Maintenance and Upgrade
•Power Button Shut Down, on page 1
•Enable RPC, on page 2
•Reset the Chassis Remotely, on page 3
•Install/Uninstall the Locking Faceplate, on page 3
•Remove and Replace a Drive, on page 4
•Remove and Replace a Power Supply, on page 7
Power Button Shut Down
The chassis runs in two modes:
• Main power mode—Power is supplied to all components and all operating systems can run.
• Standby power mode—Power is supplied only to the service processor and certain components. You can
safely remove power cords from the chassis in this mode.
After you shut down the chassis to standby power, electric current is still present in the chassis. To completely
remove power as directed in some maintenance procedures, you must disconnect all power cords from all
power supplies in the chassis.
Caution
You can shut down the chassis using the front panel Power button or software management.
Step 1 Check the Power LED:
• Amber—The chassis is already in standby mode and you can safely remove power.
• Green—The chassis is in main power mode and you must shut it down before you can safely remove power.
Step 2 Perform a graceful shutdown or a hard shutdown:
To avoid data loss or damage to your operating system, perform a graceful shutdown of the operating system.
Caution
• Graceful shutdown—Press and release the Power button. The operating system performs a graceful shutdown and
the chassis goes into standby mode. The power LED is amber.
Maintenance and Upgrade
1
•Emergency shutdown—Press and hold the Power button for four seconds to force the main power off and immediately
enter standby mode.
Step 3 If a maintenance procedure instructs you to completely remove power from the chassis, disconnect all power cords from
the power supplies.
Enable RPC
You must enable and configure RPC before you can remotely reset chassis power.
Before you begin
• Cable the RPC port directly to a secure network.
• Open necessary ports through the firewall to make sure the chassis is accessible remotely.
• RPC requires a unique IPv4 address for the RPC port. You must use the following procedure to configure
the RPC port. You cannot configure it using the ipconfig command.
•To cycle chassis power you must have a third-party tool that supports the Intelligent Platform Management
Interface (IPMI) version 2.0.
Step 1 Use SSH or the serial console port to access the CLI.
Step 2 Log in using an account with Administrator access.
Step 3 Enter the following commands:
remotepower
setup
Step 4 Follow the prompts to specify the following:
• The dedicated IP address for the RPC port, netmask, and gateway.
• The username and password required to execute the power-cycle command.
These credentials are independent of other credentials used to access your appliance. Store this information for
administrators who may need to set up RPC in the future.
Step 5 Enter commit to save your changes.
Step 6 Test your configuration to verify that you can remotely manage chassis power.
What to do next
Reset the Chassis Remotely, on page 3
Maintenance and Upgrade
2
Maintenance and Upgrade
Enable RPC
Reset the Chassis Remotely
If the chassis requires a hard reset, you can reboot the chassis remotely using a third-party IPMI tool.
Before you begin
• You must enable RPC in advance. See Enable RPC, on page 2 for the procedure.
• Only the following IPMI commands are supported. Refer to your IPMI tool documentation on how to
use them.
status, on, off, cycle, reset, diag, soft
• Set up a utility that can manage devices using IPMI version 2.0.
Step 1 Use IPMI to issue a supported power-cycling command to the IP address assign to the RPC port.
The RPC port must be configured with the required credentials. See Enable RPC, on page 2 for more
information.
Note
For example, issue the following command from a UNIX computer with IPMI support:
ipmitool -I lan -H ip-address -U remoteresetuser -P password chassis power reset
Step 2 Wait at least 11 minutes for the chassis to reboot.
Install/Uninstall the Locking Faceplate
The locking faceplate (Cisco part number 74-115098-01 for a 1 RU chassis and Cisco part number 74-115099-01
for a 2 RU chassis) ships with the key you need to lock the faceplate to the front panel of the chassis. The
locking faceplate clicks in between the two side handles on the front panel.
Step 1 Insert the right side of the locking faceplate by aligning the two plastic tabs with the two cutouts on the right side handle
on the front of the chassis.
Maintenance and Upgrade
3
Maintenance and Upgrade
Reset the Chassis Remotely
Figure 1: Locking Faceplate
Key hole2Latch1
Spring-mounted tab4Spring-mounted tab3
Step 2 Press in the left side of the faceplate into the left side handle on the front panel. The tabs are spring-mounted to the latch,
so they push in as the faceplate is installed.
Step 3 Lock the faceplate using the key that shipped with the faceplate.
Step 4 To uninstall the faceplate, unlock the faceplate, push the latch to the right, and pull the faceplate out.
Remove and Replace a Drive
The drives are hot-swappable. You do not have to shut down the chassis to remove or replace drives.
Note
Maintenance and Upgrade
4
Maintenance and Upgrade
Remove and Replace a Drive
You cannot add more drives to the chassis. You can only replace the drives in the slots that are supported for
your model.
Note
Before you begin
Statement 1018—Supply Circuit
To reduce risk of electric shock and fire, take care when connecting units to the supply circuit so that wiring
is not overloaded.
Warning
Statement 1019—Main Disconnecting Device
The plug-socket combination must be accessible at all times, because it serves as the main disconnecting
device.
Warning
Statement 1024—Ground Conductor
This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or
operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical
inspection authority or an electrician if you are uncertain that suitable grounding is available.
Warning
Statement 1030—Equipment Installation
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1073—No User-Serviceable Parts
No serviceable parts inside. To avoid risk of electric shock, do not open.
Warning
Statement 1074—Comply with Local and National Electrical Codes
To reduce risk of electric shock or fire, installation of the equipment must comply with local and national
electrical codes.
Warning
Step 1 Remove the drive that you are replacing:
a) Press the release button on the face of the drive tray.
b) Grasp and open the ejector lever and then pull the drive tray out of the slot.
Maintenance and Upgrade
5
Maintenance and Upgrade
Remove and Replace a Drive
Figure 2: Remove the Drive
Release button2Ejector handle1
Step 2 Remove the four drive-tray screws that secure the drive to the tray and then lift the drive out of the tray.
Figure 3: Remove the Drive Tray
Maintenance and Upgrade
6
Maintenance and Upgrade
Remove and Replace a Drive
Drive removed from drive tray2Drive tray screws ( two on each side)1
Step 3 Install a new drive:
a) Place a new drive in the empty drive tray and install the four drive-tray screws.
b) With the ejector lever on the drive tray open, insert the drive tray into the empty drive bay.
c) Push the tray into the slot until it touches the backplane, and then close the ejector lever to lock the drive in place.
Remove and Replace a Power Supply
Two power supplies ship with the chassis; they are redundant and hot-swappable. One is the active power
supply and the other is the standby power supply (1+1).
The C195 ships with one power supply, but you can add another one for redundancy.
Note
The chassis also supports cold redundancy. Depending on the power being drawn by the chassis, one power
supply might actively provide all power to the system while the remaining power supply is put into a standby
state. For example, if the power consumption can be satisfied by power supply 1, then power supply 2 is put
into a standby state.
When you replace power supplies, do not mix power supply types in the chassis. Both power supplies must
be the same wattage and Cisco PID.
Caution
Power supply health monitoring notifies you if the power supply loses power or malfunctions so that redundancy
is lost. Check the power supply cables to make sure they are functioning. If they are and errors are still
occurring, replace the power supply.
Trouble
Before you begin
Take note of the following warnings:
Statement 1018—Supply Circuit
To reduce risk of electric shock and fire, take care when connecting units to the supply circuit so that wiring
is not overloaded.
Warning
Maintenance and Upgrade
7
Maintenance and Upgrade
Remove and Replace a Power Supply
Statement 1019—Main Disconnecting Device
The plug-socket combination must be accessible at all times, because it serves as the main disconnecting
device.
Warning
Statement 1024—Ground Conductor
This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or
operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical
inspection authority or an electrician if you are uncertain that suitable grounding is available.
Warning
Statement 1030—Equipment Installation
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1073—No User-Serviceable Parts
No serviceable parts inside. To avoid risk of electric shock, do not open.
Warning
Statement 1074—Comply with Local and National Electrical Codes
To reduce risk of electric shock or fire, installation of the equipment must comply with local and national
electrical codes.
Warning
Step 1 Remove the power supply that you are replacing or the blank panel from an empty bay:
a) Do one of the following actions:
• If the chassis has one power supply, shut down and remove power from the chassis. See Power Button Shut
Down, on page 1 for the procedure.
• If the chassis has two power supplies, you do not have to shut down the chassis.
b) Remove the power cord from the power supply that you are replacing.
c) Grasp the power supply handle while pinching the release lever toward the handle.
d) Pull the power supply out of the bay.
Maintenance and Upgrade
8
Maintenance and Upgrade
Remove and Replace a Power Supply
Figure 4: Remove and Replace the AC Power Supply
Handle2Release lever1
Step 2 Install a new power supply:
a) Grasp the power supply handle and insert the new power supply into the empty bay.
b) Push the power supply into the bay until the release lever locks.
c) Connect the power cord to the new power supply.
d) If you shut down the chassis, press the Power button to return it to main power mode.
Maintenance and Upgrade
9
Maintenance and Upgrade
Remove and Replace a Power Supply
Maintenance and Upgrade
10
Maintenance and Upgrade
Remove and Replace a Power Supply

This manual suits for next models

3

Other Cisco Security System manuals

Cisco MEDVIEW-C-30XS-A01 User manual

Cisco

Cisco MEDVIEW-C-30XS-A01 User manual

Cisco MARS Instructions for use

Cisco

Cisco MARS Instructions for use

Cisco ISA550 User manual

Cisco

Cisco ISA550 User manual

Cisco M5 User manual

Cisco

Cisco M5 User manual

Cisco Firepower 1100 Series User manual

Cisco

Cisco Firepower 1100 Series User manual

Cisco WVC200 - Wireless-G PTZ Internet Camera Instruction Manual

Cisco

Cisco WVC200 - Wireless-G PTZ Internet Camera Instruction Manual

Cisco IronPort S670 User manual

Cisco

Cisco IronPort S670 User manual

Cisco 6400E User manual

Cisco

Cisco 6400E User manual

Cisco 500 Series User manual

Cisco

Cisco 500 Series User manual

Cisco ASA 55 Series Quick start guide

Cisco

Cisco ASA 55 Series Quick start guide

Cisco Meraki MX67 User manual

Cisco

Cisco Meraki MX67 User manual

Cisco Small Business Pro SA 500 Series User manual

Cisco

Cisco Small Business Pro SA 500 Series User manual

Cisco Telepresence MX200 Instruction Manual

Cisco

Cisco Telepresence MX200 Instruction Manual

Cisco PIX 525 User manual

Cisco

Cisco PIX 525 User manual

Cisco PIX-515-RPS - PIX 515-R - Firewall User manual

Cisco

Cisco PIX-515-RPS - PIX 515-R - Firewall User manual

Cisco ASA 5506W-X Manual

Cisco

Cisco ASA 5506W-X Manual

Cisco 4116 - EtherFast Switch Guide

Cisco

Cisco 4116 - EtherFast Switch Guide

Cisco C395 Manual

Cisco

Cisco C395 Manual

Cisco NCS 4000 Series User manual

Cisco

Cisco NCS 4000 Series User manual

Cisco PIX 501 - Security Appliance User manual

Cisco

Cisco PIX 501 - Security Appliance User manual

Cisco ISA550 Instruction Manual

Cisco

Cisco ISA550 Instruction Manual

Cisco Codec C Series User manual

Cisco

Cisco Codec C Series User manual

Cisco MS410-16 User manual

Cisco

Cisco MS410-16 User manual

Cisco Firepower 2100 Series Manual

Cisco

Cisco Firepower 2100 Series Manual

Popular Security System manuals by other brands

Pudu GW1 user manual

Pudu

Pudu GW1 user manual

Perel CCTVSETW1 Installation and quick start

Perel

Perel CCTVSETW1 Installation and quick start

GE Euro Simon installation instructions

GE

GE Euro Simon installation instructions

Nortel CallPilot 100 Administration guide

Nortel

Nortel CallPilot 100 Administration guide

PeopleKey V30 Plus quick start guide

PeopleKey

PeopleKey V30 Plus quick start guide

Clever CL-IV Setup and operation

Clever

Clever CL-IV Setup and operation

Honeywell 702 Installation instructions manual

Honeywell

Honeywell 702 Installation instructions manual

eTIGER S4 Combo Secual manual

eTIGER

eTIGER S4 Combo Secual manual

Chamberlain RWA310R user manual

Chamberlain

Chamberlain RWA310R user manual

API 1000 G quick start guide

API

API 1000 G quick start guide

Mammut BARRYVOX user manual

Mammut

Mammut BARRYVOX user manual

Jesmay Electronics 4642R owner's manual

Jesmay Electronics

Jesmay Electronics 4642R owner's manual

M-system KS2TR2 instruction manual

M-system

M-system KS2TR2 instruction manual

AFRISO WGA 01 manual

AFRISO

AFRISO WGA 01 manual

R.W. BECKETT GENISYS 52040 installation instructions

R.W. BECKETT

R.W. BECKETT GENISYS 52040 installation instructions

ADEMCO 4150 user manual

ADEMCO

ADEMCO 4150 user manual

USP Wanderer Alert WA-900 user manual

USP

USP Wanderer Alert WA-900 user manual

Rasilient ApplianceStor 85 user manual

Rasilient

Rasilient ApplianceStor 85 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.