WARNING: All controls that are to be used to operate the gate system, MUST be installed where the user cannot touch the gate while
operating the controls. Also, always install the controls where the user has full view of gate operation.
All inputs are normally open and momentary, except the stop (NC), and emergency close & emergency open (constant pressure). The following instructions are
based upon UL 325, dated March of 1999 and include recommendations for significant increase in safety. We strongly recommend that you follow the UL
guidelines presented throughout the manual. Installation device instructions - always follow the instructions provided by the manufacturer when installing and
adjusting any control device. If these instructions are contrary to the advise given here, call for assistance.
Numbers shown inside a box are on the J1 terminal strip on the circuit board.
Connections shown here are field connections. The radio receiver may be ordered factory installed.
9
RECEIVER
CONTROL PANEL
TERMINAL STRIP
External Entrapment open
Will reverse (close) the gate if active. If struck
again during a reversal the gate will stop.
RADIO
1 2 3
ON SIDE OF
R1
R3
R2
OPEN
5
GATE LOCK
MASTER/SLAVE
POWER
SUPERVISED OPEN BUTTON
Caution - Only wired devices in sight of the gate
may be used with this input.
For wireless device see fig 2.
57
(WIRELESS) OPEN BUTTON
UNSUPERVISED
Any device can be used here and the radio (R2)
is wired here internally by the factory. Note, on
a second obstruction, this input will not function
(disabled). See page 8 for details.
56
Secondary safety
It is recommended that secondary
safeties always be used for both
the open and close directions.
Use photo eyes, safety edges or both. In any case, the
device must sense people. Loops cannot be used.
External Entrapment close
Will reverse (open) the gate if active.If struck
again during a reversal the gate will stop.
May defeat the timer to close.
CLOSE
510
Close/single button
This input allows for either a close operation, or
single button. In the single button mode, the
feature opens the operator except when on the
open limit where it will act as a close.
4
5
These are constant pressure inputs that
bypasses the processor and may be used in an
emergency even if the processor fails.
Interrupt loop
This input is for vehicles only and does not
provide UL secondary safety for persons. This
functions as an wireless open unless on the
close limit where it is defeated - thus preventing
vehicles from entering.
58
STOP BUTTON
- REQUIRED -
This is a normally closed input and the operator
will not run unless this is installed!
2
335
E- OPEN
E- CLOSE
1
11
11 12
12
Use shielded twisted pair.
do not run with power wiring.
USE POWER TO MATCH GATE LOCK
REQUIREMENTS, NOT TO EXCEED 115V 10A.
FOR WARNING DEVICES, CALL THE FACTORY
13 14
24 VAC