Claudgen RAC4500 Manual

41000942 iss 04
Consort Equipment Products Ltd
Registered Office: Thornton Industrial Estate
Milford Haven, embrokeshire, SA73 2RT
Tel: 01646 692172 Fax: 01646 695195
BS EN ISO 9001 Registered Company No FM12671
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR
Recessed W rm Air Curt in He ters
C t logue Numbers RAC3000 (3 kW) nd RAC4500 (4.5 kW)
PLEASE RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE
MODELS
These units are 600mm 3kW & 4.5kW modular recessed
heaters designed for mounting above doorways and similar
entrances to fit directly into a 600 mm grid in a suspended
ceiling, and may be used as space heaters. (Minimum ceiling
height of 2.2m: maximum height 2.8m).
Weight 9.5kg
MOUNTING
When fitting ensure that the air discharge is situated as close
to the door as possible. The recessed air curtains are
designed to fit directly into any suspended ceiling, especially
ceiling tile grid formation. If the grid does not align with the
door then it will need modifying.
The unit should be mounted so that the airflow is not
obstructed by any part of the doorframe.
41000942 iss 04
41000942 iss 04
ELECTRICAL CONNECTIONS
These units are suitable for connection to a 230/240 Volt 50 Hz
single-phase AC supply. The heaters consume 3kW, 4.5kW
respectively at 240 volts when switched to the full heat position.
RAC3000 3 kW 12.5A
RAC4500 4.5 kW 18.75A
Units should only by wired by a competent electrician in
accordance with the latest edition of the IEE wiring regulations.
Ensure that the supply cables and circuit breakers are sufficient
for the air curtain being installed.
The appliance should be connected to the supply via a circuit in
which there is an all-pole switch.
To gain access to electrical connection the recessed grille must
be removed. The grille is secured to the enclosure of the air
curtain via 4 cross head screws – see Figure 3. Cable entry may
be moved to alternative position if desired.
For safety reasons a sound earth connection must always be
made to the unit before it is put to use. The unit should be
wired in accordance with IEE Regulations for the Electrical
Equipment of Buildings.
NOTE: The unit MUST be reliably earthed.
OPERATION
All units are supplied with a remote switch that gives the
following functions; On/off & two heat settings.
For thermostatic control a room thermostat maybe connected.
CONTROLS
To switch on the appliance and operate the blower, depress the
left-hand switch (marked “FAN”).
When the centre switch only (marked with a single bar) is
depressed the heat output is ⅓ of full heat. When the right
hand switch only (marked with a double bar) is depressed the
heat output is ⅔ of full heat. When both the centre switch and
the right-hand switch are depressed the full heat output is
available.
MAINTENANCE
Always ensure that the main external electricity supply is
switched off before attending to the servicing of your Claudgen
Screen-Zone heater.
To obtain best results from your heater it is necessary to avoid
the build up of dust and dirt within the unit and on the air inlet
and discharge grills. For this reason regular cleaning is
necessary, paying particular attention to the removal of dirt
build up on the rotor blades. A single drop of light oil should be
applied to the motor bearing from time to time.
PROTECTION (Therm l Cut-out)
The units are protected from overheating in the event of fan
failure or an obstruction of the free airflow, by an auto reset
thermal cut outs. If this happens the thermal cut outs
effectively switches off the appliance. The appliance will not
operate until it has cooled down. If this fault re-occurs again,
refer to ‘fault conditions’.
FAULT CONDITIONS
If the heater will not operate, disconnect it from the mains and
arrange for a certified electrician to attend to investigate the
reason.
TO REPLACE THE FAN HEATER ASSEMBLY
a) Remove the grille.
b) Disconnect the internal wiring from the main terminal
block.
c) Remove the four nuts and washers fixing the fan heater
assembly to the back of the case.
d) The fan heater assembly can now be eased forward and
removed from the heater case.
e) Fit replacement fan heater and reassemble in reverse order.
SPARES
It is essential when ordering spares or replacement parts to
state the model number and the serial number on the rating
place fixed to the top of the unit.
In the interest of progress the Company reserve the right to vary
specifications from time to time without notice. The material
listed is offered subject to the Company’s General Conditions of
Sale, a copy of which can be obtained on request.
NOTE: DO NOT COVER ny of the ir inlet or outlet grills, t
ny time.

This manual suits for next models

1

Other Claudgen Heater manuals

Claudgen HE7230SL User manual

Claudgen

Claudgen HE7230SL User manual

Claudgen SCREENZONE RAC1306 User manual

Claudgen

Claudgen SCREENZONE RAC1306 User manual

Claudgen ScreenZone CA2015S User manual

Claudgen

Claudgen ScreenZone CA2015S User manual

Claudgen CH06CSi User manual

Claudgen

Claudgen CH06CSi User manual

Claudgen HE6502 Manual

Claudgen

Claudgen HE6502 Manual

Claudgen HE6137SL Use and maintenance manual

Claudgen

Claudgen HE6137SL Use and maintenance manual

Claudgen SCREENZONE RAC1306 User manual

Claudgen

Claudgen SCREENZONE RAC1306 User manual

Claudgen ScreenZone CA1309S10 User manual

Claudgen

Claudgen ScreenZone CA1309S10 User manual

Claudgen HE7402-31 Manual

Claudgen

Claudgen HE7402-31 Manual

Claudgen HE7402RF Manual

Claudgen

Claudgen HE7402RF Manual

Claudgen HE8320RX Original operating instructions

Claudgen

Claudgen HE8320RX Original operating instructions

Claudgen HE7237 User manual

Claudgen

Claudgen HE7237 User manual

Claudgen HE8326-33 Manual

Claudgen

Claudgen HE8326-33 Manual

Claudgen HE8320 Manual

Claudgen

Claudgen HE8320 Manual

Claudgen CH06CSiRX User manual

Claudgen

Claudgen CH06CSiRX User manual

Claudgen Heat-Zone Manual

Claudgen

Claudgen Heat-Zone Manual

Claudgen HE7230W Installation and operating instructions

Claudgen

Claudgen HE7230W Installation and operating instructions

Claudgen CA1309S Manual

Claudgen

Claudgen CA1309S Manual

Claudgen RAC1509 User manual

Claudgen

Claudgen RAC1509 User manual

Claudgen HE8320-30 Manual

Claudgen

Claudgen HE8320-30 Manual

Claudgen HE6351 Manual

Claudgen

Claudgen HE6351 Manual

Claudgen HE7010W-30 Manual

Claudgen

Claudgen HE7010W-30 Manual

Claudgen HE7237 Manual

Claudgen

Claudgen HE7237 Manual

Claudgen HE7230 User manual

Claudgen

Claudgen HE7230 User manual

Popular Heater manuals by other brands

SAMITECH Heat Wrap user manual

SAMITECH

SAMITECH Heat Wrap user manual

REMKO HTL 250-EC operating manual

REMKO

REMKO HTL 250-EC operating manual

Hornbach 10530792 operating manual

Hornbach

Hornbach 10530792 operating manual

Rowenta SO2330 user guide

Rowenta

Rowenta SO2330 user guide

ThermoUp FLOOR manual

ThermoUp

ThermoUp FLOOR manual

Tecnogas Tecnobreeze 14261 manual

Tecnogas

Tecnogas Tecnobreeze 14261 manual

Aerotech BT 400-46 Installation and operation maintenance

Aerotech

Aerotech BT 400-46 Installation and operation maintenance

Frost Fighter IDH200QR OIL Installation, operation & maintenance instructions

Frost Fighter

Frost Fighter IDH200QR OIL Installation, operation & maintenance instructions

SUNTEC Klimatronic Heat Safe humid 1000 instruction manual

SUNTEC

SUNTEC Klimatronic Heat Safe humid 1000 instruction manual

Waves HO-101413 manual

Waves

Waves HO-101413 manual

ARDES AR4W08P Instructions for use

ARDES

ARDES AR4W08P Instructions for use

Buderus 21 Applications manual

Buderus

Buderus 21 Applications manual

Fakir QS 1200 Instructions for use

Fakir

Fakir QS 1200 Instructions for use

Hitachi YUTAMPO Series Service manual

Hitachi

Hitachi YUTAMPO Series Service manual

EOS EURO Assembly and operating instruction

EOS

EOS EURO Assembly and operating instruction

TwinStar SH-DH-15-TS operating manual

TwinStar

TwinStar SH-DH-15-TS operating manual

Rowenta SO6511F2 Safety instruction

Rowenta

Rowenta SO6511F2 Safety instruction

Teddington ROBUVENT operating manual

Teddington

Teddington ROBUVENT operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.