EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Carrier
  6. •
  7. Air Conditioner
  8. •
  9. Carrier CPFILTRK007A00 User manual

Carrier CPFILTRK007A00 User manual

This manual suits for next models

2

Other Carrier Air Conditioner manuals

Carrier P User manual

Carrier

Carrier P User manual

Carrier 73X Operating instructions

Carrier

Carrier 73X Operating instructions

Carrier Comfort 50VL-K User manual

Carrier

Carrier Comfort 50VL-K User manual

Carrier Performance 50VG Instruction Manual

Carrier

Carrier Performance 50VG Instruction Manual

Carrier 38AH044-084 Dimensions and installation guide

Carrier

Carrier 38AH044-084 Dimensions and installation guide

Carrier X-Power VRF series User manual

Carrier

Carrier X-Power VRF series User manual

Carrier 42VQV User manual

Carrier

Carrier 42VQV User manual

Carrier 38CKC User manual

Carrier

Carrier 38CKC User manual

Carrier 42QZA018DS-1 User manual

Carrier

Carrier 42QZA018DS-1 User manual

Carrier 48KH Dimensions and installation guide

Carrier

Carrier 48KH Dimensions and installation guide

Carrier 38AUM Series Instruction manual

Carrier

Carrier 38AUM Series Instruction manual

Carrier 42CJR024-723 User manual

Carrier

Carrier 42CJR024-723 User manual

Carrier 51QC/QG User manual

Carrier

Carrier 51QC/QG User manual

Carrier WALL MOUNTED AIR CONDITIONER User manual

Carrier

Carrier WALL MOUNTED AIR CONDITIONER User manual

Carrier 40MKCB**C/24AHA4 User manual

Carrier

Carrier 40MKCB**C/24AHA4 User manual

Carrier 42TSV0131BP User manual

Carrier

Carrier 42TSV0131BP User manual

Carrier N Style User manual

Carrier

Carrier N Style User manual

Carrier 48MA Manual

Carrier

Carrier 48MA Manual

Carrier OM38/40-6 User manual

Carrier

Carrier OM38/40-6 User manual

Carrier CRECOMZR101A00 User manual

Carrier

Carrier CRECOMZR101A00 User manual

Carrier 42TVAB010-O-I User manual

Carrier

Carrier 42TVAB010-O-I User manual

Carrier COMFORT 52C SERIES Service manual

Carrier

Carrier COMFORT 52C SERIES Service manual

Carrier ZONECC3Z Instructions and recipes

Carrier

Carrier ZONECC3Z Instructions and recipes

Carrier 42N S Series User manual

Carrier

Carrier 42N S Series User manual

Popular Air Conditioner manuals by other brands

Panasonic CS-E12HKEW operating instructions

Panasonic

Panasonic CS-E12HKEW operating instructions

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Installation Instructions
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could cause personal injury or death.
Electrical shock can cause injury or death.
Disconnect power supply and install lockout tag before attempting to
install accessory.
SAFETY CONSIDERATIONS
Installation and servicing of this equipment can be hazardous due
to mechanical and electrical components. Only trained and qualified
personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions such
as cleaning and replacing air filters. All other operations must be per-
formed by trained service personnel. When working on this equipment,
obsmwe precautions in the literature, on tags, and labels attached to or
shipped with the unit and other safety precautions that may apply.
Follow all safety codes. Installation must be in compliance with
local and national building codes. Wear safety glasses, protective cloth-
ing, and work gloves. Have fire extinguisher available.
Read these instructions thoroughly and follow all warnings or cau-
tions included in literature and attached to the unit.
Recognize safety information. This is the safety alert symbol 7_' .
When you see this symbol on the unit and in instructions or manua)/!\_e
alert to the potential for personal injur3z Understand these signal words:
DANGER, WARNING, and CAUTION. These words are used with
the safety alert symbol. DANGER identifies the most serious hazards
which will result in severe personal injury or death. WARNING signi-
fies hazards which could result in personal injury or death. CAUTION
is used to identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
CUT HAZARD
Failure to follow this caution may result in personal injury.
NOTE: On top filter rack for small cabinet, screw left side to coil
frame. On right side, bend tab on rack and screw to unit divider. Hold
height dimension shown in Fig. 2.
3. Install the bottom filter rack in the HVAC unit next to the indoor coil.
Filter rack will rest on the HVAC base and screw into the left and right
side of the coil frame. Be careful not to insert screws where coil dam-
age could occur. If using 2" (50.Smm) filters remove filter spacer. (See
Fig. 2A, 3Aand 4A.)
4. Install filters in rack. See Table 2 for sizes.
5. Replace filter access door on HVAC unit.
TABLE 1 - PACKAGE CONTENTS
Part No. Qty Description
1 Top Filter Rack
1 Bottom Filter Rack
CPFILTRK007A00 2 12 x 20 x 1in. (308.8 x 508 x 25.4mm) Filters
1 Hardware Bag
1 Instructions
1 Top Filter Rack
1 Bottom Filter Rack
1 14 x 24 x 1in. (355.6 x 609.6 x 25.4mm) Filter
CPFILTRK008A00 1 16 x 24 x 1in. (406.4 x 609.6 x 25.4mm) Filter
1 Hardware Bag
1 Instructions
1 Top Filter Rack
1 Bottom Filter Rack
1 16 x 24 x 1in. (406.4 x 609.6 x 25.4mm) Filter
CPFILTRK009A00 1 18 x 24 x 1in. (457.2 x 609.6 x 25.4mm) Filter
1 Hardware Bag
1 Instructions
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when handling parts.
General
These filter racks can be used in either a horizontal or vertical
discharge application, and are designed to accommodate either l" or 2"
(25.4mm or 50.Smm) wide filters. Use caution not to damage indoor
coil during installation.
Installation
1. Remove the filter access panel on the HVAC unit. (See Fig. 1.)
2. Install the top filter rack in the HVAC unit next to the indoor coil.
Lift rack to the very top of the return chamber and screw rack into coil
frame on both the left and right side. Be careful not to insert screws
where coil damage could occur. If using 2" (50.Smm) filters remove
filter spacer. (See Figs. 2A, 3A, and 4A.)
i
Filter Accessory Panel
for Accessory Filter Rack
Fig. 1 -Filter Access Panel for
Accessory Filter Rack
Filter
Clips
Filter spacer
remove for 2"
Evaporator
Cog
Fig. 2A
Fig. 2 -CPFILTRK007A00 Table 2 -Filter Sizes
PART NO.* l-IN. FILTERS SiZE 2-IN. FILTER SIZE**
CPFILTRK007A00 (2) 12 X 20 (304.8 X 508mm) (1) 10 x 20 (254 x 508mm)
(1) 12 x 20 (304.8 x 508mm)
CPFILTRK008A00 (1) 14 X 24 (355.6 X 609.6mm) (1) 14 x 24 (355.6 x 609.6mm)
(1) 16 X 24 (406.4 X 609.6mm) (1) 16 x 24 (406.4 x 609.6mm)
CPFILTRK009A001- (1) 16 X 24 (406.4 X 609.6mm) (2) 10 x 24 (254.0 x 609.6mm)
(1) 18 X 24 (457.2 X 609.6mm) (1) 14 x 24 (355.6 x 609.6mm)
*Unscrew- spacer brackets on the top filter rack to fit 2-in (50.8mm) filters
1-Place 14 x 24 x 2in. (254.0 x 609.6 x 50.8mm) filter at the right side of the coil and 10 x 24 x 2in
(254.0 x 609.6 x 50.8mm) filters at the left side in this order.
**2-in. filters not included.
Filter spacer
_" Top Filter
Fig. 3A
Filter
Rack
Filter
Rack
Screw
Fig. 4A
Filter spacer
remove for 2"
filters
Evaporating
Coil
Evaporating
Coil
Bottom Bottom Filter
Rack Rack d
Fig. 3 - CPFILTRK008A00 Fig. 4 -CPFILTRK009A00
Copyright 2010 CAC/BDP ® 7310 W. Morris St. ® Indianapolis, iN 46231 Printed in U.S.A. Edition Date: 09/10 Catalog No. iiK-CPFiLTRK-O2 Repiaces:llK-CPFILYRK-Ol
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations
Installation Instructions
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could cause personal injury or death.
Electrical shock can cause injury or death.
Disconnect power supply and install lockout tag before attempting to
install accessory.
SAFETY CONSIDERATIONS
Installation and servicing of this equipment can be hazardous due
to mechanical and electrical components. Only trained and qualified
personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions such
as cleaning and replacing air filters. All other operations must be per-
formed by trained service personnel. When working on this equipment,
obsmwe precautions in the literature, on tags, and labels attached to or
shipped with the unit and other safety precautions that may apply.
Follow all safety codes. Installation must be in compliance with
local and national building codes. Wear safety glasses, protective cloth-
ing, and work gloves. Have fire extinguisher available.
Read these instructions thoroughly and follow all warnings or cau-
tions included in literature and attached to the unit.
Recognize safety information. This is the safety alert symbol 7_' .
When you see this symbol on the unit and in instructions or manua)/!\_e
alert to the potential for personal injur3z Understand these signal words:
DANGER, WARNING, and CAUTION. These words are used with
the safety alert symbol. DANGER identifies the most serious hazards
which will result in severe personal injury or death. WARNING signi-
fies hazards which could result in personal injury or death. CAUTION
is used to identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
CUT HAZARD
Failure to follow this caution may result in personal injury.
NOTE: On top filter rack for small cabinet, screw left side to coil
frame. On right side, bend tab on rack and screw to unit divider. Hold
height dimension shown in Fig. 2.
3. Install the bottom filter rack in the HVAC unit next to the indoor coil.
Filter rack will rest on the HVAC base and screw into the left and right
side of the coil frame. Be careful not to insert screws where coil dam-
age could occur. If using 2" (50.Smm) filters remove filter spacer. (See
Fig. 2A, 3Aand 4A.)
4. Install filters in rack. See Table 2 for sizes.
5. Replace filter access door on HVAC unit.
TABLE 1 - PACKAGE CONTENTS
Part No. Qty Description
1 Top Filter Rack
1 Bottom Filter Rack
CPFILTRK007A00 2 12 x 20 x 1in. (308.8 x 508 x 25.4mm) Filters
1 Hardware Bag
1 Instructions
1 Top Filter Rack
1 Bottom Filter Rack
1 14 x 24 x 1in. (355.6 x 609.6 x 25.4mm) Filter
CPFILTRK008A00 1 16 x 24 x 1in. (406.4 x 609.6 x 25.4mm) Filter
1 Hardware Bag
1 Instructions
1 Top Filter Rack
1 Bottom Filter Rack
1 16 x 24 x 1in. (406.4 x 609.6 x 25.4mm) Filter
CPFILTRK009A00 1 18 x 24 x 1in. (457.2 x 609.6 x 25.4mm) Filter
1 Hardware Bag
1 Instructions
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when handling parts.
General
These filter racks can be used in either a horizontal or vertical
discharge application, and are designed to accommodate either l" or 2"
(25.4mm or 50.Smm) wide filters. Use caution not to damage indoor
coil during installation.
Installation
1. Remove the filter access panel on the HVAC unit. (See Fig. 1.)
2. Install the top filter rack in the HVAC unit next to the indoor coil.
Lift rack to the very top of the return chamber and screw rack into coil
frame on both the left and right side. Be careful not to insert screws
where coil damage could occur. If using 2" (50.Smm) filters remove
filter spacer. (See Figs. 2A, 3A, and 4A.)
i
Filter Accessory Panel
for Accessory Filter Rack
Fig. 1 -Filter Access Panel for
Accessory Filter Rack
Filter
Clips
Filter spacer
remove for 2"
Evaporator
Cog
Fig. 2A
Fig. 2 -CPFILTRK007A00 Table 2 -Filter Sizes
PART NO.* l-IN. FILTERS SiZE 2-IN. FILTER SIZE**
CPFILTRK007A00 (2) 12 X 20 (304.8 X 508mm) (1) 10 x 20 (254 x 508mm)
(1) 12 x 20 (304.8 x 508mm)
CPFILTRK008A00 (1) 14 X 24 (355.6 X 609.6mm) (1) 14 x 24 (355.6 x 609.6mm)
(1) 16 X 24 (406.4 X 609.6mm) (1) 16 x 24 (406.4 x 609.6mm)
CPFILTRK009A001- (1) 16 X 24 (406.4 X 609.6mm) (2) 10 x 24 (254.0 x 609.6mm)
(1) 18 X 24 (457.2 X 609.6mm) (1) 14 x 24 (355.6 x 609.6mm)
*Unscrew- spacer brackets on the top filter rack to fit 2-in (50.8mm) filters
1-Place 14 x 24 x 2in. (254.0 x 609.6 x 50.8mm) filter at the right side of the coil and 10 x 24 x 2in
(254.0 x 609.6 x 50.8mm) filters at the left side in this order.
**2-in. filters not included.
Filter spacer
_" Top Filter
Fig. 3A
Filter
Rack
Filter
Rack
Screw
Fig. 4A
Filter spacer
remove for 2"
filters
Evaporating
Coil
Evaporating
Coil
Bottom Bottom Filter
Rack Rack d
Fig. 3 - CPFILTRK008A00 Fig. 4 -CPFILTRK009A00
Copyright 2010 CAC/BDP ® 7310 W. Morris St. ® Indianapolis, iN 46231 Printed in U.S.A. Edition Date: 09/10 Catalog No. iiK-CPFiLTRK-O2 Repiaces:llK-CPFILYRK-Ol
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations