldbewithin0.6to2Amps.Ifthereadingsarenotinthisrange, turnoffandcutoffthepipes (See Fig.8
showingG) andthesealpliers (See Fig.8showing E.) fromthecompressor,thenturntheunit onagain(inthiscase
onlyrun thecompressorforafewminuets,soastoavoidthecompressorabsorbmoistair)andrecheckthe
currentand ifthereispressureattheoutletpipe. Ifthecurrentreadingisstill outofrangespecifiedaboveandno
pressurefromthe compressoroutlet, replace the whole compressor.
2. Checkthecoolingsystempipe work:
Carefullycheckthecooling systemafterverifying thecompressorisworking normally.Thenfollowtheprocedure
below.
1>. Thencutoffprocess pipeandchecktherefrigerant.Ifthereisnotenoughrefrigerant,thedefualt oftherefrigerant
systemshouldbecausedbytheleaking.Ifthe refrigerantissufficient., itisprobablyjamedinthecapillary.
2>.Ifthedefault is concentratedon thecooling system,thechecking procedureis as below.
A.Cutoff theventpipeofthecompressor, andinfuse0.8-1MPnitrogenby process pipe, andpleaseputthehandclose
tothecutkerfoftheventpipe.Ifthereis alittlegas leakformtheterminal,it meansnormal, orit is jamed.
B. Makesurethecapilaryisworkingnormally,whenthedrainpipeisconnetcedagain,and infuse0.8-1MPnitrogen
thentesttheleakageifthecoolingsystemofthesoldering pointwiththesoapwater.Checkfromthethesoldering
pointarroundthecompressor(Fig.8&Fig.9、Fig.9.1),andifeverythingis ok,removetheair-ductboardand chech
thesoldering pointaround evaporator(Fig.6 &Fig.7).pleaseseetheremovemethodand theprocedureasbelow.
(Fig.1,Fig.2,Fig.3,Fig.4&Fig.5)
C.IfallthesolderingpointinB isnotleaking,therearetwopossibility, oneis leakageintheinnercondenser,another
isthedamageon theparts(suchas evaporator,condenserand soon)inthecoolingsystem.Ifitis theinnerdamage,
itcannotberepaired,andifthedamageontheparts, replace them.
3>.Makesurethatthereis notleakageinthecooling system, refilltherefrigerant.
3.Refillthe refrigerant:
1>. Using thevacuumpumpforma vacuuminthesystem,via the jointofthelow-pressureprocesspipeonthecompressor,
thehigh-pressurepipelineisontheprocess pipeofthefilter.Applythevacuumpumpforapproximately20 minutes.Until
thevacuumislowerthan100Pa.Thensolderthecompressorprocess pipeofthefilter.Keepthevacuumrunningwhile
solderingthisjoint
2>.FillCooling systemwithrefrigerantviatheprocesspipe. (TherefrigerantisR134a.Regardingrefrigerantquantity
Pleaserefertotheinstructionatbacklabelofwinecellar).Thensolderthecompressorprocess pipeafterthesystemis
chargedwithrefrigerant.
4.Running test:
Replaceall thecomponentsaftertheproceduresaboveandturntheuniton.Toverifytheeffectiveness oftherepair,
monitor